• Title/Summary/Keyword: EMTP simulation

Search Result 295, Processing Time 0.026 seconds

A Dynamic Simulation of Voltage Instability Using EMTP (EMTP를 이용한 전압 불안정 현상의 동적 시뮬레이션)

  • 허정용;김철환
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.6
    • /
    • pp.295-300
    • /
    • 2003
  • Voltage instability has been studied for some decade now. But, There is not generally accepted definition of voltage instability because of the complex phenomenon and the variety of ways in which it can manifest itself. Both IEEE and CIGRE have the respective definitions. The areas of voltage instability research are the analysis, simulation and countermeasure of voltage instability. It needs to model the components of the power system to simulate the voltage instability and voltage collapse. At the beginning, the static simulation was used. This method provides the voltage stability indices and it requires less CPU resource and gives much insight into the voltage and power problem. However, it is less accurate than the dynamic simulation peformed in the time domain simulation. So, when it appears difficult to secure the voltage stability margin in a static stability, it is necessary to perform the dynamic simulation. To perform time-domain simulation, we have to model the dynamic component of the power system like a generator and a load. The dynamic simulation provides the accurate result of the voltage instability. But, it is not able to provide the sensitivity information or the degree of stability and it is time consuming and it needs much CPU resource. In this Paper, we perform a dynamic simulation of voltage instability and voltage collapse using EMTP MODELS. The exponential load model is designed with MODEIS and this load model is connected with test power system. The result shows the process of voltage change in time domain when the voltage instability or voltage collapse occurs.

A Study on the Dynamic Responses of a PWM Based UPFC for the Application to Power System Through EMTP Simulation (EMTP 모의를 통한 PWM 방식 UPFC의 동적 특성 분석 및 전력 시스템 적용에 관한 연구)

  • Won, Dong-Jun;Han, Hak-Geun;Lee, Song-Geun;Mun, Seung-Il
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.12
    • /
    • pp.581-588
    • /
    • 2000
  • This paper presents the power system application of a PWM base UPFC through EMTP simulation. A PWM base UPFC model is constructed and detailed switching-level simulation is performed using EMTP. The dynamic responses of UPFC are analyzed. Based on the simulation results, the appropriate equivalent impedances of UPFC voltage-source model which represent similar dynamics with PWM based UPFC are determined by optimization routine. This paper also analyzes the influence of the power system strength on the dynamic responses of UPFC. Finally this paper shows that the performance of UPFC is improved by control parameter tuning when UPFC is installed to weak power system.

  • PDF

Analysis of the Overvoltages during Energizing Transmission Lines using EMTP (EMTP를 이용한 시송전 계통의 송전선로 초기 가압시 과전압 분석에 관한 연구)

  • Yeo, Sang-Min;Kim, Chul-Hwan;Lyu, Young-Sik;Joo, Haeng-Ro;Cho, Burm-Sup
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.873-878
    • /
    • 2009
  • When the transmission lines are initially energized for power system restoration, the power system suffers the various overvoltages that can be classified as steady-state, transient, and dynamic overvoltages. For the accurate analyses of these overvoltages, many researchers utilize different simulation tools such as Power System Simulator for Engineering(PSS/E). Although PSS/E provides good solutions in steady-state and dynamic overvoltages, it is not suitable for transient overvoltages. Therefore, transient overvoltages are simulated by using Electro-Magnetic Transients Program(EMTP) developed for the analysis of transients in the power system. Recently, EMTP can be also used to simulate dynamic behavior of the system. In order to analyze the transient overvoltages with steady-state and dynamic overvoltages, the authors adopt EMTP as the simulation tool for the analysis of overvoltages. This paper presents the simulation results for the analyses of various overvoltages, and the possibility of EMTP to be used for these types of analyses.

Simulation Method of Photovoltaic Generation Systems using EMTP Type Simulators (EMTP형 시뮬레이터를 이용한 태양광발전시스템 모의 방법)

  • Park Minwon;Yu In-Keun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.6
    • /
    • pp.303-308
    • /
    • 2005
  • As the cost of photovoltaic(PV) generation systems continues to decrease, utility interactive systems are becoming more economically viable. Furthermore, increases in consumer awareness correspond to a willingness to pay a premium price for clean electrical energy generated using renewable energy resources. Especially, PV generation systems, in particular, is undergoing a rapid expansion-showing an industrial growth of approximately 40$\%$ per year in the worldwide, as PV cell and systems technology improve new markets become increasingly accessible. This has resulted in an increased demand for the simulation scheme and operational technologies of utility interactive PV devices and systems. The simulation schemes that can be applied to the utility interactive PV generation systems readily and cheaply under various conditions considering the sort of solar cell, the capacity of systems and the converter system as well are strongly expected and emphasized among researchers. So far, authors have been introducing the simulation method of PV generation systems with several papers. In this paper, authors introduce the simulation way of PV generation systems using EMTP type simulators; EMTP/ATP, EMTDC/PSCAD, RTDS, with each examples. And, by connecting the voltage amplifier to the RTDS a novel simulation method which is extremely close to the real condition of PV generation system is also introduced.

EMTP Simulation of Bipolar HVDC System (바이폴 HVDC 시스템의 EMTP 시뮬레이션)

  • Kwak, Joo-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1053-1055
    • /
    • 1998
  • Using EMTP model which describes bipolar HVDC system, switching level simulation results are presented in this paper. Voltage synchronization at point of common coupling, gate pulse generation and current control loops are represented in TACS module. The system consists of 100 km submarine cable rated 300 MW and 12 pulse rectifier and inverter stations which are connected to equivalent three-phase sources and loads through the 154 kV AC lines, respectively. In convertor stations, harmonic filters and capacitor banks are equipped to cancel out the harmonics generated by converters and to supply the required reactive power.

  • PDF

A Dynamic Simulation of Distance Relay Using EMTP MODELS (EMTP MODELS를 이용한 거리 계전기 응동 시뮬레이션)

  • 허정용;김철환;여상민
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.1
    • /
    • pp.17-28
    • /
    • 2003
  • Digital technology has advanced very significantly over the years both in terms of software tools and hardware available. It is now applied extensively in many area of electrical engineering including protective relaying in power systems. Digital relays based on digital technology have many advantages over the traditional analog relays. The digital relay is able to do what is difficult or impossible in the analog relays. However, the complex algorithms associated with the digital relays are difficult to test and verify in real time on real power systems. Although non real-time simulators like PSCAD/EMTDC are employed to test the algorithms, such simulations have the disadvantage that they cannot test the relay dynamically. Hence, real-time simulators like RTDS are used, but the latter needs large space and it is very expensive. This paper uses EMTP MODELS to simulate the power system and the distance relay. The distance relay algorithm is constructed and the distance relay is interfaced with a test power system. The distance relays performance is then assessed interactively under various fault types, fault distances and fault inception angles. The test results show that we can simulate the distance relay effectively and we can examine the operation of the distance relay very closely including debugging by using EMTP MODELS.

Digital Time-Domain Simulation of Ferroresonance of Potential Transformer in the 154 kV GAS Insulated Substation

  • Shim, Eung-Bo;Woo, Jung-Wook;Han, Sang-Ok
    • KIEE International Transactions on Power Engineering
    • /
    • v.11A no.4
    • /
    • pp.9-14
    • /
    • 2001
  • This paper reports a set of digital time-domain simulation studies conducted on 154 kV wound Potential Transformer(PT) int he 154 kV Gas Insulated Substation(GIS). The Electro-Magnetic Transient Program(EMTP) is used to develop the PT model and conduct the transient studies. The accuracy of the PT model is verified through comparison of the EMTP simulation results with those obtained from the field test results. The investigations shows that the developed model can accurately predict PT transient resonance, especially, the phenomenon of ferroresonance. The model is developed not only to determine impact of transients on PT response but also to design ferroresonance suppressor devices of PT. And it can also be used to predict PT transient response on power system monitoring and protection scheme.

  • PDF

Development and Application of EMTP based Simulator for Analysis of Underground Power Cable Systems (EMTP 기반 지중송전계통 해석용 시뮬레이터 개발 및 응용)

  • Jung, Chae-Kyun;Lee, Jong-Beom;Lee, Won-Kyo;Lee, Dong-Il;Hwang, Kap-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.320-321
    • /
    • 2008
  • In this paper, new simulator based on EMTP was introduced for simulation of underground power cable system. The newly developed simulator was named as Power Cable Simulator(PCS), and it can simulate the various normal conditions including sheath circulating current. It is also easier to use than conventional software, such as EMTP and CabSim, because all the data for calculating the cable parameters are stored in a database(DB) within a PCS. In addition, the accuracy of PCS is also proved through the comparison between the calculation and simulation of sheath current.

  • PDF

A Study on control realization of FACTS equipment in Electric Railway Systems using EMTP MODELS (EMTP MODELS를 이용한 전기철도 FACTS 설비의 제어 구현 연구)

  • Oh, Min-Hyuk;Lee, Byung-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.329-330
    • /
    • 2006
  • The purpose of this paper is to compensate the voltage drop of the power system in the AC Electric Railway Systems. Reactive power compensation is often the most effective way to improve system voltage drop. The suitable modeling of the electric railway system should be applied to the EMTP. the dynamic characteristics of 3-Phase Induction Motor in Electric Railway Systems is considered for precise modeling. it is shown through EMTP simulation using EMTP MODELS that voltage drop can be compensated effectively by STATCOM.

  • PDF

New Modeling of Switching Devices Considering Power Loss in Electromagnetic Transients Program Simulation

  • Kim, Seung-Tak;Park, Jung-Wook;Baek, Seung-Mook
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.592-601
    • /
    • 2016
  • This paper presents the modeling of insulated-gate bipolar transistor (IGBT) in electromagnetic transients program (EMTP) simulation for the reliable calculation of switching and conduction losses. The conventional approach considering the physical property of switching devices requires many attribute parameters and large computation efforts. In contrast, the proposed method uses the curve fitting and interpolation techniques based on typical switching waveforms and a user-defined component with variable resistances to capture the dynamic characteristics of IGBTs. Therefore, the simulation time can be efficiently reduced without losing the accuracy while avoiding the extremely small time step, which is required in simulation by the conventional method. The EMTP based simulation includes turn-on and turn-off transients of IGBT, saturation state, forward voltage of free-wheeling diode, and reverse recovery characteristics, etc. The effectiveness of proposed modeling for the EMTP simulation is verified by the comparison with experimental results obtained from practical implementation in hardware.