• Title/Summary/Keyword: EMTDC model

Search Result 235, Processing Time 0.022 seconds

Interaction and Transient Analysis to FACTS Devices in Seoul Area (수도권 FACTS 상호영향 및 과도특성 분석)

  • Yoon, Jong-Su;Kim, Jae-Han;Lee, Seong-Doo;Choi, Jang-Hum;Seo, Bo-Hyeok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1929-1935
    • /
    • 2010
  • This paper describes the operation effect of FACTS devices in the Korean power system. At the year of 2010, three FACTS devices is under commercial operation in the Seoul area. Among them, 345kV ${\pm}100MVA$ STATCOM at Mi-Geum substation and 345kV ${\pm}200MVA$ SVC at Dong-Seoul substation are very close at their electrical and geographical distance. Therefore, the additional analysis including interaction and mutual transient is necessary. Therefore, a detailed EMTDC/PSCAD simulation model was developed and steady-state/transient analysis was implemented.

Development of Simulation Model for Grid-tied Fuel-Cell Power Generation with Digital Controlled DC-DC Converter (디지털제어 DC-DC컨버터로 구성된 계통연계 연료전지발전 시뮬레이션모델 개발)

  • Ju, Young-Ah;Cha, Min-Young;Han, Byung-Moon;Kang, Tae-Sub;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1728-1734
    • /
    • 2009
  • This paper proposes a new power conditioning system for the fuel cell power generation, which consists of a ZVS DC-DC converter and 3-phase inverter. The ZVS DC-DC converter with a digital controller boosts the fuel cell voltage of 26-50V up to 400V, and the grid-tie inverter controls the active power delivered to the grid. The operation of proposed power conditioning system was verified through simulations with PSCAD/EMTDC software. The feasibility of hardware implementation was verified through experimental works with a laboratory prototype, which was built with 1.2kW PEM fuel-cell stack, 1kW DC-DC converter, and 3kW PWM inverter. The proposed system can be utilized to commercialize an interconnection system for the fuel-cell power generation.

A Study on Estimation Technique for Fault Location using Quadratic Interpolation in a Parallel Feeding AC Traction System (2차 보간법을 이용한 전기철도 급전계통의 고장점 산출 기법에 관한 연구)

  • Min, Myung-Hwan;An, Tae-Pung;Kwon, Sung-il;Jung, Hosung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.599-604
    • /
    • 2017
  • Nowadays reactance method is being used as a technique for fault location in parallel feeding AC traction power system. However, implementation of this method requires a large number of field tests(ground fault) which is a huge burden on the operators. This paper presents a new estimation technique using quadratic interpolation to reduce number of times for field test and improves the accuracy of fault location. To verify a new technique, we solve AT feeding circuit and model it using PSCAD/EMTDC. Finally this paper conducts a comparative analysis of usefulness between a new technique and real field data.

S-Domain Equivalent System for Electromagnetic Transient Studies PART II : Frequency Dependent AC System Equivalent (전자기 과도현상 해석을 위한 S 영역 등가시스템 PART II: 주파수 의존 교류 시스템 등가)

  • Chung Hyeng-Hwan;Wang Yong-Peel
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.4
    • /
    • pp.165-171
    • /
    • 2005
  • Electromagnetic transient simulation can be used to model complex non-linearities that very difficult to represent adequately in the frequency domain. This problem is greatly reduced with the use of frequency dependent network equivalents for the linear part of the system. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper presents the formulation for developing 2 port Frequency Dependent AC System Equivalent(FDACSE) with the instantaneous term in S-domain and illustrates its use. This 2 port FDNE have been applied to the New Zealand AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 2 port (FDACSE) developed with Norton Equivalent network. The study results have indicated the robustness and accuracy of 2 port FDACSE for electromagnetic transient studies.

Assessment of the Protection Algorithm Applied in Distributed Generations for Faults Occurred in the Interconnected Distribution Networks (외부 배전선 사고에 대한 분산전원 보호 알고리즘의 동작 수준 평가)

  • Jang, S.I.;Kim, S.G.;Park, Y.U.;Kim, K.H.;Choi, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.337-340
    • /
    • 2003
  • This paper describes the operational characteristics of protection algorithm applied in distributed generations(DG) for faults occurred in the interconnected distribution networks. The DG can be Influenced by abnormal grid conditions such as disturbances occurring in the neighboring distribution feeders as well as the interconnected power line. Particularly, in case of the fault happening in the neighboring distribution feeders emanated from the substation to which DG is connected, the protective devices in the DG might mis-operate. The mis-operation of protective devices can be varied by the fault conditions. The simulation results for Hoenggye substation model composed of five feeders using PSCAD/EMTDC showed that the number of mis-operation of protective devices applied in DG is about 0.66 times per one year.

  • PDF

An Application of Proportional-Resonant Controller in MMC-HVDC System under Unbalanced Voltage Conditions

  • Quach, Ngoc-Thinh;Ko, Ji-Han;Kim, Dong-Wan;Kim, Eel-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1746-1752
    • /
    • 2014
  • This paper presents an application of proportional-resonant (PR) current controllers in modular multilevel converter-high voltage direct current (MMC-HVDC) system under unbalanced voltage conditions. The ac currents are transformed and controlled in the stationary reference frame (${\alpha}{\beta}$-frame). Thus, the complex analysis of the positive and negative sequence components in the synchronous rotating reference frame (dq-frame) is not necessary. With this control method, the ac currents are kept balanced and the dc-link voltage is constant under the unbalanced voltage fault conditions. The simulation results based on a detailed PSCAD/EMTDC model confirm the effectiveness of the proposed control method.

Voltage Quality Analysis in Power Distribution System with Superconducting Fault Current Limiter at Grounding Line (초전도 한류기를 주변압기 접지선에 설치시 배전계통의 순간전압품질 분석)

  • Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.159-163
    • /
    • 2013
  • In this paper, voltage quality improvement is analyzed in case of Superconducting Fault Current Limiter (SFCL) installed in grounding line of main transformer in power distribution system. First, a resistive-type SFCL model is used. Next, Korean power distribution system is modeled. Finally, when SFCL is installed in the starting point of feeder and grounding line of main transformer, voltage qualities are evaluated according to various fault locations and resistance values of SFCL using PSCAD/EMTDC. The voltage quality results in case of grounding line are compared with the voltage in case of feeder.

Active and Reactive Power Compensator for Wind Power System with Squirrel-Cage Induction Generator (농형유도 풍력발전시스템을 위한 유.무효전력보상장치)

  • Yang, Seung-Chul;Ju, Young-Ah;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.48-50
    • /
    • 2008
  • A wind power system with squirrel-cage induction generator has irregular change of output power according to the sudden change of wind speed. This paper describes the development of a active and reactive power compensator, which is composed of a 3-phase inverter and a bidirectional DC/DC converter with super-capacitor. The operational characteristic was analyzed through simulations with PSCAD/EMTDC and experimental works with a scaled model. The developed system can continuously compensate the active power change with energy storage and the reactive power change with 3-phase inverter.

  • PDF

Redundancy Module Operation Analysis of MMC using Scaled Hardware Model (축소모형을 이용한 MMC의 Redundancy Module 동작 분석)

  • yoo, Seung-Hwan;Jeong, Jong-Kyou;Hong, Jung-Won;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.209-210
    • /
    • 2014
  • In this paper, a hardware prototype for the 10kVA 11-level MMC was built and various experimental works were conducted to verify the operation algorithms of MMC. The hardware prototype was designed using computer simulation with PSCAD/EMTDC software. After manufactured in the lab, the hardware prototype was tested to verify the modulation algorithms to form the output voltage, the balancing algorithm to equalize the sub-module capacitor voltage, and the redundancy operation algorithm to improve the system reliability.

  • PDF

Implementation of Accelerated Model for Modular Multilevel Converter Based HVDC System to reduce simulation operation time (시뮬레이션 연산시간 단축을 위한 MMC HVDC 시스템의 가속모델 구현)

  • Lee, Byung-hyuk;Kim, Si-hwan;Kim, Tae-Jin;Kim, Rae-young
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.389-390
    • /
    • 2014
  • 고압직류송전 (High Voltage Direct Current, HVDC) 시스템의 모듈형 멀티레벨 컨버터 (Modular Multilevel Converter, MMC)는 EMT (Electromagnetic Transients) 시뮬레이션으로 구현 시 많은 연산시간을 요구하므로 시간 단축을 위한 가속설계가 반드시 필요하다. 본 논문에서는 스위칭 함수를 이용한 등가 모델을 이용하여 각 암을 하나의 전압원으로 단순화하였다. 본 가속모델의 유효성을 검증하기 위해 PSCAD/EMTDC에서 제공하는 반도체 스위치를 이용한 모델과 비교하여 시뮬레이션 수행시간을 비교하였다.

  • PDF