• Title/Summary/Keyword: EMI receiver

Search Result 21, Processing Time 0.032 seconds

Research of the EMI Test Methods for a Surveillance Radar Subsystem Against the Intermodulation and Undesired Signals (상호 변조 및 불요 신호에 대한 탐색레이더 부 체계의 EMI 시험 기법)

  • Lee, Jin-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.84-89
    • /
    • 2007
  • MIL-STD-461E, EMI military standard for the equipment and subsystems, requires reception characteristic tests to verify the susceptibility of a receiver against the jntermodulation and spurious signals. Because the CS103 and CS104 of MIL-STD-461E show the test configuration of the equipment unit like a traditional receiver, it is possible to verify the susceptibility only for the reception signal through analog filters. However, at present when software programming techniques make a progress, the CS103 and CS104 tests need to evaluate the reception signal of the subsystem which includes both the digital filtering effects and analog filter characteristics. These test and evaluation techniques applied to a surveillance radar subsystem. This paper researched the EMI test methods in order to confirm feasibility of these test and evaluation techniques. Also the test results are compared and analyzed.

Engineering Qualification Model Development of S-band Receiver for STSAT-3 (과학기술위성 3호 S 대역 수신기 기술인증모델 개발)

  • Lee, Jung-Su;Oh, Seung-Han;Seo, Gyu-Jae;Oh, Chi-Wook;Myung, Noh-Hoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.6
    • /
    • pp.609-614
    • /
    • 2009
  • The TT&C communication subsystem of STSAT-3 is consisted of communication link to send telemetry data of spacecraft to the ground station and receive command data from ground station. The S-band receiver is used to receive command data from ground station, Engineering Qualification Model of S-band receiver has been designed and manufactured. The Designed S-band Receiver uses a single conversion for a simple frequency conversion, including a DC-DC Converter and EMI Filter. Also, Digital demodulation part designed using FPGA and RS-422 data interface. The performance of S-band Receiver in functional and space environments test satisfies the requirements of STSAT-3.

The EMI Noise Reduction Circuit with Random Number Generator (랜덤 수 생성 회로를 이용한 EMI Noise 저감 회로)

  • Kim, Sung Jin;Park, Ju Hyun;Kim, SangYun;Koo, Ja Hyun;Kim, Hyung il;Lee, Kang-Yoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.9
    • /
    • pp.798-805
    • /
    • 2015
  • This paper proposes Relaxation Oscillator with Random Number Generator to minimize electromagnetic interference (EMI) noise. DC-DC Converter with Relaxation Oscillator is presented how much spurious noise effects to RF Receiver system. The main frequency of the proposed Relaxation oscillator is 7.9 MHz to operate it and add temperature compensation block to be applied to the frequency compensation in response to temperature changes. The DC-DC Converter Spurious noise is reduced up to 20 dB through changing frequency randomly. It is fabricated in $0.18{\mu}m$ CMOS technology. The active area occupies an area of $220{\mu}m{\times}280{\mu}m$. The supply voltage is 1.8 V and current consumption is $500{\mu}A$.

PanelLink Digital Flat Panel Display Receiver for TFT LCD Test (TFT LCD 검사용 패널링크 디지털 플랫 패널 디스플레이 수신부 구현)

  • Baek, Woon-Sung;Lee, Seon-Bok;Park, Chang-Soo;Hong, Cheol-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.618-620
    • /
    • 1998
  • We implemented PanelLink flat panel display receiver which can be used for testing SXGA($1280{\times}1024$) TFT LCD panel. We've got optimal analog input voltage to get stable image according to cable length. And we commented the way to reduce EMI.

  • PDF

Analysis of Electromagnetic Wave Absorbers for Applying Magnetic Levitation (자기부상체 적용을 위한 전자파 흡수체의 특성 분석)

  • Seo, Yong-beom;Kang, Hyun-il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • EMC (Electro Magnetic Compatibility) of the electrical railway must be ensured for safety of passenger. Maglev trains has not friction between the wheels and the rails because levitation by an permanent magnets, electromagnets and superconducting magnets etc. So, it is advantageous to maintain a high speed without noise and vibrations. In this paper, we investigated that the magnetic field of the before and after installation electromagnetic waves absorber in order to analyze the effects of electromagnetic waves. The theoretical analysis of the electromagnetic wave absorber was simulated using finite element method. The magnetic field properties of electromagnetic waves absorber were measured by EMI (Electro Magnetic Interference) test receiver.

Development of a GPS Receiver System for Satellite Launch Vehicles (위성발사체용 GPS 수신기 시스템의 개발)

  • Kwon, Byung-Moon;Moon, Ji-Hyeon;Shin, Yong-Sul;Choi, Hyung-Don;Cho, Gwang-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.9
    • /
    • pp.929-937
    • /
    • 2008
  • A GPS receiver system utilized on satellite launch vehicles should operate normally under harsh environments as well as high-dynamic conditions. The GPS receiver system to use for range safety of KSLV(Korea Space Launch Vehicle)-I that is the first satellite launch vehicle developed by KARI(Korea Aerospace Research Institute) has been confirmed to survive under the environment of the launcher through extensive terrestrial tests including humidity, high and low temperatures, vacuum, sinusoidal and random vibrations, shocks, acceleration, EMI/EMC(Electromagnetic Interference/ Electromagnetic Compatibility), etc. Several performance tests have been also carried out in order to evaluate tracking capability and accuracy of the GPS receiver under high-dynamic conditions using a GPS signal simulator. Some lessons-learned during development of the GPS receiver system and its special characteristics compared with COTS(Commercial-Off-The-Shelf) GPS receiver systems are described in this paper.

Corona generated Radio Interference of the 750 kV AC Bundle Conductors in Sandy and Dusty Weather Condition in the High Altitude Area

  • Liu, Yun-Peng;Zhu, Lei;Lv, Fang-Cheng;Wan, Bao-Quan;Pei, Chun-Ming
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1704-1711
    • /
    • 2014
  • Sandy and dusty weather condition often occurs in the high altitude areas of China, which may greatly influence the corona generated radio interference (RI) characteristics of the bundle conductors of 750 kV AC power transmission lines. Corona generated RI of the conductors of the 750 kV AC power transmission lines used in practice is measured by EMI receiver with a coupling circuit and a coupling capacitor connected between the high voltage side and the earth side in fine and sandy and dusty condition. The measuring frequency is 0.5 MHz, and the quasi-peak detection is used. RI excitation function is calculated based on the corona RI current measured by the EMI receiver. Corona generated RI characteristics were analyzed from sand concentration and sand particle size. The test result shows that the corona generated RI excitation function is influenced by the sandy and dusty condition. Corona discharge of the conductors is more serious in sandy and dusty condition with an ultraviolet (UV) detector. Corona generated RI excitation function increases with the increase of sand concentration and also increases with the increase of particle size.

KoDSat System Level EMC(Electro Magnetic Compatibility) Test and an Analysis of the Test Results (검증위성 시스템레벨 전자기파(EMC) 시험 및 결과에 대한 분석)

  • Seo, Min-Seok;Park, Seok-Jun;Sim, Eun-Seop;Kim, Se-Yeon;Chae, Jang-Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.102-109
    • /
    • 2006
  • In this paper, the system level EMC radiated emission test results of KoDSat(Korea Demonstration Satellite), its affects upon the Launch vehicle and H/W improving methods regarding its over exceed value of EMC specification are discussed. Regarding its over exceed value, we estimated that DAU of KoDSat generated the exceeded EMC noise source, and these test results were analyzed using the EMC2000 tool to find out how did it affect the FTS(Flight Termination Subsystem) of KSLV-1(Korea Small Launch Vehicle). To diminish the EMC noise source of UHF(430.1Mhz) band level, we redesigned the DAU power board to be applied the various schemes for EMI noise reduction such as grounding, shielding and EMI filtering, and also verified these reworks to analyze its diminishing affects in UHF band level by means of performing the DAU box level EMC test and performing the second KoDSat's system level EMC test.

Investigation of a Method for RF Circuits Analysis Based on Electromagnetic Topology

  • Park, Yoon-Mi;Chung, Young-Seek;Cheon, Chang-Yul;Jung, Hyun-Kyo
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.396-400
    • /
    • 2009
  • In this paper, electromagnetic topology (EMT) was used to analyze the electromagnetic compatibility (EMC) of RF circuits including passive and active components. It is difficult to obtain usable results for problems relating to electromagnetic coupling in complex systems when using conventional numerical or experimental methods. Thus it is necessary to find a new methodology for analyzing EMC problems in complicated electromagnetic environments. In order to consider the nonlinear characteristics of active components, a SPICE diode model was used. A power detector circuit and the receiver circuit of a radio control (RC) car were analyzed and experimented in order to verify the validity of this method.

Dosimetry for Resonance-Based Wireless Power Transfer Charging of Electric Vehicles

  • Park, Sang-Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.129-133
    • /
    • 2015
  • This paper presents the dosimetry of a resonance-based wireless power transfer (RBWPT) system for electric vehicles applications. The compact RBWPT system is designed to transfer power at 150-mm distance. The electric and magnetic fields generated by the RBWPT system and the specific absorption rate in the human body model, which stands around the system, are calculated. These analyses are conducted in two cases: the alignment and the misalignment between the transmitter and the receiver. The matching loops are adjusted to maximize the power transfer efficiency of the RBWPT system for the misalignment condition. When the two cases were compared for the best power transfer efficiency, the specific absorption rates (SAR) in the misalignment case were larger than those in the alignment case. The dosimetric results are discussed in relation to the international safety guidelines.