• Title/Summary/Keyword: EMI measurement.

Search Result 121, Processing Time 0.021 seconds

Effects of PCB Patterns on EMI Measurement in TEM Cell and Proposal of PCB Design Guidelines (TEM 셀에서 PCB 패턴이 EMI 측정에 미치는 영향 및 PCB 설계 가이드라인 제시)

  • Choi, Minkyoung;Shin, Youngsan;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.21 no.3
    • /
    • pp.272-275
    • /
    • 2017
  • Recently, semiconductor integration density enormously increases and its interconnection width is significantly narrowed, which leads to EMI (electromagnetic interference) problems on chip level. Chip manufacturer exploits TEM cell (transverse electromagnetic cell) to measure EMI on chip level, which requires PCB (printed circuit board) for measurement purpose. However, it is often neglected to consider that PCB patterns and other factors can affect on EMI measurement. In this paper, several test patterns are designed for different PCB design variables, and effects of PCB patterns on EMI measurement in TEM cell are analyzed. Based on these analyses, PCB design guidelines are also proposed to minimize the effects on EMI measurements.

A Study on Searching Stabled EMI Shielding Effectiveness Measurement Point for Military Communication Shelter Using Support Vector Machine and Process Capability Analysis (서포트 벡터 머신과 공정능력분석을 이용한 군 통신 쉘터의 EMI 차폐효과 안정 포인트 탐색 연구)

  • Ku, Ki-Beom;Kwon, Jae-Wook;Jin, Hong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.321-328
    • /
    • 2019
  • A military shelter for communication and information is necessary to optimize the integrated combat ability of weapon systems in the network centric warfare. Therefore, the military shelter is required for EMI shielding performance. This study examines the stable measurement points for EMI shielding effectiveness of a military shelter for communication and information. The measurement points were found by analyzing the EMI shielding effectiveness measurement data with data mining technique and process capability analysis. First, a support vector machine was used to separate the measurement point that has stable EMI shielding effectiveness according to set condition. Second, this process was conducted with process capability analysis. Finally, the results of data mining technique were compared with those of process capability analysis. As a result, 24 measurement points with stable EMI shielding effectiveness were found.

Measurement Uncertainty for Calibration of EMI Dipole Antenna from 30 MHz to 1 GHz (30 MHz에서 1 GHz 대역 EMI 측정용 다이폴안테나 교정의 측정 불확도)

  • Park, Jung-Kuy;Jeong, Dong-Chan;Cho, Jin-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.166-176
    • /
    • 2007
  • Measurement uncertainty assessment is very important in measurement and calibration. RRL provides antenna calibration services for EMI test. Reliability of EMI test depends on accurate antenna calibration. Antenna calibration results have to be accompanied with measurement uncertainty for its better reliability. In the late of 2005, CISPR issued the CISPR/A/644/C which describes the antenna calibration and measurement uncertainty. In this paper, on the basis of CISPR/A/644/C, we provide the measurement uncertainty values for dipole antenna calibration at the Calibration Test Site(CALTS) of Icheon. The antenna calibration method is 3-antenna height-scanning-averaging method, which measures the free-space antenna factor. We also considered all uncertainty sources that can affect measurement results during calibration.

Scattering Parameter-based Measurement of Planar EMI filter

  • Wang, Shishan;Gong, Min;Xu, Chenchen
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.806-813
    • /
    • 2014
  • Planar electromagnetic interference (EMI) filters are widely used to restrain the conducted EMI of switching power supplies. Such filters are characterized by small size, low parasitic parameters, and better high-frequency performance than the passive discrete EMI filter. However, EMI filter performance cannot be exactly predicted by using existing methods. Therefore, this paper proposes a method to use scattering parameters (S-parameters) for the measurement of EMI filter performance. A planar EMI filter sample is established. From this sample, the relationship between S-parameters and insertion gain (IG) of EMI filter is derived. To determine the IG under different impedances, the EMI filter is theoretically calculated and practically measured. The differential structure of the near-field coupling model is also deduced, and the IG is calculated under standard impedance conditions. The calculated results and actual measurements are compared to verify the feasibility of the theory.

Modeling and Design Algorithm of Conducted EMI Filter Using a Noise Separation Method (노이즈 분리 기법을 이용한 진도EMI 필터의 모델링 및 설계 알고리즘)

  • 정용채
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.260-266
    • /
    • 2004
  • Because the EMI filter is mainly designed by trial and error method, it takes many times to reduce the conducted EMI noise in a power converter. Thus, a newly analytical design procedure is proposed to overcome the problem in this paper. High frequency models of each component are built, md, using the modeling circuits, the filter design is carried out applicable to each mode. Based on the accumulated database for practical components, and the measurement data of EUT with a standard filter, the filler design algorithm is presented. Finally, the validity of the Proposed models and design method is verified through the measurement results.

An Accurate Method to measure Shielding Effectiveness of EMI Spray Coating Film (EMI 스프레이 코팅막의 차폐효과를 측정하기 위한 정확한 방법)

  • Hur, Jung;Lee, Won-Hui
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.79-83
    • /
    • 2018
  • An accurate method to measure shielding effectiveness(SE) of EMI spray coating film is presented. After high frequency simulating, Circular coaxial standard test fixture is fabricated. A sample of EMI spray coating film was fabricated for insertion into a circular coaxial standard test fixture. The measuring instrument used an Agilent 8722ES vector network analyzer for the SE measurement. The exact SE of copper and silver mixed spray coating sample was measured by the composition of the measuring instrument and the measuring sample. The SE of copper sample was measured at 70 dB and the SE of copper and silver mixed spray coating sample was measured at 60 dB. As a result of the measurement, the reliability of the circular coaxial standard test fixture was confirmed.

Modeling of EMI Source Using Inverse Techniques (역산 기법을 이용한 EMI Source의 모델링)

  • Im, Chang-Hwan;Jung, Hyun-Kyo;Kim, Hyeong-Seok;Lee, Jeong-Hae
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.1
    • /
    • pp.37-44
    • /
    • 2003
  • In this paper, a technique to estimate EMI source distribution on a digital circuit board ir introduced. A sensitivity analysis method is applied to reconstruct the source distribution from measured electric field data. Results from a single-layer measurement and a double-layer measurement are compared. It will be shown, from the simulation, that the use of sensitivity analysis for the EMI source reconstruction problem can be a very promising technique.

  • PDF

Modeling of EMI Source Using Inverse Techniques (역산 기법을 이용한 EMI Source의 모델링)

  • Im Chang-Hwan;Jung Hyun-Kyo;Kim Hyeong-Seok;Lee Jeong-Hae
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.6-9
    • /
    • 2002
  • In this paper a technique to estimate EMI source distribution on a digital circuit board is introduced. A sensitivity analysis method is applied to reconstruct the source distribution from measured electric field data. Results from a single-layer measurement and a double-layer measurement are compared. It will be shown, from the simulation, that the use of sensitivity analysis for the EMI source reconstruction problem can be a very promising technique.

  • PDF

Design of Low Pass Filter to reduce EMI from 2.SG SDH system (2.5G SDH 전자파 감소용 저역통과필터 설계)

  • 이성원;김영범
    • Journal of the Korea Society for Simulation
    • /
    • v.10 no.4
    • /
    • pp.21-30
    • /
    • 2001
  • In this paper, EMI measurement, the STGU simulation being conducted, filter design, its characteristics, and its implementation to the PCB, and finally test results are discussed. When the low pass filter was implemented within the STGU, the power of EMI decreased more than 20dBm. Finally, when TE and MTIE, two important quality measure in synchronous reference clock, was assessed, ITU-T G813 requirement was satisfied. EMI(Electromagnetic Interface) is a measure of electomagnetic radiation from equipment in the range of 10KHz to 3GHz, and can cause unexpected reactions of electronics/electrical equipment. In this study, for safe and stable communication operation, a STGU (System Timing Generation Unit), which is a 2.5G SDH System and a major EMI source, was employed to simulate electromagnetic interface. Using Open-Site test, the power of fundamental frequency of EMI of interest and its harmonics were measured. Also, a low pass filter at cut-off frequency of 2GHz was specifically designed for this study to minimize the effect of EMI between electronic components.

  • PDF

The Reduction Method for Radiated EMI in USB Power Line of Cable (USB 케이블의 전원선 에서의 방사성 EMI 개선)

  • Park, Kyoung-Jin;Lee, Dae-Woo;Ko, Yong-Mok;Gang, Eun-Gyun;Park, Jong-Hyun;Kim, Keun-Yong;Ra, Keuk-Whan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.201-208
    • /
    • 2013
  • In this paper, we studied on improvement for radiated EMI of USB power line of cable. it is made by using wireless video access point system for confirming the phenomenon of radiated EMI from cable. then, we make sure that the limit exceed through the initial measurement of radiated EMI limit criteria in comparison to about 3 [dBuV/m]~15 [dBuV/m]. after that we confirmed the resonance in power line of cable through measurement of s-parameters. so, we confirmed the relation radiated EMI and power line of cable resonance and we reduced radiated EMI in power line of cable through a capacitor and low pass-band filter using the technique of power networks management. in conclusion, we suggested how to reduce power line of cable resonance applied for the improved method. and we confirmed that suggested reduction method is suitable through testing radiated EMI. the result of radiated EMI reduction limit criteria 40[dBuV/m]~47[dBuV/m] in comparison to about 3 [dBuV/m]~20 [dBuV/m].