• Title/Summary/Keyword: EMI Filter

Search Result 130, Processing Time 0.026 seconds

Equivalent Parallel Capacitance Cancellation of Common Mode Chokes Using Negative Impedance Converter for Common Mode Noise Reduction

  • Dong, Guangdong;Zhang, Fanghua
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1326-1335
    • /
    • 2019
  • Common mode (CM) chokes are a crucial part in EMI filters for mitigating the electromagnetic interference (EMI) of switched-mode power supplies (SMPS) and for meeting electromagnetic compatibility standards. However, the parasitic capacitances of a CM choke deteriorate its high frequency filtering performance, which results in increases in the design cycle and cost of EMI filters. Therefore, this paper introduces a negative capacitance generated by a negative impedance converter (NIC) to cancel the influence of equivalent parallel capacitance (EPC). In this paper, based on a CM choke equivalent circuit, the EPCs of CM choke windings are accurately calculated by measuring their impedance. The negative capacitance is designed quantitatively and the EPC cancellation mechanisms are analyzed. The impedance of the CM choke in parallel with negative capacitances is tested and compared with the original CM choke using an impedance analyzer. Moreover, a CL type CM filter is added to a fabricated NIC prototype, and the insertion loss of the prototype is measured to verify the cancellation effect. The prototype is applied to a power converter to test the CM conducted noise. Both small signal and EMI measurement results show that the proposed technique can effectively cancel the EPCs and improve the CM filter's high frequency filtering performance.

A Study on the EMI Signal Analysis and Denoising Using a Wavelet Transform (웨이브렛 변환을 이용한 EMI 신호해석 및 잡음제거에 관한 연구)

  • 윤기방;박제헌;김기두
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.3
    • /
    • pp.37-45
    • /
    • 1998
  • In this paper, the different frequency component and time informations from an EMI signal are extracted simultaneously using a wavelet transform and the results of transform in the time and frequency domain are analyzed. Frequencies are extracted from the EMI signal by performing the multiresolution analysis using the Daubechies-4 filter coefficients and the time information through the results of wavelet transform. We have tried the correlation analysis to evaluate the results of wavelet transform. We have chosen the optimal wavelet function for an object signal by comparing the transformed results of various wavelet functions and verified the simulation examples of waveform and harmonic analysis using a wavelet transform. We have proved the denoising effect to the EMI signal using the soft thresholding technique.

  • PDF

Analysis of EMI filter effect in Arc-Fault detection (EMI필터가 아크사고검출에 미치는 영향 분석)

  • Choi, Su-Kyung;Kwon, Wan-Sung;Kim, Chong-Min;Bang, Sun-Bae;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.119-120
    • /
    • 2010
  • 일반적으로 전선이 낡고 오래되거나 또는 강한 열이나 외부적 충격 등에 의해서 절연이 파괴된 경우 전기화재의 원인이 되는 아크 현상이 발생한다. 이러한 아크 사고는 Arc Fault Circuit Interrupter (AFCI)를 통해 예방할 수 있다. UL1699규정은 AFCI의 성능 시험을 위한 규정으로 구체적인 여러 성능 시험을 제시하고 있다. 그 중 EMI 필터 시험에 대한 부분을 한국의 전기 배선에 맞게 재구성하여 실험하고, 아크 검출에 EMI 필터가 어떤 영향을 미치는지 분석하여 UL에서 제시한 EMI 필터 시험의 타당성을 검증한다.

  • PDF

Design of EMI Filter using the Extract of Noise Source Impedance (노이즈 소스 임피던스 추출 방식을 이용한 EMI 필터 설계)

  • Won, Do-Hyun;Kim, Hee-Seung;Baek, Mi-Ran;Han, Sang-Kyoo;Roh, Chung-Wook;Won, Jae-Sun;Oh, Dong-Seong;Hong, Sung-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.462-463
    • /
    • 2010
  • 기존의 EMI 필터 설계 방식은 많은 가정을 전제로 설계되어 다양한 종류의 컨버터에 적용하기 어렵고, 특정 컨버터에만 적용할 수 있는 문제점이 있다. 이를 해결하기 위해 본 논문에서는 측정 대상 시료의 노이즈 원과 노이즈 소스 임피던스를 등가회로로 모델링한 후 EMI 필터에 사용되는 소자의 임피던스 모델을 이용하여 노이즈 소스 임피던스를 유추한다. 이를 이용하여 모든 컨버터에 적용될 수 있는 EMI 필터 설계 방법을 제시한다. 최종적으로 각 단계에서 실제 측정 결과 및 모의실험 결과를 제시하여 제안 방식의 타당성 및 유용성을 검증하였다.

  • PDF

Implementation of Dedicated Power Line Filter for HEMP Protection (HEMP 보호용 전원선 필터 구현)

  • Kim, Keun-Nam;Lee, Sung-Hwa;Kim, Jin-Tae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.47-52
    • /
    • 2016
  • This paper covers the importance of a dedicated Power Line Filter implementation against HEMP(High altitude ElectroMagnetic Pulse) threats caused by high altitude nuclear detonations. As the PCI test results for E1 short pulse with 2500[A], only HEMP filter obtained the required residual current around 8[A], but others didn't meet below 10[A] on MIL-STD-188-125 PCI regulation. Consequently, the development of a dedicated power line filter turned out to be a essential element in order to protect the power related system against HEMP transient.

Research of the EMI Test Methods for a Surveillance Radar Subsystem Against the Intermodulation and Undesired Signals (상호 변조 및 불요 신호에 대한 탐색레이더 부 체계의 EMI 시험 기법)

  • Lee, Jin-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.84-89
    • /
    • 2007
  • MIL-STD-461E, EMI military standard for the equipment and subsystems, requires reception characteristic tests to verify the susceptibility of a receiver against the jntermodulation and spurious signals. Because the CS103 and CS104 of MIL-STD-461E show the test configuration of the equipment unit like a traditional receiver, it is possible to verify the susceptibility only for the reception signal through analog filters. However, at present when software programming techniques make a progress, the CS103 and CS104 tests need to evaluate the reception signal of the subsystem which includes both the digital filtering effects and analog filter characteristics. These test and evaluation techniques applied to a surveillance radar subsystem. This paper researched the EMI test methods in order to confirm feasibility of these test and evaluation techniques. Also the test results are compared and analyzed.

Harmonic Analysis of Three-Phase Diode Rectifier and Measurement of Conducted EMI Emission Using LISN (3상 다이오드 정류기의 고조파 해석 및 LISN을 이용한 노이즈 측정에 관한 연구)

  • Chae, Y.M.;Choe, G.H.;Mok, H.S.;Lee, E.W.;Hong, S.C.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.212-215
    • /
    • 1995
  • In this paper, The characteristic of Harmonic spectrum is studied for generally used three-phase diode rectifier. and filter design criteria is showen in the sense of THD, DPF, and PF. As the becoming of Automative and informative era, the demand of critical and stable control becomes more and more important. But much EMI emissions are generated for more critical and stable control in power electronic system these EMI emissions can be measured using LISN(Line Impedance Stabilization Network). So we are to investigate the behavior of Conducted EMI emission in Diode Rectifiers using LISN in frequency domain.

  • PDF

A Study on the Characteristic Analysis of Hybrid Choke Coil suitable for LED-TV SMPS (LED-TV용(用) 전원장치에 적합한 Hybrid 초크 코일의 특성 해석에 관한 연구)

  • Kim, Jong-Hae;Kim, Hee-Sung;Won, Jae-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.32-43
    • /
    • 2014
  • This paper presents the intra capacitance modeling according to the winding method, section bobbin and coil structure for hybrid choke coil capable of the EMI attenuation of broad bands from lower frequency bands to higher frequency bands and high frequency type common-mode choke coil capable of the EMI attenuation of high frequency band used in the EMI Block of LED-TV SMPS. In case of high frequency type CM choke coil, it can be explained the parasitic capacitance of A type and section bobbin type winding methods among them is much smaller than the other. The first resonant frequency of the proposed CM choke coil tends to increase as the parasitic capacitance becomes small and its impedance characteristics also show improved performance as the first resonant frequency increases. In case of hybrid choke coil using rectangular copper wire, it has investigated its parasitic capacitance compared to CM choke coil of conventional toroidal type becomes small. Also it has confirmed through the experiment results that CE margin and RE margin in frequency bands 0.5MHz to 5MHz and 30MHz to 200MHz are respectively 10dB and 15dB greater than that of conventional type in case of one stage EMI filter structure adopting hybrid choke coil compared to two stage EMI Filter structure using two of each CM choke coil used in the lower and higher frequency bands or two of CM choke coil used in only the lower frequency bands. In the future, the hybrid choke coil and CM choke coil of high frequency type show it can be practically used in not only LED/LCD-TV SMPS but also several applications such as LED Lighting, Laptop Adapter, Server Power Supply and so on.