• Title/Summary/Keyword: EMG-measurement

Search Result 175, Processing Time 0.022 seconds

Effect of 1-RM Direct Measurement Method on Beginners' Back Squat (1-RM 직접측정법이 초보자의 백스쿼트에 미치는 영향 )

  • Jaeho, Kim;Sukhoon, Yoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.4
    • /
    • pp.134-140
    • /
    • 2022
  • Objective: This study aims to verify effect of 1-RM direct measurement method of back squat on beginners. Method: Total of 8 healthy adults were recruited for this study (age: 29 ± 3.81 yrs., height: 174 ± 3.83 cm., body mass: 74 ± 11.63 kg., 1RM: 96 ± 19.78 kg). All participants performed the back squat with 80%, 90% and 100% of the pre-measured 1RM. A three-dimensional motion analysis was performed with 8 infrared cameras and 3 channels of EMG were used for this study. One-way ANOVA with repeated measure was used for the statistical analysis with the significant level set to α=.05. Results: The ankle joint ROM in the transverse plane was significantly increased as the weight increased during the concentric contraction phase 2 (p < .05). In addition, the erector spinae and the gluteus maximus, which are synergist for the motion, showed a significant difference according to the increased weight (p < .05). Conclusion: Our results revealed that beginners increase potential dynamic knee valgus as weight increased. Therefore, it is thought that field coaches should pay attention to this to minimize and prevent injuries when measuring 1-RM for beginners.

Development of an Intelligent Ankle Assistive Robot (지능형 발목 근력 보조 로봇의 개발)

  • Jeong, Woo-Chul;Kim, Chang-Soon;Park, Jin-Yong;Hyun, Jung-Guen;Kim, Jung-Yup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.6
    • /
    • pp.538-546
    • /
    • 2015
  • This paper describes an intelligent ankle assistive robot which provides assistive power to reduce ankle torque based on an analysis of ankle motion and muscle patterns during walking on level and sloped floors. The developed robot can assist ankle muscle power by driving an electric geared motor at the exact timing through the use of an accelerometer that detects gait phase and period, and a potentiometer to measure floor slope angle. A simple muscle assistive link mechanism is proposed to convert the motor torque into the foot assistive force. In particular, this mechanism doesn't restrain the wearer's ankle joint; hence, there is no danger of injury if the motor malfunctions. During walking, the link mechanism pushes down the top of the foot to assist the ankle torque, and it can also lift the foot by inversely driving the linkage, so this robot is useful for foot drop patients. The developed robot and control algorithm are experimentally verified through walking experiments and EMG (Electromyography) measurements.

Changes in Median Frequency of Quadriceps Muscle According to Application Modes of Neuromuscular Electrical Stimulation (신경근전기자극 적용양식에 따른 대퇴사두근의 중앙주파수 변화)

  • Choi, Soo-Hee;Oh, Myung-Hwa;Kim, Tae-Youl;Jeong, Jin-Gyu
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.3 no.1
    • /
    • pp.49-59
    • /
    • 2005
  • This study assigns each 8 of 24 normal persons to control group(Group I), strength increase group(Group II) and endurance increase group(Group III) to analyze differences in changes of strength and endurance with surface electromyography and kinetics according to application modes of neuromuscular electrical stimulation(NMES). Group I had not any treatment, group II performed 15 repeated contraction with 60% intensity of maximal voluntary isometric contraction(MVIC) by setting 10-sec on time and 50-sec off time and group III conducted 30 repeated contraction with 30% intensity of MVIC by setting 10-sec on time and 20-sec off time. For neuromuscular electrical stimulation, 2,500 Hz of Russian current, 35 pps of pulse rate and 200 of pulse width. Neuromuscular electrical stimulation was conducted by five times for total 4 weeks. Before and after experimentmotor unit action potential of vastus medialis, rectus femoris and vastus lateralis were measured with sEMG, median frequency(MDF) was analyzed, and thus the following results were obtained. There was significant difference in the period of measuring vastus medialis and rectus femoris in change of MDF and interaction among groups with analysis of surface electromyography before and after neuromuscular electrical stimulation(p<.001) and in particular, there was a remarkable change among groups according to the period of measurement. In conclusion, NMES influenced changes of strength and endurance according to its application modes and in particular, it was found that strength increment application had a significant influence on strength increment in applying short-time NMES.

  • PDF

Comparison of immediate complete denture, tooth and implant-supported overdenture on vertical dimension and muscle activity

  • Shah, Farhan Khalid;Gebreel, Ashraf;Elshokouki, Ali Hamed;Habib, Ahmed Ali;Porwal, Amit
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.61-71
    • /
    • 2012
  • PURPOSE. To compare the changes in the occlusal vertical dimension, activity of masseter muscles and biting force after insertion of immediate denture constructed with conventional, tooth-supported and Implant-supported immediate mandibular complete denture. MATERIALS AND METHODS. Patients were selected and treatment was carried out with all the three different concepts i.e, immediate denture constructed with conventional (Group A), tooth-supported (Group B) and Implant-supported (Group C) immediate mandibular complete dentures. Parameters of evaluation and comparison were occlusal vertical dimension measured by radiograph (at three different time intervals), Masseter muscle electromyographic (EMG) measurement by EMG analysis (at three different positions of jaws) and bite force measured by force transducer (at two different time intervals). The obtained data were statistically analyzed by using ANOVA-F test at 5% level of significance. If the F test was significant, Least Significant Difference test was performed to test further significant differences between variables. RESULTS. Comparison between mean differences in occlusal vertical dimension for tested groups showed that it was only statistically significant at 1 year after immediate dentures insertion. Comparison between mean differences in wavelet packet coefficients of the electromyographic signals of masseter muscles for tested groups was not significant at rest position, but significant at initial contact position and maximum voluntary clench position. Comparison between mean differences in maximum biting force for tested groups was not statistically significant at 5% level of significance. CONCLUSION. Immediate complete overdentures whether tooth or implant supported prosthesis is recommended than totally mucosal supported prosthesis.

Development of a Chest-wearable Walking Rehabilitation Robot (가슴 착용형 보행 재활로봇의 개발)

  • Kim, Hyun;Kwon, Jeong-Gwan;Song, Sang-Young;Kang, Seok-Il;Kim, Jung-Yup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.5
    • /
    • pp.393-400
    • /
    • 2015
  • This paper describes the development of a chest-wearable robot that can efficiently perform self walking rehabilitation without a helper. The features of the developed robot are divided into three parts. First, as a mechanical characteristic, the conventional elbow crutch is attached at the forearm. However, the proposed robot is attached to the patient's chest, enabling them to feel free to use their hands and eliminate the burden of the arms. Second, as a characteristic of the driving algorithm, pressure sensors attached to the chest automatically perceive the patient's walking intention and move the robot-leg thereafter. Also, for safety, it stops operating when an obstacle is found in front of the patient by using ultrasonic sensors and generates a beeping sound. Finally, by using the scotch yoke mechanism, supporting legs are moved up and down using a rotary servo motor without excessive torque that is generated by large ground reaction forces. We showed that the developed robot can effectively perform self walking rehabilitation through walking experiments, and its performance was verified using Electromyograph (EMG) sensors.

Comparison of the Maximal Muscular Activities of the Deltoid During Shoulder Abductions in Patients with Adhesive Capsulitis (유착성 관절낭염 환자의 어깨벌림 각도에 따른 중간어깨세모근의 최대근활성도 비교)

  • Song, Il-Gyu;Lee, Han-Suk;Park, Sun-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.4
    • /
    • pp.65-70
    • /
    • 2016
  • PURPOSE: This study aimed to compare the electromyography (EMG) activity for the middle deltoid (MD) and upper trapezius (UT) muscles in various shoulder abduction angles in patients with adhesive capsulitis (AC). METHODS: A total of 15 subjects participated in the study: 6 without AC (control group) and 9 with AC (AC group). The muscle activities of the UT and MD were measured using EMG during maximal static shoulder abductions in both groups. Each subject performed three repetitions of horizontal abduction at $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, and $90^{\circ}$ of the shoulder abduction angle in a sitting position. The measurement data from the middle 3-seconds of the 5-second periods were used. The mean value of three separate sets of measurements was used in the data analysis. For each muscle, independent t-tests were performed to determine group differences. A measured repeated-measures ANOVA was performed using Bonferroni's post-hoc test. RESULTS: The muscle activity of the UT was significantly greater in the AC group; than in the control group (p<.05). The muscle activity of the MD was significantly lower in the AC group; than in the control group (p<.05). The greatest level of muscle activity for both the MD and UT was demonstrated at the $0-60^{\circ}$ and $0-90^{\circ}$ of shoulder abduction angles in the AC group. CONCLUSION: These findings showed that low muscle activation of the MD may contribute to hyperactivity of the UT during shoulder abduction in AC patients.

Analysis of Muscle Activity of the Scapular Rotators With Changes of Shoulder Abduction Angle in Both Erect and Slouched Trunk Position (척주 기립자세와 굽힌자세에서 어깨관절 외전각도 변화에 따른 어깨뼈 주위 근 활성도 분석)

  • Kim, Duck-Hwa;Choi, Jong-Duk;Oh, Jae-Seop
    • Physical Therapy Korea
    • /
    • v.11 no.1
    • /
    • pp.45-52
    • /
    • 2004
  • Altered scapular kinematics in the scapular joint is commonly believed to be a factor contributing to trunk posture. The purpose of this study was to analyze the muscle activity with several changes of the shoulder angle. Tests were performed on 10 male subjects by repeated measures. Each subject was measured while sitting in both erect and slouched trunk positions. In each sitting posture, a three-dimensional motion analysis measurement was used to measure thoracic angle and shoulder abduction angle. Measurements were taken with the shoulder abdcution angle at $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$, $120^{\circ}$, and $150^{\circ}$. By using surface Electromyography (EMG) electrodes, we recorded the activity of the upper trapezius, middle trapezius, lower trapezius, middle deltoid, and serratus anterior muscle while the subject held a 4 kg weight at each angle. The mean of root mean square (RMS) of EMG activity was calculated. The middle trapezius, lower trapezius, and middle deltoid muscle activity showed significantly higher results but serratus anterior muscle activity showed significantly lower results (p<.05). With the shoulder angle increased, the muscle activity was also significantly increased (p<.05). In conclusion, the thoracic spine posture significantly affects the scapular muscle during scapular plane abduction, and the slouched posture is associated with increased trapezius muscle activity and with decreased serratus anterior muscle activity.

  • PDF

A Study on the Evaluation of Horizontal, Vertical, Asymmetric and Coupling Multipliers of the NIOSH Lifting Equation in Korean Male (한국인 20대 남성의 NIOSH Lifting Equation 계수평가에 관한 연구)

  • Bae, Dong-Chul;Kim, Yong-Jae
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • The objective of this paper was to evaluate the effectiveness of horizontal, vertical, asymmetric and coupling multipliers for manual material handling. Lifting tasks with 5 different horizontal distances ($30{\sim}70cm$) for 6 vertical distances(ankle, knee, waist, elbow, shoulder and head height) were experimented. The muscle activity and muscle exertion level during asymmetric load handling(without trunk flexion) was experimented. Lifting tasks with and without handle tote box for three postures(straight, bending, right angle posture) were experimented. The degrading tendency did not appeared almost in $60{\sim}70cm$ interval's horizontal distance. As a result of ANOVA, MVC paid attention to horizontal and vertical distance but cross effect was insignificant(p<0.01). The change of the MVC according to the horizontal, vertical distance appeared similar from of RWL. The results of normalized MVC measurement were decreased about 16%, 24%, 34% respectively as the asymmetry angle was $30^{\circ}$, $60^{\circ}$, $90^{\circ}$. RMS EMG values of right erector spinae muscles were decreased as the work posture went to $90^{\circ}$ and those of left erector spinae muscles were increased until the asymmetry angle was $40^{\circ}$ but decreased continually over $40^{\circ}$. 7 subjects, activities of left and right latissimus dorsi muscles were maintained constantly, while for remainer, those were irregular. MVC reduced maximum 23% by type of handle. MVC was highest in straight posture, but was lowest in right angle posture. As a result of ANOVA, MVC paid attention to posture, coupling(p<0.01). To all handle types, biceps brachii activity was increased in right angle posture, but reduced in straight posture. Based on the results of this study, it is suggested that the NIOSH guideline should not be directly applied to Korean without reasonable reexamination. In addition, we need to afterward study through an age classification.

The Effect of ST36, LI4 Acupuncture on Rat Jaw Opening Reflex by Upper and Lower Incisor Pulp Stimulation (족삼리(足三里), 합곡(合谷) 침자(鍼刺)가 상치(上齒), 하치부(下齒部) 동통(疼痛) 억제(抑制)에 미치는 영향(影響))

  • Choi Dong-Hee;Kim Won-Jae;Na Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.18 no.1
    • /
    • pp.95-104
    • /
    • 2001
  • The pain was induced on upper and lower incisor of the rat based on the theory of 'connections of upper incisor pain with stomach meridian and lower incisor pain with large intestine meridian'. Such acupoints as ST36 and LI4 were used for alleviation of upper and lower incisor pain. The digastric myogram (dEMG) was utilized for the pain measurement. The upper incisor pain was gradually decreased during ST36 stimulation and significant differences were observed at 20 and 25 minute point during 60 minutes study. The upper incisor pain was gradually decreased during LI4 acupuncture and 20 minute was the only point that showed a significant difference. The alleviation of lower incisor pain was not obvious during the ST36 acupuncture. The lower incisor pain was gradually decreased during LI4 stimulation with significant differences at 15, 20 and 40 minute point. In conclusion, the upper incisor pain was relieved with ST36 and LI4 acupuncture while LI4 was effective on the lower incisor pain alleviation based on the theory of 'connections of upper incisor pain with stomach meridian and lower incisor pain with large intestine meridian'.

  • PDF

Biometrics System Technology Trends Based on Biosignal (생체신호 기반 바이오인식 시스템 기술 동향)

  • Choi, Gyu-Ho;Moon, Hae-Min;Pan, Sung-Bum
    • Journal of Digital Convergence
    • /
    • v.15 no.1
    • /
    • pp.381-391
    • /
    • 2017
  • Biometric technology is a technology for authenticating a user using the physical or behavioral features of the inherent characteristics of the individual. With the necessity and efficiency of the technology in the fields of finance, security, access control, medical welfare, inspection, and entertainment, the service range has been expanding. Biometrics using biometric information such as fingerprints and faces have been exposed to counterfeit and disguised threats and become a social problem. Recent studies using a bio-signal from the inside of the body other than the bio-information of the external body are being developed. This paper analyzes the recent research and technology of biometric systems using bio-signals, ECG, heart sounds, EEG, and EMG to present the skills needed for the development direction. In the future, utilizing the deep learning to build and analyze database to manage bio-signal based big data for the complex condition of individuals, biometrics technologies suitable for real time environment are expected to be researched.