• Title/Summary/Keyword: EMG measurement

Search Result 175, Processing Time 0.021 seconds

Effect of EMG Biofeedback Training and Taping on Vastus Medialis Oblique for Function Improvement of Patient with Patella Malalignment (내측 사선 광근에 대한 EMG Biofeedback 훈련과 테이핑 적용이 슬개골 부정렬 환자의 기능향상에 미치는 효과)

  • Kim, Dong-Youn;Kim, Su-Hyon;Lim, Young-Eun;Lee, Dong-Geol;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.3
    • /
    • pp.35-43
    • /
    • 2008
  • Purpose: We investigated the effect of isometric resistance exercise on the vastus medialis oblique muscle with inelastic tape and EMG biofeedback training applied to the patello-femoral joints of patients with patella malalignment. Methods: The 39 elderly subjects that had patella malalignment but no neuromuscular disorders were divided into a control group, taping group, and EMG biofeedback training group. Evaluations of function improvement performed before and after the treatment, as well as 4 weeks after treatment. Results: Change in pain in the knee joint were significantly different among groups (p<0.05). Maximum voluntary isometric contractility in the quadriceps muscle was significantly in the EMG biofeedback group (p<0.001). The WOMAC (Western Ontairo & McMaster Questionnaire) index showed a significant change (p<0.05) in pain, function, and total score. Taping and EMG biofeedback training showed a lasting effect until measurement 4 weeks after treatment. SF-36 (Medical outcome short form-36), which assesses the quality of life, did not significantly change. Conclusion: In osteoarthritis patients with a loss of patello-femoral joint function, isometric resistance exercise of the vastus medialis oblique muscle with taping seems effective.

  • PDF

A Study on the Development of the EMf System Using Personal Computer (개인용 컴퓨터를 이용한 근전도(EMG) 시스템 개발에 관한 연구)

  • 조승진;김민수
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.243-248
    • /
    • 1990
  • EMG (eleltromyographic) signals are generated by contracting muscle and detected in and out side of muscle in the form of random signals. In the measurement of muscle fatigue, the mean frequency of EMG signals using spectrum analysis is an important parameter in diagonosis of muscle disease and in sports medicine fields. In this study, the degree of spectral transfer to lower frequency caused by accumulation of Latic acid inside the muscle is estimated. The new spectral analysis method using 2"d order hAaximum Entropy Method was applied to estimate the mean frequency and we confirmed that this new method yields fast and reliable estimation.tion.

  • PDF

A Measurement Method of Muscle Fiber Conduction Velocity for Surgace EMG Signal of Muscle Diseased Patient (근 질환자의 표면 근전도 신호에 대한 근섬유 전도속도 측정방법)

  • Lee, J.;Kim, S. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.171-178
    • /
    • 2001
  • 본 연구에서는 강건 시지연추정 알고리즘을 바탕으로 하여 표면근전도 신호로부터 새로운 근섬유 전도속도 측정방법을 제안하였다. 제시한 방법은 가우시안 가정 하에서 유도된 기존의 방법들로는 불가능한 비가우시안 충격성잡음을 포함하는 표면근전도 신호를 대상으로도 정확하게 근섬유 전도속도를 측정할 수 있다. 제시한 방법의 평가를 위하여 먼저, 마미총 증후군에 걸린 근질환자의 근전도 신호가 비가우시안 $\alpha$-stable 확률분포로 모델링할 수 있음을 보였으며, 정상인과 근질환자 6명의 피검자로부터 족저단신근과 내측광근에서 각각 근전도 신호를 수집하여 실험한 근섬유 전도속도 측정결과를 타 연구자들과 비교, 평가하였다. 실험결과, 족저단신근의 경우 근섬유 전도속도가 평균 4.60$\pm$0.50m/s로 내측광근의 경우 5.66$\pm$0.59m/s로 각각 구할 수 있었다.

  • PDF

EMG signal identification using LPC cepstrum coefficients (LPC cepstrum 계수를 이용한 근전도 신호의 동작판별)

  • Chung, T.Y.;Park, S.H.;Kim, H.R.;Wang, M.S.;Choi, Y.H.;Byun, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.738-741
    • /
    • 1988
  • In this paper, we deal with the movements identification of EMG signals by LPC cepstrum coefficients. Movements were identified by extration of characteristics of similar patterns in Euclid distance measurement method for EMG signals generated by voluntary contractions of subject's musculature. As number of coefficients is larger, we obtain the better rate of movements identification. By exact extraction of signals and decision of optimal coefficient, it is expected that these results will apply to prosthesis control in real-time.

  • PDF

Development of a Fatigue Index Based on the Measurement of Localized Muscular Fatigue During the Cyclic Isometric Contraction (주기적 등척성 수축에서의 국소근육피로 측정을 통한 피로지수의 개발)

  • Jung, So-Ra;Chung, Min-Keun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.19 no.4
    • /
    • pp.87-96
    • /
    • 1993
  • Spectrum analysis of surface electromyogram (FMG) signals is an effective approach to the study of localized muscular fatigue during isometric contraction. Many investigators have con firmed the frequency of the EMG signals being lowered during sustained contaction. In this study, the cyclic loading tasks were performed, and a comparison was made for the median power frequency shift pattern of the EMG signals with the sustained contraction of the same load. The median power frequency shift of the EMG signals for the cyclic loading task was found to be a part of that for the sustained contraction. Based on this result, a new muscle fatigue index was computed by normalizing the duration of the sustained contraction. A fatigue index was obtained as a function of exertion level and the work/rest schedule. With the proposed fatigue index, it is possible to evaluate or predict the degree of muscular fatigue for a physically demanding task.

  • PDF

Measurement of the pain responses induced by electric pulp test (전기 치수 자극에 의해 유발된 동통 반응의 측정)

  • Ahn, Seon-Hui;Nam, Ki-Chang;Kim, Soo-Chan;Kim, Jae-Sung;Lee, Seung-Jong;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.727-730
    • /
    • 2003
  • Electric pulp test is a method to examine the vitality of dental pulp using the electrical stimulation. During the pulp test, the current stimulates intradental nerve, and makes patients painful. Some studies were accomplished to measure the responses of subjects by stimulating over the sensory threshold. In this study, we examined the time delay between pain feeling and stimulation stop in clinical situation. And we measured the activated responses(EMG in anterior belly of digastric muscle, voice, and finger span). As a result, it was verified that the minimum and maximum delay was EMG and voice, respectively. By reducing the excessive stimulus time, the unnecessary pain can be minimized using EMG that has the minimum delay.

  • PDF

The Study on effect of the Muscle Activities for Dietshoes (Backless) (다이어트신발(Barkless)이 근육 활성도에 미치는 영향에 관한 연구)

  • Lee, Chang-Min;Oh, Yeon-Ju;Lee, Kyung-Deuk;Park, Seung-Bum;Lee, Hoon-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.117-124
    • /
    • 2006
  • The modern convenient life formed by industrial development becomes lack of exercise and takes an interest in diet. Specially, professional walking shoes is developed as people take an interest in jogging, Those shoes, professional walking shoes or Dietshoes, increase exercise effects by change of heel types. Therefore, this study investigated motility effects by EMG experiment in order to measure Muscle Activities (MA) while wearing diet shoes (backless). Experiment was conducted by EMG measurement, from calf (gastrocnemius muscle), thigh (vastus muscle) and waist (erector spinae muscle), of 12 high school students. Exercise effects between the two shoes were analyzed by EMG (MF; Median Frequency, MPF; Mean Power Frequency, ZCR; Zero Crossing Rate). Results showed that the Dietshoes(MF: 48.21Hz, MPF: 65.0Hz, ZCR: 100.6Hz) had larger EMG value than that of Normal shoes(MF: 40.47Hz, MPF: 58.04Hz, ZCR: 82.09Hz). Also, in MA, the highest activities are showed in the calf, the second one is in waist, and last one is in thigh during gate. ANOVA between shoes in measurement parts showed significant effects in MF (gastrocnemius: p-value=.022, vastus laterals: p-value=.037, erector spinae: p-value=.082), MPF (gastrocnemius: p-value=.032, vastus laterals: p-value=.046, erector spinae: p-value=.090), and ZCR (gastrocnemius: p-value=.000, vastus laterals: p-value=.004, erector spinae: p-value=.134). And MA of Dietshoes is higher than that of Normal shoes, and decreasing rate of MA in Dietshoes is less than that of Normal shoes. Thus, this study validates exercise effects of Dietshoes.

Fatigue Analysis of Knee Extensor Using sEMG and Dynamometer (sEMG와 Dynamometer를 이용한 슬관절 신전근의 피로 분석)

  • Jeong, Jin-Gyu;Kim, Yong-Nam;Park, Jang-Sung;Kim, Tae-Youl
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.3 no.1
    • /
    • pp.31-47
    • /
    • 2005
  • Fatigue is a common experience in our daily life and in therapeutic exercises. Human muscle fatigue has been studied using a wide variety of exercise models, protocols and assessment methods. This study conducts quantitative evaluation of fatigue of knee extensor with surface electromyography and dynamometer and is to provide basic materials in physical therapy diagnosis and assessment of skeletal muscle. Measurement of two stages was conducted with 88 normal adults between their twenties and seventies, correlations and differences using collected data according to age was compared and correlations among measured items were analyzed and then the following conclusions were obtained. Analysis of sEMG and dynamometry of knee extensor showed that MDF, FI, MVIC, ET had the closest relations with age and MDF, FI, MVIC were significantly increase with aging. In addition, it was found that there were high correlation among items of analysis.

  • PDF

MEASUREMENT OF THE EXCESSIVE STIMULUS TIME AFTER THE SENSORY THRESHOLD LEVEL DURING ELECTRIC PULP TESTING (전기 치수 검사 시 역치 자극 이후 과용(過用) 자극 시간의 측정)

  • Nam, Ki-Chang;Ahn, Seon-Hui;Kim, Soo-Chan;Kim, Deok-Won;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.226-232
    • /
    • 2004
  • Use of electric pulp testing elicits painful response in vital teeth. In this study, we examined the excessive time from pain feeling to stimulation disconnection in clinical situation. D626D (Parkell Inc., USA.) scan type electric pulp tester was used in total of 23 young healthy individuals. Each of the right central incisors and first premolars were used as testing teeth. Stimulation disconnection was achieved by EMG in anterior belly of digastric muscle, finger span, and voice and the excessive stimulation time over the sensory thresh-old was recorded. As a result, we found that the short responses before the stimulation disconnection appeared following order:EMG, finger span, and voice. The EMG disconnection is suggested to be used to reduce the excessive stimulus time in electric pulp testing.

Evaluation of Muscle Activity according to Exercise Intensity during the Deadlift and Upright Row (데드리프트와 업라이트로우 시 운동강도에 따른 근활성도 평가)

  • Cho, Won Jun;Song, Ju Won;Choi, Myung Soo;Kim, Nam Yim;Kim, Ryong;Lee, Chang Min;Hong, Jae Heon;Kang, Gun Woo;Moon, Young Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.4
    • /
    • pp.270-275
    • /
    • 2021
  • Objective: The purpose of this study was to evaluate 16 muscles activity according to three exercise intensity when performing Deadlift and Upright row. Method: To accomplish the purpose of the study, subjects (n=10) were performed Electromyography (EMG) measurement for 16 different muscles. The experimental movements were Deadlift and Upright row, measured five times for each intensity (40%, 60%, 80%) of 1RM. This study normalized the EMG values through RVC for comparative analysis. Results: The results were summarized as follows: As a result of Deadlift, there was significant difference in the mean EMG value according to the exercise intensity in all muscles except RA, PM and BB (p<.05). As a result of Upright row, There was significant difference in the mean EMG value according to the exercise intensity in all muscles except BF, TA, GN, RA and UT (p<.05). Conclusion: This study allowed us to know the activities of major muscles according to the exercise intensity for 16 different muscles when performing Deadlift and Upright row.