• Title/Summary/Keyword: EMF Exposure

Search Result 72, Processing Time 0.022 seconds

ITU-T Standardization for EMC and Environment of Telecommunication Network (전기통신설비의 EMC 및 환경에 관한 ITU-T 표준 동향)

  • Oh, Ho-Seok
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.239-241
    • /
    • 2009
  • This paper gives the activities and trend analysis handled in the ITU-T study group 5 meeting. In the meeting, the title of SG(Study Group)5 was changed into 'Environment and climate change' since the role of the former Focus Group 'ICT and Climate Change' was moved to SG5. SG5 consists of 3 WP(Working Part) and have total 20 Questions. The Recommendations to be established or revised were discussed and new Recommendations, K.79 and K.80, were consented. The agenda for the human exposure to electromagnetic fields due to radio systems and mobile equipment was focused and discussed in detail. Also, related to ICT and climate change, new questions to be studied in this study period were discussed and defined.

  • PDF

Measurement and Analysis of the Magnetic Fields Magnitude under High Voltage Transmission Lines (초고압 송전선로의 자계크기 실측과 해석)

  • Cho, Sung-Bae;Lee, Eun-Woong;Lee, Min-Myung
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1583-1585
    • /
    • 1998
  • EMF measurements for the selected lines by a kinds of tower configurations conductors among 154kV, 345kV transmission lines which are a standard forms of high voltage transmission line in Domestic are performed at the field. Based on these measurings, Co-relation of both the Power current and the magnetic field strength is studed. compared of measured and calculated magnetic magnitude. and Using the measured equation obtained from field measuring, Magnetic field exposure value occurring under T/L for one year(1997) is presented.

  • PDF

A New Method to Estimate the Induced Electric Field in the Human Child Exposed to a 100 kHz-10 MHz Magnetic Field Using Body Size Parameters

  • Park, Young-Min;Song, Hye-Jin;Byun, Jin-Kyu
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.174-180
    • /
    • 2014
  • In this paper, a new and simple method is proposed to quickly estimate the induced electric field in the human child exposed to a 100 kHz-10 MHz magnetic field, for the sake of electromagnetic field (EMF) safety assessment. The quasi-static finite-difference time-domain (FDTD) method is used to calculate the induced electric fields in high resolution 3D human child models with various body size parameters, in order to derive the correction factor for the estimation equation. The calculations are repeated for various frequencies and incident angles of the magnetic field. Based on these calculation results, a new and simple estimation equation for the 99th percentile value of the body electric field is derived that depends on the body size parameters, and the incident magnetic field. The estimation errors were equal to or less than 5.1%, for all cases considered.

Analysis of Human Exposure to Wideband Pulse EMF Dependent on the Dispersion Algorithm (분산 알고리즘에 따른 광대역 펄스 전자파 노출에 대한 인체 노출량 해석)

  • Ka Won-Suk;Kim Tae-Hong;Kim Jeong-Ran;Pack Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.7 s.110
    • /
    • pp.684-693
    • /
    • 2006
  • In this paper, the SA (Specific Absorption) distribution in a human head, exposed to wideband pulse EMF, has been analyzed by taking into account the dispersion characteristics of biological tissues. The dispersive properties of biological tissues are characterized by the 4th Cole-Cole model. Currently, there is no dispersive FDTD algorithm to implement the 4th Cole-Cole model accurately. Thus, in this paper the FDTD methods with the dispersive algorithm for the 1st-order Cole-Cole model and the 3rd-order Debye model were used for SA analysis. The validity of each model has been investigated first, and then the effects of dispersion on SA distribution have been studied.

Investigation of the Variation of SAR Values in Mice and Rats Depending on the Exposure Conditions in Whole-Body Exposure Environments (전신 노출 환경에서 노출 조건에 따른 마우스와 랫트의 SAR 값 변화량 분석)

  • Mun, Ji-Yeon;Seo, Min-Gyeong;Kim, Tae-Hong;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.161-167
    • /
    • 2013
  • In animal experiments for EMF exposure, it is very important to estimate the SAR values accurately in animals. In this paper, we investigated the variation of SAR values in mice and rats, depending on the number and separation distance of animals and the existence of the water-supplying bottle. The whole-body of mice or rats in a cage were exposed in the reverberation chamber at CDMA and WCDMA frequencies. Simulation results show that the variation of the whole-body averaged SAR is larger when several animals are exposed in a cage, compared to the existence of water-supplying bottle and the amount of water. It turns out that compared to single mouse or rat is located in the cage, the maximum variation of the whole-body averaged SAR values for mice at 850 MHz and 1,950 MHz are 15.3 % and 14.9 % when three mice are located in the cage, and those for rats are 18.7 % and 21.1 % for each frequency when two rats are located in the cage. It is concluded that the variation of SAR values depending on the exposure conditions in real situation cannot be ignored.

Dosimetric Analysis for Human Exposure to Body-Mounted Wireless Devices (인체 착용형 휴대 단말기에 대한 노출량 해석 연구)

  • Park Min-Young;Ko Chae-Ok;Kim Jeong-Ran;Pack Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.2 s.105
    • /
    • pp.207-212
    • /
    • 2006
  • A variety of wireless devices are commercially available now. Most of studies, however, have been directed to the biological effects of mobile-phone EMF. In this paper, dosimetric analysis for wireless devices of head-mounted display type and a wristwatch type were made to investigate possible biological effects of these devices. SAR(Specific Absorption Rate) distributions were calculated using FDTD(Finite Difference Time Domain) method, for adult human models such as standard Korean human model and VHP(Visible Human Project) model, as well as scaled child models. Measurements were also performed for SAM phantom wearing a simplified prototype for a wireless device for validation of the simulation results. It has been found that children are more vulnerable to such exposure, and these devices could cause some biological effects even for relatively lower power compared to conventional mobile pones.

Evaluation of Chromosomal Alteration in Electrical Workers Occupationally Exposed to Low Frequency of Electro Magnetic Field (EMFs) in Coimbatore Population, India

  • Balamuralikrishnan, Balasubramanian;Balachandar, Vellingiri;Kumar, Shanmugam Suresh;Stalin, Nattan;Varsha, Prakash;Devi, Subramaniam Mohana;Arun, Meyyazhagan;Manikantan, Pappuswamy;Venkatesan, Chinnakulandhai;Sasikala, Keshavarao;Dharwadkar, Shahnaz N.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2961-2966
    • /
    • 2012
  • Extremely low frequency electro magnetic fields (EMFs) have been classified as possibly carcinogenic to humans by the International Agency for Research on Cancer. An increased number of chromosomal alterations in peripheral lymphocytes are correlated with elevated incidence of cancer. The aim of the present study was to assess occupationally induced chromosomal damage in EMF workers exposed to low levels of radiation. We used conventional metaphase chromosome aberration (CA) analysis and the micronucleus (MN) assay as biological indicators of non ionizing radiation exposure. In the present study totally 70 subjects were selected including 50 exposed and 20 controls. Informed written consent was obtained from all participants and the study was performed in accordance with the Declaration of Helsinki and the approval of the local ethical committee. A higher degree of CA and MN was observed in exposed subjects compared to controls, the frequency of CA being significantly enhanced with long years of exposure (P<0.05). Moreover increase in CA and MN with age was noted in both exposed subjects and controls, but was significantly greater in the former. The results of this study demonstrated that a significant induction of cytogenetic damage in peripheral lymphocytes of workers occupationally exposed to EMFs in electric transformer and distribution stations. In conclusion, our findings suggest that EMFs possess genotoxic capability, as measured by CA and MN assays; CA analysis appeared more sensitive than other cytogenetic end-points. It can be concluded that chronic occupational exposure to EMFs may lead to an increased risk of genetic damage among electrical workers.

Fabrication of Multiple-Frequency Exposure System for In Vitro Experiment (세포 실험용 다중 주파수 동시 노출 장치 제작)

  • Kim, Tae-Hong;Seo, Min-Gyeong;Mun, Ji-Yeon;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.213-219
    • /
    • 2012
  • Recently, we are simultaneously exposed by various electromagnetic sources due to an increase of mobile communication services. However, EMF(Electric, Magnetic and Electromagnetic Field) study has been performed mainly about only single frequency. The objective of this paper is to develop an multiple-frequency exposure system for in vitro experiment. The exposure unit for in vitro experiments was designed by radial transmission line type to get broadband characteristics to generate signals of CDMA at 836.5 MHz and WCDMA at 1950 MHz frequency simultaneously. The modulated signals were delivered to the conical antenna through amplifier, digital attenuator and RF combiner. SAR values were obtained by the averaged values of 3 measured values at 9 points in petri dish using the fiber optic temperature probe. The measured return loss was under -15 dB. For 1 W input power, the mean value and standard deviation of SAR were $0.105{\pm}0.019$ for the CDMA frequency and $0.262{\pm}0.055$ for the WCDMA frequency.

Mobi-kids: A Case-control Study Protocol on Electromagnetic Field Radiation Exposure from Telecommunication and Brain Tumors in Children and Adolescents (모비키즈: 통신전자파 노출과 어린이청소년의 뇌종양에 관한 환자 -대조군 연구 프로토콜)

  • Choi, Kyung-Hwa;Kim, Dong-Seok;Lee, Jung-il;Ra, Young-Shin;Phi, Ji Hoon;Ahn, Young Hwan;Kwon, Jong Hwa;Lee, Ae-Kyoung;Choi, Hyung-Do;Ha, Mina
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.3
    • /
    • pp.182-190
    • /
    • 2015
  • Objectives: To introduce a protocol of Mobi-kids study which was aimed to examine an association between radiofrequency (RF) radiation exposure by mobile phone use and brain tumor risk in children and adolescents. Methods: The Mobi-kids study was a multinational matched case control study using a standardized protocol with the number of subjects targeted about 1,000 cases and 2,000 controls aged 10 to 24. In Mobi-Kids Korea, the source population was restricted to Seoul, Incheon, and Gyeonggi-do province. Eligible cases of primary brain tumor (glioma, meningioma, and others) were diagnosed from January 2012 to June 2015. Eligible controls were appendicitis patients operated during the study period. Two controls were matched on age, gender, and study region for 1 case. Information about pattern and history of mobile phone use and other covariates were obtained by face to face interview by trained interviewer. The Mobi-kids study has been involved in Mobi-expo as a validation study about mobile phone use, XGridmaster to localize tumor in the brain for RF energy calculation, and histological review for validation of diagnosis. Results: The Mobi-kids was the first and largest study in children and adolescents to estimate risk of brain tumor in association with the RF energy absorption in the brain estimated by mobile phone use. Forty-six-cases and 54 controls were collected as of September 2014 in Korea. Conclusions: The meaningful results of the study were expected because of the largest sample size, high validity of EMF exposure assessment as well as the susceptible study populationof children and adolescents.

Realization of High Impedance Surface Characteristics Using a Periodically Transformed Artificial Magnetic Conductor Structure and Reduction Technique of Specific Absorption Rate

  • Lee, Seungwoo;Rhee, Seung-Yeop;Kim, Pan-Yeol;Kim, Nam
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.2
    • /
    • pp.113-119
    • /
    • 2013
  • We developed a transformed, symmetrical, mushroom-like surface without via holes in cells focused on a 2.4-GHz WLAN band. Each slot in the novel type structure plays a key role in modeling at the desired frequencies. The designed artificial magnetic conductor (AMC) has several advantages, including a small size, a wider bandwidth, a short reflecting distance to the antenna, and easy fabrication because there are no via holes. Overall dimensions of the AMC cell are 21 mm $(Width){\times}21mm$ $(Height){\times}2.6mm$ (Thickness), and the bandwidth is about three times wider (11.7%) compared to that of a conventional AMC (4.0%). For evaluating the performance of the proposed structure, a reflector, which periodically consists of the designed AMC cells, was developed. The antenna with the investigated AMC reflector not only works within a quarter of the wavelength because of the extremely high wave impedance generated by the AMC cells on the surface of the structure but also reduces the specific absorption rate (SAR). Electromagnetic field (EMF) exposure to a human phantom was analyzed by applying the designed reflector to the 2.4-GHz dipole antenna in a tablet PC. The calculated peak SAR averaged over 1 g was 0.125 W/kg when the input power was 1 W and the antenna was located at 20 cm from the human phantom. However, the SAR value was only 0.002 W/kg (i.e., 98.4% blocked) when the designed reflector was inserted in front of the antenna.