• Title/Summary/Keyword: EMC test

Search Result 130, Processing Time 0.03 seconds

The Study on the Cycling Time for Interbus (인터버스 순환시간 측정에 대한 연구)

  • Park, Jang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.170-175
    • /
    • 2004
  • The test on the cycle time of the Interbus, widely used in automobile industry, is evaluated in this paper. The measurement of cycle time is a very Important factor for performance of Interbus. The test was performed by the under normal circumstances and circumstances with EMC. The theoretical cycle time which was derived from mathematical form and from real system with Interbus approach to nearly result. As a result, it is shown that Interbus is deterministic, rapid and reliable system.

The Development and Evaluation of an e-Learning Program for Novice Nurses before Beginning to Work in a Hospital Using KMS(Knowledge Management System) (지식경영 시스템을 활용한 신규간호사 e-Learning 프로그램 개발 및 평가)

  • Song, Young-Shin
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.13 no.1
    • /
    • pp.82-89
    • /
    • 2007
  • Purpose: The purpose of this study was to develop and evaluate an e-Learning Program designed to enhance novice nurses's performance ability Method: The e-Learning program was designed for novice nurses before beginning to work in a hospital using a KMS(Knowledge Management System). This study was carried out from February 2006 to April 2007. The program had progressive steps including design, pilot test & modification, contents development, program application and evaluation. After the program design and pilot testing, the learner's satisfaction was analyzed. Result: The program site is http://kms.emc.ac.kr titled, 'Cyber Education Center'. The sixteen part course has been developed as follows: blood sugar test, skin test, insulin test 1, insulin test 2, blood culture, blood sampling, heat therapy, cold therapy, glycerin enema, preparation of operation, oxygen therapy, suction technique, transfusion, foley catheterization and aseptic technique. The overall learner's satisfaction score was 4.08 out of 5 points. Conclusion: E-Learning could be useful for education and nursing work. This method may be effective for clinical nurses.

  • PDF

A Study of Failure Mechanism through abnormal AlXOY Layer after pressure Cooker Test for DRAM device (DRAM 소자의 PCT 신뢰성 측정 후 비정상 AlXOY 층 형성에 의해 발생된 불량 연구)

  • Choi, Deuk-Sung;Jeong, Seung-Hyun;Choi, Chae-Hyoung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.3
    • /
    • pp.31-36
    • /
    • 2018
  • This research scrutinizes the reason of failure after pressure cooker test (PCT) for DRAM device. We use the physical inspecting tools, such as microscope, SEM and TEM, and finally find the discolor phenomenon, corrosion of Al and delamination of inter-metal dielectric (IMD) in the failed devices after PCT. Furthermore, we discover the abnormal $Al_XO_Y$ layer on Al through the careful additional measurements. To find the reason, we evaluate the effect of package ball size and pinhole in passivation layer. Unfortunately, those aren't related to the problems. We also estimate halide effect of Al. The halogens such like Cl are contained within EMC material. Those result in the slight improving of PCT characteristics but do not perfectly solve the problems. We make a hypothesis of Galvanic corrosion. We can find the residue of Ti at the edge of pad open area. We can see the improving the PCT characteristics by the time split of repair etch. The possible mechanism of the PCT failure can be deduced as such following sequence of reactions. The remained Ti reacts on the pad Al by Galvanic corrosion. The ionized Al is easily react with the $H_2O$ supplied under PCT environment, and finally transfers to the abnormal $Al_XO_Y$ layer.

Analysis of Impulse Withstand Voltage Performance of Lighting Equipment (조명기기의 임펄스내전압 성능의 분석)

  • Lee, Bok-Hee;Pang, Pyung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.91-96
    • /
    • 2014
  • Modern electronic circuits are becoming more vulnerable to damage by surges, and it is required to improve the impulse withstand voltage performance of electrical and electronic equipment. This paper presents the impulse withstand voltage performance of lighting equipment connected to power lines, and the impulse withstand voltage tests for fluorescent lamp, LED lamp and halogen lamp were carried out according to the reference standards under normal service conditions. To conduct performance tests against lightning surge, a combination wave ($1.2/50{\mu}s$ voltage - $8/20{\mu}s$ current) was employed. The test surge was applied between lines or between line and ground of the specimen to be measured. The test surge was applied synchronized at the peak value of the positive and negative AC voltage waves. As a consequence, some specimens satisfied the impulse withstand voltage test criteria, but lighting equipment such as 36W fluorescent lamps, 5W and 5.5W LED lamps and 50W halogen lamp were damaged at the test voltage levels between power lines. It is needed to improve the qualities of lighting equipment to satisfy EMC immunity requirements of equipment for general lighting purposes.

A Study About the Application Feasibility of EMS IEC 61000-4-6 Test Standard on Electronic Power Meter (전자식 계기 IEC 61000-4-6 EMS 시험표준 적용 타당성 연구)

  • Kim, Seok-Gon;Park, Chang-Ho;Shin, Dong-Yeol;Song, Tae-Seung;Choi, Yong-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1261-1267
    • /
    • 2011
  • Electricity meters using in Korea are about 1.8 million units. From among these, electronic meters for high voltage, about 170 thousand units were installed to the digital type meter and ones for low voltage installed hundreds of thou-sands of meters through a model project. Recently, low voltage meter are expected to complete the installation within several years. Domestic power metering technology is being beyond a simple framework with an electronic type and is rapidly evolving to intelligent smart metering systems in conjunction with promotion of a national smart grid project. Accordingly, it is important to ensure an immunity of meter for electromagnetic field and environmental noise at the installation site. In this paper, we are going to check the validity of international standard that focusing on RF electromagnetic field immunity of meter to secure the quality and improve the reliability in field operation of meter. And we will verify the validity of test specification focused on actual installation environment and are going to offer the improvement plan of test standard.

Method of Measurement of Electromagnetic Emission from Trains (철도 차량의 전자파 방사 측정 방법)

  • Chae, Eun-Kyung;Ryu, Joon-Hyoung;Baik, Kwang-Sun;Yoon, Yong-Ki
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2037-2042
    • /
    • 2011
  • The railway electromagnetic environment is much more severe than most commercial and domestic environments. There are concerns about electromagnetic emissions from railways and their potential to interfere with the operation of commercial radio service and other equipment. EMC standards for railway applications are referenced as EN 50121 series and these standards describe the measurement method and specify limits for emission. However standard provide precise description of the general aspect of the measurement procedure and requirement of test equipments, making a reliable measurement of the radiated emissions from a train is a problem of balance between available observation time and the measurement time required by the characteristics of the measurement system. This paper focuses on the problem of measurement.

  • PDF

Effect of the Addition of Antimicrobial Materials Before and After Aging on the Physicochemical Properties of Low-Salt Kochujang during Storage

  • Seo, Young-Eun;Bae, Hwa-Sook;Kim, Dong-Han
    • Journal of Applied Biological Chemistry
    • /
    • v.57 no.4
    • /
    • pp.287-294
    • /
    • 2014
  • To improve the shelf life of low-salt Kochujang, Korean hot pepper paste, antimicrobial materials were added at different times before and after aging. The kochujang was then packaged and stored at $30^{\circ}C$ for 15 weeks, and changes in microbiological and physiochemical properties were evaluated. Hunter a- and b-values decreased considerably during storage. The total color difference (${\delta}E$) was greater in the ethanol-chitosan (EC) treatment than in the control and after pasteurization (A-P) treatment. Gas was produced until the seventh week of storage. The control and the A-P treatments produced more gas than the other treatments, and these had the largest number of yeasts and aerobic bacteria. The pH of the EC treatment was higher than that of the other treatments, and the A-P treatment had the highest level of titratable acidity. During storage, the oxidation-reduction potential was lower in the EC and ethanol-mustard-chitosan (EMC) treatments. The reducing sugar content decreased remarkably in the control and A-P treatments, with high production of ethanol. There was a significant change in the content of amino-type nitrogen in the control and A-P treatments, and the content of ammonia-type nitrogen was lowest in the EMC treatment. In the sensory test of kochujang, the ethanol-mustard (EM) and ethanol (E) treatments were significantly higher than the EC, control, and A-P treatments (p <0.05). EM or E alone was effective in extending the shelf life of kochujang when added before aging.

A Study on the Performance Verification Method of an ALSE(Absorber-Lined Shielded Enclosure) by the CISPR25 (CISPR25의 ALSE(Absorber-Lined Shielded Enclosure) 성능 검증 방법에 관한 연구)

  • Shin, Jaekon;Jung, Kibum;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.791-797
    • /
    • 2013
  • This paper proposes a new way to verify the performance of an absorber lined shielded enclosure(ALSE) in accordance with CISPR25, EMC standards dedicated to testing automotive components. CISPR16 requires the use of NSA and VSWR methods to test the performance of a chamber. As for CISPR25, however, there hasn't been standardized ways to verify the performance of ALSE. This paper purports to present an improved method for the verification based on a long-wire antenna method under discussion at CISPR25 JFT. Existing discussions on a long-wire antenna method proposes that an antenna should reach 500 millimeters in length, while this paper adopts the antenna length of 1,700 millimeters. This paper also assesses the effects of matching conditions and studies problems related to methods which have been already proposed and key parameters in order to improve verification methods.

Electrochemical Characteristics of Porous Silicon/Carbon Composite Anode Using Spherical Nano Silica (구형 나노 실리카를 사용한 다공성 실리콘/탄소 음극소재의 전기화학적 특성)

  • Lee, Ho Yong;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.459-464
    • /
    • 2016
  • In this study, the electrochemical characteristics of porous silicon/carbon composite anode were investigated to improve the cycle stability and rate performance in lithium ion batteries. In this study, the effect of TEOS and $NH_3$ concentration, mixing speed and temperature on particle size of nano silica was investigated using $St{\ddot{o}}ber$ method. Nano porous Si/C composites were prepared by the fabrication processes including the synthesis of nano $SiO_2$, magnesiothermic reduction of nano $SiO_2$ to obtain nano porous Si by HCl etching, and carbonization of phenolic resin. Also the electrochemical performances of nano porous Si/C composites as the anode were performed by constant current charge/discharge test, cyclic voltammetry and impedance tests in the electrolyte of $LiPF_6$ dissolved inorganic solvents (EC:DMC:EMC=1:1:1vol%). It is found that the coin cell using nano porous Si/C composite has the capacity of 2,006 mAh/g and the capacity retention ratio was 55.4% after 40 cycle.

The Characteristics Analysis of The PCB Pattern for The Mobile panel Power Supply on The PMIC (모바일 패널 전원 공급을 위한 PMIC의 PCB 패턴의 특성 분석)

  • Chung, Sung-In;Kim, Seo-Hyeong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.6
    • /
    • pp.39-44
    • /
    • 2011
  • This purpose of this study is to propose the characteristics analysis of the PCB pattern designed two modes for the output voltage value on the PMIC through converting the limited voltage value inputted from a battery. The PCB design technology has been undergoing difficulty in getting the related technology in a domestic market because of increasing EMI/EMC, Cross-talk, Impedance. And it requires to have the appropriate clearance between the patterns and the technology of PCB pattern width with a amperage according to various uses. The study carried out the characteristics analysis of the PCB pattern designed from a direct output method without a capacitor[mode1], to an output method through a capacitor[mode2] for PMIC output voltage value. Besides, we calculated the pattern width with a amperage using the equation suggested by IPC-2221, presenting the right way of the layout design to analyze the trouble with the test. Therefore, this study is expected to contribute not only to applying the PMIC design for the mobile panel power supply, but also helping the design and application technology in various areas such as car control, camera, note-book, computer, PDA, etc.