Adhesion Strength Measurements of Cu-based Leadframe/EMC Interface

  • Lee, Ho-Young;Jin Yu
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.2
    • /
    • pp.1-12
    • /
    • 1999
  • Brown oxide and/or black oxide layers were formed on the surface of Cu-based leadframe by chemical oxidation of leadframe in hot alkaline solutions, and their growth characteristics were studied. Then, to measure the adhesion strength between leadframe and epoxy molding compound (EMC), oxidized leadframe samples were molded with EMC and machined to form sandwiched double-cantilever beam (SDCB) specimens and pull-out specimens, respectively. Results showed that the adhesion strength of un-oxidized leadframe/EMC interface was inherently very poor but could be increased drastically with the nucleation of acicular CuO precipitates on the surface of leadframe. The presence of smooth faceted $Cu_2O $ on the surfaces of leadframe gave close to zero interfacial fracture toughness (Gc) and reasonable pull strength (PS). A direct correlation between Gc and PS showed that PS can be a measure of Gc only in a limited range.

  • PDF

Comparison and Calculation Method on the Separation Between ICT and Power Cabling Considering EMC (EMC를 고려한 ICT배선과 전력배선 이격거리 기준의 비교검토 및 산정방식)

  • Yeom, Jin-Geun;Jeong, Seung-Hyun;Byeon, Cheol-Gyun;Lee, Ju-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.91-96
    • /
    • 2014
  • The requirements for separation between ICT cables and power cables depend upon the electromagnetic immunity of the ICT cable, the construction of the power cable, the quantity of, and type of electrical circuits and the presence of dividers etc. We studied and reviewed the regulations and standards relevant for requirements of this separation in domestic and foreign. And then we would like to suggest the method of separation calculation between ICT and power cabling taking the EMC into consideration.

Irregular Failures at Metal/polymer Interfaces

  • Lee, Ho-Young
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.4
    • /
    • pp.347-355
    • /
    • 2003
  • Roughening of metal surfaces frequently enhances the adhesion strength of metals to polymers by mechanical interlocking. When a failure occurs at a roughened metal/polymer interface, the failure prone to be cohesive. In a previous work, an adhesion study on a roughened metal (oxidized copper-based leadframe)/polymer (Epoxy Molding Compound, EMC) interface was carried out, and the correlation between adhesion strength and failure path was investigated. In the present work, an attempt to interpret the failure path was made under the assumption that microvoids are formed in the EMC as well as near the roots of the CuO needles during compression-molding process. A simple adhesion model developed from the theory of fiber reinforcement of composite materials was introduced to explain the adhesion behavior of the oxidized copper-based leadframe/EMC interface and failure path. It is believed that this adhesion model can be used to explain the adhesion behavior of other similarly roughened metal/polymer interfaces.

A Study on Electromagnetic Environment of Marine Ship (해상 선박의 전자파환경에 대한 연구)

  • Kim Dong-Seek;Park Young-Hwan;Cho Hyung-Rae;Min Kyeong-Sik
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.3 no.2 s.5
    • /
    • pp.119-128
    • /
    • 2004
  • Recently, the accidents on the sea have arisen due to the increase of the nautical traffic and the digitization of equipments for marine. Therefore, IMO(International Maritime Organization) have provided the recommendation of EMI and EMS for radio communication and equipments of marine from SOLAS convention at July 1st 2002. In this paper, we measured EMC environment on the Hanbada, which is Korea Maritime University training ship, for basic EMC environment of ship. The measuring point was Bridge and Engine Control Room of the ship, we measured at the test point that was set at random. Measured Band is from 30 MHz to 2 GHz, polarization measurement is processed both vertical and horizontal polarization. We analysed the results in consideration of permissible criteria.

  • PDF

An investigation Study of Electromagnetic Compatibility for Power Module (전원모듈의 전자파 적합성(EMC) 특성 분석)

  • Chae, Gyoo-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.6
    • /
    • pp.23-28
    • /
    • 2016
  • In this study, an investigation study on EMC(Electromagnetic Compatibility) is presented for power converter circuit. A DC-DC power converter circuit using LT3652 chip is designed and fabricated. The simulation results using ANSYS SIwave for far field radiation and unwanted emissions are presented. To minimize the unwanted emissions, we design a optimized circuit by using capacitors and ground posts. The conducted and radiation emissions are measured in the EMC test chamber based on standardized testing procedures of CISPR 22. The measured EMI emission values for a power converter circuit are presented and compared with the original circuit. The results show that the unwanted emissions from the circuit are tremendously diminished due to the applied EMI reduction techniques. The results proposed here can be usefully applied on designing power converter modules.

Determination of First Flush Criteria in Highway Stormwater Runoff using Dynamic EMCs (동적 EMC를 이용한 고속도로 초기우수 처리 기준 산정)

  • Kim, Lee-Hyung;Lee, Eun-Ju;Ko, Seok-Oh;Kim, Sung-Gil;Lee, Byung-Sik;Lee, Joo-Kwang;Kang, Hee-Man
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.294-299
    • /
    • 2006
  • The Ministry of Environment in Korea has introduced Total Pollution Load Management System (TPLMS) in major 4 large rivers to protect the water quality from possible pollutants. In order to successfully achieve the TPLMS, the nonpoint source should be controled by applying the best management practices in highly polluted areas. Of the various nonpoint sources, the highways are stormwater intensive landuses because of its high imperviousness and high pollutant mass emissions. The EMC (Event Mean Concentration) is an important parameter to correctly determine the pollutant mass loadings from nonpoint sources. However, it has wide ranges because of various reasons such as first flush phenomenon, rainfall and watershed characteristics. Even though the EMC is closely related to the first flush phenomenon, the relationship have not proven until present. Therefore, in this paper, the dynamic EMC method will be introduced to clearly make the relationship between EMC and first flush phenomenon. Also by applying the dynamic EMC method to monitored data, we found that the highly concentrated stormwater runoff was washed off within 20~50 minutes storm duration. The first flush criteria for economical treatment was also determined to 5~10 mm (mean=7.4 mm) as a cumulative rainfall.

Determination of EMC and Unit Loading of Rainfall Runoff from Forestry-Crops Field (산림과 밭 지역 강우 유출수의 EMC 및 원단위 산정)

  • Won, Chul-hee;Choi, Yong-hun;Seo, Ji-yeon;Kim, Ki-cheol;Shin, Min-hwan;Choi, Joong-dae
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.615-623
    • /
    • 2009
  • The research of the determination of event mean concentration (EMC) was focussed combined sewer overflows and highway runoff in korea. But those of non-urban areas are few. In this study, EMC and unit loading on land use types in Nogok watershed were estimated by runoff loading of non-point source (NPS) on non-urban area. Two monitoring sites were equipped with an automatic velocity meter, flow meter, and water sampler. Monitoring was conducted at two monitering site during the rainy season. The results show that the EMC ranges in forest land use are 1.3~2.6 mg/L for BOD, 2.0~16.1 mg/L for SS, 0.1~2.1 mg/L for TN, and 0.12~0.49 mg/L for TP. The unit loading of NPS in this study was difficult to compare directly with that used conventionally because of the difference of field investigation. In near future, it needs to conduct more systematic and long-term research about NPS within the watershed. The results of this research can be used to estimate the total pollution load management system (TPLMS) program in korea.