• Title/Summary/Keyword: EM1

Search Result 1,146, Processing Time 0.027 seconds

Induction of Chlorophyll Deficient Mutant Plant of Cymbidium kanran by EMS Treatment (EMS처리에 의한 한란의 엽록소 결핍 돌연변이 식물체의 유도)

  • 이효연;정재성;이종석
    • Korean Journal of Plant Tissue Culture
    • /
    • v.25 no.3
    • /
    • pp.183-187
    • /
    • 1998
  • Chlorophyll mutants were produced by treating the rhizome of Cymbidium kanran with mutagen, EMS(ethyl methan sulfonate). The germination ratio of Cymbidium kanran seeds was 5.5 times higher when the seeds were treated with ultrasonic treatment for 20 minutes than untreated control. Fifty to sixty percent of the rhizomes became dark brown when they were cultured in a liquid growth medium containing 0.2% EMS for three weeks. When the dark-brown rhizomes were cultured in a solified MS medium, new rhizomes were developed from a part of the old ones. Chlorophyll mutant rhizomes were obtained from a meristem tissue by a subculturing the cuts of these new rhizomes for a year. Of the chlorophyll mutants, a zigzag-striped type of rhizome was dominant and light-yellow and albino ones were also produced. While the zigzag-striped type rhizomes were differentiated into green and striped plant, the light yellow and the white rhizomes produced yellow-striped and albino plants repectively.These results indicate that the EMS treatment on the rhizome is an effective means to induce a chlorophyll mutant. We believe that this method may be useful to produce variegated plants chlorophyll mutants from other orchids.

  • PDF

An Approach to Survey Data with Nonresponse: Evaluation of KEPEC Data with BMI (무응답이 있는 설문조사연구의 접근법 : 한국노인약물역학코호트 자료의 평가)

  • Baek, Ji-Eun;Kang, Wee-Chang;Lee, Young-Jo;Park, Byung-Joo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.2
    • /
    • pp.136-140
    • /
    • 2002
  • Objectives : A common problem with analyzing survey data involves incomplete data with either a nonresponse or missing data. The mail questionnaire survey conducted for collecting lifestyle variables on the members of the Korean Elderly Phamacoepidemiologic Cohort(KEPEC) in 1996 contains some nonresponse or missing data. The proper statistical method was applied to evaluate the missing pattern of a specific KEPEC data, which had no missing data in the independent variable and missing data in the response variable, BMI. Methods : The number of study subjects was 8,689 elderly people. Initially, the BMI and significant variables that influenced the BMI were categorized. After fitting the log-linear model, the probabilities of the people on each category were estimated. The EM algorithm was implemented using a log-linear model to determine the missing mechanism causing the nonresponse. Results : Age, smoking status, and a preference of spicy hot food were chosen as variables that influenced the BMI. As a result of fitting the nonignorable and ignorable nonresponse log-linear model considering these variables, the difference in the deviance in these two models was 0.0034(df=1). Conclusion : There is a lot of risk if an inference regarding the variables and large samples is made without considering the pattern of missing data. On the basis of these results, the missing data occurring in the BMI is the ignorable nonresponse. Therefore, when analyzing the BMI in KEPEC data, the inference can be made about the data without considering the missing data.

A Low-noise Multichannel Magnetocardiogram System for the Diagnosis of Heart Electric Activity

  • Lee, Yong-Ho;Kim, Ki-Woong;Kim, Jin-Mok;Kwon, Hyuk-Chan;Yu, Kwon-Kyu;Kim, In-Seon;Park, Yong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.154-163
    • /
    • 2006
  • A 64-channel magnetocardiogram (MCG) system using low-noise superconducting quantum interference device (SQUID) planar gradiometers was developed for the measurements of cardiac magnetic fields generated by the heart electric activity. Owing to high flux-to-voltage transfers of double relaxation oscillation SQUID (DROS) sensors, the flux-locked loop electronics for SQUID operation could be made simpler than that of conventional DC SQUIDs, and the SQUID control was done automatically through a fiber-optic cable. The pickup coils are first-order planar gradiometers with a baseline of 4 em. The insert has 64 planar gradiometers as the sensing channels and were arranged to measure MCG field components tangential to the chest surface. When the 64-channel insert was in operation everyday, the average boil-off rate of the dewar was 3.6 Lid. The noise spectrum of the SQUID planar gradiometer system was about 5 fT$_{rms}$/$\checkmark$Hz at 100 Hz, operated inside a moderately shielded room. The MCG measurements were done at a sampling rate of 500 Hz or 1 kHz, and realtime display of MCG traces and heart rate were displayed. After the acquisition, magnetic field mapping and current mapping could be done. From the magnetic and current information, parameters for the diagnosis of myocardial ischemia were evaluated to be compared with other diagnostic methods.

Implementation of Wireless Power Transmission System for Multiple Receivers Considering Load Impedance Variation (부하 임피던스 변화를 고려한 복수 수신기 무선전력전송 구현)

  • Kim, Young Hyun;Park, Dae Kil;Koo, Kyung Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.2
    • /
    • pp.148-153
    • /
    • 2018
  • This paper proposes a single-input multiple-output (SIMO) self-resonant wireless power transmission system for transmitting power to multiple receivers and the characteristics are simulated and measured. A 600 mm diameter transmission single loop, a 600 mm diameter helical transmission resonant coil, an external diameter 900 mm planar spiral reception resonant coil, and an $80{\times}60mm^2$ flat plate square coil as a receiver are used to form a wireless power transmission system 600 mm away with the table structure. For optimal characteristics, the wireless power transmission coils are designed by EM simulation and equivalent circuit analysis, and the characteristics are simulated and measured. The variation of the efficiency with distance from the center of the spiral resonant coil is analyzed and the measured efficiency is 57% for one receiver and for the two receivers, the efficiency is 37% for each receiver.

Ceramic color differences of dental Ni-Cr alloy by compositional change (치과용 Ni-Cr 합금의 조성에 따른 세라믹의 색차 분석)

  • Kim, Sa-Im;Kim, Tae-Yeon;Kim, Se-Ha;Kang, Jeong-Gyu;Lee, Jung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.168-174
    • /
    • 2021
  • Purpose: This study was conducted to investigate alloys spectrophotometrically including yttrium of nickel-chromium (Ni-Cr) alloys, which are used as substitutes for the regulation of beryllium and provide helpful improvements in Ni-Cr alloys. Methods: Four groups of specimens (ZN, ZY, SN and EM) were prepared for analysis. Color parameters were measured with a spectrophotometer, and color difference (∆E*) was calculated. The t-test and one-way analysis of variance test were used to determine significant difference, and the Tukey test was used to identify where the differences were. To measure the spectroscopic reflectivity, the spectroscopic reflectance was measured and converted into CIE L*, a*, b* color system. Results: The ∆E* value of each metal ceramic group after opaque firing of Ni-Cr alloy with and without yttrium was <2, and the total group color difference (∆E*) was below 1 in the dentin ceramic all experimental group. However, the a* and b* values of the metal ceramic groups were higher than that in the lithium disilicate all ceramic group, and the chroma was higher than the natural tooth. The brightness of all experimental groups was similar to that of the shade guide sample. Conclusion: Yttrium added to Ni-Cr alloys showed similar CIE L*, a*, b* values to Ni-Cr alloys that did not contain yttrium, indicating that yttrium had no effect on color in metallic ceramic systems.

Structural Insights into Porphyrin Recognition by the Human ATP-Binding Cassette Transporter ABCB6

  • Kim, Songwon;Lee, Sang Soo;Park, Jun Gyou;Kim, Ji Won;Ju, Seulgi;Choi, Seung Hun;Kim, Subin;Kim, Na Jin;Hong, Semi;Kang, Jin Young;Jin, Mi Sun
    • Molecules and Cells
    • /
    • v.45 no.8
    • /
    • pp.575-587
    • /
    • 2022
  • Human ABCB6 is an ATP-binding cassette transporter that regulates heme biosynthesis by translocating various porphyrins from the cytoplasm into the mitochondria. Here we report the cryo-electron microscopy (cryo-EM) structures of human ABCB6 with its substrates, coproporphyrin III (CPIII) and hemin, at 3.5 and 3.7 Å resolution, respectively. Metal-free porphyrin CPIII binds to ABCB6 within the central cavity, where its propionic acids form hydrogen bonds with the highly conserved Y550. The resulting structure has an overall fold similar to the inward-facing apo structure, but the two nucleotide-binding domains (NBDs) are slightly closer to each other. In contrast, when ABCB6 binds a metal-centered porphyrin hemin in complex with two glutathione molecules (1 hemin: 2 glutathione), the two NBDs end up much closer together, aligning them to bind and hydrolyze ATP more efficiently. In our structures, a glycine-rich and highly flexible "bulge" loop on TM helix 7 undergoes significant conformational changes associated with substrate binding. Our findings suggest that ABCB6 utilizes at least two distinct mechanisms to fine-tune substrate specificity and transport efficiency.

Construction of a Novel Shuttle Vector for Tetragenococcus species based on a Cryptic Plasmid from Tetragenococcus halophilus

  • Min Jae Kim;Tae Jin Kim;Yun Ji Kang;Ji Yeon Yoo;Jeong Hwan Kim
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.2
    • /
    • pp.211-218
    • /
    • 2023
  • A cryptic plasmid (pTH32) was characterized from Tetragenococcus halophilus 32, an isolate from jeotgal, Korean traditional fermented seafood. pTH32 is 3,198 bp in size with G+C content of 35.84%, and contains 4 open reading frames (ORFs). orf1 and orf2 are 456 bp and 273 bp in size, respectively, and their translation products showed 65.16% and 69.35% similarities with RepB family plasmid replication initiators, respectively, suggesting the rolling-circle replication (RCR) mode of pTH32. orf3 and orf4 encodes putative hypothetical protein of 186 and 76 amino acids, respectively. A novel Tetragenococcus-Escherichia coli shuttle vector, pMJ32E (7.3 kb, Emr), was constructed by ligation of pTH32 with pBluescript II KS(+) and an erythromycin resistance gene (ErmC). pMJ32E successfully replicated in Enterococcus faecalis 29212 and T. halophilus 31 but not in other LAB species. A pepA gene, encoding aminopeptidase A (PepA) from T. halophilus CY54, was successfully expressed in T. halophilus 31 using pMJ32E. The transformant (TF) showed higher PepA activity (49.8 U/mg protein) than T. halophilus 31 cell (control). When T. halophilus 31 TF was subculturd in MRS broth without antibiotic at 48 h intervals, 53.8% of cells retained pMJ32E after 96 h, and only 2.4% of cells retained pMJ32E after 14 days, supporting the RCR mode of pTH32. pMJ32E could be useful for the genetic engineering of Tetragenococcus and Enterococcus species.

Use of an Electric Muscle Stimulation Thigh Band and High-intensity Circuit Training to Activate the Thigh Muscle (무릎 밴드를 이용한 EMS와 High-intensity Circuit Training의 대퇴근육 활성화 효과)

  • Hanna Park;Jinhee Park;Jooyong Kim
    • Journal of Fashion Business
    • /
    • v.27 no.2
    • /
    • pp.39-51
    • /
    • 2023
  • The purpose of this study was to effectively improve the thigh muscles of adult women working from home due to COVID-19. In this study, ten adult women working from home performed 1) an electromyography test, 2) a static balance test on a balance board, and a 3) dynamic balance test by squatting on a Bosu ball four times: before electric muscle stimulation (EMS), after EMS, after high-intensity circuit training (HICT), and after EMS plus HICT. For this test, EMS was attached to a medical knee support to manufacture an EMS knee band that could be easily worn regardless of the location. For the experiment, EMS(electric muscle stimulation) was attached to the medical knee protector to manufacture an EMS knee band that can be easily worn regardless of location, and was measured based on the right foot. The study results confirmed that in all tests (electromyography test, static balance test on the balance board, and dynamic balance test by squatting on a Bosu ball), thigh strength improved in the order of treatment before EMS, after EMS, after HICT, and after EMS plus HICT. The study showed that people working from home or with activity restrictions due to COVID-19 had better exercise effects when wearing the EMS knee band and performing HICT, even in a small space.

Reference values for pulp oxygen saturation as a diagnostic tool in endodontics: a systematic review and meta-analysis

  • Paula Lambert;Sergio Augusto Quevedo Miguens Jr;Caroline Solda;Juliana Tomaz Sganzerla;Leandro Azambuja Reichert;Carlos Estrela;Fernando Branco Barletta
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.48.1-48.11
    • /
    • 2020
  • Objectives: This systematic review aimed to identify mean oxygen saturation values (SpO2) using pulse oximetry in permanent maxillary anterior teeth. Materials and Methods: The MEDLINE, Scientific Electronic Library Online, Cochrane Central Register of Controlled Trials, EMBASE, and Literatura Latino Americana em Ciências da Saúde electronic databases were searched. Combinations and variations of "oximetry" AND "dental pulp test" were used as search terms. Studies reporting means and standard deviations of SpO2 values were included. Two reviewers independently extracted data following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist. Heterogeneity was assessed using the I2 statistic, and all analyses were performed using R software. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool and the Newcastle-Ottawa scale. Results: Of the 251 studies identified, 19 met the eligibility criteria and were included (total sample, 4,541 teeth). In the meta-analysis, the mean SpO2 values were 84.94% (95% confidence interval [CI], 84.85%-85.04%) for the central incisors, 89.29% (95% CI, 89.22%-89.35%) for the lateral incisors, and 89.20% (95% CI, 89.05%-89.34%) for the canines. The studies were predominantly low-quality due to the high risk of bias associated with the index test, unclear risk regarding patient selection, and concerns about outcome assessment. Conclusions: Although most studies were low-quality, the oxygen saturation levels in normal pulp could be established (minimum saturation, 77.52%). Despite the risk of bias of the included studies, the reference values reported herein are clinically relevant for assessments of changes in pulp status.

A Parametric Study of Flexural Stiffness Ratio on Floor Slabs for Seismic Design of Shear Wall Structures (전단벽식 구조물의 내진설계 시 합리적인 바닥판의 휨강성비 적용에 대한 연구)

  • Oh, Soon-Taek;Lee, Dong-Jun;Em, Young-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.6 s.58
    • /
    • pp.148-155
    • /
    • 2009
  • A remarkable discrepancy of lateral deformation of shear wall structures for seismic loads due to a rigid diaphragm assumption without floor slab modelling asks a study how much effective the slab stiffness ratio is to the lateral behaviour. Typical shear wall type 15 stories structure is selected to analysis using MIDAS-ADS2008 commercial softwares modelling three types; 1) rigid diaphragm (RD model) 2) considered out-of plane slab flexural stiffness (DB model), and 3) considered in and out of plane slab flexural stiffness (SRC model). Based on National Code of KBC2005, the Equivalent Static and Response Spectrum seismic analysis are undertaken to compare each responses of the three models. The differences of lateral responses due to the three slab stiffness ratios applied on the models are compared and discussed.