• Title/Summary/Keyword: ELISA system

Search Result 327, Processing Time 0.021 seconds

Performance Evaluation of the Automated Fluorescent Immunoassay System Rotavirus Assay in Clinical Samples

  • Kim, Jae-Seok;Lee, Su-Kyung;Ko, Dae-Hyun;Hyun, Jungwon;Kim, Hyun Soo
    • Annals of Laboratory Medicine
    • /
    • v.39 no.1
    • /
    • pp.50-57
    • /
    • 2019
  • Background: The Automated Fluorescent Immunoassay System (AFIAS) rotavirus assay (Boditech Med Inc., Chuncheon, Korea) is a new rapid antigen test for rotavirus detection. We evaluated the performance of this assay for detecting rotaviruses and their specific genotypes in clinical stool samples. Methods: AFIAS rotavirus assay was performed in 103 rotavirus-positive and 103 rotavirus-negative stool samples (confirmed by both PCR and ELISA), and its results were compared with those of PCR, ELISA, and immunochromatographic assay (ICA). We evaluated diagnostic sensitivity/specificity, the detectability of rotavirus subtypes, lower limit of detection (LLOD), reproducibility, cross-reactivity, and interference of AFIAS rotavirus assay. Results: Based on PCR and ELISA results, diagnostic sensitivity and specificity of the AFIAS rotavirus assay were both 99.0%. LLOD results showed that the AFIAS assay had sensitivity similar to or greater than ICA and ELISA. High reproducibility was confirmed, and no cross-reactivity or interference was detected. This assay could detect genotypes G1P[8], G2P[4], G3P[8], G4P[6], G4P[8], G8P[4], G8P[8], G9P[4], and G9P[8]. Conclusions: The AFIAS rotavirus assay showed high reproducibility, sensitivity, and specificity as well as excellent agreement with ELISA, PCR, and ICA. It detected the most common as well as unusual genotypes of rotavirus prevalent in Korea. It could be a useful onsite assay for rapid, convenient, and cost-effective detection of rotavirus infection.

Competitive Enzyme-Linked Immunosorbent Assay for Detection of Gentamicin Residues in Edible Animal products (축산식품 중에 잔류하는 Gentamicin 검사를 위한 ELISA 개발에 관한 연구)

  • Kim, Jae-Myung;Lee, Mun-Han;Lee, Hang;Ryu, Pan-Dong;Cho, Myung-Haing;Park, Jong-Myung
    • Journal of Food Hygiene and Safety
    • /
    • v.9 no.3
    • /
    • pp.123-131
    • /
    • 1994
  • An enzyme-linked immunosorbent assay(ELISA) was developed for the detection of residual gentamicin(GM) in edible animal products. The immunogen(GM-KLH conjugate) and coating antigen(GM-BSA conjugate) were prepared by coupling GM sulfate to keyhole limpet hemocyanin(KLH) and bovine serum albumin(BSA) in the presence of 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride, respectively. Polyclonal antibody to GM was produced in rabbits(New Zealand White, female) by using the immunogen and the antibody titer was measured by indirect ELISA. A competitive ELISA was developed using GM-bovine serum albumin conjugate as a coating antigen, GM(as standards or sample), polyclonal antibody to GM, secondary antibody conjugated with horseradish peroxidase as an enzyme, and H2O2 and o-phenylenediamine dihydrochloride as a substrate and a chromophore, respectively. The detection limit of GM was 10 ng/ml and the standard curve of GM(n=26) was linear up to 10 $\mu\textrm{g}$/ml in this competitive ELISA system. There were no cross-reactivities of the partially purified antibody between GM and the various antibiotice such as amikacin, benzyl-penicillin, chloramphenicol, erythromycin, furazlidone, kanamycin, neomycin, oleandomycin, streptomycin, sulfathiazole and thiamphenicol(CR50<0.05%)

  • PDF

Use of the enzyme-linked immunosorbent assay for the detection of toxoplasmosis in swine (ELISA를 이용한 돼지 톡소플라스마병의 조기 진단에 관한 연구)

  • Suh, Myung-deuk;Jang, Dong-hwa;Joo, Hoo-don
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.4
    • /
    • pp.567-575
    • /
    • 1989
  • This study was conducted to evaluate the possibility of application of a microenzyme-linked immunosorbent assay(micro-ELISA) for the serodiagnosis of specific toxoplasma antibodies in swine sera and this test was performed as a microplate system by coating the polystyrene plates with toxoplasma soluble antigen, incubated serially diluted sera, then added horse radish peroxidase labelled goat anti-swine IgG(r) conjugate followed by o-phenylenediamine as substrate. The color development by enzyme-substrate reaction was determined by the photometric reading [ELISA reader at 490nm (OD)] and visual reading. The soluble antigen was prepared from the tachyzoites in mouse peritoneal cavity. A total of 1,200 swine sera from pig slaughter-house and a total of 116 swine sera from pig breeding station (S-C farm) were tested for the detection of antibodies to Toxoplasma gondii. The results obtained were summarized as follows: 1. The optimal reactions of indirect ELISA for the test sera were determined by the dilution of antigen 1:256 and 1:3,200 of horse radish peroxidase conjugate [anti-swine IgG(r)]. 2. The specific togoplasma antibody(IgG) in pigs infected with Tp artificially were detected as the serum titers of 1:64 or 1:128 at one week postinfection. 3. Of a total of 1,200 swine sera from pig slaughter-house 505 samples of sera were detected as positive (42.1%) and of a total of 116 swine sera from S-C pig breeding station 68 samples of sera as positive (58.6%). 4. The specific antibody(IgG) detection rates against a total of 1,200 test sera from pig slaughter-house were not significant between male (43.1%) and female (40.7%). 5. The indirect ELISA was proved to be a sensitive and specific procedure for the serodiagnosis of swine toxoplasmosis and also evaluated as an effective screening test for the large scale of test samples in laboratory.

  • PDF

Prevalence of antibody and toxin against edema disease from pig farms in Jeonbuk province (전북지역 양돈장에서의 돼지 부종병 항체 및 톡신 양성률 조사)

  • Sun-Young Cho;Jeong Hee Yu;Yeong Ju Yu;Han-Jun Lee;Jin Hur
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.4
    • /
    • pp.325-334
    • /
    • 2023
  • Edema disease (ED) in pigs is enterotoxemia caused by Shiga toxin type 2e (Stx2e)-producing Escherichia coli (STEC) and frequently occurs in young piglets. Therefore, ED causes enormous economic losses in pig farms. In this study, a modified Stx2e (mStx2e) antigen was expressed and purified using commercial E. coli expression system. Monoclonal antibody was serviced by Ynto Ab Inc., using Phage Display Technique. Anti-Stx2e antibodies in piglets were measured by indirect ELISA using mStx2e antigens. Naive Stx2e in piglets were detected by Sandwich ELISA using Stx2e-monoclonal antibodies and commercial Stx2e-polyclonal antibodies. Among 3,480 piglets, anti-Stx2e antibodies were observed in 2,573 piglets. The 49.4% among 830 piglet serum samples possessed 0.625 ㎍/mL or more of Stx2e proteins. The 18.3% of 830 sera had 0.313 ㎍/mL of Stx2e proteins. The 32.3% of 830 samples held 0.156 ㎍/mL or less of Stx2e proteins. These results show that indirect ELISA using mStx2e antigen and Sandwich ELISA using Stx2e-monoclonal and polyclonal antibodies can be useful to detect ED in piglets.

Enzyme-linked Immunosorbent Assay for the Detection of Hen's Egg Proteins in Processed Foods

  • Shon, Dong-Hwa;Kim, Hyun-Jung;Kim, Soo-Ho;Kwak, Bo-Yeon
    • Food Science of Animal Resources
    • /
    • v.30 no.1
    • /
    • pp.36-41
    • /
    • 2010
  • The Hen's egg is widely used in many processed foods as an ingredient and is one of the most prevalent food allergens in children. To detect egg proteins in processed foods, we developed a competitive indirect enzyme-linked immunosorbent assay (ciELISA) using an anti-ovomucoid (OM) antibody, which was produced by immunization of rabbits with OM, the most heat-stable component of the egg proteins. The detection limit of this quantitative assay system was 30 ng/mL. Cross-reactivity of the anti-OM antibody toward OM, ovalbumin, skim milk, casein, whey protein isolate, and isolated soy protein was 100, 0.4, 0.2, 0.04, 0, and 0%, respectively. In the spike test of egg white powder in milk replacer, commercial sausage, and in-house sausage, the assay recoveries ($mean{\pm}SD$) were $129{\pm}13.7%$, $73.9{\pm}12.5%$, and $65.5{\pm}13.6%$, respectively. When egg white in a commercial crab meat analog and sausage was determined by ciELISA, the assay recovery was found to be 108% and 127%, respectively. The combined results of this study indicate that this novel ciELISA for OM detection could be applied for the quantification of hen's egg proteins in processed foods.

Early Detection of Epiphytic Anthracnose Inoculum on Phyllosphere of Diospyros kaki var. domestica

  • Lee, Jung-Han;Han, Ki-Soo;Lee, Sun-Cheol;Shim, Chang-Ki;Bae, Dong-Won;Kim, Dong-Kil;Kim, Hee-Kyu
    • The Plant Pathology Journal
    • /
    • v.20 no.4
    • /
    • pp.247-251
    • /
    • 2004
  • We developed a polyclonal antibody (PAh) based- ELISA system to accurately and rapidly monitor inocula on plant surface before onset of anthracnose. Titer of mouse antisera against conidia of Colletotrichum gloeosporioides was determined by using indirect ELISA. It was high enough to be detectable up to ${\times}$ 12,800 dilutions. Absorbance readings exceeded (1.5even at a 10$^{-5}$ dilution. Sensitivity of PAb was precise enough to detect spore concentration as low as 50 conidia/well by indirect ELISA. PAb1 and PAb2 proved to be very sensitive and highly specific to the target pathogen, C. gloeosporioides, apparently discriminating other unrelated pathogens, or epiphytes. Absorbance values for original isolate exceeded 1.0, but no reaction was detected with other isolates, except three other anthracnose fungi: C. gloeosporioides (pepper strain), Glomerella cingulata (apple strain) and C. lagenarium. Our data suggest that PAb1 and PAb2 bind with the protein epitope that partially contains residues of amino acid, arginine, and Iysine. This kit fulfills the require-ments for detecting inoculums before infection and during onset of anthracnose on sweet persimmon.

Analysis of Microtoxins in the Nakdong River Watershed

  • Park, Jung-Min;Lee, Jae-Jung;Hwang, Dong-Jin;Yang, Sang-Yong
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.99-102
    • /
    • 2003
  • The different methods such as HPLC, indirect- and direct-ELISA were employed for the analysis of microtoxins and the results of each method were compared in terms of the detection limit and accurary. Three toxins, microcystin-RR, -LR and -YR were clearly separated by HPLC using 0.05 M methanol and phosphate buffer used as a solvent system. The calibration curves for the toxins were linear in the range of 5 ng to 50 ng. The standard curves for the immunoassay of microcystin obtained by direct and indirect ELISA are compared. The linear responses of inhibitions of binding by microcystin in the direct and indirect competitive ELISA were in the range of 10 ng to 1000 ng and 50 pg to 160 pg, respectively. Distribution of microtoxins at 11 sites in the Nakdong river and several lakes in Korea was also studied. The most dominant microcystin variant in the test sites was found to be microcystin-RR.

  • PDF

Studies on the Epitope of Neuronal Growth Inhibitory Factor (GIF) with Using of the Specific Antibody

  • Pang, Li-Yan;Ru, Bing-Gen
    • BMB Reports
    • /
    • v.38 no.6
    • /
    • pp.646-649
    • /
    • 2005
  • Human neuronal growth inhibitory factor (GIF), a metalloprotein classified as metallothionein-3, is specifically expressed in mammal central nervous system (CNS). In these Studies the specific antibody to human GIF was prepared and used to search the epitope of human GIF by enzyme-linked immunosorbent assay (ELISA) and sequence comparison. The result of ELISA showed the epitope of human GIF may locate on a octapeptide (EAAEAEAE) in the $\alpha$-domain of human GIF, and the result of nerve cell culture indicated that the biological activity of GIF may be affected by the specific antibody.

Development of a Disperse Dye Immunoassay Technique for Detection of Antibodies against Neospora caninum in Cattle

  • Selahi, Fatemeh;Namavari, Mehdi;Hosseini, Mohammad Hossein;Mansourian, Maryam;Tahamtan, Yahya
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.1
    • /
    • pp.129-132
    • /
    • 2013
  • In this study a disperse dye immunoassay method was standardized and evaluated for detection of antibodies against Neospora caninum in cattle. Sera from 150 cattle with a recent history of abortion were collected and tested by commercial ELISA kit and a standardized in-house dye immunoassay system. The positivity rate for the sera used in this study was 34.6% for the disperse dye immunoassay (DDIA) compared to 32% obtained by ELISA kit. This study showed no significant difference between DDIA and ELISA. The results indicated that the DDIA provide an economic, simple, rapid and robust test for detection of N. caninum infection in cattle.

Ultra-Sensitive Analysis of Microcystin LR Using Microchip Based Detection System

  • Pyo, Dong-Jin;Huang, Yan;Kim, Young-Min;Hahn, Jong-Hoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.939-942
    • /
    • 2005
  • For the detection of cyanobacterial toxin, an Enzyme-linked immunosorbent assay (ELISA) was integrated into a PDMS microchip. The conjugates of microcystin-LR (MCLR) and keyhole limpet hemocyanin (KLH) were adsorbed on the surface of polystyrene beads and these MCLR-KLH polystyrene beads were introduced into a microchamber. MCLR on the surface of polystyrene beads reacted with horseradish peroxides (HRP) conjugated anti-MCLR monoclonal antibody (mAb) which had a competitive reaction with MCLR in water sample. After the enzyme substrate 3,3,5,5-tetramethyl benzidine (TMB) was injected into the chamber and catalyzed by HRP, the color change was detected with a liquid-cord waveguide. This integration shortened the conventional ELISA analysis time from several hours to about 30 min with only 4.2 $\mu$L MCLR sample consuming which was useful for the environmental analysis. More over, troublesome operations required for ELISA could be replaced by simple operations. The microchip based detection system showed a good sensitivity of 0.05 $\mu$g/L and maintained good reliability through its quantitative range with low coefficients of variation (2.5-10.5%).