• Title/Summary/Keyword: ELISA kit

Search Result 337, Processing Time 0.03 seconds

Rapid Detection of Infectious Bursal Disease Virus (IBDV) in Chickens by an Immunochromatographic Assay Kit

  • Choi, Kang-Seuk;Oh, Jin-Sik;Jeon, Woo-Jin;Na, Keon-Sok;Lee, Eun-Kyoung;Lee, Youn-Jeong;Sung, Hwan-Woo;Ha, Gun-Woo;Kwon, Jun-Hun
    • Korean Journal of Poultry Science
    • /
    • v.37 no.2
    • /
    • pp.167-172
    • /
    • 2010
  • An immunochromatograhy (IC) based infectious bursal disease virus (IBDV) detection kit, which employed two anti-IBDV VP2 monoclonal antibodies, was evaluated for rapid diagnosis of infectious bursal disease virus (IBD). The detection limit of the IC kit for IBDV was $10^{3.1}$ to $10^{3.9}$ $EID_{50}$/mL, indicating that the IC kit detected IBDV sensitively as same as double antigen capture ELISA but less than a RT-PCR assay. The IC kit did not detect other viral pathogens such as Newcastle disease virus, infectious bronchitis, avian influenza virus, and infectious larynotracheitis virus. When applied to tissue samples of experimental chickens died 3 or 4 days post infection after very virulent IBDV (strain Kr/D62) infection, the IC kit detected IBDV in all samples of the bursa of Fabricius, spleen, kidney, cecal tonsil and in 87.5%, 37.5% and 0% of liver, thymus and proventriculus samples. In particular, BF tissue samples showed stronger signal bands than other tissues. Positive signal was observed. All except for one thymus sample of samples having negative results by the IC kit showed the same result with DAS-ELISA but RT-PCR assay detected IBDV in some of IC kit negative samples of thymus and proventriculus. When swab samples from the bursa of Fabricius of dead chickens (n=231) on field farms were tested, the sensitivity and specificity of the IC assay relative to RT-PCR was 100% (109/109) and 97.5% (119/122), respectively and kappa value between both assay was 0.97. The kit can provide a useful aid for rapid detection of IBDV in chickens under field circumstances.

Quantitative Method of Rapid Immunochromatographic Assay Kit for HBsAg-screening using Computer Image Analysis (컴퓨터 상 분석을 이용한 HBsAg-screening용 Rapid Immunochromatographic Assay Kit의 정량적 측정법)

  • 신형순;허태련
    • KSBB Journal
    • /
    • v.15 no.3
    • /
    • pp.243-246
    • /
    • 2000
  • One of recent topics in the case of hepatits B virus(HVB) is the value of hepatitis B surface antigen(HBsAg) concentration as a prognostic maker. We developed uantitative method of rapid immunochromatographic assay(ICA) kit for HBsAg using computer image analysis (CIA) for the purpose of home diagnosis. uantitative ICA using CIA demonstrated integrated optical density(IOD) values proportional to log of reference HBsAg concentrations in the range of 2-200 ng/mL and enzyme-linked immunosorbent assay(ELISA) demonstrated the same in the range of 0.1-100 ng/mL however the test results with sample sear showed the same concentration on both kits. Furthermore repeated tests with the same samples revealed that this quantitative ICA using CIA would be reproducible and coefficient of variation(CV) of the results was 1.38~6.30%.

  • PDF

Development and Clinical Evaluation of a Rapid Serodiagnostic Test for Toxoplasmosis of Cats Using Recombinant SAG1 Antigen

  • Chong, Chom-Kyu;Jeong, Woo-Seog;Kim, Hak-Yong;An, Dong-Jun;Jeoung, Hye-Young;Ryu, Jeong-Eun;Ko, A-Ra;Kim, Yong-Joo;Hong, Sung-Jong;Yang, Zhaoshou;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.49 no.3
    • /
    • pp.207-212
    • /
    • 2011
  • Rapid serodiagnostic methods for Toxoplasma gondii infection in cats are urgently needed for effective control of transmission routes toward human infections. In this work, 4 recombinant T. gondii antigens (SAG1, SAG2, GRA3, and GRA6) were produced and tested for the development of rapid diagnostic test (RDT). The proteins were expressed in Escherichia coli, affinity-purified, and applied onto the nitrocellulose membrane of the test strip. The recombinant SAG1 (rSAG1) showed the strongest antigenic activity and highest specificity among them. We also performed clinical evaluation of the rSAG1-loaded RDT in 182 cat sera (55 household and 127 stray cats). The kit showed 0.88 of kappa value comparing with a commercialized ELISA kit, which indicated a significant correlation between rSAG1-loaded RDT and the ELISA kit. The overall sensitivity and specificity of the RDT were 100% (23/23) and 99.4% (158/159), respectively. The rSAG1-loaded RDT is rapid, easy to use, and highly accurate. Thus, it would be a suitable diagnostic tool for rapid detection of antibodies in T. gondii-infected cats under field conditions.

Quality Evaluation of Five Commercial Enzyme Linked Immunosorbent Assay Kits for Detecting Aflatoxin B1 in Feedstuffs

  • Sun, Dan-Dan;Gu, Xu;Li, Jun-Guo;Yao, Ting;Dong, Ying-Chao
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.5
    • /
    • pp.691-696
    • /
    • 2015
  • The objective of this study was to evaluate the quality of five commercial enzyme linked immunosorbent assay (ELISA) kits (A, B, C, D, and E) from different suppliers for detecting aflatoxin $B_1$ ($AFB_1$). $AFB_1$-free corn samples supplemented with different levels of $AFB_1$ (5, 10, and $20{\mu}g/kg$) were used as positive controls and 6 replicates of each control sample were tested to evaluate the accuracy and precision of these kits. In addition, we also evaluated the performance of these ELISA kits for $AFB_1$ in 30 feed samples, including corn, distillers dried grains with soluble, wheat samples, soybean meal, and poultry feed, which were verified by high performance liquid chromatography. Results showed that the coefficients of variation ranged from 1.18% to 16.22% in intra-plate and 2.85% to 18.04% in inter-plate for the determination of $AFB_1$. The half maximal inhibitory concentration for five kits ranged from 3.72 to $7.22{\mu}g/kg$. The quantitation limits of $AFB_1$ were all under the legal limit in China but somewhat inconsistent with kit instructions. Although the recovery rate of four of the five kits were either less than 90% or more than 110%, all these values were acceptable in practice. Two kits had high false positive rates (C and E). In conclusion, our results revealed that the qualities of five tested ELISA kits were significantly different.

Inhibition of MMP-2 and -9 by Crude Extracts and Their Solvent-partitioned Fractions from the Halophyte Atriplex gmelinii (가는갯능쟁이(Atriplex gmelinii) 추출물과 용매분획물의 MMP-2와 MMP-9 활성 저해효과)

  • Park, Min Jeong;Kim, Junse;Kong, Chang-Suk;Seo, Youngwan
    • Ocean and Polar Research
    • /
    • v.41 no.2
    • /
    • pp.79-88
    • /
    • 2019
  • In this study, the inhibitory effect of Atriplex gmelinii C. A. Mey. against the activity of MMP-2 and MMP-9 secreted from phorbol-12-myristate-13-acetate (PMA)-stimulated HT-1080 cells was evaluated by gelatin zymography and enzyme-linked immunosorbent assay (ELISA), reverse transcription polymerase-chain reaction (RT-PCR), and Western blot assay. Specimens of the halophyte A. gmelinii were extracted twice for 24 hr with methylene chloride ($CH_2Cl_2$), and then twice with methanol (MeOH), in turn. Each extract significantly inhibited the enzymatic activities in gelatin zymography and MMP ELISA kit, and expression of MMP-2 and 9 in mRNA and protein levels. Two crude extracts were combined and then the combined crude extracts were fractionated into n-hexane, 85% aqueous methanol (85% aq.MeOH), n-butanol (n-BuOH), and water ($H_2O$) fractions, according to solvent polarity. Among solvent-partitioned fractions, the 85% aq.MeOH fraction showed the strongest inhibitory effect against MMP-2 and -9 in gelatin zymography and MMP ELISA kit. In RT-PCR, all solvent-partitioned fractions significantly suppressed mRNA expression of MMP-2 and -9. On the other hand, in Western blot assay, all solvent-partitioned fractions except $H_2O$ significantly reduced expression levels of protein. HT 1080 cell migration was most significantly inhibited by the n-BuOH fraction followed by the 85% aq.MeOH and $H_2O$ fractions. These results suggest that A. gmelinii could be used as a potential source to inhibit tumor cell metastasis.

Early Detection of Epiphytic Anthracnose Inoculum on Phyllosphere of Diospyros kaki var. domestica

  • Lee, Jung-Han;Han, Ki-Soo;Lee, Sun-Cheol;Shim, Chang-Ki;Bae, Dong-Won;Kim, Dong-Kil;Kim, Hee-Kyu
    • The Plant Pathology Journal
    • /
    • v.20 no.4
    • /
    • pp.247-251
    • /
    • 2004
  • We developed a polyclonal antibody (PAh) based- ELISA system to accurately and rapidly monitor inocula on plant surface before onset of anthracnose. Titer of mouse antisera against conidia of Colletotrichum gloeosporioides was determined by using indirect ELISA. It was high enough to be detectable up to ${\times}$ 12,800 dilutions. Absorbance readings exceeded (1.5even at a 10$^{-5}$ dilution. Sensitivity of PAb was precise enough to detect spore concentration as low as 50 conidia/well by indirect ELISA. PAb1 and PAb2 proved to be very sensitive and highly specific to the target pathogen, C. gloeosporioides, apparently discriminating other unrelated pathogens, or epiphytes. Absorbance values for original isolate exceeded 1.0, but no reaction was detected with other isolates, except three other anthracnose fungi: C. gloeosporioides (pepper strain), Glomerella cingulata (apple strain) and C. lagenarium. Our data suggest that PAb1 and PAb2 bind with the protein epitope that partially contains residues of amino acid, arginine, and Iysine. This kit fulfills the require-ments for detecting inoculums before infection and during onset of anthracnose on sweet persimmon.

Diagnosis of porcine reproductive and respiratory syndrome (PRRS) and its serological survey using the reverse transcription and polymerase chain reaction (RT-PCR) and ELISA (RT-PCR과 ELISA를 이용한 PRRS 진단 및 항체가 조사)

  • Chu Keum-Suk;Han Keu-Sam;Han Jae-Cheol;Song Hee-Jong
    • Korean Journal of Veterinary Service
    • /
    • v.27 no.3
    • /
    • pp.273-280
    • /
    • 2004
  • The studies were performed for the PRRS antigen and antibody detection from breeding farms, artificial insemination(AI) center and growing farms in Jeonbuk province. 1. Specific PRRS primers were successfully amplified ORF6 617bp and ORF7 448 bp on agarose gel. 2. RT-PCR method has been establish by commercial kit and the thermal cycler program consisted of 30 cycles: $95^{\circ}C$ for 30 sec, $45^{\circ}C$ for 30 sec, and $72^{\circ}C$ for 45 sec. 3. The results of PRRS antibody test by ELISA method in AI centers were $6.6\%,\;53.3\%$ and breeding farms $65\%,\;65\%\;and\;38.7\%$, respectively. The serological positive of the antibody in gilt higher than sow. 4. The sero-positive of the PRRS antibody showed average $21\%$ in domestic farms, $56.2\%$ in breeding farms, and $29.9\%$ in AI center.

Toxoplasma antibody titers by ELISA and indirect latex agglutination test in pregnant women (ELISA 및 간접 latex 응집반응검사에 의한 임산부의 항 톡소포자충 항체가)

  • 류재숙;민득영
    • Parasites, Hosts and Diseases
    • /
    • v.34 no.4
    • /
    • pp.233-238
    • /
    • 1996
  • The seroepidemiologic studies on antral-ToxopIasma antibody titers were carried out using ELISA and indirect latex agglutination test. Among 899 sera prepared from pregnant women, 39 cases (4.3%) revealed positive reaction and 218 sera from middle school students showed 4 positive reaction (1.8%) by ELISA. By LAT (newly established by National Veterinary Research Institute, Korea), the sera of 7 pregnant women (0.8%) showed positive reaction. When 80 sera showing ≥ 1 :8 by LAT were used for comparing the results obtained from LAT and Toxotest-MT (Eikon Chemical Co., Japans, 7 cases and 8 sera were positive, respectively. All of 11 sera of proven toxoplasmosis patients showed positive reaction in both tests. Overall proportion of agreement between LAT kit and Toxotest-MT was 0.94 (K-index : 0.632, p < 0.01), and LAT was considered to be useful for the screening of toxoplasmosis.

  • PDF

Development of diagnostic kit(Test-MT) for the microplate latex agglutination test of toxoplasmosis in animal (Latex 응집반응을 이용한 동물의 톡소플라즈마병 진단용 kit 개발에 관한 연구)

  • Suh, Myung-deuk;Joo, Hoo-don;Maass, Daivd
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.3
    • /
    • pp.583-593
    • /
    • 1995
  • The present study was conducted to develop a toxoplasma latex agglutination test antigen(Test-MT) and evaluate the toxoplasma latex agglutination(LA) test using a newly-made "Test-MT kit" by comparing with the Toxo-MT kit(Eiken chemical co, Tokyo). Also, the specifity and sensitivity test were made by comparing with IFA test and IgG-ELISA. Tachyzoite suspensions of Toxoplasma gondii(RH strain) were ultracentrifuged for 30min at $60,000{\times}g(4^{\circ}C)$ and the supernatant was used as a water-lysate antigen. Polystyrene latex particles of $1.0{\mu}m$ in diameter(Polyscience co) were used for the preparation of sensitized latex-antigen supension(Test-MT). The frequency distribution of LA titers in Test-MT showed two peaks at <1:32 and 1:128. The borderline titer for positive test in Test-MT was determined to be 1:64. But the frequency distribution of LA tites in Toxo-MT showed two peaks at <1:16 and 1:64. The positive borderline was determined to be 1:32. Agreement of reactions between Test-MT and Toxo-MT kit by LA test was shown 92.5% in bovine sera and 97.0% in swine sera, respectively. From the results obtained here it was determined that the sensitized latex-antigen, Test-MT kit, for the microtiter agglutination test prepared as same as by the procedure described in the previous paper(Suh and Lee, 1993) was useful as a highly specific, sensitive and stable immunotiteration reagent for serodiagnosis of toxoplasma infection in animal sera.

  • PDF

Usefulness of the Neutrophil Gelatinase-Associated Lipocalin (NGAL) Kit for Acute Kidney Injury Patients at the Emergency Medical Center in Daegu (대구지역 응급의료센터에 내원한 급성 콩팥손상 환자의 진단을 위한 호중구 젤라티나제 관련 리포칼린 키트의 유용성)

  • Lee, Seung-Jin;Park, Sangwook
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.49-53
    • /
    • 2016
  • Acute kidney injury (AKI) is a common syndrome resulting in kidney damage and malfunction within a few days or even a few hours. The diagnosis of AKI depends on routine biochemical tests, including serum creatinine, aspartate aminotransferase (AST), alanine aminotransaminase (ALT), blood urea nitrogen (BUN), and electrolytes. Plasma neutrophil gelatinase-associated lipocalin (NGAL) is a biomarker that shows correlation with the severity of acute infections and kidney injuries. The predictive value in other conventional assays for kidney functions has been reported to cause distraction for AKI syndrome. The aim of this study is to verify the predictive value of plasma NGAL in patients with established AKI. The NGAL kit for checkup demonstrates sensitivity of ${\geq}300$ (92.2%), ${\geq}200$ (95.6%), ${\geq}100$ (99.6%), specificity of ${\geq}300$ (95.1%), ${\geq}200$ (97.3%), ${\geq}100$ (99.4%), positive predictability of ${\geq}300$ (93.3%), ${\geq}200$ (93.4%), ${\geq}100$ (99.2%), and negative predictability of ${\geq}300$ (96.7%), ${\geq}200$ (97.7%), ${\geq}100$ (98.1%), respectively. The plasma NGAL compared with the enzyme-linked immunosorbent assay (ELISA) has been shown to be an early predictive biomarker of AKI. The NGAL kit, recently developed for point-of-care of plasma specimens, is thought to be a useful and reliable biomarker for the early diagnosis of decreased kidney functions.