• Title/Summary/Keyword: ELISA kit

Search Result 338, Processing Time 0.027 seconds

Comparison among Diagnostic Methods of Rotaviral Gastroenteritis in Children (유소아 로타바이러스 장염 진단 검사의 비교 연구)

  • Lee, Jang-Hun;Ko, Eun-Young;Kim, Jae-Oong;Lee, Jung-Hwa;Baek, Lack-Ju;Kim, Soon-Kyum
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.1
    • /
    • pp.34-40
    • /
    • 2001
  • Purpose: The purpose of this study was to evaluate the clinical efficacy of reverse transcription-polymerase chain reaction (RT-PCR) in detecting rotaviral gastroenteritis in children comparing with that of commercial immunoassays. Methods: Stools from 79 children admitted Korea University Hospital due to diarrhea were collected from December 1999 to February 2000. Immunoassays were done using commercial rotavirus Latex kit and Rotatec (ELISA) kit. RT-PCR was performed to amplify group A rotavirus, most commonly pathogenic to human, using VP4- and VP7-specific primers. The detection rates of immunoassays and RT-PCR were compared. Results: ELISA assay was superior to LA assay and moderately concordant with RT-PCR in detecting rotaviral gastroenteritis. Conclusion: Although RT-PCR is known very sensitive, it does not have significant advantage over immunoassay in detecting rotaviral gastroenteritis.

  • PDF

Development of Rapid Diagnostic Kit for Identification of Hanwoo (Korean Native Cattle) Brand Meat by Detecting BIO-TAG

  • Baek, Kyung Hoon;Park, Sung Kwon;Lee, Myung Hoon;Kim, Sung Il;Cho, Soo Hyun;Choi, Chang Bon
    • Food Science of Animal Resources
    • /
    • v.34 no.3
    • /
    • pp.339-345
    • /
    • 2014
  • This study was performed to develop a rapid immuno-assay kit, by using a specific antigen to detect Hanwoo brand meat. We selected a synthetic antigen specific to our target antibody, named BIO-TAG (Tyr-D-Ala-Phe), by utilizing a computer-based analysis and literature review. BIO-TAG tagged with adjuvant was subcutaneously injected in sheep and Hanwoo. The serum and meat juice of the immunized or non-immunized animal were then analyzed, to measure the titer of antibody by ELISA and Western blot. The amount of antibodies against the BIO-TAG increased (p<0.05) in serum by vaccination. Furthermore, meat juice from the immunized Hanwoo showed greater (p<0.05) antibody titer, compared with those from non-immunized groups. To optimze the dilution factor, we performed dot-ELISA, with various combination levels of BIO-TAG. Results from dot-ELISA showed that 2 mg/mL BIO-TAG was sufficient to distinguish the immunized meat from non-immunized groups. These results support our hypothesis that simple immunization of Hanwoo generates a sufficient amount of antibodies to be detectable in the meat juice by means of the immune-assay. Therefore, specific Hanwoo brand meat can be more precisely identified by our rapid diagnostic kit. This technology can deter possible fraud of counterfeit meat brands in the Korean domestic market with ease and rapidity; and offers a new tool that guarantees consumers high quality Hanwoo brand beef.

Changes of maternal antibodies in chicks vaccinated to breeder against infectious bronchitis, infectious Bursal disease, and Newcastle disease virus (모계의 전염성기관지염, 전염성 F낭병 및 뉴캣슬병 백신투여에 따른 모체이행 항체의 변동)

  • 고원석;김태중;이정원;서이원;송희종;오언평
    • Korean Journal of Veterinary Service
    • /
    • v.21 no.2
    • /
    • pp.133-139
    • /
    • 1998
  • Serum samples collected from 30 breeders and their progeny 30 chicks. The antibodies against infectious bronchitis(IB), infectious bursal disease (IBD) and Newcastle disease(ND) viruses were detected by ELISA using commercial ELISA kit. The breeders were vaccinated against IB, IBD and ND viruses according to general vaccination program. Geometric mean titers(GMT) of ELISA were monitored from 1-day old to 17-day old chicks and compared with breeder chickens. The GMT of ELISA to IB, IBD and ND were declined half level of the breeder antibody titer at 6-, 8- and 7-day old. And, the GMT of ELISA to IB, IBD and ND were declined than that of protective titer at 6-, 1-, and 4-day old. Thereafter, the GMT of ELISA was declined and disappeared according to ages of chicks. Taken together, this study led to conclusion that time-course of maternal antibody titers of chicks from vaccinated breeders, and this is very important data for vaccination to chicks.

  • PDF

Method validation for quantitative analyzing aflatoxin productivity in Aspergillus sp. isolated from soybean paste

  • SeongEui Yoo;WooSoo Jeong;Soo-Hwan Yeo;So-Young Kim
    • Food Science and Preservation
    • /
    • v.30 no.1
    • /
    • pp.28-41
    • /
    • 2023
  • Non-aflatoxigenic Aspergillus oryzae and aflatoxigenic A. flavus cannot be clearly identified by partial sequencing of the internal transcribed spacer (ITS) and 18S ribosomal ribonucleic acid (18S rRNA) regions. This study aimed to compare the accuracy among three aflatoxin detection methods using ultra-performance liquid chromatography (UPLC), high-performance liquid chromatography (HPLC), and an enzyme-linked immunosorbent assay (ELISA) kit and to select the non-aflatoxigenic Aspergillus sp. isolated from soybean paste. All analytical methods were suitable according to the international standards of Codex Alimentarius FAO-WHO (CODEX) or the Ministry of Food and Drug Safety (MFDS). UPLC exhibited the best of limit of detection (LOD) and limit of quantification (LOQ). Based on UPLC, HPLC, and the ELISA kit assay, the P5 and P7 strains isolated from soybean paste had 1,663.49, 1,468.12, and >20 ㎍/kg and 1,470.08, 1,056.73, and >20 ㎍/kg, respectively, detected and re-identified as A. flavus. In contrast, the P3 and P4 strains (A. oryzae), which were detected below the MFDS standards in all assays, were confirmed as non-aflatoxigenic fungi. Among the methods evaluated for quantitative analysis of aflatoxin, UPLC and HPLC are superior in terms of accuracy, and the ELISA kit rapidly detects low concentrations of aflatoxin. Furthermore, this study demonstrates that any Aspergillus sp. isolated for use as a fermentation starter should be analyzed for potential aflatoxin production using UPLC and HPLC for accurate quantitative analysis or ELISA for the rapid detection of low-level concentrations of aflatoxin.

Development of Tumor Screening ELISA kit by Using Novel Tumor Antigen, CM1 (새로운 종양항원인 CM1을 이용한 종양 진단 ELISA kit의 개발)

  • Kang, Jae-Seung;Kim, Dae-Jin;Kim, Young-In;Chang, Ka-Young;Lee, Wang-Jae
    • IMMUNE NETWORK
    • /
    • v.5 no.2
    • /
    • pp.124-129
    • /
    • 2005
  • Background: CM1 (centrocyte/-blast marker 1) is originally defined as a germinal center B cell marker. It is known that CM1 plays a critical role on B cell development in germinal center. In addition, we have found that CM1 is expressed on lymphoma cell lines, such as Raji, Ramos and IM-9. This means that CM1 might be served as a tumor marker as well. In the present study, we examined the expression of CM1 on the surface of the other tumors and the possibility of the development of tumor screening ELISA kit by using CM1. Methods: First, we have examined the expression of CM1 on stomach cancer and hepatoma, which are predominantly (discovered) occurred in Korean, by flow cytometry analysis. After purifying of CM1 antigen from Raji and Ramos, the optimal ELISA condition was determined. And then we compared the level of CM1 between normal individuals and cancer patients by ELISA. To decrease the non-specific binding of anti-CM1 mAb with serum components except CM1 and to enhance the diagnostic accuracy, albumin depletion spin column was used. Results: CM1 was highly expressed on stomach cancer and hepatoma cell lines. In addition, we have also confirmed the increased CM1 expression on cancer patients. The difference of CM1 expression between normal individuals and cancer patients were more clearly observed, after deletion of serum albumin by using albumin depletion spin column. Conclusion: Based on the results from this study, CM1 might be a useful molecule for the early diagnosis of cancer. In addition, further studies for the increase of ELISA sensitivity and appropriate albumin depletion methods should be needed.

Changes of maternal antibodies in broilers vaccinated with infectious bronchitis, infectious bursal disease and Newcastle disease viruses detected by ELISA (육계에서 전염성기관지염, 전염성 F 낭병, 뉴캣슬병 백신투여에 따른 혈중항체가의 변동)

  • 고원석;백귀정;이정원;서이원;김태중;송희종;오언평
    • Korean Journal of Veterinary Service
    • /
    • v.21 no.3
    • /
    • pp.277-284
    • /
    • 1998
  • Serum samples were collected from 100 breeders and their progeny 600 broilers. The breeders and broilers were vaccinated against infectious bronchitis(IB), infectious bursal disease(IBD) and Newcastle disease(ND) viruses according to general vaccination program. The antibodies in serum samples against IB, IBD and ND viruses were detected by ELISA using commercial ELISA kit. Geometric mean titer(GMT) of ELISA was monitored from 1-day-old to 35-day-old broilers and compared to that of breeder chickens. The GMT of ELISA to IB, IBD and ND was declined half level of the day old broiler's antibody titers at about 4, 9 and 4 days of age. The GMT of ELISA to IB, IBD and ND was declined than that of protective antibody titer at about 12, 11, and 15 days of age. Thereafter, the GMT of ELISA to IB, ND were declined and disappeared according to age of broilers. The GMT of ELISA to IBD was declined according to age of broilers, but at 25 days of age increased and 31 days of age increased than that of protective antibody titer. Taken together, these studies led to conclusion that time-course of antibody titers of broilers from vaccinated breeders and that of progeny broliers which vaccinated according to vaccine program. Those are very important data to design vaccine program to breeders and broilers.

  • PDF

A Study on Serum Leptin Values by Elisa Method in Children (ELISA법으로 측정한 소아 혈중 LEPTIN 치에 관한 연구)

  • Song, Soo-Ho;Chung, Young-Hun
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.3 no.2
    • /
    • pp.175-180
    • /
    • 2000
  • Purpose: Leptin is an adipocyte-derived blood-borne satiety factor that acts on its cognate leptin receptor in the hypothalamus, thereby regulating food intake and energy expenditure. We measured the leptin concentrations in serum of normal and obese children with human leptin ELISA kit, unlike previous study with leptin RIA kit and investigated the relationship between leptin concentrations and body mass index, gender, and age. Methods: We measured serum concentrations of leptin in 67 children who were visited to the Department of Pediatrics, Chungnam National University Hospital during the period of 5 months from February, 1999 to June, 1999. Height, weight, obesity index, and body mass index were measured in 67 subjects. Leptin values in serum were measured by sandwich ELISA method. Data analysis was done according to the obesity, body mass index, gender and age. Results: The mean concentration of leptin was $7.69{\pm}8.83\;ng/ml$ in normal children group and $36.34{\pm}18.57\;ng/ml$ in obese group. Serum leptin concentrations were significant correlation with the body mass index (p<0.01). Serum leptin concentration was significant higher in the group of over 10 years of age (p<0.01). Leptin levels showed no significant difference by gender. Conclusion: Serum leptin levels were significantly higher in obesity group than in control one, and they were correlated with body mass index and age. Measurements of leptin value by sandwich ELISA method are very useful and easily applicable to determine obesity.

  • PDF

Evaluation of ST2 and NT-proBNP as cardiac biomarkers in dogs with heartworm disease

  • Lee, Kiho;Park, Jun-Seok;Seo, Kyoung-Won;Song, Kun-Ho
    • Korean Journal of Veterinary Service
    • /
    • v.41 no.2
    • /
    • pp.79-83
    • /
    • 2018
  • This study compared serum concentrations of suppression of tumorigenicity 2 (ST2) and N-terminal pro-B-type natriuretic peptide (NT-proBNP) between healthy and heartworm- infected dogs. Eighteen heartworm-infected dogs and five healthy dogs were included in the study. Dogs were diagnosed and categorized by history, clinical signs, and blood assay, thoracic radiography, echocardiography, and commercial ELISA kit results. Serum samples were sent to the IDEXX reference laboratory for NT-proBNP measurement. ST2 was examined by using a canine interleukin 33 receptor ELISA kit with the quantitative sandwich ELISA method. The severely infected group showed significant elevation of NT-proBNP concentration over those of the control (P=0.03) and mildly infected (P=0.04) group. There were no significant difference in ST2 concentrations among the three groups. The usefulness of NT-proBNP as a cardiac biomarker in dogs with severe heartworm disease was confirmed by the results of this study. Further investigations to assess ST2 as a cardiac biomarker are warranted.

Performance comparison and evaluation of interferon-gamma assay kit for bovine tuberculosis diagnosis (소 결핵 진단을 위한 인터페론감마 검사 키트의 성능 비교 평가)

  • Hong, Leegon;Choi, Woojae;Ro, Younghye;Ahn, Sunmin;Kim, Eunkyung;Choe, Eunhee;Kim, Danil
    • Korean Journal of Veterinary Service
    • /
    • v.43 no.4
    • /
    • pp.201-209
    • /
    • 2020
  • In Korea, bovine tuberculosis (bTB) is a representative zoonotic disease that causes considerable economic loss. In determining the positive bTB, the ELISA method for examining the amount of interferon-gamma (IFN-γ) is included in Korea's diagnostic standard method. Recently, commercially available BIONOTE TB-Feron ELISA Plus (TB-Feron Plus) that detects IFN-γ has been introduced. However, since the scientific basis for the performance is limited, we evaluated performance by comparing it with the results of another IFN-γ ELISA assay kit (BOVIGAM®) certified by Office International des Epizooties. In our research, 42 positive blood samples preliminarily tested with a tuberculin skin test and/or BOVIGAM® and 54 negative blood samples collected from three bTB free farms were subjected to IFN-γ assay using the TB-Feron Plus and the BOVIGAM®, respectively. The result shows that the sensitivity, specificity and accuracy were 81.0% (34/42), 100% (54/54), 91.7% (88/96) in TB-Feron Plus kit and 78.6% (33/42), 100% (54/54), 90.6% (87/96) in BOVIGAM® kit, respectively. Moreover, the overall accordance percentage of the two kits was 99.0% (95/96) and there was almost perfect agreement between two assays (Kappa=0.977, P<0.0001). Furthermore, additional studies confirmed that elevated lymphocyte numbers in blood did not interfere with the results of the TB-Feron Plus kit. And, delayed time from sampling to culture decreased the optical density (OD) value. Therefore, we concluded that the TB-Feron Plus kit was not inferior to BOVIGAM® in performance. High lymphocyte numbers in blood did not impact on TB-Feron Plus results, while delayed time before culture interfered with OD value.

Diagnosis of swine sarcoptic mange(Sarcoptes scabiei var. suis) by ELISA (ELISA를 이용한 돼지 옴 (Sarcoptes scabiei var. suis) 감염증의 진단)

  • Jee, Cha-Ho;Lee, Sam-sun;Chang, Lai-hun
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.4
    • /
    • pp.565-570
    • /
    • 2001
  • The diagnosis of swine sarcoptic mange (Sarcoptes scabiei var. suis) was investigated by ELISA in order to replace current diagnostic methods such as skin scraping, scratching index, or lesion score of dermatitis. The current methods need many efforts and much times and cost much. They can not handle many samples simultaneously. Therefore, in this research we developed ELISA that can handle many samples at a time. The antigens of swine sarcoptic mite were isolated and examined by 12.5% SDS-PAGE and silver staining. The antigenicity of antigen was confirmed by Western blotting using the swine from the artificailly-infested swine with swine sarcoptic mite. The optical density (OD) values of the artificailly-infested positive sera and the naturally-infested positive sera of sows were measured and read in order to confirm the stability of antigens, the reproducibility and validity (sensitivity and specificity) of the manufactured ELISA of swine sarcoptic antigens. In above results, the developed ELISA would be possible to use the diagnostic tool of sarcoptic mange if OD values of piglets, fattening pigs and sows are interpreted reasonably and classified as mange-free and infested.

  • PDF