• Title/Summary/Keyword: EHP-5

Search Result 19, Processing Time 0.025 seconds

Comparison Study of Air-conditioning Systems using LCC Analysis (LCC를 이용한 공조 방식별 비교 연구)

  • Kim, Joung-Kuk;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.3
    • /
    • pp.12-18
    • /
    • 2012
  • The purpose of this study is to make an economic analysis(Life cycle cost) of selecting optimal air conditioning system for a research building which is 8 stories with a total floor area of $32,010m^2$. Energy consumptions of three proposed air-conditioning systems(Alt-1,2,3) that reflect the government green-growth policy are calculated and compared. The results show that life cycle cost of Alt-3(Ventilation DX AHU+EHP) is less than Alt-1(EHP+ventilation DX AHU) by 5.1%, and Alt-2(Absorption chiller/heater+EHP) by 34.3%. Annual energy consumption of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 37.4%. Annual $CO_2$ emission of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 0.2%.

Development of a Simultaneous PCR Assay for Acute Hepatopancreatic Necrosis Disease (AHPND) and Enterocytozoon hepatopenaei (EHP) in Penaeus vannamei (흰다리새우(Penaeus vannamei)에서 급성간췌장괴사병(Acute Hepatopancreatic Necrosis Disease)과 새우미포자충(Enterocytozoon hepatopenaei)의 PCR 동시 진단법 개발)

  • Jeon, Hye Jin;Lee, Chorong;Kim, Bum Keun;Kim, Sumi;Jang, Gwang Il;Rhee, Gahngyoon;Kwon, Hyemin;Han, Jee Eun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.5
    • /
    • pp.691-697
    • /
    • 2021
  • Vibrio parahaemolyticus associated with acute hepatopancreatic necrosis disease (VpAHPND) and Enterocytozoon hepatopenaei (EHP) are the two most important pathogens in shrimp aquaculture and they have caused enormous losses to the shrimp industry worldwide. In ponds, the major target organ for the two pathogens is the hepatopancreas, and infection with EHP is a known potential risk factor for VpAHPND infection. This study aimed to develop a PCR (polymerase chain reaction)-based diagnostic method for simultaneously detecting VpAHPND and EHP. The newly developed PCR diagnostic method could be used to test various samples, such as seawater, shrimp, and feces. The diagnostic method exhibited high sensitivity and specificity for both pathogens. This will help reduce the potential economic losses that may have been caused by the two major shrimp pathogens, VpAHPND and EHP, and will allow for the efforts and time spent combatting them to be dedicated elsewhere.

A Study on the Optimization of Heating and Cooling System in University Campus (대학 캠퍼스 냉·난방시스템 최적화 방안 연구)

  • Park, So-Yeon;Park, Hyo-Soon;Lee, Sang-Hyeok;Kim, Ji-Yeon;Hong, Sung-Hee
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.139-144
    • /
    • 2010
  • The demands are increasing for the efficient heating and cooling system and thermal comfort environment because of changes in climate and environment, and deterioration of buildings and facilities can cause education budget to increase. So the study to apply heating and cooling system to university is urgently needed to improve an optimum energy saving system, educational environment and convenience of maintenance. For this reason, we selected a university campus in Seoul then came to understand the current situation and found some problems. We drew alternatives from comparative analysis of them. It selects representative building and carries out economic analysis to evaluate characteristics of energy consumption and economics on each type of heating and cooling system. As a result we drew the optimum system from those processes as previously stated. We studied 3 available systems, absorption chiller, EHP(Electric Heat Pump) and GHP(Gas Engine Heat Pump). According to LCC analysis suppose that the value of EHP is 1, it came out that the value of absorption chiller is 1.5 and the value of GHP is 2.2. This study, suggesting the optimum heating and cooling system, will support educational and research activities furthermore effect to maximize energy efficiency. Ultimately it is expected that it will contribute to make eco-friendly Green Campus.

A Case Report of Endometriosis Patient: Evaluated by Total Symptom Distress and Short-From Endometriosis Health Profile Questionnaire (자궁내막증으로 인한 골반통과 기타 동반 증상에 대해 증상 스트레스 도구와 삶의 질 측정도구로 평가한 調經種玉湯 加味方 치험례)

  • Kim, Se-Hwa;Hwang, Deok-Sang;Lee, Jin-Moo;Lee, Kyung-Sub;Lee, Chang-Hoon;Jang, Jun-Bock
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.4
    • /
    • pp.106-117
    • /
    • 2015
  • Objectives : This study is to report the clinical effect of oriental medicine on a patient suffering from endometriosis with chronic pelvic pain and other accompanied various symptoms. Methods : The 32 years old patient had suffered from endometriosis symptoms including pelvic pain, menstrual cramping, disuresia, and other pains over 8 years. The patient received herbal medication, acupuncture, abdominal moxibustion during 5 months of outpatient treatment. The clinical effects were evaluated through TSD (Total Symptom Distress) and EHP-5 (Short-From Endometriosis Health Profile Questionnaire). Results : The various clinical symptoms were improved during the treatment. The TSD and EHP-5 score also noticeably reduced. Conclusions : This case study showed that oriental medicine, acupuncture and moxibustion treatment appeared to effectively reduce various symptom of endometriosis.

The investigation of forming the n+ emitter layer for crystalline silicon solar cells (결정질 실리콘 태양전지의 n+ emitter층 형성에 관한 특성연구)

  • Kwon, Hyuk-Yong;Lee, Jae-Doo;Kim, Min-Jung;Lee, Soo-Hong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.233-233
    • /
    • 2010
  • It is important to form the n+ emitter layer for generating electric potential collecting EHP(Electron-Hole Pair). In this paper the formation on the n+ emitter layer of silicon wafer has been made with respect to uniformity of shallow diffusion from a liquid source. The starting material was crystalline silicon wafers of resistivity $0.5{\sim}3\{Omega}{\cdot}cm$, p-type, thickness $200{\mu}m$, direction[100]. The formation of n+ emitter layer from the liquid $POCl_3$ source was carried out for $890^{\circ}C$ in an ambient of $N_2:O_2$::10:1 by volume. And than each conditions are pre-deposition and drive-in time. It has been made uniformity of at least. so, the average of sheet resistance was about 0.12%. In this study, sheet resistance was measured by 4-point prove.

  • PDF

A Study on a position detection of radiation using CCD camera (영상센서를 이용한 방사선원 위치탐지 연구)

  • Lee, Nam-Ho;Choi, Chang-Whan;Shin, Ho-Chul;Jun, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.324-326
    • /
    • 2006
  • CCD형 영상소자는 방사선 피폭 시 표면과 격자내부에 모두 손상을 받게 되며, 감마방사선이나 X선과 같은 고에너지의 이온화 방사선에 노출될 경우 격자 실리콘 내부에 전자-전공쌍(Electron-hole pair, EHP)이 발생된다. 이러한 EHP는 CCD의 순간 출력 광전류로 변환되어 백색 화소 형태의 영상잡음으로 가시화되며, 이 화소 수는 피폭 방사선량에 비례하여 증가하는 특성을 지니고 있다. 따라서 출력 영상정보를 분석하면 조사된 방사선의 양과 특성을 측정할 수 있다. 본 연구에서는 CCD를 이용하여 가상의 방사능 물질 누출 공간에서 방사선원의 방향과 거리정보를 고속으로 탐지하기 위한 장치와 고속 측정 알고리즘을 구현하고 실제 방사선장에서 실증시험을 수행하였다. 방사선 탐지기는 콘형 납 콜리메이터(Collimator)와 가시광 변환용 신틸레이터(CsITl) 및 차폐체로 구성된 센서부와 제어 및 방사광 신호처리를 수행하는 PC부로 구성된다. 감마방사선($^{60}Co$) 방사선장 실증시험에서 방사선원간 거리 83cm에서 측정된 거리 탐지는 5.3%의 오차로 확인되었다. 이 방사선 탐지기는 임의의 고방사선 누출사고에 대한 초기대응 작업을 수행하기 위한 무인 이동로봇용 방사선 탐지기로 활용이 가능하다.

  • PDF

Separation of High Purity Terbium Using Extraction Chromatography (추출 크로마토그래피를 이용한 고순도 테르븀의 분리)

  • Lee, Kwang-Pill;Park, Myoung-Jin;Park, Keung-Shik;Lee, Hueng-Lark;Piao, Zhexiu
    • Analytical Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.370-374
    • /
    • 1999
  • Extraction chromatography was used to scarch optimum separation conditions of terbium. Stationary phase was 2-ethylhexyl-2-ethylhexyl phosphonic acid(HEH[EHP])levextrel (-100~+150 mesh), column size was ${\Phi}20{\times}530mm$ and kept constantly temperature at $50^{\circ}C$, adsorption flow rate of $0.2mL/cm^2{\cdot}min$, elution flow rate of $1.0mL/cm^2{\cdot}min$, column diameter to packing height of 1:15. But to search optimum separation conditions of terbium, it changed the eluent acidity, the loading weight of sample. the composition of sample. In conclusion, acidity was 0.6 N HCl, loading weight of sample was about 5% and composition of sample was $Gd_2O_3(20%)+Tb_4O_7(60%)+Dy_2O_3(20%)$. Moreover purity of separated terbium by ICP-AES analysis was 99.98% in yield of 99.99%.

  • PDF

Power-Dependent Characteristics of $n^+$-p and $p^+$-n GaAs Solar Cells

  • Kim, Seong-Jun;Kim, Yeong-Ho;No, Sam-Gyu;Kim, Jun-O;Lee, Sang-Jun;Kim, Jong-Su;Lee, Gyu-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.236-236
    • /
    • 2010
  • 단일접합 $n^+-p/p^+$ (p-emitter) 및 $p^+-n/n^+$ (n-emitter) GaAs 태양전지 (Solar Cell)를 각각 제작하여, 그 소자특성을 비교 분석하였다. AM 1.5 (1 sun, $100\;mW/cm^2$) 표준광을 조사할 경우, p-emitter/n-emitter 소자의 개방회로전압 (Voc), 단락회로전류 (Jsc), 충전율 (FF), 효율 (Eff)은 각각 0.910/0.917 V, $15.9/16.1\;mA/cm^2$, 78.7/78.9, 11.4/12.1%로서, n-emitter 소자가 다소 크지만 거의 비슷한 값을 가지고 있었다. 태양전지의 집광 특성을 분석하기 위하여 조사광의 출력에 따른 태양전지의 소자 특성을 측정하였다. 조사광 강도가 높아짐에 따라 p-emitter 소자의 특성은 점진적으로 증가하는 반면, n-emitter는 1.3 sun에서 약 1.4 배의 최대 효율 (17%)을 나타내고 조사광이 더 증가함에 따라 급격히 감소하는 특성을 보여 주었다. (그림 참고) 본 연구에서 사용한 2종류 소자의 층구조는 서로 반대되는 대칭구조로서, 모두 가까이에 위치하고 있는 표면전극 (surface finger) 방향으로 소수전하 (minority carrier)가 이동하고 다수전하 (majority carrier)는 기판 (두께 $350\;{\mu}m$)을 통한 먼 거리의 후면전극 (back electrode)으로 표류 (drift)되도록 설계되어 있다. 이때, n-emitter에서는 이동도 (mobility)와 확산길이 (diffusion length)가 높은 전자가 후면전극으로 이동하기 때문에 적정밀도의 전자-정공 쌍 (EHP)이 여기될 경우에는 Jsc와 Eff가 극대화되지만, 조사광 강도 또는 EHP가 더 높아질 경우에는 직렬저항의 증가와 함께 전류-전압 (I-V)의 이상인자 (ideality factor)가 커짐으로서 FF와 효율이 급격히 감소한 결과로 분석된다. 현재 전산모사를 통한 자세한 분석을 진행하고 있으며, 본 결과는 효율 극대화를 위한 최적 층구조 및 도핑 밀도 설계에 활용할 수 있을 것으로 판단된다.

  • PDF

Analysis of Electric Substitution Effects by the Gas Consumption and Characteristics of Gas Cooling System (냉방기기 사용량과 특성을 고려한 가스냉방기기의 전력대체 효과 분석)

  • Park, Rae-Jun;Song, Kyung-Bin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.669-675
    • /
    • 2012
  • Recently, the amount of electrical heat pump(EHP), a electrical conditioning equipment, is sharply increasing due to the luxury and multi-story trend of building. Accordingly, the cooling load that occupying substantial part of summer electric consumption has increased dramatically, making difficulties in domestic supply of electricity in summer. There are some efforts to replace it with an alternative cooling equipment such as gas heat pump(GHP), a gas cooling equipment, in order to solve the problem of summer electricity supply through reducing the summer electricity peak. It is rare, however, to find studies on the actual effects of GHP on the reduction of summer electricity peak. This study, therefore, estimated the effects of the GHP on the summer electricity peak by the gas consumption and characteristics of gas cooling systems. In addition, electric substitution effects by gas cooling systems were analyzed through case studies in the summer of 2010.

Performance Evaluation of Air Source Multi Heat Pump Floor Heating System in Apartment (공동주택 공기열 멀티 히트펌프의 바닥난방 성능 평가)

  • LEE, C.H.;Nah, H.S.;JUNG, H.;Kim, K.S.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.93-98
    • /
    • 2011
  • To analyze and evaluate the performance of developing air to water multi heat pump, the heat pump was installed and tested at low energy house in Daejeon, korea. Heating capacity of heat pump is 16.5KW and cooling capacity is 14.0KW. Space heating/cooling, floor heating and hot water is available. The results performance evaluation of heat pump in lab test showed that the coefficient of performance (cop) was 3.75, and heating capacity was 16.0KW in ambient temperature $7^{\circ}C$. Also at ambient temperature $-15^{\circ}C$, the COP was 1.69. At a low energy house, floor heating is controled by a floor heating water temperature and a room temperature. The COP of heat pump is decreased with frequent on/off operation for controlling of floor heating water temperature.