• Title/Summary/Keyword: EHP

Search Result 86, Processing Time 0.024 seconds

A Study on the EHP Estimation and Design Procedure of Small Fishing Boat's Hull Form (소형어선(小型漁船)의 유효마력추정(有效馬力推定) 및 선형설계법(船型設計法))

  • Young-Gill,Lee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.21 no.3
    • /
    • pp.1-10
    • /
    • 1984
  • The computer programs of effective horsepower estimation of small fishing boat were developed, which was based on the statistical analysis of model test results. From the EHP estimation by these program and experimental model tests of practical fishing boats, the estimation accuracy was verified with maximum deviation of about 10 percent. Also, the EHP estimation accuracy was practically applied to initial design of four small fishing boats, and after the tank tests, the EHP reduction of the order of 15 to 25 percent was confirmed, as compared with existing ships. Moreover, a computer aided design procedure of fishing boat's hull form has been proposed in this study. The practical use of this procedure of fishing boat's hull form has been proposed in this study. The practical use of this procedure was demonstrated with the hull form design results of several fishing boats.

  • PDF

A Study on the Estimation Method of EHP of Fishing Boats Use Statistical Regression Analysis (통계적 회귀계수를 이용한 어선의 유효 마력 추정법에 관한 연구)

  • Lee, Guen-Moo;Park, Jai-Woung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.2
    • /
    • pp.199-209
    • /
    • 1995
  • From the results of model tests, statistical regression analysis of EHP estimation based on hull form parameters is adopted in this study. From this result, the method for estimation of EHP at the initial design stage of fishing boats is developed. This method is applied to four standard fishing boats with chine lines and two standard fishing boats with round bottom. The EHP's are estimated and compared to experimental results. In the case of six fishing boats, the estimated EHP corresponds well and approximates well with experimental results through out all the range tested. From these results it can be concluded that this numerical method is very efficient in estimating EHP of fishing boats having chine line and round bottom. Therefore, by applying the proposed method to design of fishing boats, we can improve the resistance characteristics. Further, this method can contribute to reduction of design time and thus down the total expenses.

  • PDF

A Study on the Energy Consumption of Elementary Schools in Daejeon Metropolitan City (대전광역시 초등학교의 에너지 사용에 관한 조사연구)

  • Lee, Sang Hyeok;Park, Seung Ik
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.1
    • /
    • pp.8-15
    • /
    • 2018
  • The purpose of this study was to analyze the energy consumption according to the HVAC systems in 122 elementary schools. To do this, we classified schools according to the HVAC systems. Selected schools were classified to the following groups by the HVAC equipments: EHP, EHP and GHP together and GHP. In addition we divided schools by the number of classes. The main results are as follow: 1) Annual average energy consumption at schools was about 300~900(kWh/students), $30{\sim}50(kWh/m^2)$, 9,000~29,000((kWh/class) 2) The smaller schools, the higher the energy consumption per class; energy usage of 10~19 classes's schools were approximately 3 times higher than 40 classes's schools. 3) Schools where the EHP was installed had the lowest energy costs and energy usage. The difference in energy costs was lower than the difference in energy usage because of the fuel price and the ratio of energy sources.

Comparison Study of Air-conditioning Systems using LCC Analysis (LCC를 이용한 공조 방식별 비교 연구)

  • Kim, Joung-Kuk;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.3
    • /
    • pp.12-18
    • /
    • 2012
  • The purpose of this study is to make an economic analysis(Life cycle cost) of selecting optimal air conditioning system for a research building which is 8 stories with a total floor area of $32,010m^2$. Energy consumptions of three proposed air-conditioning systems(Alt-1,2,3) that reflect the government green-growth policy are calculated and compared. The results show that life cycle cost of Alt-3(Ventilation DX AHU+EHP) is less than Alt-1(EHP+ventilation DX AHU) by 5.1%, and Alt-2(Absorption chiller/heater+EHP) by 34.3%. Annual energy consumption of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 37.4%. Annual $CO_2$ emission of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 0.2%.

Energy Saving System of EHP Control at the College Lecture Room (대학교 강의실 EHP 제어를 이용한 에너지 절약 시스템)

  • Jeong, Kybum
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.167-174
    • /
    • 2014
  • Heating and air conditioning system is changing rapidly from the traditional HVAC central supply system to the individual supply system with electrical heat pump system (EHP) in Korean school buildings. The individual supply system has advantages to turn on and off individually and to adjust the thermal comfort separately, but energy is wasted in the unoccupied classroom when the last leaving occupant does not turn off the controller. If the controller is to be off automatically while the classroom is not in use, energy consumption would decrease dramatically. This project aims to cease the unnecessary EHP supply in vacant classroom by inputting the class schedule from the central control room to reduce the energy-spending. Experimental measurements were carried out between the controlled classroom that is turned off when not in use and the uncontrolled room that is turned on continually. Occupant's comfort and energy consumption were measured and compared between the controlled case and the uncontrolled case. The energy consumption of controlled classroom case is 30-60% less than that of the uncontrolled classroom case. This result shows that controlling the cooling supply for the unoccupied classroom using the class schedule can decrease the energy consumption remarkably. This supply control system can be used to conserve energy in school structures like universities.

Economic Investigation of Small Scale Cogeneration System in a School Dormitory of Busan Region (부산지역 학교 기숙사에서의 소형열병합발전 시스템의 경제성 분석)

  • Song, Jae-Do;Ku, Bon-Cheol;Kang, Yul-Ho;Park, Jong-Kyu;Lee, Jae-Keun;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.9
    • /
    • pp.657-662
    • /
    • 2012
  • The cogeneration system can operate at efficiencies greater than those achieved when heat and power are produced in separate. The optimal system can be determined by selecting the auxiliary system combined with cogeneration system. In the present study, economic investigation has been conducted with the cogeneration electric heat pump(EHP) system and the cogeneration absorption chiller(AC) system to install in a school dormitory. To analyze life cycle cost(LCC), cost items such as initial investment costs, annual energy costs and maintenance costs of each system have been considered. The initial investment cost is referred to the basis of estimated costs, and annual energy costs such as the electric power and gas consumption are based on the data in a school dormitory. LCC is evaluated with the present worth method. Considering investigated results, the initial investment cost of the cogeneration EHP system is more profitable about 24% than that of the cogeneration AC system. The energy cost of the cogeneration EHP system is more profitable about 8% than the cogeneration AC system. The LCC shows that the cogeneration EHP system is the most effective system in the school dormitory.

Development of a Simultaneous PCR Assay for Acute Hepatopancreatic Necrosis Disease (AHPND) and Enterocytozoon hepatopenaei (EHP) in Penaeus vannamei (흰다리새우(Penaeus vannamei)에서 급성간췌장괴사병(Acute Hepatopancreatic Necrosis Disease)과 새우미포자충(Enterocytozoon hepatopenaei)의 PCR 동시 진단법 개발)

  • Jeon, Hye Jin;Lee, Chorong;Kim, Bum Keun;Kim, Sumi;Jang, Gwang Il;Rhee, Gahngyoon;Kwon, Hyemin;Han, Jee Eun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.5
    • /
    • pp.691-697
    • /
    • 2021
  • Vibrio parahaemolyticus associated with acute hepatopancreatic necrosis disease (VpAHPND) and Enterocytozoon hepatopenaei (EHP) are the two most important pathogens in shrimp aquaculture and they have caused enormous losses to the shrimp industry worldwide. In ponds, the major target organ for the two pathogens is the hepatopancreas, and infection with EHP is a known potential risk factor for VpAHPND infection. This study aimed to develop a PCR (polymerase chain reaction)-based diagnostic method for simultaneously detecting VpAHPND and EHP. The newly developed PCR diagnostic method could be used to test various samples, such as seawater, shrimp, and feces. The diagnostic method exhibited high sensitivity and specificity for both pathogens. This will help reduce the potential economic losses that may have been caused by the two major shrimp pathogens, VpAHPND and EHP, and will allow for the efforts and time spent combatting them to be dedicated elsewhere.

A study for a Performance analysis of Hybrid heat pump Air conditioning system (복합열원형 히트펌프 냉난방 시스템의 성능분석에 관한 연구)

  • Lim, Hyun-Mook;Park, Hee-Moon;Cho, Soo;Sung, Uk-Joo;Park, Jin-Hoon;Park, Tae-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1373-1378
    • /
    • 2009
  • This study is aiming comparison and analization between efficiency of hybride air conditioning system which uses low temperature water under dam and air and EHP(Electric Heat Pump). The experimental was carried out with air cooling tests for EHP system having 80HP and composition heat pump system. P-i diagram of both systems and COP was used to derive schemetic and calcuations. As results of the tests, hybride system has 1.4 time higher efficiency coefficient.

  • PDF

Economic Evaluation of Various Cooling Systems (냉방기기별 경제성 평가)

  • Kim, Young-Il;Cho, Keum-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.214-219
    • /
    • 2008
  • In this study, medium capacity EHP and GHP for air-conditioning a building with a floor area of $1,200\;m^2$ are compared economically. To consider all the factors of initial and operation costs effectively, an annual equal payment method is proposed. For the initial cost, equipment, construction, installation, electric facility, financial subsidy and tax cut are considered. Basic electricity, energy(electricity and gas), space charge, labor, insurance and repair are considered for the operation cost. Under the assumptions made in this study, overall cost of EHP is less than that of GHP. However, different outcome may result if different assumptions are made. This study is useful for performing an economic evaluation of various air-conditioning systems.

  • PDF