Fabrication of EEG Measuring System with High Precision Characteristics (고정밀도의 뇌파측정시스템 개발 연구)

  • 도영수;장호경;한병국
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.156-162
    • /
    • 2002
  • In this study, we attempted in preparing high precision EEG measuring equipment. To measure EEG in high efficiency, pre-amplifier should get high performance common mode rejection ratio. Also, separation amplifier is essential to eliminate common line noise. So, our study were pointed at elevating the efficiency of eliminating noise, user safety and low noise characteristics. Prepared high precision pre-amplifier for EEG was A/D converted to automatically classify $\alpha$ wave, $\beta$ wave and $\theta$ wave. And converted data were Fast Fourier Transformed with real time DSP (Digital Signal Processing). Clinical demonstrations were carried out with healthy students, aged between 20 to 26 who has no histories of illness. To recognize the efficiency of the EEG, prepared EEG were used with MS equipment in low stimulated state and high stimulated state. Then, we studied at the effect of sensitivity on brain wave. From this study, it is known that our EEG equipment is efficient in sensitivity evaluation and suitable stimulations for each psychological state are required.

  • PDF

A Study on the Correlation Analysis of EEG and Vibraimage due to Auditory and Olfactory Stimulation (청각 및 후각자극에 의한 뇌파(EEG)와 진동이미지기술의 상관성 분석에 관한 연구)

  • Kim, Jung-Min;Kim, Myung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4291-4297
    • /
    • 2015
  • EEG has been used to measure the emotion of amenity and discomfort in the interior space. EEG is limited to the experiment, because it is a equipment of contact type. However, Vibraimage can measure the emotion with a web camera. Because Vibraimage is a equipment of non-contact type, it is more suitable for the interior space than EEG. Therefor, it tries to find a correlation variable between EEG and Vibraimage to measure the human emotions. In this study, it were analyzed correlation of EEG and vibraimage due to variation of loudness 60[dB], 90[dB] and rosemary, jasmine scents. Check the health status of subjects who were selected 3 male students, and the period of this experiment was about months. The condition of the environmental test room was in temperature 25[$^{\circ}C$], relative humidity 50[RH%], air current speed 0.02[m/s] and illuminance 1000[lux]. It were analyzed correlation of twenty-three index of EEG(absolute ${\theta}$, relative ${\theta}$, absolute $S{\alpha}$, relative $S{\alpha}$, absolute ${\alpha}$, relative ${\alpha}$, absolute ${\beta}$, relative ${\beta}$, absolute $\gamma$, relative $\gamma$, absolute $F{\alpha}$, relative $F{\alpha}$, absolute SMR, relative SMR, $SMR/{\theta}$, $SMR+M{\beta}/{\theta}$, absolute $H{\beta}$, relative $H{\beta}$, $H{\beta}/{\alpha}$, absolute $M{\beta}$, relative $M{\beta}$, SEF50, ASEF50) and ten index of Vibraimage(Aggression, Stress, Tension/Anxiety, Suspect, Balance, Charm, Energy, Self regulation, Inhibition, Neuroticism). As a result, I was found that relative ${\gamma}$ index of EEG and neuroticism index of Vibraimage have a high correlation as (${\pm}$).414 and (${\pm}$).424.

Fundamental requirements for performing electroencephalography

  • Koo, Dae Lim;Kim, Won-Joo;Lee, Sang-Ahm;Kim, Jae Moon;Kim, Juhan;Park, Soochul;Korean Society of Clinical Neurophysiology Education Committee
    • Annals of Clinical Neurophysiology
    • /
    • v.19 no.2
    • /
    • pp.113-117
    • /
    • 2017
  • The performance of electroencephalogram (EEG) recordings is affected by electrode type, electronic parameters such as filtering, amplification, signal conversion, data storage; and environmental conditions. However, no single method has been identified for optimal EEG recording quality in all situations. Therefore, we aimed to provide general principles for EEG electrode selection as well as electronic noise reduction, and to present comprehensive information regarding the acquisition of satisfactory EEG signals. The standards provided in this document may be regarded as Korean guidelines for the clinical recording of EEG data. The equipment, types and nomenclature of electrodes, and the details for EEG recording are discussed.

EEG Artifact Detection Algorithm Base on Nonlinear Analysis Method (비선형 분석에 의한 뇌파 아티펙트 검출 알고리즘)

  • Kim, Chul-Ki;Park, Jun-Mo;Kim, Nam-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.1
    • /
    • pp.7-12
    • /
    • 2020
  • Various parameters are used to measure anesthetic depth during surgery using brain waves, and in actual clinical use, the linear analysis SEF is widely used. However, with recent studies showing that biological signals including EEG, contain nonlinear properties interest in nonlinear analysis of brain signals is increasing and parameters based on these are being developed. In this study, we are going to develop a parameter that can measure EEG using the nonlinear analysis method and extract noise that can be mixed with external electronic equipment and EEG instrumentation by comparing it with the data from the bispectrum analysis of static waves.

Modeling for Implementation of a BCI System (BCI 시스템 구현을 위한 모델링)

  • Kim, mi-Hye;Song, Young-Jun
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.8
    • /
    • pp.41-49
    • /
    • 2007
  • BCI system integrates control or telecommunication system with generating electric signals in scalp itself after signal acquisition. This system detect a movement of EEG at real time, can control an electron equipment using a generated signal through EEG movement or software-based processor. In this paper, we deal with removing and separating artifacts induceced from measurement when brain-computer interface system that analyzes recognizes EEG signals occurred from various mental states. In this paper, we proposed a method of EEG classification and an artifact interval detection using bisection mathematical modeling in the EEG classification process for BCI system implementation.

A Study on the Multi-sensory Stimulation of Aroma and Color Temperature effects on Neuro-energy (아로마 및 색온도의 다감각자극이 뉴로에너지에 미치는 영향)

  • Kim, Jung-Min;Seo, Kwang-Soo;Kim, Myung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3579-3586
    • /
    • 2015
  • In this study, EEG, HRV, and Vibra image were compared and analyzed in the environmental test room due to stimulation of aroma and color temperature. The condition of the environmental test room was in temperature $25[^{\circ}C]$, relative humidity 50[RH%], air current speed 0.02[m/s] and illuminance 1000[lux] with setting up different sensory stimulation condition which are before exposure, single-sensory stimulation of Jasmine scent, single-sensory stimulation of RED color lighting, and multi-sensory stimulation of Jasmine scent and RED color lighting. The result of this study, at multi-sensory stimulation of Jasmine scent and RED color lighting, relative $S{\alpha}$ wave, SEF50, $SMR/{\theta}$ and SDNN were revitalized, and both sides ${\alpha}$ wave asymmetry index, stress index, fatigue degree, and HRT were decreased. Also, Viba image of tension/anxiety and stress were declined. Therefore multi-sensory stimulation of Jasmine scent and RED color lighting effects to increase the Neuro-energy like amenity, productivity of work efficiency, and concentration.

A Study on Reliability and Applicability of Oriental Medical Music Therapy Using (음악요법의 한의학적 활용을 위한 신뢰도 및 적용 가능성 연구)

  • Song, Min Sun;Choi, Chan Hun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.6
    • /
    • pp.674-682
    • /
    • 2014
  • The purpose of this study was to identify the effect of applying oriental music therapy and reliability of electroencephalogram(EEG) equipment. The study was approved by the critical trial judge committee from ${\bigcirc}{\bigcirc}$(IRB No. 2013-07) university. In order to measure test-retest reliability for 15 subjects, EEG for same participants were measured using same method mentioned above after 2 hours from the first measurement. Same provider implemented to each person at same time. Firstly, EEG was measured for 5 minutes after the subject with attached electrodes sat on chair comfortably for 10 minutes. Then, the subject was given mental stress using the four fundamental arithmetic operations for 5 minutes, and measured EEG for another 5 minutes. After that the subject sat on the chair comfortably listening oriental medicine music therapy for 5 minutes, and EEG was measured for 5 minutes again. There was no side effect regarding music therapy reported. Raw data, which was measured in each step, were converted through FFT(fast fourier transform) and analyzed after divided into certain frequency including ${\alpha}$ wave, ${\beta}$ wave, ${\theta}$ wave, immersion wave, stabilization wave, sef100 wave, and sef95 wave. Data were analyzed using wilcoxon signed rank test, Intraclass correlation coefficient(ICC), repeated measures ANOVA with the SPSS program. In test-retes method, there were significantly differences in ${\alpha}$ wave, ${\beta}$ wave, immersion wave, stability wave, ${\theta}$ wave, sef100 wave, sef95 wave. ICC has shown a high degree of reliability that it was ${\alpha}$ wave .877, ${\beta}$ wave .855, ${\gamma}$ wave .895, immersion wave .897, stability wave .816, ${\theta}$ wave .904, sef100 wave .910, sef95 wave .776. Also, there was a statistically significant difference in ${\alpha}$ wave after applying oriental music therapy. Based on these results, it is considered that average of the channel EEG and application of oriental music therapy would be practiced by increase of sample size using this machine.

Video and Film Rating Algorithm using EEG Response Measurement to Content: Focus on Sexuality

  • Kwon, Mahnwoo
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.7
    • /
    • pp.862-869
    • /
    • 2020
  • This study attempted to analyze human brain responses toward visual content through EEG signals and intended to measure brain wave reactions of different age groups to determine the sexuality level of the media. The experimental stimuli consist of three different video footage (rated ages 12, 15, and 18) to analyze how subjects react in situations where they actually watch sexual content. For measuring and analyzing brain wave reactions, EEG equipment records alpha, beta, and gamma wave responses of the subjects' left and right frontal lobes, temporal lobes, and occipital lobes. The subjects of this study were 28 total and they are divided into two groups. The experiment configures a sexual content classification scale with age or gender as a discriminating variable and brain region-specific response frequencies (left/right, frontal/temporal/occipital, alpha/beta/gamma waves) as independent variables. The experimental results showed the possibility of distinguishing gender and age differences. The apparent differences in brain wave response areas and bands among high school girls, high school boys, and college students are found. Using these brain wave response data, this study explored the potential of developing algorithm for measurement of age-specific responses to sexual content and apply it as a film rating.

Design and Implementation of Optimal LED Emotional-Lighting Control System (최적의 LED 감성조명 제어 시스템 설계 및 구현)

  • Yun, Su-Jeong;Lin, Chi-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.8
    • /
    • pp.1637-1642
    • /
    • 2015
  • Next-generation applications using technology IT fused to biological signals from the emotional state to extract a lot of research has been, and the sensitivity of the human sensory functions influences the physiological condition known to be the fact that. In this paper, Propose an Emotional-lighting control algorithm using bio-signals. LED lighting for Emotion light is environmentally friendly and has a high efficiency and long life. In particular, LED lights are different colors represent the possible single light sphere advantages. And, Human sensitivity for determining a more accurate biological signals using EEG was collected using EEG equipment sensitivity was determined to analyze the EEG.

Arduino-based power control system implemented by the MyndPlay (MyndPlay를 이용한 Arduino기반의 전원제어시스템 구현)

  • Kim, Byeongsu;Kim, Seungjin;Kim, Taehyung;Baek, Dongin;Shin, Jaehwan;An, Jeong-Eun;Jeong, Deok-Gil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.924-926
    • /
    • 2015
  • In this paper, we use the interface, which many countries concentrates research of Brain - Computer Interface with the device and MyndPlay based on the IoT intelligent Arduino. Finally we will make the Brain - Computer Connection environment, the purpose of Brain - Computer Interface. Recognizes the EEG of a person who wearing the equipment, analyze, classify, and we did a research to design an intelligent thing to suit user's condition. In addition, we use the XBee, and Bluetooth to communicate to other devices, such as smart phone. In conclusion, this paper check users current status via brain waves, and it allows to control the power and other objects by using the EEG(Electroencephalography).

  • PDF