• Title/Summary/Keyword: ECO-Glass

Search Result 108, Processing Time 0.035 seconds

Preparation and Dissolution Properties of the Eco-glass Fertilizer containing Trace Elements

  • Lee Hoi Kwan;Hwang Sheng Jean;Kang Won Ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.11a
    • /
    • pp.96-98
    • /
    • 2004
  • At the previous papers, we showed that K2O-CaO-P2O5 glasses had a solubility in air so that they could be used for glass fertilizer. In this work, we fabricated the Eco-glass fertilizer containing trace elements such as B, Mg, Zn, Fe, Cu, Co, and Mo by a melt-quenching process and the dissolution properties of these glasses were investigated with pH meter and ICP analyzer. In case of the glasses containing the trace elements, effect of trace elements on the dissolutions is not obvious and ignorant the stability of mother glass. Also, the dissolution amounts of each trace elements depend on the mother glass composition and the quantity of each trace element, and mother glasses determined the dissolving velocity of chemical elements.

  • PDF

Preparation of Hollow Silica by Spray Drying of Nano Silica Particles and Its Heat Transfer Property (나노 실리카의 분무건조를 이용한 중공구 입자 제조와 실리카중공구의 열전달 특성)

  • Youn, Chan Ki;Lim, Hyung Mi;Cha, Sujin;Kim, Dae Sung;Lee, Seung-Ho
    • Korean Journal of Materials Research
    • /
    • v.22 no.10
    • /
    • pp.531-538
    • /
    • 2012
  • Hollow silica spheres were prepared by spray drying of precursor solution of colloidal silica. The precursor solution is composed of 10-20 nm colloidal silica dispersed in a water or ethanol-water mixture solvent with additives of tris hydroxymethyl aminomethane. The effect of pH and concentrations of the precursor and additives on the formation of hollow sphere particles was studied. The spray drying process parameters of the precursor feeding rate, inlet temperature, and gas flow rate are controlled to produce the hollow spherical silica. The mixed solvent of ethanol and water was preferred because it improved the hollowness of the spheres better than plain water did. It was possible to obtain hollow silica from high concentration of 14.3 wt% silica precursor with pH 3. The thermal conductivity and total solar reflectivity of the hollow silica sample was measured and compared with those values of other commercial insulating fillers of glass beads and $TiO_2$ for applications of insulating paint, in which the glass beads are representative of the low thermal conductive fillers and the $TiO_2$ is representative of infrared reflective fillers. The thermal conductivity of hollow silica was comparable to that of the glass beads and the total solar reflectivity was higher than that of $TiO_2$.

Development of Eco-friendly Lead Substitute Materials (친환경 납추 대체소재 개발)

  • Gwon, Jin Uk;Song, Hee Jin;Hwang, Dae Youn;Kim, Hye Sung
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.3
    • /
    • pp.130-138
    • /
    • 2022
  • In this study, the characteristic of an amorphous fishing weight material according to controlling the alloy type and alloy composition of the glass forming agent added in PbO2 oxide was investigated. According to the experimental, when the glass forming agent of 15wt%SiO2-1wt%MgO content was added in β-PbO2, an amorphous fishing weight substitute having the lowest friction coefficient, excellent corrosion resistance and durability was obtained. The cell number of PbO2-15wt%SiO2-1wt%MgO sample incubated in cell culture fluid tended to hardly decrease even after a lapse of 24 hours, It means that the fabricated PbO2-15wt%SiO2-1wt%MgO sample is significantly less-toxic and harmless to the human body, unlikely to metallic lead. It is considered that an fabricated amorphous fishing weight substitute proved to have a potential as an eco-friendly material with little marine pollution.

A Study on the Natural Energy Effect about the Address No.0 of Eco-friendly Architecture (생태건축 0번지의 자연에너지 효과에 관한 연구)

  • Lee, Si-Woong;Kang, Byung-Ho;Lim, Sang-Hoon;Choi, Seung-Hee
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.19-25
    • /
    • 2003
  • The Address No.0 of Eco-friendly Architecture offers unique experience for those who visit the place to envisage the future architecture where nature, human and building exist in harmony. It is open to the general public including the students of elementary and secondary schools. This house has been built to provide opportunities for the general public to experience eco-friendly architecture. It's floor area is 42 pyung($140m^2$) and the overall site has the area of 180 pyung($600m^2$). The following illustrates some of its prominent features : ${\bullet}$ Remodeling of a traditional Korean residence ${\bullet}$ Application of passive solar systems ${\bullet}$ Use of clerestory windows and daylighting systems(washroom and machine room) ${\bullet}$ Operation of solar water heaters with flat plate collectors ${\bullet}$ Construction of Biotop(small ecological world) ${\bullet}$ Water circulation for Biotop by photovoltaic(150W) and wind power(400W) generation ${\bullet}$ Outdoor hot water supplied by all-glass evacuated solar tubes. Through this Address No.0 of Eco-friendly Architeture conclusions are as followings. 1. The array of tubes in collector has the best nice in that the number of tube is nine and the tilt angle is the latitude $+20^{\circ}$. 2. The thermal performance of the all-glass solar vacuum collector was excellent than of the flate-plate solar collector. 3. The adaption of new small wind power systems to buildings were proved to produce a profit if it is considered the expense of environment improvement and the wind speed increasing according to rise of building hight.

Environmental Assessment of Chemically Strengthened Glass for Touch Screen Panel by Material Life Cycle Assessment (물질전과정평가를 이용한 터치스크린패널용 화학강화유리에 대한 환경성 평가)

  • Lee, Na-Ri;Lee, Soo-Sun;Kim, Kyeong-Il;Hong, Tae-Whan
    • Clean Technology
    • /
    • v.18 no.3
    • /
    • pp.301-306
    • /
    • 2012
  • Rapidly growing mobile machines such as tablet PC and smart phone are equipped with touch screen panel using a sturdy material for products surface protection. Therefore, surge of chemically strengthened glass was increased and the amount of waste matter is proportional to demand. The purpose of this study is environmental impact assessment on touch screen panel of chemically strengthened glass by material life cycle assessment (MLCA). We used CES of Granta, SimaPro and Gabi software for MLCA. Chemically strengthened glass (2.7, 5.7 and 10.3 inch) was calculated to environmental impact assessment by Granta software under two cases. One case is Landfill and the other case is Reuse. As a result, in case of reuse, energy values of 2.7, 5.7 and 10.3 inches were reduced by an average of 51.4%, $CO_2$ values were reduced by an average of 46.6% than Landfill case, respectively. We assessed impact categories of 11 types using SimaPro software. As a result, the contents of fossil fuels, inorganics and climate change have a huge impact than the other impact categories. And the main cause of environmental impact is antimony and hydrogen fluoride in Gabi results.

A Comparative Analysis of Life Cycle Cost on the Window Glass and the Insulation Film Coated Glass for Window (창호 유리의 단열필름 시공에 따른 생애주기비용 비교 분석)

  • Jeong, Mingu;Kim, Gwang-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.6
    • /
    • pp.583-590
    • /
    • 2014
  • The purpose of this study is to analyze and compare the life cycle cost of window glass with insulation film and regular glass, to verify an economical window construction method. As an approach method, the thermal performance data of each type of glass was measured using Window 6.3 and ECO2-OD Simulation Program, applied it to the case building to calculate the air conditioning and heating maintenance costs and LCC, and compared the economic feasibility. As a result, installing an additional insulation film prevents the solar heat penetration in the summer, so it reduces the cooling cost, on the other hand, it increased heating cost in winter. From the life cycle cost perspective, the effect of cooling cost reduction does not counterbalance the increase in heating cost and the additional cost from film installation and repair; therefore, the installation of insulation film may not be a proper method.