ST-Segment Analysis of ECG Using Polynomial Approximation (다항식 근사를 이용한 심전도의 ST-Segment 분석)

  • Jeong, Gu-Young;Yu, Kee-Ho;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.8
    • /
    • pp.691-697
    • /
    • 2002
  • Myocardial ischemia is a disorder of cardiac function caused by insuficient blood flow to the muscle tissue of the heart. We can diagnose myocardial ischemia by observing the change of ST-segment, but this change is temporary. Our primary purpose is to detect the temporary change of the 57-segment automatically In the signal processing, the wavelet transform decomposes the ECG(electrocardiogram) signal into high and low frequency components using wavelet function. Recomposing the high frequency bands including QRS complex, we can detect QRS complex more easily. Amplitude comparison method is adopted to detect QRS complex. Reducing the effect of noise to the minimum, we grouped ECG by 5 data and compared the amplitude of maximum value. To recognize the ECG .signal pattern, we adopted the polynomial approximation partially and statistical method. The polynomial approximation makes possible to compare some ECG signal with different frequency and sampling period. The ECG signal is divided into small parts based on QRS complex, and then, each part is approximated to the polynomials. After removing the distorted ECG by calculating the difference between the orignal ECG and the approximated ECG for polynomial, we compared the approximated ECG pattern with the database, and we detected and classified abnormality of ECG.

Development of ECG Identification System Using the Fuzzy Processor (퍼지 프로세서를 이용한 심전도 판별 시스템 개발)

  • 장원석;이응혁
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.403-414
    • /
    • 1995
  • It is very difficult to quantize the ECG analysis because the decision criterion for ECG is different with each other depending on the medical specialists of the heart and there are measured detecting errors for each ECG measurement system. Therefore, we developed the real-time ECG identification system using digital fuzzy processor for STD-BUS, in order to reduce ambiguity generated in the process of ECG identification and to analyze the irregular ECG stastically to ECG's repetition interval. The variables such as AGE (months), width of QRS, average RRI, and RRI were used to classify the ECG, and were applied to ECG signal indentification system which is developed for the purpose of research. It was found that the automatic diagnosis of ECG signal was possible in the real time process which was impossible in general process of algorithm.

  • PDF

A Wireless ECG Measurement System based on the Zigbee USN (Zigbee USN 기반의 무선 ECG 측정 시스템)

  • Chang, Yun-Seok;Kim, Bo-Yeon
    • The KIPS Transactions:PartC
    • /
    • v.18C no.3
    • /
    • pp.195-198
    • /
    • 2011
  • Recent expansion of the ubiquitous environment and improvement of the USN give lots of U-healthcare systems. In this paper, we design and implement a wireless ECG measurement system that can send ECG signals among the sensors and collector. It can also give almost the same precision as a hospital ECG system with mobility. The most important fact of the mobile ECG system is the signal data connectivity among the sensors and device such as signal cables or wires. we can eliminate the signal cable through the Zigbee sender and collector via implementing Zigbee-SD communication system that can receive the ECG signal data. We also implement ECG app software on the smart phone that can analyze and show the data results directly. It can give lots of mobility and usability under ubiquitous environment and would be a very efficient wireless ECG system for U-healthcare service.

The Telemedicine System based ECG Data using Bio-Signal Meter and Smart Device (생체신호 측정기와 스마트 디바이스를 활용한 심전도 데이터 기반의 원격진료 시스템)

  • Kim, Yi-Seul;Cho, Jinsoo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.3
    • /
    • pp.51-56
    • /
    • 2012
  • In this paper, we propose a telemedicine system based ECG data using a bio-signal meter and a smart device for treating faraway patients. This system is composed of a patch-shaped portable bio-signal meter, patient's smart device application, and doctor's PC software. Using these components, doctors and patients can do telemedicine. First, a patient measures his own ECG signal with a bio-signal meter and send the data to a doctor using a smart device application. Then, the doctor checks the ECG data, and make and send a diagnosis chart to web server. Likewise, doctors and patients can be offered a medical environment without time and space restraints. Applying this system to real medical system can improve the problem of low accessibility and efficiency and also can reduce medical expenses.

Implementation of the Portable ECG System Using Moving Average Filter and Adaptive Signal Processing (이동평균필터와 적응신호처리를 이용한 휴대형 ECG 시스템 구현)

  • Kim, Se-Jin;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.989-993
    • /
    • 2008
  • 본 연구에서는 생체신호 중 비침습적으로 측정이 가능하고 많은 건강정보를 포함하고 있는 ECG(electrocardiogram)신호를 일상생활 중 보다 편리하게 모니터링 할 수 있는 시스템을 구현하고자 하였다. 이를 위하여 벨트형 ECG전극 시스템을 개발하였으며, 배터리로 구동 가능한 초소형 저전력 ECG측정시스템을 구현하였다. 또한 측정된 ECG신호의 무선전송을 위하여 Zigbee호환 무선센서노드를 이용하여 초저전력 무선데이터 통신부를 구성하였고 PC상에서 ECG신호를 모니터링하기 위한 프로그램을 구현하였다. 그리고 ECG측정 시 움직임에 따라 발생하는 동잡음의 제거를 위하여 이동평균필터(moving average filter)를 이용하여 기저선 변화를 추출하였고 이를 적응필터의 참조신호로 사용하여 동잡음을 제거하였다. 실험 결과 본 연구에 의해 구현된 ECG전극 및 계측시스템을 통해 활동상태 에서도 ECG계측 가능성을 확인하였으며, 제안한 적응신호처리기법을 통해 활동 중 ECG측정에서 동잡음의 최소화가 가능함을 확인하였다.

  • PDF

Design and Implementation of a Real-time Bio-signal Obtaining, Transmitting, Compressing and Storing System for Telemedicine (원격 진료를 위한 실시간 생체 신호 취득, 전송 및 압축, 저장 시스템의 설계 및 구현)

  • Jung, In-Kyo;Kim, Young-Joon;Park, In-Su;Lee, In-Sung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.42-50
    • /
    • 2008
  • The real-time bio-signal monitoring system based on the ZigBee and SIP/RTP has proposed and implemented for telemedicine but that has some problems at the stabilities to transmit bio-signal from the sensors to the other sides. In this paper, we designed and implemented a real-time bio-signal monitoring system that is focused on the reliability and efficiency for transmitting bio-signal at real-time. We designed the system to have enhanced architecture and performance in the ubiquitous sensor network, SIP/RTP real-time transmission and management of the database. The Bluetooth network is combined with ZigBee network to distribute traffic of the ECG and the other bio-signal. The modified and multiplied RTP session is used to ensure real-time transmission of ECG, other bio-signals and speech information on the internet. The modified ECG compression method based on DWLT and MSVQ is used to reduce data rate for storing ECG to the database. Finally we implemented a system that has improved performance for transmitting bio-signal from the sensors to the monitoring console and database. This implemented system makes possible to make various applications to serve U-health care services.

Curvature Based ECG Signal Compression for Effective Communication on WPAN

  • Kim, Tae-Hun;Kim, Se-Yun;Kim, Jeong-Hong;Yun, Byoung-Ju;Park, Kil-Houm
    • Journal of Communications and Networks
    • /
    • v.14 no.1
    • /
    • pp.21-26
    • /
    • 2012
  • As electrocardiogram (ECG) signals are generally sampled with a frequency of over 200 Hz, a method to compress diagnostic information without losing data is required to store and transmit them efficiently on a wireless personal area network (WPAN). In this paper, an ECG signal compression method for communications onWPAN, which uses feature points based on curvature, is proposed. The feature points of P, Q, R, S, and T waves, which are critical components of the ECG signal, have large curvature values compared to other vertexes. Thus, these vertexes were extracted with the proposed method, which uses local extrema of curvatures. Furthermore, in order to minimize reconstruction errors of the ECG signal, extra vertexes were added according to the iterative vertex selectionmethod. Through the experimental results on the ECG signals from Massachusetts Institute of Technology-Beth Israel hospital arrhythmia database, it was concluded that the vertexes selected by the proposed method preserved all feature points of the ECG signals. In addition, it was more efficient than the amplitude zone time epoch coding method.

Removing Baseline Drift in ECG Signal using Morphology-pair Operation and median value (Morphology-pair 연산과 중간 값을 이용한 심전도 신호의 기저선 변동 잡음 제거)

  • Park, Kil-Houm;Kim, Jeong-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.8
    • /
    • pp.107-117
    • /
    • 2014
  • This paper proposed the method of removing baseline drift by eliminating local maxima such as P, R, T-wave signal region and local minima Q, S-wave signal region. We applied morphology-pair operations improved from morphology operation to the ECG signal. To eliminate overshoot in the result of morphology-pair operation, we apply median value operation to the result of morphology-pair operation. We use MIT/BIH database to estimate the proposed algorithm. Experiment result show that proposed algorithm removing baseline drift effectively without orignal ECG signal distortion.

Adaptive Sampling for ECG Detection Based on Compression Dictionary

  • Yuan, Zhongyun;Kim, Jong Hak;Cho, Jun Dong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.6
    • /
    • pp.608-616
    • /
    • 2013
  • This paper presents an adaptive sampling method for electrocardiogram (ECG) signal detection. First, by employing the strings matching process with compression dictionary, we recognize each segment of ECG with different characteristics. Then, based on the non-uniform sampling strategy, the sampling rate is determined adaptively. As the results of simulation indicated, our approach reconstructed the ECG signal at an optimized sampling rate with the guarantee of ECG integrity. Compared with the existing adaptive sampling technique, our approach acquires an ECG signal at a 30% lower sampling rate. Finally, the experiment exhibits its superiority in terms of energy efficiency and memory capacity performance.

Development of Signal Detection Methods for ECG (Electrocardiogram) based u-Healthcare Systems (심전도기반 u-Healthcare 시스템을 위한 파형추출 방법)

  • Min, Chul-Hong;Kim, Tae-Seon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.6
    • /
    • pp.18-26
    • /
    • 2009
  • In this paper, we proposed multipurpose signal detection methods for ECG (electrocardiogram) based u-healthcare systems. For ECG based u-healthcare system, QRS signal extraction for cardiovascular disease diagnosis is essential. Also, for security and convenience reasons, it is desirable if u-healthcare system support biometric identification directly from user's bio-signal such as ECG for this case. For this, from Lead II signal, we developed QRS signal detection method and also, we developed signal extraction method for biometric identification using Lead II signal which is relatively robust from signal alteration by aging and diseases. For QRS signal detection capability from Lead II signal, ECG signals from MIT-BIH database are used and it showed 99.36% of accuracy and 99.68% of sensitivity. Also, to show the performance of signal extraction capability for biometric diagnosis purpose, Lead III signals are measured after drinking, smoking, or exercise to consider various monitoring conditions and it showed 99.92% of accuracy and 99.97% of sensitivity.