• Title/Summary/Keyword: ECG monitoring system

Search Result 186, Processing Time 0.025 seconds

Development of Monitoring System for Biotelemetry Diagnosis of Multichannel ECG Data (다중채널 심전도 데이터의 원격진단을 위한 모니터링 시스템의 개발)

  • Jang, Won-Yeong;Jang, Won-Seok;Hong, Seung-Hong
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.113-120
    • /
    • 1991
  • This paper describes the implementation of a 3 channel ECG monitoring system. This system consists of an IBM-PC and simple accessory only. A PDTS (parallel data transmission system ) was designed to do monitor the data being operated with no effect and no exchange of software and hardware on the main transmission system in LOCAL mode. And it receives patient's ECG data from EPTS ( ECG processing and transmission system) of distant region. It provides on-line ECG waveform display, waveform storage, recall and editing the waveform. We have implemented the monitoring system by tw methods, and with system, we could directly monitor the EPTS and also receive the data from the remote ㅁe잉ion. This system was tested by experiments and examined its practical use.

  • PDF

Development of Realtime ECG Analysis and Monitoring System (실시간 심전도 분석 및 모니터링 시스템 개발)

  • Jeong, Gu-Young;Yoon, Myoung-Jong;Yu, Kee-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.4
    • /
    • pp.406-412
    • /
    • 2009
  • ECG is used on purpose to keep good health or monitor cardiac function of aged person as well as on purpose to diagnose the disease of heart patients. The ambulatory ECG monitoring system under guarantee of safety and accuracy is very efficient to prevent the progress of heart disease and sudden death. These systems can detect the temporary change of ECG that is very significant to diagnose heart disease such as myocardial ischemia, arrhyamia and cardiac infarction. In this paper, we describe the ECG signal analysis algorithm and measurement device for ECG monitoring. The authors designed a small-size portable ECG device that consisted of instrumentation amplifier, micro-controller, filter and RF module. The device measures ECG with four electrodes on the body and detects QRS complex and ST level change in realtime. Also it transmits the measured signals to the personal computer. The developed software for ECG analysis in personal computer has the function to detect the feature points and ST level changes.

A study on WSN based ECG and body temperature measuring system for ubiquitous healthcare: 2. Vital signal monitoring software system (유비쿼터스 헬스케어를 위한 센서 네트워크 기반의 심전도 및 체온 측정 시스템: 2. 생체신호 모니터링 소프트웨어 시스템)

  • Lee, Dae-Seok;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.417-424
    • /
    • 2006
  • An ubiquitous healthcare monitoring system for elderly person at home was designed for continuous healthy monitoring of elderly person or patients. Human vital signals, such as ECG and body temperature, were monitored by terminal PC or PDA via ECG and temperature sensor nodes on the patient's body. From the ECG data, the heart rate, tachycardia, bradycardia and arrhythmia were diagnosed on the terminal PC or PDA to assist doctor's or nurse's aid or patient itself to monitor the patient's condition and give medical examination. Artificial judgement support system was designed in server computer and the system support a doctor or nurser for management or treatment of the patient. This system can be applied to vital signal monitoring system for solitude elderly person at self house or home health care service part. And this ubiquitous healthcare system can reduce the medical expenses in coming aging or aged society.

A Wrist Watch-type Cardiovascular Monitoring System using Concurrent ECG and APW Measurement

  • Lee, Kwonjoon;Song, Kiseok;Roh, Taehwan;Yoo, Hoi-jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.702-712
    • /
    • 2016
  • A wrist watch type wearable cardiovascular monitoring device is proposed for continuous and convenient monitoring of the patient's cardiovascular system. For comprehensive monitoring of the patient's cardiovascular system, the concurrent electrocardiogram (ECG) and arterial pulse wave (APW) sensor front-end are fabricated in $0.18{\mu}m$ CMOS technology. The ECG sensor frontend achieves 84.6-dB CMRR and $2.3-{\mu}Vrms$-input referred noise with $30-{\mu}W$ power consumption. The APW sensor front-end achieves $3.2-V/{\Omega}$ sensitivity with accurate bio-impedance measurement lesser than 1% error, consuming only $984-{\mu}W$. The ECG and APW sensor front-end is combined with power management unit, micro controller unit (MCU), display and Bluetooth transceiver so that concurrently measured ECG and APW can be transmitted into smartphone, showing patient's cardiovascular state in real time. In order to verify operation of the cardiovascular monitoring system, cardiovascular indicator is extracted from the healthy volunteer. As a result, 5.74 m/second-pulse wave velocity (PWV), 79.1 beats/minute-heart rate (HR) and positive slope of b-d peak-accelerated arterial pulse wave (AAPW) are achieved, showing the volunteer's healthy cardiovascular state.

A Centralized Monitoring System for Infant Incubators Using Bluetooth (블루투스를 이용한 신생아 인공 보육기의 중앙감시 장치)

  • Kim Joo-Sik;Ahn Hyun-Sik;Jeong Gu-Min
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.1
    • /
    • pp.33-37
    • /
    • 2006
  • In this paper, we present a centralized monitoring system for infant incubator using Bluetooth. Conventional monitoring systems for incubators require large space and wire connection, which causes the spatial restrictions. To overcome this disadvantage, centralized monitoring system is proposed for infant incubators using Bluetooth. The implemented system consists mainly of transmission systems and receiver systems. There are temperature sensors, humidity sensors, ECG measurement units and Bluetooth modules in the transmission systems. For temperature, humidity and ECG data, the transmission systems acquire them from the measuring modules in the incubator and transmits the signals using Bluetooth. In the receiver system, users can see the status of the infant by accessing the central monitoring host computer. That is, one can monitor the information on the temperature and the humidity in the incubator and Infant's ECG without dependence to a conventional bulky system. Also, the system manager in the receiver system can maintain centralized monitoring of the situations in all incubators and infant. The developed system will be useful in remote diagnosis of infant incubator In various environments.

  • PDF

Portable ECG Sensor Module and Monitoring System Implementation Considering Reduction of Powerline Noise and Baseline Wander (전원잡음과 기저선변동을 고려한 이동형 ECG 센서모듈 및 모니터링 시스템 구현)

  • Oh Do-Chang;Choi Dong-Hyuk;Lee Hong-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.10
    • /
    • pp.1022-1028
    • /
    • 2006
  • A portable ECG sensor module and monitoring system which has the powerline noise reduction and the baseline wander removal is proposed. A small-szie ECG sensor H/W module with the 8-bits microprocessor is implemented. The ECG waveform can be inspected anytime with PDA in real time, and transmitted to the PC through wireless LAN. Portable ECG system can offer the environment that give the lasting medical service to the elderly and the long-time hospitalized patients at the wanted place, and the system can be attached to the chair, wheel chair, treadmill, elderly walker and used to monitor the health condition of man

Developement of ECG monitoring system (심전도 감시장치의 개발에 관한 연구)

  • Kim, N.H.;Shim, W.H.;Kim, G.H.;Ra, S.W.;Lee, G.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.461-464
    • /
    • 1997
  • The ECG monitoring system had play a significant roll in ICU, CCU and operating room. By alarming the change of ECG wave form and heart rate, staff can control emergency state. The improve of recent digital technology is able to develope low cost and high quality ECG monitoring system. In this paper, we develope new monitoring system with low price microprocessor and control system.

  • PDF

Development of a Low-power Portable Wireless ECG System for Monitoring the Emergency Patient during Transfer in Hospital (응급환자 병원내 이송중의 모니터링을 위한 저전력형 휴대용 무선 ECG 시스템 개발)

  • Jang, Kee-Woong;Kim, Ji-Won;Kong, Se-Jin;Kim, Chul-Seung;Eom, Gwang-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2163-2164
    • /
    • 2006
  • It is desirable to monitor the vital signals, such as ECG, of a emergency patient during transfer in the hospital as well as in the ambulance. The purpose of this study is to develop a system which provides a real-time and wireless ECG to the medical staff nearby patient during transfer in hospital. In this context, we developed a low-power, low-cost and portable ECG system consisting of 1) ECG measurement and RF transmission module and 2) RF receiving and LCD display module. The developed system is expected to be useful in monitoring ECG of a patient during transfer in the hospital.

  • PDF

Implementation of Extended Kalman Filter for Real-Time Noncontact ECG Signal Acquisition in Android-Based Mobile Monitoring System

  • Rachim, Vega Pradana;Kang, Sung-Chul;Chung, Wan-Young;Kwon, Tae-Ha
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • Noncontact electrocardiogram (ECG) measurement using capacitive-coupled technique is a very reliable long-term noninvasive health-care remote monitoring system. It can be used continuously without interrupting the daily activities of the user and is one of the most promising developments in health-care technology. However, ECG signal is a very small electric signal. A robust system is needed to separate the clean ECG signal from noise in the measurement environment. Noise may come from many sources around the system, for example, bad contact between the sensor and body, common-mode electrical noise, movement artifacts, and triboelectric effect. Thus, in this paper, the extended Kalman filter (EKF) is applied to denoise a real-time ECG signal in capacitive-coupled sensors. The ECG signal becomes highly stable and noise-free by combining the common analog signal processing and the digital EKF in the processing step. Furthermore, to achieve ubiquitous monitoring, android-based application is developed to process the heart rate in a realtime ECG measurement.

Implementation of Wearable Heart Activity Monitoring System having Modified Bipolar Electrode and Correlation Analysis with Clinical Electrocardiograph(ECG) (수정된 바이폴라 전극을 갖는 착용형 심장활동 모니터링 시스템 구현 및 임상 심전도와의 상관관계 분석)

  • Lee, Kang-Hwi;Lee, Jeong-Whan;Lee, Young-Jae;Kim, Kyeong-Seop;Yang, Heui-Koung;Shin, Kun-Su;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1102-1108
    • /
    • 2008
  • Wearable physiological signal monitoring systems are regarded as an important sensing unit platforms in ubiquitous/mobile healthcare application. In this paper, we suggested the modified bipolar electrodes implemented on the portable heart activity monitoring system, which minimized the distance of electrodes formed on a attachable pad. The proposed electrode configuration is useful in mobile measurement environments, but has a disadvantage of reduced amplitude of the heart action potential. In order to overcome the shortcoming of the suggested electrode configuration, we implemented the amplifying circuit to increase the signal-gain and decrease the artifacts. For evaluations, we analyzed the specificity of measured cardiography using the proposed electrodes through the comparing of heart activity monitoring system with standard clinical ECG(lead2) by pearson correlation coefficients. The result showed that the average correlation coefficient is $0.903{\pm}0.036,\;0.873{\pm}0.072$ at V3, V4 chest lead position, respectively. Thus, the modified bipolar electrode is quite suitable to monitor the electrical activity of the heart in the situation of the mobile environment, and could be considered having high similarity with standard clinical ECG.