• 제목/요약/키워드: ECG electrode

검색결과 87건 처리시간 0.019초

체표 변화에 기반한 심전도 모니터링 의류의 센싱 위치 연구 (A Study of Sensing Locations for ECG Monitoring Clothing based on the Skin Change rate)

  • 조하경;조상우
    • 한국의류산업학회지
    • /
    • 제17권5호
    • /
    • pp.844-853
    • /
    • 2015
  • Recently, according to change of lifestyle and increase of concerning in health, needs of the smart clothing based on the vital sign monitoring have increased. Along with this trend, smart clothing for ECG monitoring has been studied various way as textile electrode, clothing design and so on. Smart clothing for ECG monitoring can become a comfortable system which enables continuous vital sign monitoring in daily use. But, smart clothing for ECG monitoring has a weakness on artifact during motion. One of the motion artifact caused by shifting of the electrode position was affected skin change by motion. The aim of this study was to suggest electrode locations for clothing of ECG monitoring to reduce of motion artifacts. Therefore, change of skin surface during the movement were measured and analyzed in order to find location to minimize motion artifacts in ECG monitoring clothing by 3D motion capture. For the experiment, the subjects consisted of 5 males and 5 females in their 20' with average physique. As a result, the optimal location for ECG monitoring was deducted under the bust line and scapula which have least motion artifact. These locations were abstracted to be least affected by movement in this research.

심장 전기활동 계측을 위한 소형 섬유전극 개발 및 특성 고찰 (Development of Miniaturized Textile Electrode for Measuring Heart Electric Activity)

  • 이영재;이정환;양희경;이주현;강다혜;조현승;안인석
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1186-1193
    • /
    • 2009
  • Wearable ECG monitoring is regarded as one of the most essential part in the ubiquitous healthcare environment and subsequently day-life monitoring of a heart condition has been pursued especially for the elder people. However, there are many problems to accomplish this task such as; i) implementation of long-term monitoring device, ii) development of non-irritating electrode on skin and iii) stable signal acquisition. With these aims, we have focused on implementing a non-irritating electrode with an endurable monitoring device for day-life. To accomplish our tasks, we basically developed four different types of textile electrodes that are adapted by both shape and the composed material; flat or convex shape and Ag-conductive paste material or not. It turns out to be that a convex shape and Ag-paste textile electrode has the best performance in terms of both signal-to-noise ratio (SNR) and Impedance/Phase characteristics. Furthermore, ECG amplifier (35 ${\times}$ 35 mm) has developed to resolve the ECG signal and transfer the signal to desktop computing device or portable one by RF serial communication.

휴대용 심전도 기기와 직물형 전극을 이용한 생체정보 측정용 밀착 의복 개발 (Development of Tight-Fitting Garments with a Portable ECG Monitor to Measure Vital Signs)

  • 정연희;김승환;양영모
    • 한국의류학회지
    • /
    • 제34권1호
    • /
    • pp.112-125
    • /
    • 2010
  • A Holter monitor is used for ECG monitoring of ambulatory daily life in hospital. However, the use of this apparatus causes skin allergies and discomfort in patients because of the attachment gel and tapes used to attach disposable electrodes to the skin. In this study, the development of tight-fitting clothing connected to a portable Holter monitor was proposed. In addition, the use of conductive fabrics as electrodes was proposed; this will enable the use of garments in u-health care for measuring ECG signals. The male subjects were university students in the ages of 20 to 24. Subjective wear sensations of the experimental garments were rated using seven Likert scales. A Likert type scale was used for the evaluation and a 7 point score indicates that it provided the best fit as a tight-fitting upper clothing. Clothing pressure was measured using an air-pack-type pressure sensor (model AMI 3037-2) at 4 locations (the conductive fabric electrode) As results, a male basic sloper for upper clothing was developed and that pattern was manipulated to the tight fit pattern by considering the reduction rate of the percentage stretch in the fabric. The developed tight-fitting garment was superior in terms of subjective sensation and 6t. The mean pressure of the garment with reduction rates of 40% in width and of 50% in length was 8.45gf/$cm^2$. A conductive fabric electrode was developed by considering the sewing method and the developed electrode was detected well. The ECG data were recorded for 13 hr 19 min 44 sec and the artifacts in the ECG signals were recorded for 9 hr 3 min 46 sec (total time: 22 hr 23 min 23 sec). The artifacts data were obtained during heavy activities.

용량성 결합 능동 전극의 내부 잡음 분석 (A Study on Intrinsic Noise of Capacitively Coupled Active Electrode)

  • 임용규
    • 융합신호처리학회논문지
    • /
    • 제13권1호
    • /
    • pp.44-49
    • /
    • 2012
  • 간접접촉 심전도 측정(Indirect-Contact ECG)은 일상생활에서의 무구속 무자각 측정에 적합한 새로운 심전도 측정 방법이다. 간접접촉 심전도 측정 에 서 관측되는 큰 배경 잡음을 줄이기 위한 기초 연구로서, 본 연구에서는 간접 접촉 심전도에서 사용되는 용량성 결합 능동 전극(Capacitively coupled active electrode)의 열잡음(Thermal Noise) 모델을 구성하였다. 실험을 통해, 용량성 결합 능동 전극만의 배경 잡음의 크기가 열잡음 모델에서 예상한 수준과 거의 일치함을 확인하였다. 면으로 된 직물의 실제의 전기적 특성을 열잡음 모델에 적용하여, 면 위에서 측정된 간접접촉 심전도의 이론적 열잡음을 계산하였다. 이 연구를 통해, op-amp의 내부 잡음(intrinsic noise)은 저항에 의한 열잡음에 비해 무시할 수 있을 정도로 작음을 알 수 있었다. 그리고 열잡음의 크기와 능동 전극의 입력 저항간의 관계를 도출할 수 있게 되어, 능동 전극의 입력 저항의 최적 값 선정을 위한 향후 연구의 기반이 되었다.

간접접촉 심전도 측정에서의 오른발구동 접지의 효과와 한계 (The Effect and the Limitation of Driven-right-leg Ground on Indirect-contact ECG measurement)

  • 임용규
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권2호
    • /
    • pp.103-108
    • /
    • 2018
  • This study reviews the common-mode noise model of indirect-contact ECG measurement which uses capacitive electrode and capacitive ground, and shows the reason of the large common-mode noise in indirect-contact ECG. And then, this study shows driven-right-leg ground in indirect-contact ECG measurement, and reviews how the driven-right-leg ground reduces the common-mode noise. This study then analyzes the relation between the effective area of the indirect-contact ground and the gain of the driven-right-leg circuit. This study introduces the output voltage saturation of the driven-right-leg circuit, which occurs frequently in indirect-contact ECG measurement with the condition of the high ground impedance. This study then shows the effect of the driven-right-leg circuit saturation on the common-mode noise.

섬유전극을 기반으로 한 라이프스타일 모니터링용 ECG-센싱의류의 프로토타입 연구 (A Study on a Prototype of ECG-Sensing ClothingBased on Textile Electrode for Lifestyle Monitoring)

  • 강다혜;조하경;송하영;조현승;이주현;이강휘;구수민;이영재;이정환
    • 감성과학
    • /
    • 제11권3호
    • /
    • pp.419-426
    • /
    • 2008
  • In order to develop "textile electrode - sensing clothing" which is a sort of smart clothing to measure electric activities of heart, we propose possible ways to develop textile electrode and design of sensing clothing, ultimately aiming to develop "ECG sensing clothing for lifestyle monitoring". Conventional sensors for measuring typical electric activities of heart keep certain distance between measuring electrodes to measure signals for electric activities of heart, but these sensors often cause inappropriate factors (e.g. motional artifacts, inconvenience of use, etc) for monitoring natural cardiac activities in our daily life. In addition, most of textile electrodes have made it difficult to collect data due to high impedance and unstable contact between skin and electrodes. To overcome these questions, we minimized distance between electrodes and skin to maximize convenience of use. And in order to complement contact between skin electrodes, we modified textile electrode's form and developed ways to design clothing. As a result, we could find out clinical significance by investigating possible associations of clinical electrocardiogram (ECG) with variation of distance between electrodes, and could also demonstrate clinically significant associations between textile electrode developed herein and clothing.

  • PDF

용량성 결합 능동 전극의 공통 모드 구동 차폐 (A Study on comnon-mode-driven shield for capacitive coupling active electrode)

  • 임용규
    • 융합신호처리학회논문지
    • /
    • 제13권4호
    • /
    • pp.201-206
    • /
    • 2012
  • 간접접촉 심전도 측정(Indirect-Contact ECG)은 일상생활에서의 무구속 무자각 측정에 적합한 심전도 측정 방법이다. 본 연구는, 간접접촉 심전도 측정에서 크게 관측되는 60Hz 전원선 잡음을 줄이기 위한 새로운 방법으로, 공통모드 구동 차폐 방식을 제안하였다. 공통 모드 구동 차폐 방식은, 간접 접촉 심전도에서 사용되는 용량성 결합 능동 전극(Capacitive coupling active electrode)을 둘러싼 전기적 차폐(electric shield)의 전압을 공통 모드 전압과 동일하게 유지하는 방법이다. 이 방법은 공통모드 전압의 크기는 그대로 유지하지만, 의복 임피던스 차에 의한 공통모드 전압의 차동 모드 전환에 의한 잡음은 효과적으로 줄일 수 있다. 따라서 두 전극 사이의 의복의 임피던스 차이가 커서 공통 모드 전원 잡음이 심각한 간접 접촉 심전도 측정에서, 효과적으로 공통 모드 잡음을 줄일 수 있다. 실제 간접 접촉 심전도 측정에 제안된 방법을 적용한 결과로 이론적 예상보다는 60Hz 잡음 감소비가 적었지만, 60Hz 잡음이 크게 줄어드는 것을 확인할 수 있었다. 특히 의복 임피던스 차가 크게 발생하는 경우, 예상대로 잡음 감소비가 커짐을 볼 수 있었다. 제안된 방법은 접지 특성이 좋지 않은 측정 조건에서 전원 잡음을 줄이는데 유용할 것으로 기대된다.

공통-모드 간섭 (CMI)에 강인한 2-전극 기반 심전도 계측 회로 (CMI Tolerant Readout IC for Two-Electrode ECG Recording)

  • 강상균;남경식;고형호
    • 센서학회지
    • /
    • 제32권6호
    • /
    • pp.432-440
    • /
    • 2023
  • This study introduces an efficient readout circuit designed for two-electrode electrocardiogram (ECG) recording, characterized by its low-noise and low-power consumption attributes. Unlike its three-electrode counterpart, the two-electrode ECG is susceptible to common-mode interference (CMI), causing signal distortion. To counter this, the proposed circuit integrates a common-mode charge pump (CMCP) with a window comparator, allowing for a CMI tolerance of up to 20 VPP. The CMCP design prevents the activation of electrostatic discharge (ESD) diodes and becomes operational only when CMI surpasses the predetermined range set by the window comparator. This ensures power efficiency and minimizes intermodulation distortion (IMD) arising from switching noise. To maintain ECG signal accuracy, the circuit employs a chopper-stabilized instrumentation amplifier (IA) for low-noise attributes, and to achieve high input impedance, it incorporates a floating high-pass filter (HPF) and a current-feedback instrumentation amplifier (CFIA). This comprehensive design integrates various components, including a QRS peak detector and serial peripheral interface (SPI), into a single 0.18-㎛ CMOS chip occupying 0.54 mm2. Experimental evaluations showed a 0.59 µVRMS noise level within a 1-100 Hz bandwidth and a power draw of 23.83 µW at 1.8 V.

Electrode Characteristics of Non-contact Electrocardiographic Measurement

  • Mathias, Dakurah Naangmenkpeong;Kim, Sung-Il;Park, Jae-Soon;Joung, Yeun-Ho;Choi, Won Seok
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권1호
    • /
    • pp.42-45
    • /
    • 2015
  • The ability to take electrocardiographic measurements while performing our daily activities has become the people-choice for modern age vital sign sensing. Currently, wet and dry ECG electrodes are known to pose threats like inflammations, allergic reactions, and metal poisoning due to their direct skin interaction. Therefore, the main goal in this work is to implement a very small ECG sensor system with a capacitive coupling, which is able to detect electrical signals of heart at a distance without the conductive gel. The aim of this paper is to design, implement, and characterize the contactless ECG electrodes. Under a careful consideration of factors that affect a capacitive electrode functional integrity, several different sizes of ECG electrodes were designed and tested with a pilot ECG device. A very small cotton-insulated copper tape electrode ($2.324cm^2$) was finally attained that could detect and measure bioelectric signal at about 500 um of distance from the subject's chest.

무구속 전극을 이용한 의자형 심전도 모니터링 시스템의 구현 및 평가 (Implementation and Evaluation of Chair-type ECG Monitoring System using Unconstraint Electrode)

  • 노윤홍;정도운
    • 융합신호처리학회논문지
    • /
    • 제16권2호
    • /
    • pp.56-62
    • /
    • 2015
  • 본 연구에서는 현대인들의 일상생활 중 대부분의 시간을 보내는 좌식생활 중에 무구속적으로 장시간 심장활동상태를 모니터링하기 위한 의자형 무구속 심전도 모니터링 시스템을 설계 및 구현하였다. 구현된 시스템은 옷을 입은 상태에서도 측정이 가능하며, 동잡음에도 비교적 강한 장점을 가진다. 이를 위하여 의자의 등받이 부분에 무구속 전극을 배치하였으며, 미세한 생체신호를 증폭하고, 측정 시 발생 할 수 있는 동잡음 및 기저선의 변화, 상용전원에 의한 전원잡음을 제거하기 위하여 증폭기 및 필터를 설계하였다. 또한 제어부와 무선전송부를 구현하여 아날로그 신호를 디지털 신호로 변환하고 생체신호를 PC와 스마트폰으로 전송함으로써 일상생활 중 지속적인 심장활동 상태의 모니터링이 가능하다. 구현된 시스템의 성능을 평가하기 위하여 Ag/AgCl 전극을 사용한 시스템과 비교 실험을 수행하였으며, 실험 결과 구현된 시스템의 무구속적으로 심장활동 상태 모니터링이 가능함을 확인하였다.