• Title/Summary/Keyword: ECG analysis system

Search Result 170, Processing Time 0.028 seconds

Effects of Acupuncture Stimulation on the Radial artery's Pressure Pulse Wave in Healthy Young Participants: Protocol for a prospective, single-Arm, Exploratory, Clinical Study

  • Shin, Jae-Young;Ku, Boncho;Kim, Tae-Hun;Bae, Jang Han;Jun, Min-Ho;Lee, Jun-Hwan;Kim, Jaeuk U.
    • Journal of Pharmacopuncture
    • /
    • v.19 no.3
    • /
    • pp.197-206
    • /
    • 2016
  • Introduction: This study aims to investigate the effects of acupuncture stimulation on the radial artery's pressure pulse wave, along with various hemodynamic parameters, and to explore the possible underlying mechanism of pulse diagnosis in healthy participants in their twenties. Methods and analysis: This study is a prospective, single-arm, exploratory clinical study. A total of 25 healthy participants, without regard to gender, in their twenties will be recruited by physicians. Written informed consent will be obtained from all participants. The participants will receive acupuncture once at ST36 on both sides. The radial arterial pulse waves will be measured on the left arm of the subjects by using an applicable pulse tonometric device (KIOM-PAS). On the right arm (appearing twice), electrocardiogram (ECG), photoplethysmogram (PPG), respiration and cardiac output (CO) signals, will be measured using a physiological data acquisition system (Biopac module), while the velocity of blood flow, and the diameter and the depth of the blood vessel will be measured using an ultrasonogram machine on the right arm (appearing twice). All measurements will be conducted before, during, and after acupuncture. The primary outcome will be the spectral energy at high frequencies above 10 Hz ($SE_{10-30Hz}$) calculated from the KIOM-PAS device signal. Secondary outcomes will be various variables obtained from the KIOM-PAS device, ECG, PPG, impedance cardiography modules, and an ultrasonogram machine. Discussion: The results of this trial will provide information regarding the physiological and the hemodynamic mechanisms underlying acupuncture stimulation and clinical evidence for the influence of acupuncture on the pressure pulse wave in the radial artery. Ethics and dissemination: This study was approved by the Institutional Review Board (IRB) of Kyung Hee University's Oriental Medical Center, Seoul, Korea (KOMCIRB-150818-HR-030). The study findings will be published in peer-reviewed journals and presented at national and international conferences. Trial registration number: This trial was registered with the Clinical Research Information Service (CRIS) at the Korea National Institute of Health (NIH), Republic of Korea (KCT0001663), which is a registry in the World Health Organization's (WHO's) Registry Network.

Study a Technique for Reducing the Influence of Scattered Rays from Surrounding Organs to the Heart during Gated Cardiac Blood Pool scan (Gated Cardiac Blood Pool scan에서의 심장 주위 배후방사능 관심영역 설정시 산란선의 영향을 감소시키기 위한 연구)

  • Kim, Jung-Yul;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.33-38
    • /
    • 2008
  • Purpose: The Gated cardiac blood pool scan is non-invasive method that a quantitative evaluation of left ventricular function. Also this scan have shown the value of radionuclide ejection fraction measurements during the course of chemotherapy as a predictor of cardiac toxicity. Therefore a reliable method of monitoring its cardiotoxic effects is necessary. the purpose of this study is to minimize the overestimate of left ventricular ejection fraction (LVEF) by modified body position to reduce the influence of scattered rays from surrounding organs of the heart in the background region of interest. Materials and Methods: Gated cardiac blood pool scan using in vivo $^{99m}Tc$-red blood cell (RBC) was carried out in 20 patients (mean $44.8{\pm}8.6$ yr) with chemotherapy for a breast carcinoma. Data acquisition requires about 600 seconds and 24 frames of one heart cycle by the multigated acquisition mode, Synchronization deteriorates toward the end of the cycle and with the distance from the trigger signal (R-wave) by ECG gating. Gated cardiac blood pool scan was studied with conventional method (supine position and the detector head in $30-45^{\circ}$ left anterior oblique position and caudal $10-20^{\circ}$ tilt) and compared with modified method (left lateral flexion position with 360 mL of drinking water). LVEF analysis was performed by using the automatically computer mode. Results: The ROI counts of modified scan method were lower than LV conventional method ($1429{\pm}251$ versus $1853{\pm}243$, <0.01). And LVEF of modified method was also decrease compared with conventional method ($58.3{\pm}5.6%$ versus $65.3{\pm}6.1%$, <0.01). Imaging analysis indicated that stomach was expanded because of water and spleen position was changed to lateral inferior compared with conventional method. Conclusion: This study shows that the modified method in MUGA reduce the influence of scattered rays from surrounding organs. Because after change the body position to left lateral flexion and drinking water, the location of spleen, left lobe of liver and stomach had changed and they could escaped from background ROI. Therefore, modified method could help to minimize the overestimate LVEF (%).

  • PDF

Measurement of Cardiac Pulse Transit Time using Photoplethysmography Sensor (광전용적맥파 센서를 이용한 맥파전달시간의 측정)

  • Choi, Byeong-Cheol;Jung, Dong-Keun;Jeong, Do-Un;Ro, Jung-Hun;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.383-391
    • /
    • 2004
  • In this study, we implemented the pulse transit time (PTT) system to examine usefulness of the monitoring method of distensibility and elasticity using photoplethysmography sensor in vivo. PTT is defined as the time interval between the peak of QRS complex in ECG signal and the maximum slope point of photoplethysmography. these two signals were converted to digital data by means of AID converter, then PTT was evaluated by heartbeat using PC. Results of analysis were displayed as a graph using spline interpolation method. The variance of PTT was measured repetitiously to verify efficiency of PTT system in resting state and hyperemic state. Repeated measurement of PTT was not same value but showed that coefficients of correlation were related with each other as 0.8302 (P<0.01) in resting state. And also repeated measurement of PTT showed significant correlation as 0.868 (P<0.01) in the hyperemic state. These result showed that PTT is reflect on transient pressure variance in the artery and is very useful method for the evaluation of prognosis of the hypertension and arteriosclerosis.

Estimating blood pressure using the pulse transit time of the two measuring from pressure pulse and PPG

  • Kim, Gi-Ryon;Ye, Soo-Young;Kim, Jae-Hyung;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.87-94
    • /
    • 2008
  • Blood pressure (BP), one of the most important vital signs, is used to identify an emergency state and reflects the blood flow characteristics of the cardiovascular system. The conventional noninvasive method of measuring BP is inconvenient because patients must wear a cuff on their arm and the measurement process takes time. This paper proposes an algorithm for estimating the BP using the pulse transit time (PTT) of the photoplethysmography (PPG) and pressure pulse from finger at the same time as a more convenient way to measure the BP. After recording the electrocardiogram (ECG), measuring the pressure pulse, and performing PPG, we calculated the PTT from the acquired signals. Then, we used a multiple regression analysis to measure the systolic and diastolic BP indirectly. Comparing the BP measured indirectly using the proposed algorithm and the real BP measured with a sphygmomanometer, the systolic pressure had a mean error of ${\pm}3.240$ mmHg and a standard deviation of 2.530 mmHg, while the diastolic pressure had a satisfactory result, i.e., a mean error of ${\pm}1.807$ mmHg and a standard deviation of 1.396 mmHg. These results are more superior than existing method estimating blood pressure using the one PTT and satisfy the ANSI/AAMI regulations for certifying a sphygmomanometer i.e., the measurement error should be within a mean error of ${\pm}5$ mmHg and a standard deviation of 8 mmHg. These results suggest the possibility of applying our method to a portable, long-term BP monitoring system.

Design and Implementation of Electrocardiogram Data Interpretation system using AdaBoost Algorithm (AdaBoost 알고리즘을 이용한 심전도 정보 판독 시스템의 설계 및 구현)

  • Lim, Myung-Jae;Hong, Jin-Kyoung;Kim, Kyu-Ho;Choi, Mi-Lim
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.2
    • /
    • pp.129-134
    • /
    • 2010
  • Diseases such as cardiovascular illnesses, according to the National Statistical Office opened reveals that 600-800 people were killed, blood pressure, arteriosclerosis, heart disease, stroke, etc. will be a flow of blood disorders that occur in cardiovascular illnesses today are fulfilling the Master / Slave samangryulin disease appears high. Died of cardiovascular disease also told them the correct first aid survival when patients are accounted for approximately 40% of emergency rapid response is required. Therefore, this paper, the weak classifier in the AdaBoost algorithm to generate a strong classifier by combining effects throughout the analysis to measure the ECG, and cardiovascular disease that occurred to you as soon as the emergency management system that can deliver on the proposed Desk was. The electrocardiogram data measured by the ZigBee-based sensors, communication devices and emergency transport for emergency alarms in the determination and monitoring of the management desk by providing health services to enable the delivery was fast.

Effect of Horizontal Eye Movements on the Heart Rate Variability after Exposure to a Fear-Inducing Film Clip (공포 영화 장면 노출 후 수평적 안구 운동이 심박수 변이도에 미치는 영향)

  • Lee, Haewon;Yum, Myung-Kul;Kim, Seok Hyeon;Lee, Yun Jeong;Kim, Daeho
    • Korean Journal of Biological Psychiatry
    • /
    • v.15 no.1
    • /
    • pp.35-45
    • /
    • 2008
  • Objectives : There has been a continued debate regarding the role of eye movements in Eye Movement Desensitization and Reprocessing(EMDR). This study examined the possible autonomic effect of horizontal eye movements after being exposed to fearful stimuli. Methods : Fifty two healthy adult women were randomly allocated to eye movement or eye fixed groups after watching a five minute fear-inducing film clip. ECG was recorded during the resting state, after watching the clip, and the treatment. A spectral power analysis of the heart rate variability was performed. As the variables violated the rule of normal distribution and the number in each group is small the non-parametric test was used. Results : Overall, we did not find the differences between the groups in both time and frequency domains. Some minor differences found were not consistent with results from previous studies. Conclusions : Effect of eye movement on autonomic nervous system during fear desensitization was not supported in this experiment. Further study with other psychophysiological measures is needed to understand the role of eye movements in treatment of traumatic memory.

  • PDF

Basic Physiological Research on the Wing Flapping of the Sweet Potato Hawkmoth Using Multimedia

  • Nakajima, Isao;Yagi, Yukako
    • Journal of Multimedia Information System
    • /
    • v.7 no.2
    • /
    • pp.189-196
    • /
    • 2020
  • We have developed a device for recording biological data by inserting three electrodes and a needle with an angular velocity sensor into the moth for the purpose of measuring the electromyogram of the flapping and the corresponding lift force. With this measurement, it is possible to evaluate the moth-physiological function of moths, and the amount of pesticides that insects are exposed to (currently LD50-based standards), especially the amount of chronic low-concentration exposure, can be reduced the dose. We measured and recorded 2-channel electromyography (EMG) and angular velocity corresponding to pitch angle (pitch-like angle) associated with wing flapping for 100 sweet potato hawkmoths (50 females and 50 males) with the animals suspended and constrained in air. Overall, the angular velocity and amplitude of EMG signals demonstrated high correlation, with a correlation coefficient of R = 0.792. In contrast, the results of analysis performed on the peak-to-peak (PP) EMG intervals, which correspond to the RR intervals of ECG signals, indicated a correlation between ΔF fluctuation and angular velocity of R = 0.379. Thus, the accuracy of the regression curve was relatively poor. Using a DC amplification circuit without capacitive coupling as the EMG amplification circuit, we confirmed that the baseline changes at the gear change point of wing flapping. The following formula gives the lift provided by the wing: angular velocity × thoracic weight - air resistance - (eddy resistance due to turbulence). In future studies, we plan to attach a micro radio transmitter to the moths to gather data on potential energy, kinetic energy, and displacement during free flight for analysis. Such physiological functional evaluations of moths may alleviate damage to insect health due to repeated exposure to multiple agrochemicals and may lead to significant changes in the toxicity standards, which are currently based on LD50 values.

Assessment of Laryngeal Function by Pitch Perturbation Analysis and Hilbert Transform of EGG Signal (ECG신호의 피치변동해석 및 Hilbert변환에 의한 후두기능의 평가)

  • 송철규;이명호
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.95-100
    • /
    • 1995
  • In this study, we have evaluated the effect of amplitude and frequency perturbation of EGG signal for single vowels associated with laryngeal pathology. The normal EGG signal was properly characterized by an autoregressive model which has an optimal order of ninth using the parametric method. This can be analyzed by determining the transfer function. Perturbations in the fundamental pitch and in the peak amplitude of EGG signal measured with a four-electrode system using the modulation/demodulation techniques were investigated for the purpose of developing a decision criteria for the laryngeal function analysis. The abnormal EGG signal has nonperiodic and unstable characteristics. It can be discriminated by the calculation of opening and closing time of glottis using the EGG signal. In case of normal and abnormal subjects, m$\pm$0.5*sd was discriminating line for frequency perturbation and m$\pm$2*sd for normal amplitude perturbations, respectively. Also, The normal and abnormal cases of the subjects can be discriminated effectively using the pattern of attractor derived with Hilbert transform of EGG signal.

  • PDF

Development of a Pulse Wave Velocity Measurement System and Assessment of the System Reproducibility for the Diagnosis of Arteriosclerosis (동맥경화 진단을 위한 맥파전달속도 측정시스템 개발 및 재현성 평가)

  • Lee, Nak-B.;Im, Jae-J.;Park, Young-B.;Jeon, Young-J.
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.1
    • /
    • pp.112-124
    • /
    • 2005
  • Background: PWV is determined by dividing the distance by the time taken for the pulses traveling between two measuring sites, used as a marker of arterial stiffness and an important indicator for cardiovascular disease. Methods: A PWV measurement system, which offers a non-invasive, simple method of measurement, and simultaneous recording of six signlas(ECG, PCG and four pulse waves from carotid, femoral, radial and dorsalis pedis arteries) was developed. Seventeen healthy subjects with a mean age of 33 years(22 to 52) without any cardiovascular disease were participated for the experiment. Two observers(A and B) performed two consecutive measurements from the same subject in a random order. For the evaluation of stability and accuracy of the PWV measurement system, reproducibility of PWV from between-observer were also evaluated. Results: PWV $values(Mean{\pm}SD)$ measured by A were $7.07{\pm}1.48m/s$, $8.43{\pm}1.14m/s$ , $8.09{\pm}0.98m/s$ for aorta, arm, and leg, respectively. The values obtained from B were $6.76{\pm}1.00m/s$, $7.97{\pm}0.80m/s$, and $7.97{\pm}0.72m/s$ for aorta, arm, and leg, respectively. Between-observer $differences(mean{\pm}SEM)$ from the aorta, arm and leg were $0.14{\pm}0.15m/s$, $0.18{\pm}0.10m/s$ and $0.07{\pm}0.10m/s$. Reproducibility coefficients(2SD) from the aorta, arm, and leg were 0.62m/s, 0.84m/s and 0.86m/s. Correlation coefficients were significantly higher in aortic PWV, 0.93, compared to the coefficients for arm and leg. Coefficient of variance which reflects the reproducibility of the system ranged from $4.4{\sim}5.8%$ in all regional PWV. , Conclusion: Reproducibility of PWV in the study shows that the developed system has reliable and reproducible characteristics. The PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis and results with high reproducibility. Results of the PWV measurement system could contribute to various clinical applications in the future.

  • PDF

Analysis of Anesthetic Consultation in Elective Surgical Patients (정규수술환자 중 마취통증의학과로 협진 의뢰한 환자의 분석)

  • Ha, Ji-Won;Chung, Sung-Su
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.10 no.1
    • /
    • pp.7-12
    • /
    • 2010
  • Background: This study was carried out to contribute to effective management of operated patients by analyzing cooperative details about patients who were taken elective operation and consulted to the department of anesthesiology. Patients and Methods: One thousand patients who have been consulted to department of Anesthesiology, Chonnam National University Hospital from 2008. November to 2009. March were analyzed. The gender, age, cooperative departments, cooperative reason, the number of cancelled cases and cancelled reason were evaluated. Results: Among 1000 patients, there were 470 females and 530 males. After adjusting for age, middle-aged people which range 45 to 64 year-old are 39.9% and over 65 year-old people are 30.3%. Cooperative department is distributed to orthopedics which is highest occupying 20.6%, neurosurgery, otorhinolaryngology, obstetrics and gynecology in order. Dentistry occupied 2.0%. By specifying reasons of cooperation, cardiovascular diseases distribute to 38.4% which is the highest, the respiratory diseases, 17.5% and the endocrine diseases including diabetes 13.2%. Arranging details, hypertension is 23.9%, ECG abnormality 14.5%, chronic bronchitis in chest radiographic interpretation 14.2%. Of 1,000 consulted patients, delayed or cancelled cases are 58. And the reasons were 26 cases of need of appropriate the blood-sugar level. 26 cases needed appropriate treatment for comorbidities and others 6. Conclusion: Thoroughly evaluating patients before operation and maintenace of active cooperative system between operative department and anesthesiology department can contribute to reduction of cancellation rate and effective management of both hospitalizing and operating rooms.