• Title/Summary/Keyword: ECG Analysis

Search Result 376, Processing Time 0.024 seconds

Smart Device based ECG Sensing IoT Applications (스마트 디바이스 기반 ECG 감지 IoT 응용 서비스에 관한 연구)

  • Mariappan, Vinayagam;Lee, Seungyoun;Lee, Junghoon;Lee, Juyoung;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.3
    • /
    • pp.18-23
    • /
    • 2016
  • Internet of things (IoT) is revolutionizing in the patient-Centered medical monitoring and management by authorizing the Smartphone application and data analysis with medical centers. The network connectivity is basic requirement to collect the observed human beings' health information from Smartphone to monitor the health from IoT medical devices in personal healthcare. The IoT environment built in Smartphone is very effective and does not demand infrastructure. This paper presents the smart phone deployed personal IoT architecture for Non-Invasive ECG Capturing. The adaptable IoT medical device cum Gateway is used for personal healthcare with big data storage on cloud configuration. In this approach, the Smartphone camera based imaging technique used to extract the personal ECG waveform and forward it to the cloud based big data storage connectivity using IoT architecture. Elaborated algorithm allows for efficient ECG registration directly from face image captured from Smartphone or Tablet camera. The profound technique may have an exceptional value in monitoring personal healthcare after adequate enhancements are introduced.

Development of Holter ECG Monitor with Improved ECG R-peak Detection Accuracy (R 피크 검출 정확도를 개선한 홀터 심전도 모니터의 개발)

  • Junghyeon Choi;Minho Kang;Junho Park;Keekoo Kwon;Taewuk Bae;Jun-Mo Park
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.2
    • /
    • pp.62-69
    • /
    • 2022
  • An electrocardiogram (ECG) is one of the most important biosignals, and in particular, continuous ECG monitoring is very important in patients with arrhythmia. There are many different types of arrhythmia (sinus node, sinus tachycardia, atrial premature beat (APB), and ventricular fibrillation) depending on the cause, and continuous ECG monitoring during daily life is very important for early diagnosis of arrhythmias and setting treatment directions. The ECG signal of arrhythmia patients is very unstable, and it is difficult to detect the R-peak point, which is a key feature for automatic arrhythmias detection. In this study, we develped a continuous measuring Holter ECG monitoring device and software for analysis and confirmed the utility of R-peak of the ECG signal with MIT-BIH arrhythmia database. In future studies, it needs the validation of algorithms and clinical data for morphological classification and prediction of arrhythmias due to various etiologies.

ECG based Personal Authentication using Principal Component Analysis (주성분 분석기법을 이용한 심전도 기반 개인인증)

  • Cho, Ju-Hee;Cho, Byeong-Jun;Lee, Dae-Jong;Chun, Myung-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.258-262
    • /
    • 2017
  • The PCA(Principal Component Analysis) algorithm is widely used as a technique of expressing the eigenvectors of the covariance matrix that best represents the characteristics of the data and reducing the high dimensional vector to a low dimensional vector. In this paper, we have developed a personal authentication method based on ECG using principal component analysis. The proposed method showed excellent recognition performance of 98.2 [%] when it was experimented using electrocardiogram data obtained at weekly intervals. Therefore, it can be seen that it is useful for personal authentication by reducing the dimension without changing the information on the variability and the correlation set variable existing in the electrocardiogram data by using the principal component analysis technique.

Design and Distortion Analysis of Digital Filters for ECG Waveforms Detection (EOG 신호의 파형 감지를 위한 디지털 필터의 설계 및 왜형 해석)

  • Nam, Hyun-Do;Ahn, Dong-Jun;Lee, Cheol-Heui
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.70-73
    • /
    • 1993
  • Design as well as Distortion analysis of signal conditioning filters is very useful for practical applications. Distortion analysis of digital filters for wave forms detection in ECG signals is presented. Several band pass and band reject filters are designed for the analysis. Computer simulations are performed to compare the distortions of the Butterworth type filters and linear phase optimal FIR filters which are widely used for ECG signal processing.

  • PDF

Development of an Evaluation Method for a Driver's Cognitive Workload Using ECG Signal (ECG 기반의 운전자별 인지 부하 평가 방법 개발)

  • Hong, Wongi;Lee, Wonsup;Jung, Kihyo;Lee, Baekhee;Park, Jangwoon;Park, Suwan;Park, Yunsuk;Son, Joonwoo;Park, Seikwon;You, Heecheon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.3
    • /
    • pp.325-332
    • /
    • 2014
  • High cognitive workload decreases a driver's ability of judgement and response in traffic situation and could result in a traffic accident. Electrocardiography (ECG) has been used for evaluation of drivers' cognitive workload; however, individual differences in ECG response corresponding to cognitive workload have not been fully considered. The present study developed an evaluation method of individual driver's cognitive workload based on ECG data, and evaluated its usefulness through an experiment in a driving simulator. The evaluation method developed by the present study determined the optimal ECG evaluation condition for individual participant by analysis of area under the receiver operating characteristic curve (AUC) for various conditions (total number of conditions = 144) in terms of four aspects (ECG measure, window span, update rate, and workload level). AUC analysis on the various conditions showed that the optimal ECG evaluation condition for each participant was significantly different. In addition, the optimal ECG evaluation condition could accurately detect changes in cognitive workload for 47% of the total participants (n = 15). The evaluation method proposed in the present study can be utilized in the evaluation of individual driver's cognitive workload for an intelligent vehicle.

A Study of ECG Pattern Classification of Using Syntactic Pattern Recognition (신택틱 패턴 인식 알고리즘에 의한 심전도 신호의 패턴 분류에 관한 연구)

  • 남승우;이명호
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.267-276
    • /
    • 1991
  • This paper describes syntactic pattern recognition algorithm for pattern recognition and diagnostic parameter extraction of ECG signal. ECG signal which is represented linguistic string is evaluated by pattern grammar and its interpreter-LALR(1) parser for pattern recognition. The proposed pattern grammar performs syntactic analysis and semantic evaluation simultaneously. The performance of proposed algorithm has been evaluated using CSE database.

  • PDF

A Study for The Discrimination of Visual Emotions Using Heart Rate Variability (심박변화율(HRV)에 의한 시각감성의 구분에 대한 연구)

  • 오상훈;황민철;임재중
    • Proceedings of the ESK Conference
    • /
    • 1997.10a
    • /
    • pp.473-476
    • /
    • 1997
  • Human visual emotion were investigated by analyzing HRV from ECG signals, which were varied by the visual stimuli. In this paper, twelve university students experienced visual emotion by pictures from IAPS. ECG and subjective rating were obtained for human emotion evaluation. For determination of HRV, ECG was extracted into HF and LF via power spectrum analysis. The results showed that HRV is good for discrimination between positive and negative emotions.

  • PDF

Implementation of Wearable Heart Activity Monitoring System having Modified Bipolar Electrode and Correlation Analysis with Clinical Electrocardiograph(ECG) (수정된 바이폴라 전극을 갖는 착용형 심장활동 모니터링 시스템 구현 및 임상 심전도와의 상관관계 분석)

  • Lee, Kang-Hwi;Lee, Jeong-Whan;Lee, Young-Jae;Kim, Kyeong-Seop;Yang, Heui-Koung;Shin, Kun-Su;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1102-1108
    • /
    • 2008
  • Wearable physiological signal monitoring systems are regarded as an important sensing unit platforms in ubiquitous/mobile healthcare application. In this paper, we suggested the modified bipolar electrodes implemented on the portable heart activity monitoring system, which minimized the distance of electrodes formed on a attachable pad. The proposed electrode configuration is useful in mobile measurement environments, but has a disadvantage of reduced amplitude of the heart action potential. In order to overcome the shortcoming of the suggested electrode configuration, we implemented the amplifying circuit to increase the signal-gain and decrease the artifacts. For evaluations, we analyzed the specificity of measured cardiography using the proposed electrodes through the comparing of heart activity monitoring system with standard clinical ECG(lead2) by pearson correlation coefficients. The result showed that the average correlation coefficient is $0.903{\pm}0.036,\;0.873{\pm}0.072$ at V3, V4 chest lead position, respectively. Thus, the modified bipolar electrode is quite suitable to monitor the electrical activity of the heart in the situation of the mobile environment, and could be considered having high similarity with standard clinical ECG.

Comparative Analysis of Coding Performance of Several ECG Compression Methods (ECG 압축 방법들의 코딩 성능 비교 분석)

  • Jang, Seung-Jin;Song, Sang-Ha;Yun, Yeong-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.137-138
    • /
    • 2008
  • 수많은 방식의 ECG 압축 코딩 알고리즘이 개발되어왔고 현재도 개발 중이지만 각자의 알고리즘의 성능에 유리한 특정 데이터만을 분석하고 압축율이 다름으로 인해 다른 알고리즘과의 성능 비교를 객관화하고 있지 못하였다. 본 연구에서는 기존의 MIT-BIH에서 제공하는 ECG 신호와 달리 시뮬레이션된 ECG 신호를 기반으로 각각의 알고리즘에 대한 성능비교를 하여 ECG신호의 특성에 따른 코딩 알고리즘의 압축율 및 평균 오차 에러의 정도를 분석비교하였다. 비교 대상 알고리즘으로는 상용화되어 널리 사용되는 Delta 코팅 방식의 문턱치를 갖는 Discrete Pulse Code Modulation과 Discrete Cosine Transform, Lifting Wavelet Transform과 Wavelet 기반 Linear Prediction 4가지 알고리즘을 대상으로 분석하였다. Compression Ratio (CR)을 2,4로 고정하고 Percentage of Root-mean-square difference (PDR)를 분석 한 결과, EMG 잡음의 진폭변 화에는 0.1mV이하의 경우 OCT, Wavelet Lifiting Transform이 낮은 PDR을 보였고, 01.mV이상의 경우 Wavelet based Linear Prediction (WLP)이 낮은 PDR을 보였다. Heart Rate의 간격에 변화를 주어 불규칙성이 있는 경우 WLP가 가장 안좋은 PDR 결과를 보였으며, DCT가 가장 낮고 안정된 PDR 결과를 보였다. DPCM은 노이즈와 진폭간격의 변화에 상관없이 압축율에 의해 크게 PDR 성능 결과가 변화함을 나타내었다.

  • PDF

Real Time Drowsiness Detection by a WSN based Wearable ECG Measurement System

  • Takalokastari, Tiina;Jung, Sang-Joong;Lee, Duk-Dong;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.382-387
    • /
    • 2011
  • Whether a person is feeling sleepy or reasonably awake is important safety information in many areas, such as humans operating in traffic or in heavy industry. The changes of body signals have been mostly researched by looking at electroencephalogram(EEG) signals but more and more other medical signals are being examined. In our study, an electrocardiogram(ECG) signal is measured at a sampling rate of 100 Hz and used to try to distinguish the possible differences in signal between the two states: awake and drowsy. Practical tests are conducted using a wireless sensor node connected to a wearable ECG sensor, and an ECG signal is transmitted wirelessly to a base station connected to a server PC. Through the QRS complex in the ECG analysis it is possible to obtain much information that is helpful for diagnosing different types of cardiovascular disease. A program is made with MATLAB for digital signal filtering and graphing as well as recognizing the parts of the QRS complex within the signal. Drowsiness detection is performed by evaluating the R peaks, R-R interval, interval between R and S peaks and the duration of the QRS complex..