• Title/Summary/Keyword: ECD

Search Result 498, Processing Time 0.031 seconds

Analytical method of the polychlorinated biphenyls in soil using GC/ECD and GC/MS (GC/ECD 및 GC/MS을 이용한 토양 중 PCBs 분석방법 고찰)

  • Kim, Tae-Seung;Shin, Sun-Kyoung;Yoon, Jeong-Ki;Kim, Jong-Ha;Kim, Hyoung Seop;Lee, Jeong Ah
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.91-108
    • /
    • 2007
  • This study was investigated both the Korean official soil test method and the international various methods for PCBs in soil sample. The analytical guideline of PCBs in contaminated soil were proposed based on the official soil test methods by discussing the extraction, column cleanup, instrumental conditions, quantification methods of peak matching and individual isomers. The total 28 soil samples were selected by consideration of PCBs-contamination, land use etc., and then analyzed using gas chromatography/electron capture detection (GC/ECD) and gas chromatography/mass spectrometry(GC/MS). In this study, the PCBs were not detected as peak matching method using GC/ECD, but PCBs detected $0.002{\sim}0.487{\mu}g/kg$ using GC/MS in background concentrations.

Characteristics of an electrochromic ECD (electro-chromic device) film in applications for smart windows with a 4-layer structure, a thickness of 0.5 mm (0.5 mm 이내의 두께를 갖는 4층 구조의 스마트 윈도우에 적용되는 전기변색 ECD(electro-chromic device) 필름 제조 및 특성)

  • Nam Il Kim;Geug Tae Kim
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.34 no.1
    • /
    • pp.16-21
    • /
    • 2024
  • Using electrochromic devices (ECD), smart window films that can change the colors from tinted state into transparent state by applying an external voltage were manufactured. Polyethylene terephthalate (PET) film was used as a substrate instead of conventional glass, and ECD modules having a total thickness of about 50 ㎛ were manufactured by sequentially introducing an ITO/Ag/ITO electrode layer, a WO3/TIC2 organic discoloration layer, and a Nafion fluorine electrolyte layer. Through a series of sputtering, bar coating, and thermal compression processes, a large scale smart window with a horizontal and vertical length of more than 80 mm was manufactured. When DC 3.5 V was applied, the transmittance decreased from 54 % to 24 % and moreover the color change could be confirmed even with the naked eye. Reversible color change capability at low external voltage implies that external sunlight can be selectively blocked which is effective in terms of energy saving.

Determination of Quintozene Residues in Agricultural Commodities Using GC-ECD/MS (GC-ECD/MS를 이용한 농산물 중 Quintozene의 잔류분석)

  • Ahn, Kyung-Geun;Kim, Gyeong-Ha;Kim, Gi-Ppeum;Hwang, Young-Sun;Hong, Seung-Beom;Lee, Young Deuk;Choung, Myoung-Gun
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.195-203
    • /
    • 2015
  • Quintozene, pentachloronitrobenzene (PCNB) is a contact fungicide for control of soilborne phytopathogenic fungi during cultivation of diverse crops. It was introduced to agricultural use around 1930's as a substitute for mercurial disinfectants. Although quintozene had been first registered in Korea on 1969. However, now it was banned to use due to its high residue levels in selected harvest products. Also, high possibility is expected that the residue may be contained in imported agricultural commodities as it is still used widely over the world. Therefore, this study was conducted to establish a determination method for quintozene residue in crops using GC/ECD/MS. Quintozene residue was extracted with acetonitrile from representative samples of five raw products which comprised hulled rice, soybean, Kimchi cabbage, green pepper, and apple. The extract was diluted with saline water, and n-hexane partition was followed to recover quintozene from the aqueous phase. Florisil column chromatography was additionally employed for final clean up of the extract. The quintozene was quantitated by GLC with ECD, using a DB-1 capillary column. The crops were fortified with quintozene at 3 levels per crop. Mean recoveries ranged from 79.9% to 102.7% in five representative agricultural commodities. The coefficients of variation were less than 4.3%. Quantitative limit of quintozene was 0.004 mg/kg in representative five crop samples. A GC/MS with selected-ion monitoring was also provided to confirm the suspected residue. Therefore, this analytical method was reproducible and sensitive enough to determine the residue of quintozene in agricultural commodities.

Multi-residue Analysis of Pesticides using GC-TOF/MS, ECD, NPD with QuEChERS Sample Preparation (QuEChERS 전처리법과 GC-TOF/MS, ECD, NPD를 이용한 잔류농약 다성분분석)

  • Park, Jungwook;Kim, Aekyung;Kim, Jongpil;Lee, Hyanghee;Park, Duckwoong;Moon, Sujin;Ha, Dongryong;Kim, Eunsun;Seo, Kyewon
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.278-295
    • /
    • 2014
  • Fast and accurate multi-residue pesticides inspecting method needs in Agro-Fishery Products Inspection Center. So, We tried to seek the optimum method using GC-TOF/MS, GC-ECD, GC-NPD after QuEChERS sample preparation. In GC-TOF/MS, 138 kinds of pesticide were spiked at 0.3 and $0.5{\mu}g/g$for the identification and quantification in lettuce sample. Recoveries of 77 pesticides were between 70 and 130% with RSD (relative standard deviation lower than 20% at $0.3{\mu}g/g$. In GC-ECD, NPD, 146 kinds of pesticide were spiked for the identification and quantification in lettuce. Recoveries of 61 species were between 70 and 130% with lower than 20%. These results indicated that GC-TOF/MS, GC-ECD, NPD analysis with the QuEChERS sample preparation can be partly applied to multi-residue pesticides in vegetables.

Brain SPECT Using $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD in Subacute Cerebral Infarction: Case Report (아급성 뇌경색 환자에서 $^{99m}Tc$-HMPAO 및 $^{99m}Tc$-ECD 뇌 SPECT: 증례보고)

  • Ahn, Byeong-Cheol;Lee, Dong-Soo;Yoon, Byung-Woo;So, Young;Jung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.570-575
    • /
    • 1996
  • For brain perfusion SPECT imaging, $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD are commonly used. Although these two tracers usually show similar distribution, it is well known that discrepant finding might be noted between $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD imaging in some conditions. Luxury perfusion(perfusion/metabolism mismatch) is one of the examples and could be observed in subacute cerebral infarction. We report a case of subacute cerebral infarction that revealed luxury perfusion. Increased perfusion was found in $^{99m}Tc$-HMPAO SPECT and perfusion defect was found in $^{99m}Tc$-ECD SPECT. We found large area of mismatch with a consecutive acquisition-subtraction method. Crossed cerebellar diaschisis was observed in both SPECT images.

  • PDF

A Case of Erdheim-Chester Disease Who Has Policythemia Vera (진성 적혈구증다증 환자에서 발현한 Erdheim-Chester Disease 1예)

  • Kim, Ji Eun;Lee, Hyun Jeong;Rhee, Chin Kook;Yoon, Hyung Kyu;Song, Jeong Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.3
    • /
    • pp.224-229
    • /
    • 2008
  • Erdheim-Chester disease (ECD) is a rare disease that is characterized by multi-organ involvement of foamy histiocytes. It causes systemic inflammation, and also demonstrates various clinical manifestations and has a poor prognosis. We encountered a case of ECD in a patient that had been treated for underlying polycythemia vera. As far as we know, this is the first reported case worldwide where ECD developed in association with polycythemia vera. A 59-year-old man visited our hospital due to pleuric pain at the right side of the chest. Pleural tissue that was obtained following a thoracoscopic biopsy showed non-Langerhan's cell histiocytosis, suggesting the presence of ECD. The histiocytes stained positively for CD68, but were negative for S-100 and CD1a. The patient also complained of pain at both hips and the right shoulder area. An X-ray and magnetic resonance image demonstrated that the lesion showed sclerosis and osteolysis in both the proximal femur and right humerus. Treatment was started with predinisolone, and subsequently cyclophosphamide was added. ECD is a very rare multi-systemic disease, and its cause and therapeutic options have not yet been defined. ECD has a poor prognosis. Therefore, we believe that additional case studies are needed prior to the determination of a novel therapy for ECD.

Electrochemical properties of ECD using Titanate nanotube (Titanate nanotube를 이용한 ECD의 전기화학적 특성연구)

  • Oh, Hyo-Jin;Lee, Nam-Hee;Lee, Dae-Girl;Yun, Yeong-Ung;Hwang, Jong-Sun;Kim, Sun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2119_2120
    • /
    • 2009
  • 전압을 인가하였을 때 전계방향에 의해 가역적으로 색이 변화하는 현상을 전기변색(electrochromism)이라고 한다. 이러한 전기채색현상을 보이는 물질을 전기채색물질(electrochromism materials)이라고 하며, 전기채색 물질에 의한 소자를 전기채색소자(electrochromism device : ECD)라고 한다. 전기채색현상은 투과율(transmittance), 반사율(reflectance)의 가역적이며 가시적인 변화이고, 전기화학적인 산화환원 반응과 관련이 있다. 따라서 본 연구에서는 Titanate nanotube(TNT)를 제조하고 전기변색소자(ECD)에 응용하였다. SEM, XRD, UV-Vis등을 이용하여 재료학적 분석을 시행하였으며, 전기화학적 테스트로 cyclic voltammetry를 측정 하였다. 그 결과 TNT 분말은 직경 약 20~30 nm, 길이 약 500~600 nm 의 입자형상을 나타내었으며, X-선 회절시험결과 $H_2Ti_2O_5{\cdot}H_2O$의 층상구조를 나타내었다. 제조된 막은 FTO glass 위에 PEI/(TNT/TBAOH)$_{n-1}$/PDDA의 순으로 코팅되었다. 전기화학적 테스트를 위하여 2전극 시스템을 제작하였으며, 여러 종류의 액체 전해질을 제작하여 cycle voltammetry를 시행하였다. 그 결과, 각각의 전해질에서 "-"영역의 산화환원전위 피크가 뚜렷하게 나타났으며, 짙은 갈색으로의 채색현상을 나타냈다. 본 연구의 결과로서 TNT 박막을 이용한 ECD은 광조절 유리로서 뿐만 아니라, 여러 전기채색 디바이스에 응용될 것으로 사료된다.

  • PDF

Screening procedure for organochlorinated pesticide residues in meat fat using a matrix solid phase dispersion(MSPD) extraction and GC/ECD (MSPD법과 GC/ECD를 이용한 식육중의 잔류농약 분석)

  • 백미순;이영철;박병옥;김창수;박유순
    • Korean Journal of Veterinary Service
    • /
    • v.22 no.1
    • /
    • pp.15-23
    • /
    • 1999
  • A multiresidue, simple and rapid isolation technique known as matrix-solid phase dispersoin (MSPD) for the extraction and quantitative gas chromatographic/electron capture detection (GC/ECD) determination of 14 organochlorinated pesticides($\alpha$-BHC, ($\beta$-BHC, ($\gamma$-BHC, aldrin, dieldrin, endrin, heptachlor, ($\alpha$-endosulfan, ($\beta$-endosulfan, endosulfan sulfate, p,p'-DDE, o,p'-DDD, p,p'-DDD, p,p'-DDT) from meat fats. The 14 pesticide were fortified into meat fat(0.5g) and blend with 2g $C_{18}$, $C_{18}$meat fat matrix blend and 2g activated florisil comprise an extraction column from which the pesticides are eluted by adding 8ml acetonitrile. Then 2${\mu}\ell$ of the eluate is analyzed by GC/ECD. Unfortified blank controls are tested similarly. The eluate contained all the pesticide analytes and was free of interfering coextractants. Recovery rate(31.3-500ng/g) were ranged from 80$\pm$4% to 97$\pm$4%. Any organochlorinated pesticides were not detected in 120 samples of beef and pork collected from slaughter houses in Kyeonggi province.

  • PDF

GC/MS and GC/ECD Analysis of Residual Pesticides in Herbal drugs (GC/MS와 GC/ECD를 이용한 한약재 중 잔류 농약의 분석)

  • Kim, Ho-Kyoung;Park, So-Yeon;Ko, Byoung-Seob
    • The Journal of Korean Medicine
    • /
    • v.20 no.1 s.37
    • /
    • pp.44-51
    • /
    • 1999
  • Analysis of residual pesticides in herbal drugs was performed by GC-ECD and GC-MS. Especially, selected ion monitoring(SIM) technique was applied to increase the GC/MS sensitivity. Analysis of residual pesticides was determined sensitivity and selectively without any internal standard by setting the SIM technique to their characteristic fragments for quantitation ion and confirmation ion. The combination of two detector, GC-ECD and MS-SIM technique, is abailable for determining a multiclass residual pesticides in herbal drugs. The average recoveries through the method were $65.9%{\sim}99.7%$ in herbal drugs. The data of gas chromatographic analysis was compared with the limits of residual pesticides in herbal drugs and agricultural foods. 4. 4-DDT was detected above the limits to the residual pesticides in herbal drugs. Diazinon and EPN were detected, but the limits of residual pesticides were less than that of agricultural foods.

  • PDF

Simultaneous Analytical Method of Organochlorine and Pyrethroid Pesticides using GC(ECD) (GC-ECD를 이용한 유기염소계 밑 Pyrethroid계 농약 동시 분석법)

  • 김우성;이선화;김재이;정지윤;이명자;박영채;이영자;정성욱;이봉헌
    • Journal of Environmental Science International
    • /
    • v.12 no.4
    • /
    • pp.477-480
    • /
    • 2003
  • Pesticides were extracted from samples with 70% acetone and methylene chloride in order, and then cleaned up via open-column chromatography apparatus packed with florisil, and finally analyzed simultaneously the organochlorine and pyrethroid pesticides using GC(ECD). An ultra-2 fused silica capillary column was used to separate and identify the products. The resolution between the last isomeric peak of cypermethrin(59.987min) and the first isomeric peak of flucythrinate(60.043min) was not satisfactory. The last isomeric peak of fenvalerate(62.344min) and the first isomeric peak of fluvalinate(62.397min) were overlapped. Recoveries of soybean sample fer the most pesticides were 73.3% to 102.4%. Detection limits were between 0.004 and 0.063 ${\mu}$g/mg when this method was used.