• Title/Summary/Keyword: ECC 영구거푸집

Search Result 4, Processing Time 0.018 seconds

Fire Resistance Properties of High Strength Concrete Column using ECC Permanent Form (ECC 영구 거푸집을 활용한 고강도콘크리트 기둥부재의 내화특성)

  • Kim, Yong-Ro;Song, Young-Chan;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.957-960
    • /
    • 2008
  • In this study, it was investigated fire resistance properties of high strength concrete column using Engineered Cementitious Composites(ECC) permanent form as a countermeasure for explosive spalling of concrete on fire. As a test result, it was appeared that ECC permanent form is available as fire resistance method of high strength concrete if it is developed manufacturing technique and scheme for application controlling heat penetration through interface of permanent form and high strength concrete, and setting up mix proportion and thickness of ECC.

  • PDF

A Development and Characterization of Refractory Panel (내화패널의 개발과 특성에 관한 연구)

  • Kim, Dong-Joon;Kwon, Young-Jin;Kim, Yong-Ro;Han, Byung-Chan;Kim, Jae-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.61-66
    • /
    • 2009
  • 최근 초고층 건축물 등에 적용되는 고강도콘크리트의 내화성능에 대한 문제점이 제기됨에 따라 국토해양부에서는 고강도콘크리트 내화성능 관리 기준을 고시한 바 있으며, 건설업계에서도 이에 대응하기 위해 다양한 기술 검토가 이루어지고 있다. 본 연구에서는 고강도콘크리트의 취약점으로 제기되고 있는 화재시의 폭렬문제에 대한 대응방안으로서 기존 연구를 통해 내화성능이 우수한 것으로 보고되고 있는 ECC 를 영구거푸집으로 활용한 고강도콘크리트의 내화성능을 검토하였다. ECC 영구거푸집을 활용한 고강도콘크리트 기둥부재의 내화성능 검토 결과, 영구거푸집과 고강도콘크리트 계면으로의 열 침투를 제어할 수 있도록 부재 생산 및 구축 방안을 검토하고, ECC의 적정 배합 및 두께를 확보한다면 고강도콘크리트의 내화성능 확보기술로서의 활용이 가능할 것으로 판단된다. 또한, 내화성 영구거푸집으로서의 단순 활용 방안 이외에 ECC의 우수한 물리적 성능을 활용하여 구조성능을 분담할 수 있는 방안으로의 지속적 검토가 필요할 것으로 판단된다.

  • PDF

An Experimental Study on the Fire Resistance and Mechanical Properties of ECC Permanent Form (ECC 영구거푸집의 내화성능 및 역학적 특성에 관한 실험적 연구)

  • Kim, Yong-Ro;Song, Young-Chan;Oh, Jae-Keun;Kim, Jae-Hwan;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05c
    • /
    • pp.75-78
    • /
    • 2009
  • It was investigated fire resistance properties and mechanical properties of high strength concrete column using ECC(Engineered Cementitious Composites) permanent form by KS F 2257 Methods of fire resistance test for elements of building construction and compression test for application of precast concrete column method of high rise building in this study. As a test result, it was appeared that ECC permanent form is available as fire resistance method of high strength concrete and new precast concrete construction method for facilitating construction of high rise building.

  • PDF

An Experimental Study on the Mechanical and Durability Properties of Ductile Cement Panel Used Vacuum Extrusion Molding (진공압출성형 고인성 시멘트 패널의 역학 및 내구특성에 관한 실험적 연구)

  • Rho, Hyoung-Nam;Lee, Jong-Suk;Han, Byung-Chan;Kwon, Young-Jin;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.473-476
    • /
    • 2008
  • Due to the pursuit of high function and international price increase in the field of construction, the application of the secondary product using cement is on the increase gradually in the construction industry in the pursuit of economic cost reduction by the shortening of the construction time like Expediting and the dry construction method at the same time. However, it is in very urgent situation of measures to improve the structural performance or durable performance because it is limited for use in terms of panel in interior exterior building or functional repair reinforce as yet. Accordingly, this study is to investigate applicability of permanent Formwork like mould with the structural performance or excellent durable performance in the field of construction, and to derive optimum mixture in the performance and quality of manufacture. As a result of analysis comparison with the dynamic and durable properties of vacuum extrusion molding high toughness cement panel according to the mixture of four conditions, this study has found that the test body of mixing ECC-DP3 using small filler and large granulated blast furnace slag and powder flame retardant had excellent relative hardness and bending stress strain. The durable performance has shown excellent tendency by the decrease of porosity and enhancement of water-tightness.