• Title/Summary/Keyword: E.coil

Search Result 311, Processing Time 0.034 seconds

Design of Implantable Middle Ear Hearing Aids Using an Electromagnetic Transducer (전자 트랜스듀서 방식에 의한 청각보조용 이식형 인공중이 시스템 설계)

  • Cho, Jin-Ho;Song, Byung-Seop;Kim, Myoung-Nam;Won, Chul-Ho;Park, Se-Kwang;Lee, Sang-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.466-475
    • /
    • 1997
  • In this paper, an implantable middle ear hearing aids using an electromagnetic transducer which consists of a tiny coil and a magnet is designed, and objective design method to implement a vibrator of the electromagnetic type transducer is proposed. Sound characteristic of the electromagnetic type vibrator is excellent but power transfer rate is lower than that of a ceramic type. To improve power transfer efficiency of system, external and inner part of a middle ear system is designed using FM transmission method. We implemented an experimental set of the designed transducer, inner part, and outer part. Then, we measured vibration characteristics of a metal strip and a temporal bone of a dead body. As the results, we confirmed the advantage of FM method and showed that designed transducer could effectively transmit vibration of amplified input sound pressure to ossicle.

  • PDF

AC loss dependency on the arrangement of the HTS wires in the current limiting module for SFCL (초전도 한류모듈 내 고온초전도 선재 배치에 따른 교류손실 변화)

  • Kim, W.S.;Yang, S.E.;Lee, J.Y.;Kim, H.;Yu, S.D.;Hyun, O.B.;Kim, H.R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.9-12
    • /
    • 2012
  • Usually, the AC loss from the superconducting element of an SFCL due to the load current is very small because it is composed of the combination of bifilar windings with very small reactance. Although the AC loss is small enough, we should be albe to predict for the design and control of the cryogenic system. In fact, an SFCL for the transmission voltage class may not generate ignorable AC loss because of the inevitable space between the HTS wires for the high voltage insulation and cryogenic efficiency. To measure the AC loss dependency on the space between the 2G HTS wires with the width of 4.4 mm, we prepared an experimental setup which could adjust the distance between the wires. We used two 500-mm length HTS wires in parallel and applied the current in the opposite direction for each wire to simulate a part of a current limiting module for a high voltage SFCL. We also put two couples of voltage taps at the ends of each wire and a cancel coil in the voltage measurement circuit to compensate the reactive component from the voltage taps. In this condition, we varied the distance between the wires to investigate the change of the transport current loss. A similar experimental study with HTS wire with the width of 12 mm is now in progress.

A HISTOLOGIC STUDY OF PULPAL REACTION AFTER EXPERIMENTAL TOOTH MOVEMENT IN RATS (백서구치의 실험적 치아이동후 치수조직 변화에 관한 조직학적 연구)

  • Jin, Keun Ho;Hong, Sung Joon
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.635-656
    • /
    • 1991
  • It was the aim of this investigation to evaluate some histologic aspect of rat pulp tissue after it had been compromised by an experimental orthodontic force. Experimental animals of thirty five Spraque-Dawley rats were employed. The first upper molars had been successively mesial moved (initial load 100 gr.) with a closed coil spring during 21 days. The experimental periods were set on immediate, 1 day, 1 week, 2 weeks, 3 weeks, 4 weeks following retention time. On each experimental period, the rats were killed and prepared for the light microscopy. After prepared with H/E stain and Gomori's one-step trichrome stain, the specimens were analyzed with evaluation criteria which were adopted in this study. The result may be summarized as follows; 1. The main pulp changes due to experimental orthodontic force included vacuolization of odontoblastic layer, circulation disturbance, root resorption, reduced pulp collagenous fiber density and mean cell count of pulp fibroblast in the immediate group. 2. The pulp tissue changes were revealed reversible because the relieved pulp tissues from experimental orthodontic force were recovered rapidly in each evaluation criteria during retention periods. 3. Compared with normal control group, pulp collagenous fiber density were decreased in immediated group (p < 0.01), but increased in each retention groups. These seem to suggest that the pulp tissues were aged after experimental orthodontic force conditions. 4. Compared with normal control group, mean cell counts of pulp fibroblasts were decreased in immediate group (p < 0.05), but increased continuous in each retention groups. These seem to indicate that the pulp tissues were highly regenerative after experimental orthodontic force conditions. 5. Compared with normal control group, root resorptions occurred in all immediate specimens (p < 0.01) and they were healed in each retention periods, but often observed in 4 weeks retention group. These seem to indicate that root resorptions were recovered slowly after experimental orthodontic force conditions.

  • PDF

Crystal Structure of Hypothetical Fructose-Specific EIIB from Escherichia coli

  • Park, Jimin;Kim, Mi-Sun;Joo, Keehyung;Jhon, Gil-Ja;Berry, Edward A.;Lee, Jooyoung;Shin, Dong Hae
    • Molecules and Cells
    • /
    • v.39 no.6
    • /
    • pp.495-500
    • /
    • 2016
  • We have solved the crystal structure of a predicted fructose-specific enzyme $IIB^{fruc}$ from Escherichia coli ($EcEIIB^{fruc}$) involved in the phosphoenolpyruvate-carbohydrate phosphotransferase system transferring carbohydrates across the cytoplasmic membrane. $EcEIIB^{fruc}$ belongs to a sequence family with more than 5,000 sequence homologues with 25-99% amino-acid sequence identity. It reveals a conventional Rossmann-like ${\alpha}-{\beta}-{\alpha}$ sandwich fold with a unique ${\beta}$-sheet topology. Its C-terminus is longer than its closest relatives and forms an additional ${\beta}$-strand whereas the shorter C-terminus is random coil in the relatives. Interestingly, its core structure is similar to that of enzyme $IIB^{cellobiose}$ from E. coli ($EcIIB^{cel}$) transferring a phosphate moiety. In the active site of the closest $EcEIIB^{fruc}$ homologues, a unique motif CXXGXAHT comprising a P-loop like architecture including a histidine residue is found. The conserved cysteine on this loop may be deprotonated to act as a nucleophile similar to that of $EcIIB^{cel}$. The conserved histidine residue is presumed to bind the negatively charged phosphate. Therefore, we propose that the catalytic mechanism of $EcEIIB^{fruc}$ is similar to that of $EcIIB^{cel}$ transferring phosphoryl moiety to a specific carbohydrate.

The Study on the Superconducting MRI Magnet of 68 cm in Room Temperature Bore (68 cm 상온 보아를 갖는 MRI용 초전도마그네트에 관한 연구)

  • Jin, H.B.;Oh, B.H.;Cho, J.W.;Oh, S.S.;Kwon, Y.K.;Ha, D.W.;Lee, E.Y.;Kim, H.J.;Kim, O.K.;Choi, B.J.;Ryu, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.142-146
    • /
    • 1996
  • In this paper, we present the main research results on the 2 Tesla class - superconducting MRI magnet which we have developed. Multi section type superconducting MRI main coil and various superconducting shims were designed and fabricated for obtaining the high field homogeneity, which is requested in the MR imaging. After assembling the magnet with room temperature bore cryostat field homogenity has been measured and analyzed by NMR field mapping system. According to this, field homogeneity of 22 ppm / 30 cm dsv was confirmed.

  • PDF

Cloning and Expression Characteristics of Pharbitis nil COP1 (PnCOP1) During the Floral Induction

  • Kim, Yun-Hee;Kim, Seong-Ryong;Heo, Yoon-Kang
    • Journal of Photoscience
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2005
  • The ubiquitin E3 ligase COP1 (Constitutive Photomorphogenesis 1) is a protein repressor of photomorphogenesis in Arabidopsisplants, and it found in various organisms, including animals. The COP1 protein regulates the stability of many of the light-signaling components that are involved in photomorphogenesis and in the developmental processes. To study the effect of COP1 on flowering in a short day plant, we have cloned a full-length of PnCOP1 (Pharbitis nil COP1) cDNA from Pharbitis nil Choisy cv. Violet, and we examined its transcript levels under various conditions. A full-length PnCOP1 cDNA consists of 2,280 bp nucleotidesthat contain 47 bp of 5'-UTR, 232 bp of 3'-UTR including the poly (A) tail, and 1,998 bp of the coding sequence. The deduced amino acid sequence contains 666 amino acids, giving it a theoretical molecular weight of 75 kD and a isolectric point of 6.2. The PnCOP1 contains three distinct domains, an N-terminal $Zn^2+$-binding RING-finger domain, a coiled-coil structure, and WD40 repeats at the C-terminal, implying that the protein plays a role in protein-protein interactions. The PnCOP1 transcript was detected in the cotyledon, hypocotyls and leaves, but not in root. The levels of the PnCOP1 transcript were reduced in leaves that were a farther distance away from the cotyledons. The expression level of the PnCOP1 gene was inhibited by light, while the expression was increased in the dark. During the floral inductive 16 hour-dark period for Pharbitis nil, the expression was increased and it reached its maximum at the 12th hour of the dark period. The levels of PnCOP1 mRNA were dramatically reduced upon light illumination. These results suggest that PnCOP1 may play an important function in the floral induction of Pharbitis nil.

  • PDF

A multi-functional cable-damper system for vibration mitigation, tension estimation and energy harvesting

  • Jung, Hyung-Jo;Kim, In-Ho;Koo, Jeong-Hoi
    • Smart Structures and Systems
    • /
    • v.7 no.5
    • /
    • pp.379-392
    • /
    • 2011
  • This paper presents a multi-functional system, consisting of a magnetorheological (MR) damper and an electromagnetic induction (EMI) device, and its applications in stay cables. The proposed system is capable of offering multiple functions: (1) mitigating excessive vibrations of cables, (2) estimating cable tension, and (3) harvesting energy for wireless sensors used health monitoring of cable-stayed bridges. In the proposed system, the EMI device, consisting of permanent magnets and a solenoid coil, can converts vibration energy into electrical energy (i.e., induced emf); hence, it acts as an energy harvesting system. Moreover, the cable tension can be estimated by using the emf signals obtained from the EMI device. In addition, the MR damper, whose damping property is controlled by the harvested energy from the EMI device, can effectively reduce excessive cable vibrations. In this study, the multi-functionality of the proposed system is experimentally evaluated by conducting a shaking table test as well as a full-scale stay cable in a laboratory setting. In the shaking table experiment, the energy harvesting capability of the EMI device for wireless sensor nodes is investigated. The performance on the cable tension estimation and the vibration mitigation are evaluated using the full-scale cable test setup. The test results show that the proposed system can sufficiently generate and store the electricity for operating a wireless sensor node twice per day, significantly alleviate vibration of a stay cable (by providing about 20% larger damping compared to the passive optimal case), and estimate the cable tension accurately within a 2.5% error.

Traffic Flow Sensing Using Wireless Signals

  • Duan, Xuting;Jiang, Hang;Tian, Daxin;Zhou, Jianshan;Zhou, Gang;E, Wenjuan;Sun, Yafu;Xia, Shudong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.10
    • /
    • pp.3858-3874
    • /
    • 2021
  • As an essential part of the urban transportation system, precise perception of the traffic flow parameters at the traffic signal intersection ensures traffic safety and fully improves the intersection's capacity. Traditional detection methods of road traffic flow parameter can be divided into the micro and the macro. The microscopic detection methods include geomagnetic induction coil technology, aerial detection technology based on the unmanned aerial vehicles (UAV) and camera video detection technology based on the fixed scene. The macroscopic detection methods include floating car data analysis technology. All the above methods have their advantages and disadvantages. Recently, indoor location methods based on wireless signals have attracted wide attention due to their applicability and low cost. This paper extends the wireless signal indoor location method to the outdoor intersection scene for traffic flow parameter estimation. In this paper, the detection scene is constructed at the intersection based on the received signal strength indication (RSSI) ranging technology extracted from the wireless signal. We extracted the RSSI data from the wireless signals sent to the road side unit (RSU) by the vehicle nodes, calibrated the RSSI ranging model, and finally obtained the traffic flow parameters of the intersection entrance road. We measured the average speed of traffic flow through multiple simulation experiments, the trajectory of traffic flow, and the spatiotemporal map at a single intersection inlet. Finally, we obtained the queue length of the inlet lane at the intersection. The simulation results of the experiment show that the RSSI ranging positioning method based on wireless signals can accurately estimate the traffic flow parameters at the intersection, which also provides a foundation for accurately estimating the traffic flow state in the future era of the Internet of Vehicles.

Synthesis, Characterization and Cosmetic Application of Self-Assembled Sericin-PEG Nanoparticle

  • E. S. Choung;S. Y. Eom;Kim, J. H.;Kim, K. S.;Kim, K. H.;Lee, K. G.;Lee, Y. W.;C. S. Cho
    • Proceedings of the SCSK Conference
    • /
    • 2003.09a
    • /
    • pp.501-519
    • /
    • 2003
  • Silk Sericin(SS) is a natural protein extracted from cocoon of bombix mori and shows moisturizing effect to the skin due to a number of hydroxyl groups in the structure. But its application to cosmetics is limited due to its poor solubility in water. In order to solve this drawback and expand its application to cosmetics, polyethyleneglycol(PEG) was conjugated with sericin by reacting activated polyethyleneglycol(ActPEG). Reaction site of sericin is tyrosine residue, which was determined by using $^1$H-NMR. Random coil structure of sericin was transformed to beta-sheet structure by conjugating polyethyleneglycol. It was confirmed that melting point of sericin-PEG conjugate was lowered compared to that of each sericin and PEG due to the interaction between sericin and PEG in crystalline structure. Self-assembled sericin-PEG nanoparticle was obtained by dialyzing with alcohol solution of sericin-PEG conjugate against water. The particle is spherical and has 200-400nm of size. The moisturizing ability of sericin-PEG nanoparticle was much higher than that of sericin itself. Incorporation of vitamin A into sericin-PEG nanoparticle was carried out by diafiltration method. The content of incorporated Vitamin A in sericin-PEG nanoparticle was 8.9 wt%. Releasing behaviour of vitamin A incorporated into nanoparticle was tested in phosphate buffer, pH 7.4 at 37$^{\circ}C$. and half-life of Vitamin A release was 43hrs. Sericin-PEG nanoparticle exhibited higher moisturing effect than sericin itself and distilled water, respectively. No toxicity and irritation were observed in animal tests. It can be expected that the self-assembled sericin-PEG nanoparticle can be developed for cosmetics.

  • PDF

Verification of External Magnetization based EM Technique for Diagnosing Residual Tensile Stress in Aged PSC Structures (노후 PSC 구조물의 잔여 긴장 응력 진단을 위한 외부 자화 EM 기법 검증)

  • Soon-Jeon Park;Sehwan Park;Jaehoon Choi;Kyo-Young Jeon;Junkyeong Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.4
    • /
    • pp.251-257
    • /
    • 2023
  • This study entailed an investigation of a tensile stress measurement method for prestressed concrete (PSC) tendons by utilizing external magnetization. The target of this study are PS structures that have been constructed and in use. An optimal external magnetization based elasto-magnetic (EM) sensor was designed using finite element analysis considering various factors, such as coil arrangement and size, that could influence the PS tendons inside the PSC girder. The residual tensile stress resulting from the external magnetization of the girder was then determined. Further, theoretical verification was performed using the numerical and material data used in the finite element analysis for sensor design. The calculated values of strength of magnetization at the target location were matched with the finite element analysis results. Thus, the designed sensor and the feasibility of magnetizing the tendons inside the PSC I-girder using an EM sensor were validated.