• Title/Summary/Keyword: E-Seal

Search Result 79, Processing Time 0.038 seconds

Evaluation for Argon gas-filled Insulating glass units (아르곤가스 주입 단열 복층유리 내구성 평가)

  • Kim, Kyung-Nam;Jung, Jin-Young;Bae, Ki-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.128-131
    • /
    • 2013
  • Energy losses through windows and doors are big problems in the construction industry. For glass only, it has takes the largest portion of mass from window assembly and it responsible for 24 ~ 45% of energy loss from total building energy loss. Insulating glass unit should maintain their basic functions during their working life in order to contribute positively for global warming issue. There have been many research works for improving insulating glass unit durability. But it is not easy job to fulfill the requirements because insulating glass units composed of many components. So, overall it is required to have right qualify control procedures starting from material selection to fabrication, shipping and installation to the customer site. In this report, we have reviewed the durability of insulating glass unit made from different grades of sealing materials based on globally accepted industry codes such as EN1279. ASTM E 2190 and Locally available code. KS L 2003. The result showed that there is a relationship between the mechanical properties of insulating glass 2nd sealant and the durability of the units.

  • PDF

Substrate roughness induces the development of defective E-cadherin junctions in human gingival keratinocytes

  • Jin, Chengbiao;Lee, Gayoung;Oh, Changseok;Kim, Hyun Jung;Kim, Hyun-Man
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.2
    • /
    • pp.116-131
    • /
    • 2017
  • Purpose: The entry of bacteria or harmful substances through the epithelial seal of human gingival keratinocytes (HGKs) in the junctional epithelium (JE) is blocked by specialized intercellular junctions such as E-cadherin junctions (ECJs). However, the influence of roughened substrates, which may occur due to apical migration of the JE, root planing, or peri-implantitis, on the development of the ECJs of HGKs remains largely unknown. Methods: HGKs were cultured on substrates with varying levels of roughness, which were prepared by rubbing hydrophobic polystyrene dishes with silicon carbide papers. The activity of c-Jun N-terminal kinase (JNK) was inhibited with SP600125 or by transfection with JNK short hairpin RNA. The development of intercellular junctions was analyzed using scanning electron microscopy or confocal laser scanning microscopy after immunohistochemical staining of the cells for E-cadherin. The expression level of phospho-JNK was assessed by immunoblotting. Results: HGKs developed tight intercellular junctions devoid of wide intercellular gaps on smooth substrates and on rough substrates with low-nanometer dimensions (average roughness $[Ra]=121.3{\pm}13.4nm$), although the ECJs of HGKs on rough substrates with low-nanometer dimensions developed later than those of HGKs on smooth substrates. In contrast, HGKs developed short intercellular junctions with wide intercellular gaps on rough substrates with mid- or high-nanometer dimensions ($Ra=505.3{\pm}115.3nm$, $867.0{\pm}168.6nm$). Notably, the stability of the ECJs was low on the rough substrates, as demonstrated by the rapid destruction of the cell junction following calcium depletion. Inhibition of JNK activity promoted ECJ development in HGKs. JNK was closely associated with cortical actin in the regulation of ECJs in HGKs. Conclusions: These results indicate that on rough substrates with nanometer dimensions, the ECJs of HGKs develop slowly or defectively, and that this effect can be reversed by inhibiting JNK.

New Generation of Lead Free Solder Spheres 'Landal - Seal'

  • Walter H.;Trodler K. G.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2004.09a
    • /
    • pp.211-219
    • /
    • 2004
  • A new alloy definition will be presented concerning increasing demands for the board level reliability of miniaturized interconnections. The damage mechanism for LFBGA components on different board finishes is not quite understood. Further demands from mobile phones are the drop test, characterizing interface performance of different package constructions in relation to decreased pad constructions and therefore interfaces. The paper discusses the characterization of interfaces based on SnPb, SnPbXYZ, SnAgCu and SnAgCuInNd ball materials and SnAgCuInNd as solder paste, the stability after accelerated tests and the description of modified interfaces stric시y related to the assembly conditions, dissolution behavior of finishes on board side and the influence of intermetallic formation. The type of intermetallic as well as the quantity of intermetallics are observed, primaliry the hardness, E modules describing the ability of strain/stress compensation. First results of board level reliability are presented after TCT-40/+150. Improvement steps from the ball formulation will be discussed in conjunction to the implementation of lead free materials. In order to optimize ball materials for area array devices accelareted aging conditions like TCTs were used to analyze the board level reliability of different ball materials for BGA, LFBGA, CSP, Flip Chip. The paper outlines lead-free ball analysis in comparison to conventional solder balls for BGA and chip size packages. The important points of interest are the description of processability related to existing ball attach procedures, requirements of interconnection properties and the knowledge gained the board level reliability. Both are the primary acceptance criteria for implementation. Knowledge about melting characteristic, surface tension depend on temperature and organic vehicles, wetting behavior, electrical conductivity, thermal conductivity, specific heat, mechanical strength, creep and relaxation properties, interactions to preferred finishes (minor impurities), intermetallic growth, content of IMC, brittleness depend on solved elements/IMC, fatigue resistance, damage mechanism, affinity against oxygen, reduction potential, decontamination efforts, endo-/exothermic reactions, diffusion properties related to finishes or bare materials, isothermal fatigue, thermo-cyclic fatigue, corrosion properties, lifetime prediction based on board level results, compatibility with rework/repair solders, rework temperatures of modified solders (Impurities, change in the melting point or range), compatibility to components and laminates.

  • PDF

Development of the Vision System to Inspect the Inside of the Brake Calipers (브레이크 캘리퍼 내부 검사를 위한 비전시스템 개발)

  • Kwon, Gyoung Hoon;Chu, Hyung Gon;Kim, Jin Young;Kang, Joonhee
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.39-43
    • /
    • 2017
  • Development of vision system as a nondestructive evaluation system can be very useful in screening the defective mechanical parts before they are assembled into the final product. Since the tens of thousands of the mechanical parts are used in an automobile carefully inspecting the quality of the mechanical parts is very important to maximize the performance of the automobile. To sort out the defective mechanical parts before they are assembled, auto parts fabrication companies employ various inspection systems. Nondestructive evaluation systems are getting rapidly popular among various inspection systems. In this study, we have developed a vision system to inspect the inside of the brake caliper, a part that is used to compose a brake which is the most important to the safety of the drivers and the passengers. In a brake caliper, a piston is pushed against the brake disk by oil pressure, causing a friction to damp the rotation of the wheel. Inside the caliper, a groove is positioned to adopt an oil seal to prevent the oil leaks. Inspecting the groove with our vision system, we could examine the existence of the contaminants which are normally the residual tiny pieces from the machining process. We used a high resolution GigE camera, 360 degree lens to look in the inside view of the caliper at once, and a special illumination system in this vision system. We used the edge detection technique to successfully detect the contaminants which were in the form of small metal chips. Labview graphical program was used to process the digital data from the camera and to display the vision and the statistics of the contaminants. We were very successful in detecting the contaminants from the various size calipers. We think we are ready to employ this vision system to the caliper production factories.

Alveolar ridge preservation with a collagen material: a randomized controlled trial

  • Schnutenhaus, Sigmar;Doering, Isabel;Dreyhaupt, Jens;Rudolph, Heike;Luthardt, Ralph G.
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.4
    • /
    • pp.236-250
    • /
    • 2018
  • Purpose: Resorption of the alveolar bone is an unavoidable consequence of tooth extraction when appropriate alveolar ridge preservation (ARP) measures are not taken. The objective of this trial was to test the hypothesis that dimensional changes in the alveolar bone after tooth extraction would be reduced by inserting an equine collagen membrane and a collagen cone to fill and seal the alveolus (as ARP), in comparison to extraction with untreated alveoli. Methods: In this randomized clinical trial, 31 patients were directly treated with the collagen material after extraction of a tooth from the maxilla (the ARP group). Twenty-nine patients served as the control group. After extraction, no further treatment (i.e., no socket preservation measures) was performed in the control group. Changes in the alveolar process immediately after extraction and after an 8 (${\pm}1$)-week healing period were evaluated 3-dimensionally. Blinded analyses were performed after superimposing the data from the digitalized impressions and surfaces generated by cone-beam computed tomography. Results: Both the ARP and control groups showed a reduction of bone in the alveolar area after tooth extraction. However, significantly less bone resorption was detected in the clinically relevant buccal region in the ARP group. The median bone reduction was 1.18 mm in the ARP group and 5.06 mm in the control group (P=0.03). Conclusions: The proposed hypothesis that inserting a combination material comprising a collagen cone and membrane would lead to a difference in alveolar bone preservation can be accepted for the clinically relevant buccal distance. In this area, implantation of the collagen material led to significantly less alveolar bone resorption. German Clinical Trials Register at www.drks.de, DRKS00004769.

Development of Vibration Absorption Device for the Transportation-Trailer System(I) - Characteristics for the existing vehicle - (수송 트레일러의 충격 흡수 장치 개발(I) - 보급기종에 대한 특성 및 진단 -)

  • 이홍주;홍종호;이성범;김성엽
    • Journal of Biosystems Engineering
    • /
    • v.28 no.2
    • /
    • pp.89-96
    • /
    • 2003
  • This study was aimed to identify how the main body vibration of power tiller will be transmitted to the trailer, and to find out the basic information for demage reducing method of agricultural products during transportation. The vertical vibration acceleration level was measured at 6 positions, i.e. engine, hitch, seal and three parts of trailer (front middle, and rear) for the not driving but at the engine speeds of 1,000rpm and driving at 0.35m/s. The results of this research could be summarized as follows; 1. For not driving, the accumulated acceleration level up to 120Hz was 50% of total accelerations at engine part and those were 28~41% at other parts. Those up to 40Hz were 20~30% at engine and hitch part and 2~8% at trailer part. And those up to 20Hz were 13~20% at engine and hitch part and 1~4% at trailer part 2. For the driving with 0.35m/s at paved road, the average vertical accelerations were in the range of 0.005~0.058m/s$^2$. The lowest value of 0.005m/s$^2$ was showed at engine part and the value of 0.031-0.058m/s$^2$ was showed at trailer part. 3. For the driving with 0.35m/s, the accumulated value of average vertical accelerations showed the lowest value at engine parts md showed 5 times value of engine part at trailer part especially highest value at middle part of trailer. 4. For the driving with 0.35m/s, the accumulated acceleration level up to 120Hz was 75% of total accelerations at engine part and those were 20~42% at other parts. Ant those up to 20Hz and 40Hz were 24~26% at engine part and 0.1~0.6% at trailer part.

Studies on antibiotics resistance gene in Staphylococcus aureun Plasmid: Cloning of chloramphenicol resistance determinant (Staphylococcus aureus에서 분리된 plasmid상의 항생물질 저항성 인자에 관한 연구 : Chloramphenicol 저항성 인자의 클로닝)

  • 권동현;김영선;변우현
    • Korean Journal of Microbiology
    • /
    • v.24 no.4
    • /
    • pp.341-351
    • /
    • 1986
  • R-plasmid(pSBK203, 2.5Mdal) conferring chloramphenicol resistance was isolated from mutiple antibiotic resistant Staphylococcus aureus D-H-1. Bacillus subtilis BD170 was transformed by this plasmid and restriction enzyme clevage sites of this plasmid were mapped for the cloning of chloramphenicol resistance gene. Taq I partial digested fragment of pSBK203(1.3kb) inserted into Cla I site of pBD9 appears to have both regulatory region for induction and structural gene for chloramphenicol resistance whereas Rsa I fragment (1.3kb, both ends are staggered away 0.1Kb from those of Taq I fragment) inserted into Sca I site of pBR322 showed constitutive expression in E. coli. Hinf I, Taq I, and Bgl II restriction enzyme recognition sites are found in both Rsa I fragment and Taq I fragment. Among these, Bgl II recognition site was associated with chloramphenicol resistance.

  • PDF

Chemical and Physical Influence Factors on Performance of Bentonite Grouts for Backfilling Ground Heat Exchanger (지중 열교환기용 벤토나이트 그라우트의 시공성에 대한 화학적, 물리적 영향 요소에 관한 연구)

  • Lee, Chul-Ho;Gil, Hu-Jeong;Lee, Kang-Ja;Choi, Hang-Seok;Choi, Hyo-Pum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1475-1486
    • /
    • 2008
  • Bentonite-based grouting has been popularly used to seal a borehole installed for a closed-loop vertical ground heat exchanger in a geothermal heat pump system (GHP) because its high swelling potential. However, if the bentonite-based grouting is conducted in coastal areas, the salinity of groundwater changes in the mineral fabric of bentontie. In order words, an increase of cation concentration in groundwater leads to a reduction in the diffuse double-layer thickness in the bentonite mineral structure, and thus the volume of bentointe-based grouts will decrease proportional to the salinity of groundwater. In this paper, the effect of salinity (i.e., NaCl 0.5M, 0.25M, and 0.1M) on the change of swelling potential for bentonite-based grouts has been quantitatively evaluated for seven bentonite grouts from different product sources. In addition, in case of using addictives such as a silica sand to increase the thermal conductivity of bentonite-based grouts, the possibility of particle segregation has been studied considering the viscosity of grouts and salinity of groundwater.

  • PDF

Deformation Characteristics and Sealing Performance of Metallic O-rings for a Reactor Pressure Vessel

  • Shen, Mingxue;Peng, Xudong;Xie, Linjun;Meng, Xiangkai;Li, Xinggen
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.533-544
    • /
    • 2016
  • This paper provides a reference to determine the seal performance of metallic O-rings for a reactor pressure vessel (RPV). A nonlinear elastic-plastic model of an O-ring was constructed by the finite element method to analyze its intrinsic properties. It is also validated by experiments on scaled samples. The effects of the compression ratio, the geometrical parameters of the O-ring, and the structure parameters of the groove on the flange are discussed in detail. The results showed that the numerical analysis of the O-ring agrees well with the experimental data, the compression ratio has an important role in the distribution and magnitude of contact stress, and a suitable gap between the sidewall and groove can improve the sealing capability of the O-ring. After the optimization of the sealing structure, some key parameters of the O-ring (i.e., compression ratio, cross-section diameter, wall thickness, sidewall gap) have been recommended for application in megakilowatt class nuclear power plants. Furthermore, air tightness and thermal cycling tests were performed to verify the rationality of the finite element method and to reliably evaluate the sealing performance of a RPV.

Investigation of PCT Behavior in IBLOCA Counterpart Tests between the ATLAS and LSTF Facilities (중형냉각재상실사고의 PCT에 대한 ATLAS와 LSTF 장치의 대응 실험 검토)

  • Kim, Yeon-Sik;Kang, Kyoung-Ho
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.26-33
    • /
    • 2019
  • A comparison of CL 13% and 17% IBLOCA counterpart tests(CPTs) between the ATLAS and LSTF facilities was carried out and the behavior of peak cladding temperatures(PCTs) and related thermal hydraulic phenomena were investigated and discussed. There appeared quite a big difference in PCT behavior between the two CPTs and a further comparison of reactor coolant system design between the two facilities was performed. As a result, there was a difference in fuel alignment plate (FAP) design, e.g., one FAP in ATLAS, a combination of upper core plate and upper end box in LSTF, respectively. The FAP design mainly affects the reflux condensate behavior in IBLOCA tests and any difference in FAP design can be a possible reason for different PCT behavior between the two facilities. It should be a further study to find the reason of different PCT behvior between the two facilites.