• Title/Summary/Keyword: E-Health System

Search Result 958, Processing Time 0.028 seconds

Performance of Local Exhaust Ventilation Systems of Degreasing and Plating Workplaces (일부 탈지세척 및 도금공정 국소배기장치의 성능점검과 개선방안)

  • Han, Don-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.178-185
    • /
    • 1998
  • In order to evaluate and improve the performance of local exhaust ventilation systems for two TCE degreasing (A, B) and two electroplating (C, E) and one acid dipping & plating (D) operations located in Kimhae, the performance test was conducted with trace gases and a thermal anemometer (Kanomax 24-6111, Japan). For the inadequately designed systems, the improvement and redesigns in compliance with recommendation by ACGIH was suggested. The results of performance test for each system are as follows; 1. System of Workplace A was generally well-designed. Actual exhaust air flow rate was in excess of 68% above the recommended standard exhaust air flow rate. 2. System of Workplace B was very well-designed and completely enclosed. 3. All systems of Workplace C including hoods were poorly-designed and actual exhaust air flow rates were insufficient for open tanks. All systems should be upgraded according to ACGIH recommendations. 4. Supply and exhaust air flow rate of push-pull exhaust systems in Workplace D should be greatly increased. The width of flange of dipping tank hood should be increased with the value suggested. 5. System of Workplace E was well-designed. Actual exhaust air flow rate was in excess of 54% above the required.

  • PDF

Immunostimulatory and Bone Health-Promoting Activities of Litsea japonica Fruit Extract (까마귀쪽나무 열매 추출물의 면역증가 및 뼈 건강 효과)

  • Park, Sung-Jin;Kang, Jun-Chul;Lee, Da-young;Cho, Ju-Hyun;Yoon, Min-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.3
    • /
    • pp.284-289
    • /
    • 2020
  • This study was performed with hot water extract (LJF-W) and 70% ethanol extract (LJF-70E) of Litsea japonica fruit to investigate the immunostimulatory activity and bone health-promoting effect of L. japonica fruit. The production of pro-inflammatory mediator (nitric oxide) and pro-inflammatory cytokines (TNF-α, IL-6 and IL-1β) in murine macrophage RAW264.7 cells were estimated to examine the immunostimulatory activity of the fruit extracts. The immunostimulatory activity of LJF-W was higher than that of positive control (geinsenosides). However, there was no effect in LJF-70E. Futhermore, both LJF-W and LJF-70E appeared to stimulate the proliferation of MC3T3-E1 cells, proving the effect as a bone health agent. From this result it could be presumed that L. japonica fruit extracts not only stimulate the immune system, but also the ability to promote bone health.

Study on the Latest Trends of u-Health and Relations of Medical Technologist

  • Sung, Hyun-Ho;An, Yong-Ho;Lee, Dong-Beom;Kim, Sang-Won;Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.4
    • /
    • pp.178-183
    • /
    • 2012
  • We investigated the latest trend of u-Health and relations with clinical technologist. Since 2000, Korea has become an aging society. Korea will become an aged society by 2018, and it is expected to enter the ultra-high aged society by 2026. Increase in over 65 years population means that the desire of medical service and care demand for the elderly is greatly required. In addition, many predicted Korean national health insurance would falter financially. Medical suppression policies and regulations are also amended continuously. U-Health based on the IT industry and development of related technologies and industries contains the variety concepts of telemedicine, telehealth, e-health, u-healthcare and POCT. Especially, the use of POCT supplied quick clinical examination is extending steadily in medical center and hospital, which will generate the field friction between nurses and medical technologists. In the transition situation from provider-centric service to consumer-driven health care system, this study recommended the principal role and correspondence of clinical laboratory workers and offered information about changes in healthcare market and the basic concept of expert system, measurement and the diagnosis principle to clinical technicians throughout the investigation of the recent research and government policy trends.

  • PDF

A Study on the Necessity of Advanced Safety Systems in Driver Emergencies (운전자 응급상황에서의 첨단안전시스템 필요성 연구)

  • Byungdo Kang;Bonggyun Jo;Yunhwa Lee;Taehyeong Kim
    • Journal of Auto-vehicle Safety Association
    • /
    • v.15 no.1
    • /
    • pp.63-68
    • /
    • 2023
  • A study on the need for a safety system using driver's biometric information, vehicle automatic emergency braking system, and the e-call system that in the event of an unexpected situation such as loss of driving ability due to sudden physical abnormality of elderly drivers and drivers with health problems, and the improvement of laws for the spread of this system were studied.

Mucin2 is Required for Probiotic Agents-Mediated Blocking Effects on Meningitic E. coli-Induced PathogenicitiesS

  • Yu, Jing-Yi;He, Xiao-Long;Puthiyakunnon, Santhosh;Peng, Liang;Li, Yan;Wu, Li-Sha;Peng, Wen-Ling;Zhang, Ya;Gao, Jie;Zhang, Yao-Yuan;Boddu, Swapna;Long, Min;Cao, Hong;Huang, Sheng-He
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.10
    • /
    • pp.1751-1760
    • /
    • 2015
  • Mucin2 (MUC2), an important regulatory factor in the immune system, plays an important role in the host defense system against bacterial translocation. Probiotics known to regulate MUC2 gene expression have been widely studied, but the interactions among probiotic, pathogens, and mucin gene are still not fully understood. The aim of this study was to investigate the role of MUC2 in blocking effects of probiotics on meningitic E. coli-induced pathogenicities. In this study, live combined probiotic tablets containing living Bifidobacterium, Lactobacillus bulgaricus, and Streptococcus thermophilus were used. MUC2 expression was knocked down in Caco-2 cells by RNA interference. 5-Aza-2'-deoxycytidine (5-Aza-CdR), which enhances mucin-promoted probiotic effects through inducing production of Sadenosyl-L-methionine (SAMe), was used to up-regulate MUC2 expression in Caco-2 cells. The adhesion to and invasion of meningitic E. coli were detected by competition assays. Our studies showed that probiotic agents could block E. coli-caused intestinal colonization, bacteremia, and meningitis in a neonatal sepsis and meningitis rat model. MUC2 gene expression in the neonatal rats given probiotic agents was obviously higher than that of the infected and uninfected control groups without probiotic treatment. The prohibitive effects of probiotic agents on MUC2-knockdown Caco-2 cells infected with E44 were significantly reduced compared with nontransfected Caco-2 cells. Moreover, the results also showed that 5-Aza-CdR, a drug enhancing the production of SAMe that is a protective agent of probiotics, was able to significantly suppress adhesion and invasion of E44 to Caco-2 cells by upregulation of MUC2 expression. Taken together, our data suggest that probiotic agents can efficiently block meningitic E. coli-induced pathogenicities in a manner dependent on MUC2.

Development of a Finger Tactile Stimulator Based on E-Prime Software (E-Prime에 기반한 손가락 촉각 자극기의 개발)

  • Kim, Hyung-Sik;Min, Yoon-Ki;Kim, Bo-Seong;Min, Byung-Chan;Yang, Jae-Woong;Lee, Su-Jeong;Choi, Mi-Hyun;Yi, Jeong-Han;Tack, Gye-Rae;Lee, Bong-Soo;Jun, Jae-Hoon;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.703-710
    • /
    • 2010
  • In this study, a tactile stimulator was developed to resolve some problems from the previous version of the system such as system configuration, inappropriate stimulation control and additional problems. The developed tactile stimulator consists of control unit, drive unit and vibrator unit. The control unit was controlled by E-Prime software to generate appropriate vibration pulses. The drive unit supplies enough energy to the vibrator to generate effective stimulation pulses. The vibrator unit consists of small coin type vibrator and velcro, and was made to be attached at the hand easily. The developed tactile stimulator was designed by small-size, light-weight, low-power, simple-fabrication, max 35 channels and little delay time from instruction signal of E-Prime software to vibrator. The duration and magnitude of stimulation was controlled by 10 grades and the problems concerning stimulation control were compensated by wideband frequency ranges. Additionally, the electrical safety was ensured by low voltage operation. Vibrator was made to be attached on finger as well as on any part of the subject. Since this tactile stimulator is developed based on E-Prime software which is widely used in cognitive science, it is believed that this stimulator be suitable for the wide application of cognitive science study.

  • PDF

Improvement of Wireless Connectivity and Efficiency in E-Healthcare Service System Using a Proxy in Body Area Device

  • Kim, Sang Kon;Kim, Tae Kon;Koh, Jinhwan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.3
    • /
    • pp.991-1013
    • /
    • 2020
  • E-health services have provided interoperability between personal health devices in personal area network, based the ISO/IEEE 11073 standard. In the healthcare system, the manager handles most agents concurrently through wireless communication. However, due to the distance limitation and the increased number of agents, it may be difficult to provide continuous connectivity. Recently, body area devices have been equipped with various applicable agents, which can even handle agents on behalf of the manager. A BAD may act as an intermediary device to increase system efficiency and performance. In this study, a device called "proxy", which can be installed as software on BAD devices, is proposed. The data measured by an agent can be sent to the proxy first, and subsequently be sent to the manager again. Agents and the manager are not aware of the proxy existence and work normally without the proxy. Furthermore, a new smart proxy and modified manager are proposed. The smart proxy acts as one agent handling measurement data from several agents, which can transmit a significant amount of data at once. The proxy and smart proxy maintain compatibility with existing devices that conform to the 20601 standard. The proposed schemes are verified and the complexities of devices are analyzed. The analysis shows no significant difference among the proxy, smart proxy, and manager. Simulations exhibit that the proposed schemes can improve the system performance.

A Design and Implementation of Mobile Healthcare System based on Smart Gateway (스마트 게이트웨이 기반 모바일 헬스케어시스템의 설계 및 구현)

  • Kang, Sung-In;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.1970-1976
    • /
    • 2012
  • Home healthcare system has lot of things to do for the integration with medical instruments in the sense of standardization. We will design and implement mobile healthcare system based on smart gateway thru adaptation of ISO/IEEE 11073, and HL7 standard. And also we are willing to research heart rate monitor, pulse-oxygen meter and ECG monitor in order to develop mobile healthcare system for medical appliance. We studied the connection of standard medical devices, i.e, continua health alliance under the Android 4.x Bluetooth HDP(Health Device Profile) environments. We also tried to implement healthcare system which can support diagnosis for healthcare provider and user based on HL7 standard.

The Minimum Autoignition Temperature Behavior(MAITB) of n-Decane and Acetic acid Mixture (n-Decane과 Acetic acid 혼합물의 최소자연발화온도 거동)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.49-54
    • /
    • 2013
  • The autoignition temperature(AIT) is important index for the safe handling of flammable liquids which constitute the solvent mixtures. This study measured the AITs and ignition delay time for n-Decane and Acetic acid system by using ASTM E659 apparatus. The AITs of n-Decane and Acetic acid which constituted binary system were $212^{\circ}C$ and $512^{\circ}C$, respectively. The experimental AITs of n-Decane and Acetic acid system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D.(average absolute deviation). And n-Decane and Acetic acid system was shown the minimum autoignition temperature behavior(MAITB).

Evaluation of Significance & Development of Quantitative Measurement System for Acupoint Pigmentation by Cupping Therapy (부항요법에 의한 배수혈 혈색소 변화의 정량적 측정 시스템 개발 및 유의성 평가)

  • Kim, Soo-Byeong;Lee, Na-Ra;Jung, Byung-Jo;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.28 no.3
    • /
    • pp.63-71
    • /
    • 2011
  • Objectives : The aim of this study is to develop the system and evaluate the optical analytical technique that reflects acupoint pigmentation and extravasated blood by cupping. Methods : We designed the system able to express XYZ coordinate on local skin color. To evaluate measurement-accuracy, we compared with 24 Color Checker Chart by standardized Commission Internationale de l'Eclairage. After confirming the performance of system, we experimented with cupping which was 80 kPa negative pressure for 1 minute on left/right BL13. The X, Y and Z values were converted to R, G and B, $L^*$, $a^*$ and $b^*$, Erythema Index (E.I.), and Melanin Index (M.I). We compared and analyzed two cases on before/after cupping. Results : The R, G and B values which were converted by X, Y and Z values had high linearity as a high level of R-square (R: 0.969, G: 0.996, and B: 0.992). Moreover, we confirmed that it was possible to quantitatively analyzed the change in skin color by cupping using R, G, B, $L^*$, $a^*$, $b^*$, E.I., and M.I. Conclusions : Therefore, we proposed the new analytical technique for objectifying the oriental medical diagnostic method using cupping and optical sensing technique.