• Title/Summary/Keyword: E Field Distribution

Search Result 486, Processing Time 0.032 seconds

Distribution of Cyhalofop-butyl and Penoxsulam Resistant Echinochloa spp. in Korean Paddy Fields (국내 Cyhalofop-butyl과 Penoxsulam 저항성 피의 지역별 분포)

  • Lee, Jeongran;Kim, Jin-Won;Lee, In-Yong
    • Weed & Turfgrass Science
    • /
    • v.6 no.4
    • /
    • pp.345-349
    • /
    • 2017
  • Herbicides are important weed control tools for increasing crop yields and the efficiency of crop production. As the use of herbicides increases, the occurrrence of herbicide-resistant weeds has been an increaing problem. In Korea, since the first occurrence of acetolactate synthase (ALS) inhibitor resistant Monochoria korsakowii was reported in the Seosan reclaimed paddy field in 1998, resistance has been reported in 14 weed species, including Echinochola spp. and their populations are gradually increasing. The objective of this study is to investigate the nationwide occurrence of ALS and Acetyl-CoA Carboylase inhibitor resistant Echinochloa spp. in Korea. In 2013, 2014, and 2015, we collected 594 accessions of Echinochloa spp. in Korean rice fields except for Jeonnam and Chungbuk provinces. They were then treated with the recommended rates of penoxsulam and cyhalofop-butyl. We harvested seeds from 45 accessions of E. oryzicola in the case of cyhalofop-butyl treatment. Also, 44 and 46 accessions of E. oryzicola and E. crus-galli survived and their seeds were harvested after penoxsulam treatment. Twenty accessions of E. oryzicola survived from both herbicides inferring possible multiple resistance. Two accessions out of 20 inferred from possible multiple resistance survived after cyhalofop-butyl treatment at a dose of $500ga.i.ha^{-1}$. Seeds of herbicide resistant populations will be provided and utilized for further research.

Determination of Spectrum-Exposure Rate Conversion Factor for a Portable High Purity Germanium Detector (휴대형 고순도 게르마늄검출기에 대한 스펙트럼-조사선량율 변환연산자의 결정)

  • Kwak, Sang-Soo;Park, Chong-Mook;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.29-40
    • /
    • 1988
  • A spectrum-exposure rate conversion operator G(E) for a portable HPGe detector used for field environmental radiation survey was theoretically developed on the basis of a space distribution function of gamma flux emitted from a disk source and an areal efficiency of the detector. The radiation exposure rates measured using this G(E) and the portable HPGe. detector connected to a portable multichannel analyzer were compared with those measured by a 3' ${\phi}\;{\times}$3' NaI(Tl) scintillation detector with the reported G(E) and a pressurized ionization chamber. A comparison of the three results showed that the result obtained using the HPGe detector was lower than those determined using the NaI(Tl) detector and ionization chamber by 17% to 29%, The difference obtained is close to that reported in literature. The method developed here can be easily applicable to obtain a G(E) factor suitable to any detector for detecting the exposure rate of environmental gamma radiation, since the spectrum-exposure rate conversion operator can be calculated by a hand calculator.

  • PDF

A Study on Numerical Calculations of Hybrid Air Pollution Control System Coupled with SDR and Bag Filter (반건식 반응기와 백필터를 결합한 하이브리드 대기오염제어 시스템의 수치해석적 연구(I))

  • Kwon, Young-Hyun;Kim, Jin-Uk;Jung, Yu-Jin;Kim, Min-Choul;Lee, Jae-Jeong;Lee, Gang-Woo;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4656-4663
    • /
    • 2010
  • In this study, the 3D computational fluid dynamics (CFD) was performed in relation to the internal fluid characteristics, flow distribution, air mean ages, and residence time for the development of the most optimal model in the complex post-disposal device. As it is expected that a channeling (drift) would be made by the semi-dry reactor due to the large difference in the flow distribution by the compartment in the bag filter, a structural improvement should be urgently made for more uniformed flow distribution in the bag filter. In addition, it showed the possibility that the velocity field and distribution characteristics of the residence time could be improved through a modification to inlet structure of the spray dryer reactor. The complex post-disposal device, modified and supplemented with this analysis, integrated the semi-dry reactor and the bag filter in a single body, so it follows that the improvement can make the device compact, the installation area, the operation fee, and management more convenient.

Comparison of ANN model's prediction performance according to the level of data uncertainty in water distribution network (상수도관망 내 데이터 불확실성에 따른 절점 압력 예측 ANN 모델 수행 성능 비교)

  • Jang, Hyewoon;Jung, Donghwi;Jun, Sanghoon
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1295-1303
    • /
    • 2022
  • As the role of water distribution networks (WDNs) becomes more important, identifying abnormal events (e.g., pipe burst) rapidly and accurately is required. Since existing approaches such as field equipment-based detection methods have several limitations, model-based methods (e.g., machine learning based detection model) that identify abnormal events using hydraulic simulation models have been developed. However, no previous work has examined the impact of data uncertainties on the results. Thus, this study compares the effects of measurement error-induced pressure data uncertainty in WDNs. An artificial neural network (ANN) is used to predict nodal pressures and measurement errors are generated by using cumulative density function inverse sampling method that follows Gaussian distribution. Total of nine conditions (3 input datasets × 3 output datasets) are considered in the ANN model to investigate the impact of measurement error size on the prediction results. The results have shown that higher data uncertainty decreased ANN model's prediction accuracy. Also, the measurement error of output data had more impact on the model performance than input data that for a same measurement error size on the input and output data, the prediction accuracy was 72.25% and 38.61%, respectively. Thus, to increase ANN models prediction performance, reducing the magnitude of measurement errors of the output pressure node is considered to be more important than input node.

Identification of the Transmissive Fractures in the Vicinity of waterway Tunnel (도수로터널 주변 지역의 지하수 유동성 단열 규명)

  • 이병대;이인호;추창오;함세영;성익환;황세호
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.3
    • /
    • pp.33-44
    • /
    • 2002
  • A field technique for assessing the transmissive fractures in an aquifer was applied to a fractured rock formation in Youngchun area Korea. Geological mapping and detailed acoustic borehole teleview(BHTV) logging were performed to obtain information about the fractures. The study area consists predominantly of two types of fractures. The fracture sets of low angle partings such as bedding and sheeting plains have strike N70-80$^{\circ}$W, 25$^{\circ}$-30$^{\circ}$SW and N3S$^{\circ}$W, 12$^{\circ}$NE, respectively. In areas of high fractures, on the other hand, the major fracture sets show strike N80$^{\circ}$W and dip 70$^{\circ}$-85$^{\circ}$SW, N10$^{\circ}$E.85$^{\circ}$SE in sedimentry rocks, N40-50$^{\circ}$E.85$^{\circ}$SE/85$^{\circ}$NE, N70$^{\circ}$E.80$^{\circ}$SE, and N7$^{\circ}$-75$^{\circ}$W.80$^{\circ}$SW in granites and volcanic rocks. Injection tests have been performed to identify discrete production zones and quantify the vertical distribution of hydraulic conductivity. The calculated hydraulic conductivities range from 3.363E-10 to 2.731E-6, showing that the difference between maximum and minimum value is four order of magnitude. Dominant section in hydraulic conductivity is extensively fractured. Geophysical logging was carried out to clarify characterization of the distribution of fracture zones. Transmissive fractures were evaluated through the comparison of the results obtained by each method. The temperature logs appeared to be a good indicator that can distinguish a high transmissive fractures from a common fractures in hydraulic conductivity. In numerous cases, evidence of fluid movement was amplified in the temperature gradient log. The fracture sets of N70-80$^{\circ}$W.60-85$^{\circ}$NE/SW N75-80$^{\circ}$W.25-30$^{\circ}$SW, N50-64$^{\circ}$W.60-85$^{\circ}$NE, N35-45$^{\circ}$E.65-75$^{\circ}$SE, and N65-72$^{\circ}$E.80$^{\circ}$SE/60$^{\circ}$NW were idenfied as a distinct transmissive fractures through the results of each tests.

The Occurrence and Origin of a Syn-collisional Mélange in Timor (티모르섬 충돌 동시성 멜란지의 산상 및 기원)

  • Park, Seung-Ik;Koh, Hee Jae;Kim, Sung Won;Kihm, You Hong
    • Economic and Environmental Geology
    • /
    • v.47 no.1
    • /
    • pp.1-15
    • /
    • 2014
  • The Bobonaro m$\acute{e}$lange is one of the youngest syn-collisional m$\acute{e}$langes, located between the Indo-Australian and Eurasian plates. The m$\acute{e}$lange has formed in association with a collision between the Australian continental margin and the Banda arc initiated in Neogene. The Suai area at the southern part of Timor is a good place to examine the genetic relationship between the m$\acute{e}$lange and other rock sequences because various tectonostratigraphic units coexist in the area. In this study, we present the structural characteristics and spatial distribution of the Bobonaro m$\acute{e}$lange investigated as a part of 1:25K scale geologic mapping in the area, and discuss on the origin of the m$\acute{e}$lange. The Bobonaro m$\acute{e}$lange in the Suai area is composed of unmetamorphosed clay matrix and blocks of various lithologies. The clay matrix mainly is reddish brown or greenish gray in colour, and has scaly texture. Most blocks are allochthonous, but mostly derived from nearby formations. Based on the internal structure and relationship with surrounding rocks, the Bobonaro m$\acute{e}$lange is genetically classified into 1) diapiric m$\acute{e}$lange; 2) tectonic m$\acute{e}$lange; and 3) broken formation. The spatial distribution of the Bobonaro m$\acute{e}$lange indicates that it intruded all pre-collisional units including the lower Australian continental margin unit(Gondwana megasequence) and the Banda arc unit. Taking the field evidences and previous genetic models into consideration, the Bobonaro m$\acute{e}$lange is interpreted to be mainly formed as a diapiric m$\acute{e}$lange originated from Gondwana megasequence, consistently effected by faulting events. This study reflects that diapiric m$\acute{e}$lange is a significant component in recent accretionay-collision belts. It suggests that diapiric process should be considered as a main genetic factor even in ancient m$\acute{e}$lange.

A study on the optimization design of pulse air jet system to improve bag-filter performance (여과집진기의 탈진 성능 향상을 위한 충격 기류 분사 시스템 최적화 설계에 관한 연구)

  • Hong, Sung-Gil;Jung, Yu-Jin;Park, Ki-Woo;Jeong, Moon-Heon;Lim, Ki-Hyuk;Suh, Hye-Min;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3792-3799
    • /
    • 2012
  • The dedusting characteristics of pulse air jet type dedusting system which is widely applied in the industries were identified by utilizing the computational fluid dynamics (CFD) and the dedusting performance in modified shape of dedusting unit was compared in this study. The review on the dedusting air volume, air stream distribution and inflow velocity distribution on each shape of dedusting part showed that the case of installing the nozzle on the blow tube (Case-3) and the case of installing the double intaking tube to the venturi (Case-4 and Case-5) were more excellent than the structure (Case-1) which is widely applied in the field in its amplification effect on the air volume and extension of stream width. The specification of venturi was decided to apply the selected Case-5 for the option of the commercial back filter. It is considered that the dedusting air volume will be maintained in maximum in the case of 50 mm and 90 mm for the diameter of internal and external intaking pipe respectively.

Spatio-temporal Regression Analysis between Soil Moisture Measurements and Terrain Attributes at Hillslope Scale (사면에서 지형분석을 통한 토양수분 시공간 회귀분석)

  • Song, Tae-Bok;Kim, Sang-Hyun;Lee, Yunghil;Jung, Sungwon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.15 no.3
    • /
    • pp.161-170
    • /
    • 2013
  • Spatio-temporal distribution of soil moisture was studied to improve understanding of hydrological processes at hillslope scale. Using field measurements for three designated periods during the spring, summer and autumn seasons in 2010 obtained from Beomryunsa hillslope located at the Sulmachun watershed, correlation analysis was performed between soil moisture measurements and 18 different terrain attributes (e.g., curvatures and topographic index). The results of correlation analysis demonstrated distinct seasonal variation features of soil moisture in different depths with different terrain attributes and rainfall amount. The relationship between predicted flow lines and distribution of the soil moisture provided appropriate model structures and terrain indices.

Distribution and Antibiotic Production Characteristics for Streptomyces (Streptomyces의 토양중(土壤中) 분포(分布) 및 항생물질생산(抗生物質生産))

  • Shin, Gwan Chull;Yun, Bong Sik
    • Korean Journal of Agricultural Science
    • /
    • v.16 no.1
    • /
    • pp.36-43
    • /
    • 1989
  • Out of 826 isolates of Streptomyces isolated from different soils, their distribution and antibiotic productivity were investigated. Distribution of the organism in the soil was affected by the soil conditions and plants. The highest isolation frequency was occurred from Quercus forest, Robinia forest and grass field, while soils from orchards and cultivating fields showed low density of Streptomyces. More than 49% of the isolates showed antibacterial activity against Bacillus subtilis, Erwinia carotovora subsp. carotovora and Xantomonas campestris pv. oryzae and about 40% of the isolates showed antiyeasty activity against Saccharomyces cerevisiae but only a few isolates showed antibiotic activity against E. coli and Pseudomonas solanacearum. Forty isolates of the Streptomyces showed strong antifungal activity against Pyricularia oryzae. Rate of isolation of Streptomyces was the highest on starch agar among the eight media tested. Antibiotic productivity of the isolates was the highest on potato sucrose agar medium among the 5 media tested.

  • PDF

Post Occupancy Evaluation for Office Building with An Underfloor Air Distribution System (바닥공조 시스템이 적용된 사무공간의 거주후 성능평가)

  • Yoon, Seong-Hoon;Jang, Hyang-In;Jung, Hae-Kwon;Choi, Sun-Kyu;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.78-85
    • /
    • 2011
  • In this study, an underfloor air distribution(UFAD) system installed on the S. office building was evaluated for its indoor environmental quality performance. Field measurement and survey were conducted for the overall POE(Post Occupied Evaluation). PMV(including temperature, humidity, air velocity and globe temperature) and several environmental components were measured while thermal comfort, thermal sensation, acoustical environment and others. were investigated through survey. Except for the direct upper part of the air supply diffuser on the floor, the indoor velocity was less than 0.25m/s, which has been suggested by ASHRAES tandard 55 as the limit for thermal comfort. MRT of the perimeter zone of the room showed a higher value than that in the interior because of the introduced solar radiation through the building envelope. PMV was generally maintained in the range of thermal comfort (from -0.5 to +0.5), though it weighted to the warm side. It was reported to have 61% positive response on thermal comfort and 55% on neutral thermal sensation. The results of each survey item showed some gender-based differences. Specifically, female respondents had higher degree of dissatisfaction with indoor air cleanness and acoustical privacy. The working surface showed more than 400 lux and the equivalent noise level showed less than 50 dB(A). In conclusion, the results of the measurement and survey showed good agreement. Indoor environmental quality of the subject office room where the UFAD system was installed showed an overall excellent performance.