• 제목/요약/키워드: Dynamic voltage stability

검색결과 169건 처리시간 0.027초

실시간 기상상태를 고려한 가용송전용량 산정 (Assessment of Available Transfer Capability (ATC) considering Real-time Weather Conditions)

  • 김동민;배인수;김진오
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.485-491
    • /
    • 2010
  • Total Transfer Capability (TTC) should be pre-determined in order to estimate Available Transfer Capability (ATC). Typically, TTC is determined by considering three categories; voltage, stability and thermal limits. Among these, thermal limits are treated mainly in this paper on the evaluation of TTC due to the relatively short transmission line length of Korea Electric Power Corporation (KEPCO) system. This paper presents a new approach to evaluate the TTC using the Dynamic Line Rating (DLR) for the thermal limit. Since the approach includes not only traditional electrical constraints but also real-time environmental constraints, this paper obtains more cost-effective and exact results. A case study using KEPCO system confirms that the proposed method is useful for real-time operation and the planning of the electricity market.

고분자 전해질 연료전지와 슈퍼캐패시터 하이브리드 시스템의 운전 전략에 관한 연구 (Study of Operation Strategy for Hybrid PEM Fuel Cell and Supercapacitor)

  • 박광진;지현진;배중면
    • 대한기계학회논문집B
    • /
    • 제30권8호
    • /
    • pp.756-763
    • /
    • 2006
  • PEMFC has several technical problems such as water management, long term stability and performance degradation as. PEMFC has been studied not only to solve water management, but also to generate power in stable manner to system by using a hybrid system with auxiliary energy storage device. The purpose of this study is to couple PEMFC with supercapacitor to make a hybrid system and to design and test control strategies for stable power generation in case of changing output power. The polarization curve and dynamic behaviors while changing power were investigated to find out characteristics of PEMFC stack. A DC/DC converter was fabricated in order to increase fuel cell and supercapacitor voltage and to charge supercapacitor. We found that the operation strategy 2 was recommended to the system because of solving water management problem and increasing the dynamic behavior.

A Novel Hysteresis Control Strategy Based on Ampere-Second Balance of the Modulate Capacitor

  • Zhao, Jin-Bin;Dai, Jian-Feng;Qu, Ke-Qing;Li, Fen
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1263-1271
    • /
    • 2014
  • A novel hysteresis PWM control strategy for synchronous buck converter is proposed. The proposed control strategy is based on ampere-second balance of the modulate capacitor, which not only offers faster transient response to meet the challenges of the power supply requirements of fast dynamic load changes, but also provides better stability and solves the compensation problem of error amplifier in the conversional voltage PWM control. Finally, the steady-state and dynamic operation of the control method is analyzed and verified by simulation and experimental results.

적응 슬라이딩 관측기를 이용한 매입형 영구자석 동기전동기의 센서리스 속도제어 (Sensorless Speed Control of IPMSM using an Adaptive Sliding mode Observer)

  • 강형석;김원석;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권5호
    • /
    • pp.271-279
    • /
    • 2006
  • In this paper, a new speed sensorless control based on an adaptive sliding mode observer is proposed lot the interior permanent magnet synchronous motor(IPMSM) drives. With using voltage equation only, the adaptive sliding mode observer was investigated. Since the parameter of the dynamic equation such as machine inertia or viscosity friction coefficient are not well known and these values can be easily changed during normal operation, there are many restrictions in the actual implementation. The proposed adaptive sliding mode observer applied to overcome the problem caused by using the dynamic equation. Furthermore, the Lyapunov function is used to prove the system stability included speed estimate and speed control. The effectiveness of the proposed algorithm is confirmed by the experiments.

제주계통에 적용 가능한 유형별 HVDC 시스템의 동적 안정도 연구 (A Study on Dynamic Stability of HVDC System Type which may be Applied the Jeju AC Network)

  • 권영훈;김용학;김찬기;최영도
    • 전력전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.270-277
    • /
    • 2008
  • Capacitor Commutated Converter HVDC(High Voltage Direct Current) 시스템은 무효전력의 수급이 작기 때문에 점호각이 180도까지 증가시킬 수 있으므로 취약한 계통에 적용이 가능하다. 따라서, 본 논문에서는 변압기와 밸브 사이에 직렬커패시터가 연결된 CCC 컨버터, CSCC 컨버터 및 전형적인 전류형 컨버터에 대해 분석하고, 계통의 안정도 측면에서 PSCAD/EMTDC로 CCC 컨버터의 HVDC를 모의함으로써 신뢰성이 높음을 제시하였다.

Effect of Ramping Rate on the Durability of Proton Exchange Membrane Water Electrolysis During Dynamic Operation Using Triangular Voltage Cycling

  • Hye Young Jung;Yong Seok Jun;Kwan-Young Lee;Hyun S. Park;Sung Ki Cho;Jong Hyun Jang
    • Journal of Electrochemical Science and Technology
    • /
    • 제15권2호
    • /
    • pp.253-260
    • /
    • 2024
  • Proton exchange membrane water electrolysis (PEMWE) is an efficient method for utilizing renewable energy sources such as wind and solar powers to produce green hydrogen. For PEMWE powered by renewable energy sources, its durability is a crucial factor in its performance since irregular and fluctuating characteristics of renewable energy sources, especially for wind power, can deteriorate the stability of PEMWE. Triangular voltage cycle is well able to simulate fluctuating wind power, but its effect on the durability has not been investigated extensively. In this study, the performance degradation of the PEMWE cell operated with the triangular voltage cycling was investigated at different ramping rates. The measured current responses during the cycling gradually decreased for both ramping rates, and I-V curve measurements before and after the cycling confirmed the degradation of the performances of PEMWE. For both measurements, the degradation rate was larger for 300 mV s-1 than 30 mV s-1, and they were determined as 0.36 and 1.26 mV h-1 (at the current density of 2 A cm-2) at the ramping rates of 30 and 300 mV s-1, respectively. The comparison with other studies on triangular voltage cycling also indicate that an increase in the ramping rate accelerates the deterioration of the PEMWE performance. X-ray photoelectron spectroscopy and transmission electron microscopy results showed that the Ir catalyst was oxidized and did not dissolve during the voltage cycling. This study suggests that the ramping rate of the triangular voltage cycling is an important factor for the evaluation of the durability of PEMWE cells.

HVDC 송전을 이용한 동해안 신규전원의 수도권 계통 연계방안에 대한 연구 (A Study on the Impact of HVDC Transmission System to Interconnect Large-scale Power Generation Plants to Power Grid in Korea)

  • 한수영;권도훈;정일엽;임재봉
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1647-1656
    • /
    • 2013
  • Although the demand for electricity has been increasing these days, it becomes more difficult to find new sites for large-scale power generation plants near urban areas due to environmental and economic issues. Therefore, new power plants are forced off to rural or desolate coastal areas. As a result, there is significant regional imbalance in power generation and consumption between urban and rural areas in South Korea. This paper investigates the feasibility of high-voltage DC (HVDC) system as a candidate for electric power transmission system from east-coastal sites to metropolitan area. To this end, this paper analyzes transient stability and dynamic impact of a HVDC transmission system and compares the results to conventional high-voltage AC (HVAC) transmission systems via PSS/E simulation. This paper also examines the effect of HVDC system to voltage variation and low-frequency resonance in the neighboring buses in the grid using ESCR(Effective Short Circuit Ratio)과 UIF(Unit Interaction Factor) indices.

A Novel Phase Locked Loop for Grid-Connected Converters under Non-Ideal Grid Conditions

  • Yang, Long-Yue;Wang, Chong-Lin;Liu, Jian-Hua;Jia, Chen-Xi
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.216-226
    • /
    • 2015
  • Grid synchronization is one of the key techniques for the grid-connected power converters used in distributed power generation systems. In order to achieve fast and accurate grid synchronization, a new phase locked loop (PLL) is proposed on the basis of the complex filter matrixes (CFM) orthogonal signal generator (OSG) crossing-decoupling method. By combining first-order complex filters with relation matrixes of positive and negative sequence voltage components, the OSG is designed to extract specific frequency orthogonal signals. Then, the OSG mathematical model is built in the frequency-domain and time-domain to analyze the spectral characteristics. Moreover, a crossing-decoupling method is suggested to decouple the fundamental voltage. From the eigenvalue analysis point of view, the stability and dynamic performance of the new PLL method is evaluated. Meanwhile, the digital implementation method is also provided. Finally, the effectiveness of the proposed method is verified by experiments under unbalanced and distorted grid voltage conditions.

전기철도 급전시스템의 순시전압강하 보상을 위한 단상 배전 STATCOM의 적용 (Compensation of Instantaneous Voltage Drop at AC Railroad System with Single-Phase Distributed STATCOM)

  • 김준상;이승혁;김진오;이준경;정현수
    • 조명전기설비학회논문지
    • /
    • 제21권1호
    • /
    • pp.42-51
    • /
    • 2007
  • AC 전기철도 시스템은 동적 단상부하가 빠르게 변화하고, 전철 급전변전소에서 3상 전력을 단상 전력으로 변환한다. 이것은 일반 배전 시스템과 비교해서 AC 전기철도 시스템의 전기적인 현상들이 다르다는 것을 나타낸다. AC 전기철도 열차부하의 전기적인 특성은 동적부하의 운영과 운행 스케줄, 트랙의 구배 등에 따라 연속적인 변화를 받고 있다. 이와 같은 열차부하의 운영에 따른 급전거리가 길어 전압강하, 전압 불평형 및 고조파 왜곡현상 등의 전력 품질 저하요인이 발생하게 된다. 이러한 문제점은 상위계통인 송전시스템의 안정도에 악영향을 줄뿐만 아니라, 전기철도 급전시스템의 전력품질 저하, 전기철도차량의 통신장비, 운행 및 수송량 제한에도 영향을 미치게 된다. 따라서 본 논문에서는 전기철도시스템의 과도상태 평가를 위해 PSCAD/EMTDC를 이용한 평가모델을 제시하고, 전압 강하에 주안점을 두어, 전기철도 급전시스템의 말단 분기점(Sectioning Post)에 정지형 무효전력 보상장치인 단상 배전 STATCOM(Single-phase Static Synchronous Compensator)을 설치하여 그 작용에 따른 전압강하 보상을 평가하였다.

An Enhanced Power Sharing Strategy for Islanded Microgrids Considering Impedance Matching for Both Real and Reactive Power

  • Lin, Liaoyuan;Guo, Qian;Bai, Zhihong;Ma, Hao
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.282-293
    • /
    • 2017
  • There exists a strong coupling between real and reactive power owing to the complex impedances in droop based islanded microgrids (MGs). The existing virtual impedance methods consider improvements of the impedance matching for sharing of the voltage controlled power (VCP) (reactive power for Q-V droop, and real power for P-V droop), which yields a 1-DOF (degree of freedom) tunable virtual impedance. However, a weak impedance matching for sharing of the frequency controlled power (FCP) (real power for $P-{\omega}$ droop, and reactive power for $Q-{\omega}$ droop) may result in FCP overshoots and even oscillations during load transients. This in turn results in VCP oscillations due to the strong coupling. In this paper, a 2-DOF tunable adaptive virtual impedance method considering impedance matching for both real and reactive power (IM-PQ) is proposed to improve the power sharing performance of MGs. The dynamic response is promoted by suppressing the coupled power oscillations and power overshoots while realizing accurate power sharing. In addition, the proposed power sharing controller has a better parametric adaptability. The stability and dynamic performances are analyzed with a small-signal state-space model. Simulation and experimental results are presented to investigate the validity of the proposed scheme.