• 제목/요약/키워드: Dynamic voltage stability

검색결과 170건 처리시간 0.025초

An Inductance Voltage Vector Control Strategy and Stability Study Based on Proportional Resonant Regulators under the Stationary αβ Frame for PWM Converters

  • Sun, Qiang;Wei, Kexin;Gao, Chenghai;Wang, Shasha;Liang, Bin
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1110-1121
    • /
    • 2016
  • The mathematical model of a three phase PWM converter under the stationary αβ reference frame is deduced and constructed based on a Proportional-Resonant (PR) regulator, which can replace trigonometric function calculation, Park transformation, real-time detection of a Phase Locked Loop and feed-forward decoupling with the proposed accurate calculation of the inductance voltage vector. To avoid the parallel resonance of the LCL topology, the active damping method of the proportional capacitor-current feedback is employed. As to current vector error elimination, an optimized PR controller of the inner current loop is proposed with the zero-pole matching (ZPM) and cancellation method to configure the regulator. The impacts on system's characteristics and stability margin caused by the PR controller and control parameter variations in the inner-current loop are analyzed, and the correlations among active damping feedback coefficient, sampling and transport delay, and system robustness have been established. An equivalent model of the inner current loop is studied via the pole-zero locus along with the pole placement method and frequency response characteristics. Then, the parameter values of the control system are chosen according to their decisive roles and performance indicators. Finally, simulation and experimental results obtained while adopting the proposed method illustrated its feasibility and effectiveness, and the inner current loop achieved zero static error tracking with a good dynamic response and steady-state performance.

유전 알고리즘을 이용한 SVC 계통의 최적 PI 제어기 설계 (A Design of Optimal PI Controller of SVC System using Genetic Algorithms)

  • 정형환;허동렬;왕용필;한길만;김해재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권5호
    • /
    • pp.212-219
    • /
    • 2000
  • This paper deals with a systematic approach to GA-PI controller design for static VAR compensator(SVC) using genetic algorithms(GAs) which are search algorithms based on the mechanics of natural of natural selection and natural genetics, to improve system stability. A SVC, one of the Flexible AC Transmission System(FACTS), constructed by a fixed capacitor(FC) and a thyristor controlled reactor(TCR), is designed and implemented to improve the damping of a synchronous generator, as well as controlling the system voltage. To verify the robustness of the proposed method, considered dynamic response of generator used deviation and generator terminal voltage by applying a power fluctuation and three-phase fault at heavy load, normal load and light load. Thus, we proved usefulness of GA-PI controller design to improve the stability of single machine-infinite bus with SVC system.

  • PDF

전력시스템 동특성 해석을 위한 전압원 FACTS 기기의 Newton 전류 주입형 모델링에 관한 연구 (VSI FACTS Modeling Using Newton-Type Current Injection Method for Studying Power System Dynamics)

  • 박정수;손광명;장길수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권7호
    • /
    • pp.281-289
    • /
    • 2006
  • Advanced controllers among Flexible AC Transmission System(FACTS) devices employ self-commutated switching converters, VSI (Voltage Sourced Inverters), as the synchronous voltage source. Such controllers are SSSC (Static Synchronous Series Compensator), STATCOM (Static Synchronous Compensator) and UPFC (Unified Power Flow Controller). UPFC is series-shunt combined controller. Its series and shunt inverters can be modeled as SSSC and STATCOM but the dependant relation between the inverters is very complex. For that reason, the complexity makes it difficult to develop the UPFC model by simply combining the SSSC and STATOM models when we apply the model for conventional power system dynamic simulation algorithm. Therefore, we need each relevant models of VSI type FACTS devices for power system analysis. This paper proposes a modeling approach which can be applied to modeling of VSI type FACTS devices. The proposed method using Newton-type current injection method can be used to make UPFC, SSSC, and STATCOM models. The proposed models are used for 2-area test system simulation, and the results verify their effectiveness.

단상 UPS 인버터의 강인한 전압제어기 설계 (Design of Robust Voltage Controller for Single-phase UPS Inverter)

  • 구대관;지준근;차귀수;문준희
    • 전력전자학회논문지
    • /
    • 제16권4호
    • /
    • pp.317-325
    • /
    • 2011
  • 본 논문에서는 단상 UPS 인버터의 강인한 전압제어기를 제안하고 설계한다. 제안된 전압제어기는 부하 변동에 대해서 강인 안정성과 강인 추종 성능을 얻기 위해 ${\mu}$-합성에 기초한 강인 제어 이론을 이용하여 설계되었다. 설계된 전압제어기의 강인 제어 성능은 ${\mu}$-해석을 통해 이론적으로 확인하였다. 그리고 단상 인버터에 대해 선형 부하와 비선형 부하로 시뮬레이션 및 실험을 수행하여 제안된 전압제어기가 안정된 전압제어 성능과 빠른 동특성을 가지는 향상된 제어성능을 제공하는 것을 확인하였다.

TN 모드와 FFS 모드에서 Pretilt Angle이 전기 광학 특성 및 동력학 안정성에 미치는 영향에 관한 연구 (Study on Electro-optic Characteristics and Dynamic Stability Depending on the Pretilt Angle for the Twisted Nematic(TN) and Fringe-field Switching(FFS) Mode)

  • 김미숙;정연학;김향율;김서윤;이승희
    • 한국전기전자재료학회논문지
    • /
    • 제17권11호
    • /
    • pp.1234-1240
    • /
    • 2004
  • We studied on the electro-optic characteristics and dynamic stability according to an undesirably defined pretilt angle induced in high step coverage of pixel area for the Twisted Nematic (TN) / Fringe-Field Switching (FFS) mode. In case of the TN mode, LC directors twist reversely near the edges of thin-film-transistor and black matrix where the pretilt angle of the LC is not well defined. Therefore, the voltage-dependent dynamics of the LC in TN mode is unstable and shows the bad electro-optic characteristics. On the other hand, in case of the FFS mode, the LCs are twisted parallel to the bottom substrate by fringe electric field and the electro-optic characteristic is not influenced by the pretilt angle of the LC which is not well defined.

고속, 고해상도 CMOS 샘플 앤 홀드 회로 (High Speed, High Resolution CMOS Sample and Hold Circuit)

  • 김원연;박공순;박상욱;윤광섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 하계종합학술대회 논문집(2)
    • /
    • pp.545-548
    • /
    • 2004
  • The paper describes the design of high-speed, high-resolution Sample-and-Hold circuit which shows the conversion rate 80MHz and the power supply of 3.3v with 0.35um CMOS 2-poly 4-metal process for high-speed, high resolution Analog-to-Digital Converter. For improving Dynamic performance of Sample-and-Hold, Two Double bootstrap switch and high performance operational amplifier with gain booster, which are used. and For physical stability of Sample and Hold circuit, reduces excess voltage of gate in bootstrap switch. Simulation results using HSPICE shows the SFDR of 71dB, 75dB in conversion rate of 80MHz result for two inputs(0.5Vpp, 10MHz and 1Vpp, 10MHz) and the power dissipation of 48mW at single 3.3V supply voltage.

  • PDF

비선형 상호작용을 갖는 전력계통의 비선형 분산 전압제어 (Decentralized Nonlinear Voltage Control of Multimachine Power Systems with Non linear Interconnections)

  • 이재원;윤태웅;김광연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.47-50
    • /
    • 2003
  • For large-scale systems which are composed of interconnections of many lower-dimensional subsystems, decentralized control is preferable since it can alleviate the computational burden, avoid communication between different subsystems, and make the control more feasible and simpler. A power system is such a large-scale system where generators are interconnected through transmission lines. Decentralized control is therefore considered for power systems. In this paper, a robust decentralized excitation control scheme for interactions is proposed to enhance the transient stability of multimachine power systems. First we employ a DFL(Direct Feedback Linearization) compensator to rancel most of the nonlinearities; however, the resulting model still contains nonlinear interconnections. Therefore, we design a robust controller in order to deal with Interconnection terms. In this procedure, an upper bound of interconnection terms is estimated by an estimator. The resulting adaptive scheme guarantees the uniform ultimate boundedness of the closed-loop dynamic systems in the presence of the uncertainties.

  • PDF

비이송식 플라즈마 토치 구조에 따른 열 플라즈마 특성 시험 (An Experimental Analysis on the Thermal Plasma Characteristics to the Geometry in Non-Transferred Torch)

  • 정안목;전의식
    • 반도체디스플레이기술학회지
    • /
    • 제8권4호
    • /
    • pp.89-94
    • /
    • 2009
  • The influence on a stability of thermal plasma has been investigated in an electrode structure of non-transferred plasma torch. The variations of dynamic characteristic of the arc voltage was analyzed and compared in terms of voltage character and nozzle types for both the step-shaped nozzles and magnetic-approved cylindrical nozzle. From the experimental results, an electrode gap, flow rate of arc gas, and currents are considered as major operational parameters. As conclusion, it was assured that a torch with step-shaped nozzles of magnetic-approved type produce the stable plasma jet.

  • PDF

Stability and Performance Investigations of Model Predictive Controlled Active-Front-End (AFE) Rectifiers for Energy Storage Systems

  • Akter, Md. Parvez;Mekhilef, Saad;Tan, Nadia Mei Lin;Akagi, Hirofumi
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.202-215
    • /
    • 2015
  • This paper investigates the stability and performance of model predictive controlled active-front-end (AFE) rectifiers for energy storage systems, which has been increasingly applied in power distribution sectors and in renewable energy sources to ensure an uninterruptable power supply. The model predictive control (MPC) algorithm utilizes the discrete behavior of power converters to determine appropriate switching states by defining a cost function. The stability of the MPC algorithm is analyzed with the discrete z-domain response and the nonlinear simulation model. The results confirms that the control method of the active-front-end (AFE) rectifier is stable, and that is operates with an infinite gain margin and a very fast dynamic response. Moreover, the performance of the MPC controlled AFE rectifier is verified with a 3.0 kW experimental system. This shows that the MPC controlled AFE rectifier operates with a unity power factor, an acceptable THD (4.0 %) level for the input current and a very low DC voltage ripple. Finally, an efficiency comparison is performed between the MPC and the VOC-based PWM controllers for AFE rectifiers. This comparison demonstrates the effectiveness of the MPC controller.

퍼지형 전력계통안정화제어기의 실계통 적용 및 안정도 향상 (Application of Fuzzy-PSS to KEPCO power system and stability enhancement)

  • 최경선;이동인;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1052-1055
    • /
    • 1997
  • The importance of dynamic stability of power system is increasing as the excitation system using static type are greatly enlarged. There are several types of PSS at Present, Elements of PSS consist of Notch filter, lead-lag filter, washout limiter which are variable. The existing power system has a difficulty in determining the optimal PSS parameters whenever PSS is installed. And it is recommended to retune PSS parameters periodically because system characteristics change due to aging. In this paper, intelligent PSS using fuzzy concept is introduced to get over difficulties mentioned above. The usefulness of fuzzy-type PSS was verified by applying FPSS to KEPCO power system. Generally, the voltage regulation deteriorates if conventional PSS is applied because supplementary signal is added into AVR summing point to damp Power oscillation. In this paper this problem is solved by AVR limiter and fuzzy members tuning.

  • PDF