• Title/Summary/Keyword: Dynamic visual acuity

Search Result 15, Processing Time 0.027 seconds

Differences of Dynamic Visual Acuity According to Optical Lens Color (안경렌즈 색상에 따른 동체 시력의 변화)

  • Lee, Min-A;Kim, Young Ji;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.7-11
    • /
    • 2011
  • Purpose: The purpose of this study is to investigate the differences of dynamic visual acuity to color of optical lens. Methods: we measured dynamic visual acuity using 5 colored lenses (transparent, yellow, blue, green, brown) for 30 university students. Results: Dynamic visual acuity were highest on yellow colored lens and lowest on brown colored lens, for both of naked eyes and contact lens wearers. Conclusions: It can be concluded that optical lens color can influence on dynamic visual acuity. Selection of colour lense can enhance or decrease of dynamic visual acuity. Therefore, a selection of colour lense should be carefully decided especially for athletes who needs a good dynamic visual acuity.

Dynamic Visual Acuity and Dynamic Stereoacuity of Athletes and Nonathletes (운동선수와 대학생 남녀의 동체 시력 및 동적 입체시에 관한 비교 연구)

  • Lee, Min-A;Oh, Jae-Man;Jung, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.43-49
    • /
    • 2009
  • Purpose: The purpose of this study was to obtain the fundamental data of dynamic visual acuity and dynamic stereoacuity. Methods: The subjects were 20 athletes (high school baseball player) and 40 nonathletes (20 male, 20 female). We assessed static visual acuity, dynamic visual acuity, static stereoacuity and dynamic stereoacuity using rotating mirror projection system and computer program. Results: Three groups had similar static visual acuity and static stereoacuity. On the other hand, the dynamic visual acuity and dynamic stereoacuity showed statistically significant differency. The mean dynamic visual acuity for athletes was 174.80${\pm}$28.70 deg/sec, 137.10${\pm}$16.54 deg/sec for male nonathletes and 111.59${\pm}$15.40 deg/sec for female nonathletes. The mean dynamic stereoacuity for athlets was 234.55${\pm}$19.64, 249.05${\pm}$8.86 for male nonathletes and 247.10${\pm}$14.89 for female nonathletes. The group of athletes had better dynamic visual acuity and dynamic stereoacuity. Conclusions: If the result of this study apply to sports, it will be very useful to improve sports performance.

  • PDF

Implementation of dynamic visual acuity testing system using optical see through head mounted display

  • Son, Hojun;Yun, Deokyoung;Kim, Jungho;Lee, Seunghyun;Kwon, Soonchul
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.9 no.3
    • /
    • pp.70-77
    • /
    • 2017
  • Dynamic visual acuity is used as an important factor to measure athletic performance in sports field. A study on visual acuity testing system using non-see head mounted display (NST-HMD) was conducted recently. However, the NST-HMD has a problem that the sense of space felt by the subject differs from the actual environment. This is because the view is blocked so that it is only implemented in a virtual space. This paper proposes a dynamic visual acuity testing system using optical see through head mounted display (OST-HMD). To do this, OST-HMD and NST-HMD comparative tests were conducted using existing K-D (King-Devick) charts. Experiments were performed on 30 subjects and their visual acuity was measured and analyzed by parametric statistics and one-sample T-test. The results of the study demonstrate the effectiveness of the proposed OST-HMD. This study is expected to use the visual inspection and training equipment of OST-HMD.

The Effects of Sports Vision Training on Baseball Player's Visual Performance and Baseball Records (스포츠비젼 트레이닝이 시기능 및 야구성적에 미치는 영향)

  • Lee, Min-A;Oh, Jae-Man;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.87-97
    • /
    • 2010
  • Purpose: The purpose of this study is to investigate the effects of sports vision training on baseball player's visual performance and baseball records. Methods: All subjects were 21 males of high school baseball players, and they participated on eight weeks of sports vision training program. Pre- and post- test results were obtained for static and dynamic visual acuity, static and dynamic stereo acuity, distance and near phoria, fusional reserves, near point of convergence, contrast sensitivity, visual-reaction time. Results: Statical analysis indicated significant improvement in most of mentioned visual variables and baseball records (p<0.001). Conclusions: It can be concluded that the sports vision training program improves visual skills of baseball players, which could lead to improvement in the baseball records. Vison training will be a promotor for baseball player to enhance their performance if proper test instruments and training course is supplied.

Optical Design of an Inspection Apparatus for Dynamic Visual Acuity (동체시력 검사기의 광학계 설계)

  • Lee, Dong-Hee;Kim, Hye-Dong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.473-480
    • /
    • 2004
  • Recently, they are interested in the relation between night's vehicle accidents of drivers and the dynamic visual acuity at home and aboard. So, in this research, we tried to design an optical system of the inspection equipment to measure the dynamic visual acuity. A optotype standard did to Landolt's ring with 45mm of diameter and 9mm of gap to maintain the visual acuity of 1.0 in the 30m distance. An optical structure of the inspection equipment was composed of the sequence of an observer, a plus refraction lens system, a minus refraction lens system, and an optotype that was arranged to have characteristics that the size of the first virtual image of the optotype made by the minus refraction lens system grows bigger gradually according to the optotype movement to near distance from far distance, and also the first virtual image moves to the principle plane from the focal point of the plus refraction lens system as the size of the first virtual image arranged to the inside of focal distance of plus refraction lens system grows bigger gradually. As doing these processes, we completed the optical system of which characteristic is that the position of the final second virtual image moves to 3m from 50m as the size of the second virtual image made by the plus refraction lens system maintains to be regular.

  • PDF

A Study on the Measurement of Dynamic Visual Acuity according to the Change of Accommodative Stimulus (조절자극 변화에 따른 동체시력(Dynamic visual acuity) 측정에 관한 연구)

  • Jin, Moon-Seog;Jeon, In-Chul
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.523-530
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the difference in the dynamic visual acuity between (DVA) the distance and near and the effect of change of accommodative stimulus on the dynamic visual acuity by the addition of the plus lens. Methods : The study involved 40 male and female adults ($22.84{\pm}2.43$ years old) with over 1.0 of visual acuity and without systemic disease or ocular disease. We compared the distance and near DVA and the change of DVA induced by the addition of the plus lens(+0.50D, +1.00D, +1.50D). Results : The distance DVA and near DVA are $78.86{\pm}19.46deg/sec$ and $76.90{\pm}18.05deg/sec$ respectively. The distance DVA was slightly higher(p=0.04). The higher the distance DVA, the higher the positive correlation with the near DVA and distance DVA, and distance DVA was higher in those who had higher the near DVA(r=0.95, p=0.00, Fig. 4). The near DVA according to the change of accommodative stimulus was $75.95{\pm}18.85deg/sec$ in full correction and the near DVA with +0.50D spherical power was $76.95{\pm}16.45$ but there was no statistically significant differences(p>0.05). However, the near DVA with +1.00D spherical power was $79.02{\pm}13.51deg/sec$ and it was slightly higher. Also, the near DVA with +1.50D spherical power was $84.28{\pm}18.96deg/sec$, there and it was statistically significant difference(p<0.05). Conclusion : There is no difference between distance and near DVA, but near DVA is also excellent if distance DVA is good. The DVA increases as added a plus lens for controlled accommodative stimulation changes.

Effect of Visual Difference on Balance and Walking Capacity in Life Care of College Students (대학생의 라이프케어에서 시력 차이가 균형과 보행능력에 미치는 영향)

  • Yoon, Young-Jeoi
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.1
    • /
    • pp.191-197
    • /
    • 2021
  • This study studied the effect of visual difference on balance and walking ability in college students' life care. The study was conducted on 45 students attending H University in G City, divided into control groups (n=22, not wearing glasses and contact lenses) and experimental groups (n=23, wearing glasses and contact lenses). In not wearing glasses and contact lenses, the subjects measured visual acuity with logMAR charts, evaluated their balance ability with BIOrescue, and evaluated walking ability with G-Walk. The results of this study showed that the experimental group had statistically significantly lower vision than the control group in the visual acuity measurement(p<.01). Static balance ability was statistically significant increase in center of mass movement of the right foot in the experimental group compared to the control group(p<.05). Dynamic balance ability was statistically significantly reduce in limit of stability for groups of experiments compared to control group(p<.05). The walking ability was statistically significantly shorter on step length and stride length, swing of the experimental group compared to the control group in the right foot(p<.05). The findings showed that the visual difference in university students reduces balance and walking ability. Therefore, university students with poor visual acuity are recommended to correct of visual acuity to prevent collision and falls in their daily lives.

The Comparative Assessment of the KVA and Dynamic Stereoacuity (동적시력(KVA)과 동적 입체시의 비교 평가)

  • Kim, Young-Cheong;Shim, Hyun-Suk;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.519-525
    • /
    • 2014
  • Purpose: On this study, we investigated the relationship between the kinetic visual acuity (KVA) and the dynamic stereoacuity and the effects of anisometropia with measuring KVA and the dynamic stereoacuity. Methods: For 63 adults (male 30, female 33), KVA and the dynamic stereoacuity were measured by using the kinetic visual acuity tester (KOWA AS-4A) and the Howard-Dolman test (H-D test) at distance 2.5 m after conducted full correction of subjects' refractive error respectly. Results: The means of KVA were $0.49{\pm}0.25$ for total subjects, $0.58{\pm}0.26$ for male, $0.40{\pm}0.22$ for female, and LogMAD (Log minimum angle of displacement) dynamic stereoacuities were $1.27{\pm}0.44$($28.44{\pm}25.03sec$ of arc) for total subjects, $1.28{\pm}0.44$($28.23{\pm}23.34sec$ of arc) for male, $1.27{\pm}0.45$($28.63{\pm}26.83sec$ of arc) for female. KVA showed a statistically significant difference between male and female (p=0.00), but dynamic stereoacuity was no significant difference (p=0.97). No significant correlation was present between KVA and dynamic stereoacuity (r=0.03). Also there were no significant differences in the dynamic stereoacuity of the three group which were classified according to the low, middle, high range of KVA (p=0.99). The anisometropia were less than 1 D and over 1 D when divided into two groups, KVA and dynamic stereoacuity showed no significant difference between each (p=0.11, p=0.99). There was no significant correlation between anisometropia and KVA (r=0.33), dynamic stereoacuity (r=0.18) but the correlation between KVA and anisometropia revealed more higer than between dynamic stereoacuity and anisometropia. Conculsions: The KVA for adults showed a significant difference between male and female and male was higher than female for KVA. The dynamic stereoacuity due to the KVA, the KVA and dynamic stereoacuity due to anisometropia were not significant differences between each and also were not great correlations.

Time-dependent Changes of Visual Acuity After Alcohol Ingestion (음주 후 시간경과에 따른 시력의 변화)

  • Kim, Sang-Yoeb;Lee, Sun Haeng;Moon, Byeong-Yeon;Yu, Dong-Sik;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.59-62
    • /
    • 2008
  • Purpose: This study was designed to investigate the time-dependent changes of visual acuity after alcohol ingestion. Methods: Both the subjective and objective refraction, distant contrast sensitivity, and three needle tests were carried out at 1 and 3 hours after alcohol ingestion. Results: It was found that the degree of myoptization increased as the blood alcohol level increased in the range of average -0.25D ~ -0.35D when tested 1 and 3 hours after alcohol ingestion. Under the same test conditions the increase in blood alcohol resulted in the reduction in the function of dynamic stereopsis. However, the variation in contrast sensitivity was found to be insignificant for all spatial frequencies. Conclusions: The optician has to be well aware of the fact that alcohol could affect the visual acuity and functional tests, therefore inquiring of the alcohol ingestion prior to visual test can be necessary.

  • PDF

Enhanced High Contrast Image Rendering Method Using Visual Properties for Sharpness Perception (시각 선명도 감각 특성을 이용한 개선된 고명암 대비 영상 렌더링 기법)

  • Lee, Geun-Young;Lee, Sung-Hak;Kwon, Hyuk-Ju;Sohng, Kyu-Ik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.8
    • /
    • pp.669-679
    • /
    • 2013
  • When an image is converted from HDR (high dynamic range) to LDR (low dynamic range), a tone mapping process is the essential component. Many TMOs (tone mapping operators) have been motivated by human vision which has lower physical luminance range than that in real scene. The representative of human vision properties which motivate TMOs is the local adaptation. However, TMOs are ultimately compressing image information such as contrast, saturation, etc. and the compression causes defects in image quality. In this paper, in order to compensate the degradation of the image which is caused by TMOs, the visual acuity-based edge stop function is proposed for applying the property of human vision to base-detail separation. In addition, using CSF (contrast sensitivity function) which represents the relationship among spatial frequency, contrast sensitivity, and luminance, the sharpness filter is designed and adaptively applied to the detail layer in regard to surround luminance.