Two cases of dynamic lumbar spinal stenosis were identified by the authors using axial loaded magnetic resonance image (MRI). In both cases, the patients presented with neurogenic claudication but MRI in decumbency showed no definite pathologic condition associated with their symptoms. In contrast, axial loaded MRI demonstrated constrictive spinal stenosis and a significantly decreased dural sac caused by epidural fat buckling and thickening of the ligamentum flavum in both cases. In the second case, a more prominent disc protrusion was also demonstrated compared with decumbent MRI. After decompressive surgery, both patients had satisfactory outcomes. Axial loaded MRI can therefore give decisive information in dynamic spinal disorders by allowing simulation of an upright position.
Objective : The aim of the present study was to assess the safety and efficacy of the dynamic stabilization system in the treatment of degenerative spinal diseases. Methods : The study population included 20 consecutive patients (13 females, 7 males) with a mean age of $61{\pm}6.98$ years (range 46-70) who underwent decompression and dynamic stabilization with the Dynesys system between January 2005 and August 2006. The diagnoses included spinal stenosis with degenerative spondylolisthesis (9/20, 45%), degenerative spinal stenosis (5/20, 25%), adjacent segmental disease after fusion (3/20, 15%), spinal stenosis with degenerative scoliosis (2/20, 10%) and recurrent intervertebral lumbar disc herniation (1/20, 5%). All of the patients completed the visual analogue scale (VAS) and the Korean version of the Oswestry Disability Index (ODI). The following radiologic parameters were measured in all patients : global lordotic angles and segmental lordotic angles (stabilized segments, above and below adjacent segments). The range of motion (ROM) was then calculated. Results : The mean follow-up period was $27.25{\pm}5.16$ months (range 16-35 months), and 19 patients (95%) were available for follow-up. One patient had to have the implant removed. There were 30 stabilized segments in 19 patients. Monosegmental stabilization was performed in 9 patients (47.3%), 9 patients (47.3%) underwent two segmental stabilizations and one patient (5.3%) underwent three segmental stabilizations. The most frequently treated segment was L4-5 (15/30, 50%), followed by L3-4 (12/30, 40%) and L5-S1 (3/30, 10%). The VAS decreased from $8.55{\pm}1.21$ to $2.20{\pm}1.70$ (p<0.001), and the patients' mean score on the Korean version of the ODI improved from $79.58%{\pm}15.93%$ to $22.17%{\pm}17.24%$ (p<0.001). No statistically significant changes were seen on the ROM at the stabilized segments (p=0.502) and adjacent segments (above segments, p=0.453, below segments, p=0.062). There were no patients with implant failure. Conclusion : The results of this study show that the Dynesys system could preserve the motion of stabilized segments and provide clinical improvement in patients with degenerative spinal stenosis with instability. Thus, dynamic stabilization systems with adequate decompression may be an alternative surgical option to conventional fusion in selected patients.
목적: 요추부 척추관 협착증에서의 후방 감압술 시 극간인대 및 극상인대의 보존이 술 후 척추 불안정성의 예방에 미치는 영향에 대하여 밝히고자 했다. 대상 및 방법: 2014년 3월부터 2017년 3월까지 요추부 척추관 협착증에서 후방 감압술을 시행하고 1년 이상 추시관찰한 83명의 환자를 후향적으로 연구하였다. 대상자들을 수술의 종류에 따라 포트홀 감압술을 시행한 56명의 환자는 그룹 A로, 후궁 아전절제술을 시행한 27명의 환자는 그룹 B로 분류하였다. 임상적 결과를 평가하기 위해 Oswestry disability index (ODI), 요통과 방사통에 대한 시각통증점수(visual analogue scale, VAS), 신경성 간헐적 파행(neurogenic intermittent claudication, NIC) 전 보행거리가 수술 전후로 측정되었다. 영상의학적 결과를 평가하기 위해 수술 전 및 수술 후 매 6개월마다 직립상태에서 측면 및 굴곡-신전 단순 방사선 사진을 촬영해 전위 정도(slip percentage), 역동적 전위 정도(dynamic slip percentage), 각변위(angular displacement), 역동적 각변위(dynamic angular displacement)를 측정하였다. 결과: ODI (그룹 A에서 28.1에서 12.8로 호전; 그룹 B에서 27.3에서 12.3으로 호전), 요통에 대한 VAS (그룹 A에서 7.0에서 2.6로 호전; 그룹 B에서 7.7에서 3.2로 호전), 방사통에 대한 VAS (그룹 A에서 8.5에서 2.8로 호전; 그룹 B에서 8.7에서 2.9로 호전), 그리고 NIC 전 보행 거리(그룹 A에서 118.4 m에서 1,496.2 m로 증가; 그룹 B에서 127.6 m에서 1,481.6 m로 증가)는 두 그룹 모두에서 호전되었다. 다른 영상의학적 결과들에서 유의한 차이가 없었던 반면 역동적 각변위는 술 후 두 그룹간에 유의한 차이를 보였다(그룹 A에서 6.2°에서 6.7°로 증가; 그룹 B에서 6.5°에서 8.4°로 증가; p-value=0.019). 결론: 요추부 척추관 협착증에서의 후방 감압술시 극간인대 및 극상인대를 포함한 후방 인대의 제거는 술 후 역동적 각변위의 증가를 초래하며 후방 인대를 보존하는 포트홀(port-hole) 감압술을 통해 이를 예방할 수 있다.
Background: The effect of lumbar spinal stenosis (LSS) and peripheral vascular disease (PVD), which occurs with similar degenerative conditions, when seen together, has not been studied. The aim of this study is to examine and compare the relationship between pain, balance, disability, fear of falling, and kinesiophobia in LSS patients with intermittent vascular claudication (IVC). Methods: Seventy-two patients diagnosed with LSS using magnetic resonance imaging participated in this study. Thirty-five patients with IVC symptoms and showing vascular lesions by lower extremity venous and arterial Doppler ultrasonography imaging were included in the IVC-LSS group. The pain, static balance, dynamic balance, disability, fear of falling, and kinesiophobia were evaluated using the numeric rating scale, single leg stance test, Time Up and Go (TUG), the Oswestry Disability Index (ODI), Fall Efficacy Scale-International (FES-I), and Tampa Scale for Kinesiophobia (TSK), respectively. Results: Age and female sex were found to be higher in the IVC-LSS group (P = 0.024; P = 0.012). The IVC-LSS group had a shorter single leg stance time and TUG test duration, pain intensity, ODI, FES-I, and TSK scores were higher than patients with LSS (P = 0.001). Pain, fear of falling, and kinesiophobia were moderately correlated with disability in the IVC-LSS group. No relationship was found between pain and dynamic balance. Also, the pain was not related to kinesiophobia. Conclusions: The findings indicated that IVC causes loss of balance and an increase in pain, disability, fear of falling, and kinesophobia in patients with LSS.
Background: Since open Wiltse approach allows limited visualization for foraminal stenosis leading to an incomplete decompression, we report the short-term clinical and radiological results of unilateral biportal endoscopic foraminal decompression using $0^{\circ}$ or $30^{\circ}$ endoscopy with better visualization. Methods: We examined 31 patients that underwent surgery for neurological symptoms due to lumbar foraminal stenosis which was refractory to 6 weeks of conservative treatment. All 31 patients underwent unilateral biportal endoscopic far-lateral decompression (UBEFLD). One portal was used for viewing purpose, and the other was for surgical instruments. Unilateral foraminotomy was performed under guidance of $0^{\circ}$ or $30^{\circ}$ endoscopy. Clinical outcomes were analyzed using the modified Macnab criteria, Oswestry disability index, and visual analogue scale. Plain radiographs obtained preoperatively and 1 year postoperatively were compared to analyze the intervertebral angle (IVA), dynamic IVA, percentage of slip, dynamic percentage of slip (gap between the percentage of slip on flexion and extension views), slip angle, disc height index (DHI), and foraminal height index (FHI). Results: The IVA significantly increased from $6.24^{\circ}{\pm}4.27^{\circ}$ to $6.96^{\circ}{\pm}3.58^{\circ}$ at 1 year postoperatively (p = 0.306). The dynamic IVA slightly decreased from $6.27^{\circ}{\pm}3.12^{\circ}$ to $6.04^{\circ}{\pm}2.41^{\circ}$, but the difference was not statistically significant (p = 0.375). The percentage of slip was $3.41%{\pm}5.24%$ preoperatively and $6.01%{\pm}1.43%$ at 1-year follow-up (p = 0.227), showing no significant difference. The preoperative dynamic percentage of slip was $2.90%{\pm}3.37%$; at 1 year postoperatively, it was $3.13%{\pm}4.11%$ (p = 0.720), showing no significant difference. The DHI changed from $34.78%{\pm}9.54%$ preoperatively to $35.05%{\pm}8.83%$ postoperatively, which was not statistically significant (p = 0.837). In addition, the FHI slightly decreased from $55.15%{\pm}9.45%$ preoperatively to $54.56%{\pm}9.86%$ postoperatively, but the results were not statistically significant (p = 0.705). Conclusions: UBEFLD using endoscopy showed a satisfactory clinical outcome after 1-year follow-up and did not induce postoperative segmental spinal instability. It could be a feasible alternative to conventional open decompression or fusion surgery for lumbar foraminal stenosis.
Park, Seong-Cheol;Yoon, Sang-Hoon;Hong, Yong-Pyo;Kim, Ki-Jeong;Chung, Sang-Ki;Kim, Hyun-Jib
Journal of Korean Neurosurgical Society
/
제46권4호
/
pp.292-299
/
2009
Objective : Clinical and radiological results of posterior dynamic stabilization using interspinous U (ISU, $Coflex^{TM}$, Paradigm Spine $Inc.^{(R)}$, NY, USA) were analyzed in comparison with posterior lumbar interbody fusion (PLIF) in degenerative lumbar spinal stenosis (LSS). Methods : A retrospective study was conducted for a consecutive series of 61 patients with degenerative LSS between May 2003 and December 2005. We included only the patients completed minimum 24 months follow up evaluation. Among them, 30 patients were treated with implantation of ISU after decompressive laminectomy (Group ISU) and 31 patients were treated with wide decompressive laminectomy and posterior lumbar interbody fusion (PLIF; Group PLIF). We evaluated visual analogue scale (VAS) and Oswestry Disability Index (ODI) for clinical outcomes (VAS, ODI), disc height ratio disc height (DH), disc height/vertebral body length ${\times}100$), static vertebral slip (VS) and depth of maximal radiolucent gap between ISU and spinous process) in preoperative, immediate postoperative and last follow up. Results : The mean age of group ISU ($66.2{\pm}6.7$ years) was 6.2 years older than the mean age of group PLIF ($60.4{\pm}8.1$ years; p=0.003). In both groups, clinical measures improved significantly than preoperative values (p<0.001). Operation time and blood loss was significantly shorter and lower in group ISU than group PLIF (p<0.001). In group ISU, the DH increased transiently in immediate postoperative period ($15.7{\pm}4.5%{\rightarrow}18.6{\pm}5.9%$), however decreased significantly in last follow up ($13.8{\pm}6.6%$, p=0.027). Vertebral slip (VS) of spondylolisthesis in group ISU increased during postoperative follow-up ($2.3{\pm}3.3{\rightarrow}8.7{\pm}6.2$, p=0.040). Meanwhile, the postoperatively improved DH and VS was maintained in group PLIF in last follow up. Conclusion : According to our result, implantation of ISU after decompressive laminectomy in degenerative LSS is less invasive and provides similar clinical outcome in comparison with the instrumented fusion. However, the device has only transient effect on the postoperative restoration of disc height and reduction of slip in spondylolisthesis. Therefore, in the biomechanical standpoint, it is hard to expect that use of Interspinous U in decompressive laminectomy for degenerative LSS had long term beneficial effect.
In this study, a commercial fixation device, BioFlex, which was designed with shape memory alloy(SMA) for dynamic stabilization of spine was biomechanically evaluated. The finite element model of intact lumbar spine from L1 to S was developed using CT images. Also, low FE models of 2-level(L4-L5-S) and 3-level(L3-L4-L5-S) posteriori fixation using titanium(Ti) rod and BioFlex(SMA) rod. The rotations of bone segments in the intact model and four models were predicted. Although the rotations of the BioFlex fixation model were smaller than those of the intact model, they were relatively larger than those of Ti fixation. The present can be applied for not only evaluation of the stability of interbody fixator, but also development of new implant.
Park, Won Man;Kim, Chi Heon;Kim, Yoon Hyuk;Chung, Chun Kee;Jahng, Tae-Ahn
Journal of Korean Neurosurgical Society
/
제58권1호
/
pp.43-49
/
2015
Objective : $Dynesys^{(R)}$ is one of the pedicle-based dynamic lumbar stabilization systems and good clinical outcome has been reported. However, the cylindrical spacer between the heads of the screws undergoes deformation during assembly of the system. The pre-strain probably change the angle of instrumented spine with time and oblique-shaped spacer may reduce the pre-strain. We analyzed patients with single-level stabilization with $Dynesys^{(R)}$ and simulated oblique-shaped spacer with finite element (FE) model analysis. Methods : Consecutive 14 patients, who underwent surgery for single-level lumbar spinal stenosis and were followed-up more than 24 months (M : F=6 : 8; age, $58.7{\pm}8.0$ years), were analyzed. Lumbar lordosis and segmental angle at the index level were compared between preoperation and postoperative month 24. The von Mises stresses on the obliquely-cut spacer ($5^{\circ}$, $10^{\circ}$, $15^{\circ}$, $20^{\circ}$, $25^{\circ}$, and $30^{\circ}$) were calculated under the compressive force of 400 N and 10 Nm of moment with validated FE model of the L4-5 spinal motion segment with segmental angle of $16^{\circ}$. Results : Lumbar lordosis was not changed, while segmental angle was changed significantly from $-8.1{\pm}7.2^{\circ}$ to $-5.9{\pm}6.7^{\circ}$ (p<0.01) at postoperative month 24. The maximum von Mises stresses were markedly decreased with increased angle of the spacer up to $20^{\circ}$. The stress on the spacer was uneven with cylindrical spacer but it became even with the $15^{\circ}$ oblique spacer. Conclusion : The decreased segmental lordosis may be partially related to the pre-strain of Dynesys. Further clinical and biomechanical studies are required for relevant use of the system.
Coe, Jeffrey D.;Kitchel, Scott H.;Meisel, Hans Jorg;Wingo, Charles H.;Lee, Soo-Eon;Jahng, Tae-Ahn
Journal of Korean Neurosurgical Society
/
제51권6호
/
pp.343-349
/
2012
Objective : Pedicle-based dynamic stabilization systems, in which semi-rigid rods or cords are used to restrict or control spinal segmental motion, aim to reduce or eliminate the drawbacks associated with rigid fusion. In this study, we analyzed the two-year clinical outcomes of patients treated with the NFlex (Synthes Spine, Inc.), a pedicle-based dynamic stabilization system. Methods : Five sites participated in a retrospective study of 72 consecutive patients who underwent NFlex stabilization. Of these 72 patients, 65 were available for 2-year follow-up. Patients were included based on the presence of degenerative disc disease (29 patients), degenerative spondylolisthesis (16 patients), lumbar stenosis (9 patients), adjacent segment degeneration (6 patients), and degenerative lumbar scoliosis (5 patients). The clinical outcome measures at each assessment were Visual Analogue Scale (VAS) to measure back pain, and Oswestry Disability Index (ODI) to measure functional status. Radiographic assessments included evidence of instrumentation failure or screw loosening. Results : Sixty-five patients (26 men and 39 women) with a mean age of 54.5 years were included. Mean follow-up was 25.6 months. The mean VAS score improved from 8.1 preoperatively to 3.8 postoperatively, representing a 53% improvement, and the ODI score from 44.5 to 21.8, representing a 51% improvement. Improvements in pain and disability scores were statistically significant. Three implant-related complications were observed. Conclusion : Posterior pedicle-based dynamic stabilization using the NFlex system seems effective in improving pain and functional scores, with sustained clinical improvement after two years. With appropriate patient selection, it may be considered an effective alternative to rigid fusion.
Kim, Ho Jung;Bak, Koang Hum;Chun, Hyoung Joon;Oh, Suck Jun;Kang, Tae Hoon;Yang, Moon Sool
Journal of Korean Neurosurgical Society
/
제52권4호
/
pp.359-364
/
2012
Objective : Transpedicular screw fixation has some disadvantages such as postoperative back pain through wide muscle dissection, long operative time, and cephalad adjacent segmental degeneration (ASD). The purposes of this study are investigation and comparison of radiological and clinical results between interspinous fusion device (IFD) and pedicle screw. Methods : From Jan. 2008 to Aug. 2009, 40 patients underwent spinal fusion with IFD combined with posterior lumbar interbody fusion (PLIF). In same study period, 36 patients underwent spinal fusion with pedicle screw fixation as control group. Dynamic lateral radiographs, visual analogue scale (VAS), and Korean version of the Oswestry disability index (K-ODI) scores were evaluated in both groups. Results : The lumbar spine diseases in the IFD group were as followings; spinal stenosis in 26, degenerative spondylolisthesis in 12, and intervertebral disc herniation in 2. The mean follow up period was 14.24 months (range; 12 to 22 months) in the IFD group and 18.3 months (range; 12 to 28 months) in pedicle screw group. The mean VAS scores was preoperatively $7.16{\pm}2.1$ and $8.03{\pm}2.3$ in the IFD and pedicle screw groups, respectively, and improved postoperatively to $1.3{\pm}2.9$ and $1.2{\pm}3.2$ in 1-year follow ups (p<0.05). The K-ODI was decreased significantly in an equal amount in both groups one year postoperatively (p<0.05). The statistics revealed a higher incidence of ASD in pedicle screw group than the IFD group (p=0.029) Conclusion : Posterior IFD has several advantages over the pedicle screw fixation in terms of skin incision, muscle dissection and short operative time and less intraoperative estimated blood loss. The IFD with PLIF may be a favorable technique to replace the pedicle screw fixation in selective case.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.