• Title/Summary/Keyword: Dynamic lens

Search Result 83, Processing Time 0.026 seconds

Smart Tourism Capability Maturity Framework : A Design Science Research Approach

  • Chaeyoung Lim;Kazuki Baba;Junichi Iijima
    • Asia pacific journal of information systems
    • /
    • v.29 no.3
    • /
    • pp.503-523
    • /
    • 2019
  • Many cities in the world have increased initiative to realize smart tourism. There are unexplored challenges for the people which lead and manage smart tourism projects and realize its value in tourism (we call them as 'Smart tourism initiatives'), such as orchestrating of tourism complexity, developing and sharing tourism strategy, sustaining tourism projects and innovation. Concerning these challenges, we aim to design a holistic capability maturity model for sustainable and smart tourism governance enabling sustainable tourism innovations via tackling the challenges above. We adopted Dynamic capability theory as a theoretical lens and introduced Design science research methodology in order to develop a new capability maturity governance model as a design artifact. As a result of the study, we could synthesize findings from iterations of the design research cycle based on the IT Capability Maturity Model. Our result proposes a potential capability maturity model supporting effective communication and strategic alignment for the initiatives with illuminating future paths with evaluation methods on tourism capabilities for the initiatives. Throughout this study, we contribute to the body of knowledge as well as practice by proposing a new tourism capability governance model.

Characterization of Electro-wetting Velocity by Measuring Transmission Intensity (광량 측정을 통한 전자습윤 현상의 동작 특성 평가)

  • Park, Seung-Ryong;Song, Seok-Ho;Oh, Cha-Hwan;Kim, Pill-Soo;Oh, Byoung-Do;Chung, Sang-Kug
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.4
    • /
    • pp.347-353
    • /
    • 2006
  • The electro-wetting effect can be implemented as a fast means to move liquid interfaces. A continuous and numerical method would be required in measurement of electro-wetting liquid interfaces. We propose an /in-situ/ measurement method to characterize the dynamic change in curvature of liquid interfaces. In the proposed method, variation of light intensity transmitted through the liquid interfaces is measured, leading to numerical determination of the liquid curvatures. Experimental results obtained from our efficient method are confirmed by the direct images of a streak camera.

Three Dimensional Reconstruction of Cellular Structure in Drosophila Retina Using High Voltage Electron Microscopy (초고압전자현미경을 이용한 초파리 망막 세포의 3차원 구조)

  • Mun, Ji-Young;Lee, Kyung-Eun;Han, Sung-Sik
    • Applied Microscopy
    • /
    • v.39 no.2
    • /
    • pp.185-189
    • /
    • 2009
  • Studies about the structure of Drosophila melanogaster retinal cell using electron microscopy have been carried out in details since 1960s. However, these results can have limitations in functional research because of two-dimensional structure. In this study, the adult retina of Drosophila melanogaster was investigated by employing high pressure freezing method, serial sections, high voltage electron microscopy, and 3-dimensional reconstruction method. From there results, mitochondria, microtubules, and nuclei were reconstructed as 3-dimensional structure using IMOD program. The 3D structure of these organelles showed that mitochondira mainly located in distal region near lens, and microtubule mainly located in distal and basal region. The 3D reconstruction of these organelles can be used for a critical evaluation in the dynamic change of cellular organelles caused by functional abnormality like retinal degeneration.

Stereoscopic Camera with a CCD and Two Zoom Lenses (단일 CCD와 두개의 줌렌즈로 구성한 입체 카메라)

  • Lee, Sang-Eun;Jo, Jae-Heung;Jung, Eui-Min;Lee, Kag-Hyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.38-46
    • /
    • 2006
  • The stereoscopic camera based on the image formation principle on human eyes and the brain is designed and fabricated by using a CCD and two zoom lenses. As two zoom lenses are separated as 65 mm of the human ocular distance with the wide angle of view of $50^{\circ}$ and the variable convergence angle from $0^{\circ}$ to $16^{\circ}$, the camera can be operated by the similar binocular parallax as human eyes. In order to take the dynamic stereoscopic picture, a shutter blade for the selection of the left and right images in turns, an X-cube image combiner fur the composition of these two images through the blade, and a CCD with 60 frames per second are used.

Magnetic Sector SIMS의 Sample Holder 위치에 따르는 RSF (Relative Sensitivity Factor) 변화 검증

  • 홍성윤;이종필;홍태은;윤명노;민경열;이순영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.192-192
    • /
    • 1999
  • SIMS(Secondary Ion Mass Spectrometry)는 다른 표면 분석장비와 비교하여^g , pp m,^g , pp b 단위의 미량분석이 가능한 장비로서, 특히 depth Profiling을 위한 dynamic SIMS는 Mass Spectrometer의 종류에 따라 Quadrupole SIMS (Q-SIMS)와, Magnetic Sector SIMS (M-SIMS)로 분류된다. 한편, Q-SIMS와 달리 M-SIMS의 경우, Transmission을 높여 주기 위해 Sample Holder에 수 keV의 bias를 걸어 주는데, 이로 인하여 분석 원소에 대한 Sensitivity가 향상되어 지는 반면, RSF의 변화와 같은 분석상의 Artifact가 발생하게 된다. 일반적으로 Q-SIMS의 경우에는 RSF의 RSD(Relative Standard Deviation)가 1%이내에서 보고되고 있지만 M-SIMS에 있어서는 이러한 Deviation이 M-SIMS보다 크게 나타난다. 이 차이는 주로 Sample Holder와 Immersion Lens 사이에 형성되는 Magnetic Field의 왜곡과 Spectrometer의 문제로부터 발생한다. 본 논문에서는 Sample Holder의 종류 및 holder so window 위치에 따라 RSF의 차이를 측정하고 그 data를 RS/1 통계 Package를 이용하여 계량적으로 검증하였으며, 그 차이의 원인과 대책을 제시하고자 한다. 실험에 사용된 Sample은 Si(100) p-type Wafer에 Boron을 이온 주입하여 제작하였다. 이온 주입 장비는 Varian E-500HP이며, 5.0E13 ions/cm2의 dose양을 80keV의 Energy로 각각 7도와 22도의 Tilt와 Twist Angle로 이온 주입을 하였다. SIMS분석에 사용된 Sample Holder는 각각 3 Hole, 9 Hole Type HOlder이며, 분석은 Cameca IMS-6f를 사용하여 B에 대한 Matrix Peak으로 28Si++를 얻었다. 실험 결과 3 Hole Type Sample Holder의 경우 RSF의 RSD는 5.84%, 9Hle Type Sample Holder의 경우는 14.3%로 나타났으나 분석 Window의 위치에 따르는 Grouping을 실시한 결과, 3 Hole Type Sample Holder의 경우 1.2%, 9Hole Type Sample Holder의 경우 9.8%로 RSF의 변화가 감소하였다. 이러한 Deviation은 Sample Holder를 Mount시킬 때 세 개의 Screw를 이용하여 Immersion Lens와의 평형을 잡아주기 때문에 발생하며, 이 Munting을 정확히 해줌으로써 RSF의 변화를 줄일 수 있으나, 실제로 완벽한 Mounting이 불가능하기 때문에 RSF를 일정하게 하기 위해서는 Sample Holder so Window의 취치를 일정하게 설정한 후 분석을 실시해야 한다고 판단된다.

  • PDF

Application of Isolation System to the Lighthouse Structure (등대구조물의 면진시스템 적용방안 연구)

  • Hur, Moo Won;Chun, Young Soo;Kim, Dong Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.27-36
    • /
    • 2013
  • In this study, seismic isolation technology to the lighthouse structure is suggested and isolation effects on response reduction are studied for three types of isolation models with the proposed seismic isolation technology. A seismic isolation system is installed on the base of the lighthouse structure in model 1, on the base of the lighthouse lens in model 2, and on the base of both of them in model 3. The dynamic time history analysis verifies that in case of model 1, the earthquake loading is greatly reduced and the accelerations of superstructure are greatly reduced. Also, the inter-story drifts are very small and can be neglected. The isolated model is in translational state and can be seen as a rigid whole. as a results, model 1 is very effective to mitigate the influence of earthquake on structures. In model 2, isolation effects are valid but special care should be taken to failure of the non-isolated lighthouse sub-structure. In model 3, isolation effects are also valid but the effects are small. model 3 is less effective than model 1.

A Study on Polyamide-6 Sintering and Effect by $CO_2$ Laser ($CO_2$ Laser에 의한 Polyamide-6 소결과 그 영향에 관한 연구)

  • Bae S.W.;Kim D.S.;Ahn Y.J.;Kim H.I.;Choi K.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.197-198
    • /
    • 2006
  • In the solid freeform fabrication (SFF) system using selective laser sintering (SLS), polyamide-12 powder is currently recognized as general material. In this study, some kinds of polyamide-6 powders with different shape and particlesize were fabricated to investigate the formability, the microstructure and mechanical properties. Also, to develop a more elaborate and rapid system, this study employs a new SLS device with a 3-axis dynamic focusing scanner system instead of the existing fe lens used in commercial SLS. Polyamide-6 powders having the average size of 100 m were treated thermally in order to keep the spherical symmetry in shape. These polyamide-6 powders were mixed with polyamide-12 powders having the average size of 50 m to give the bimodal distribution of size. These mixed powders showed the better fabrication in the selective laser sintering process because the smaller particles of polyamide-11 played an important role in the compact packing of powders by filling the void space between the large particles of polyamide-6. Also, Experiments have performed to evaluate the effect of a scanning path and sintering parameters by fabricating the various 3D objects.

  • PDF

Development of Hand-held OCT probe for Ophthalmic Imaging (안구 영상을 위한 OCT용 손잡이 형 프로브의 개발)

  • Cho, Nam-Hyun;Jung, Woong-Gyu;Jung, Un-Sang;Sephen, A.Boppart;Shim, Jae-Hoon;Kim, Jee-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.1
    • /
    • pp.24-30
    • /
    • 2011
  • We have developed a hand-held probe for an ophthalmic OCT system. The hand-held probe for imaging was designed to be compact and portable. The cornea and retinal images were acquired by replacing the objective lens at the front of the probe. To verify the performance of the hand-held OCT probe, we acquired two dimensional OCT image of the rat eye in vivo and reconstructed three dimensional rat eye rendering images. In vivo 3D OCT images were showed distinct structural information in the posterior and anterior chamber with minimal motion artifacts. Thereby, OCT imaging speed is suitable for an dynamic in vivo experiment.

Physical principles of digital radiographic imaging system (디지털 방사선영상 시스템의 기본적 원리)

  • Choi, Jin-Woo;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.

The Camera Calibration Parameters Estimation using The Projection Variations of Line Widths (선폭들의 투영변화율을 이용한 카메라 교정 파라메터 추정)

  • Jeong, Jun-Ik;Moon, Sung-Young;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2372-2374
    • /
    • 2003
  • With 3-D vision measuring, camera calibration is necessary to calculate parameters accurately. Camera calibration was developed widely in two categories. The first establishes reference points in space, and the second uses a grid type frame and statistical method. But, the former has difficulty to setup reference points and the latter has low accuracy. In this paper we present an algorithm for camera calibration using perspective ratio of the grid type frame with different line widths. It can easily estimate camera calibration parameters such as focal length, scale factor, pose, orientations, and distance. But, radial lens distortion is not modeled. The advantage of this algorithm is that it can estimate the distance of the object. Also, the proposed camera calibration method is possible estimate distance in dynamic environment such as autonomous navigation. To validate proposed method, we set up the experiments with a frame on rotator at a distance of 1,2,3,4[m] from camera and rotate the frame from -60 to 60 degrees. Both computer simulation and real data have been used to test the proposed method and very good results have been obtained. We have investigated the distance error affected by scale factor or different line widths and experimentally found an average scale factor that includes the least distance error with each image. It advances camera calibration one more step from static environments to real world such as autonomous land vehicle use.

  • PDF