Wide Dynamic Range CMOS Image Sensor with Adjustable Sensitivity Using Cascode MOSFET and Inverter

  • Seong, Donghyun;Choi, Byoung-Soo;Kim, Sang-Hwan;Lee, Jimin;Shin, Jang-Kyoo
    • 센서학회지
    • /
    • 제27권3호
    • /
    • pp.160-164
    • /
    • 2018
  • In this paper, a wide dynamic range complementary metal-oxide-semiconductor (CMOS) image sensor with the adjustable sensitivity by using cascode metal-oxide-semiconductor field-effect transistor (MOSFET) and inverter is proposed. The characteristics of the CMOS image sensor were analyzed through experimental results. The proposed active pixel sensor consists of eight transistors operated under various light intensity conditions. The cascode MOSFET is operated as the constant current source. The current generated from the cascode MOSFET varies with the light intensity. The proposed CMOS image sensor has wide dynamic range under the high illumination owing to logarithmic response to the light intensity. In the proposed active pixel sensor, a CMOS inverter is added. The role of the CMOS inverter is to determine either the conventional mode or the wide dynamic range mode. The cascode MOSFET let the current flow the current if the CMOS inverter is turned on. The number of pixels is $140(H){\times}180(V)$ and the CMOS image sensor architecture is composed of a pixel array, multiplexer (MUX), shift registers, and biasing circuits. The sensor was fabricated using $0.35{\mu}m$ 2-poly 4-metal CMOS standard process.

An Adaptive Tone Reproduction for High Dynamic Range Image

  • Lee, Joo-Hyun;Jeon, Gwang-Gil;Jeon, Je-Chang
    • 방송공학회논문지
    • /
    • 제14권4호
    • /
    • pp.428-437
    • /
    • 2009
  • A high dynamic range (HDR) image can represent real world scenes that have a wide range of luminance intensity. However, compared with the range of real world luminance, conventional display devices have a low dynamic range (LDR). To display HDR images onto conventional displayable devices such as monitors and printers, we propose the logarithmic based global reproduction algorithm that considers the features of the image using reproduction parameters. Based on the characteristics of the image, we first modify the input luminance values for reproducing perceptually tuned images and then obtain the displayable output values directly. The experimental results show that the proposed algorithm achieves good subjective results while preserving details of the image; furthermore, the proposed algorithm has a fast, simple and practical structure for implementation.

Logarithmic Tone Mapping for High Dynamic Range Imaging

  • Lee, Joo-Hyun;Jeon, Gwang-Gil;Jeong, Je-Chang
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2009년도 IWAIT
    • /
    • pp.154-157
    • /
    • 2009
  • High dynamic range image can describe the real world scenes that have a wide range of luminance intensity. To display high dynamic range (HDR) image into conventional displayable devices such as monitors and printers, we proposed the logarithmic based global mapping algorithm that consider the features of image using mapping parameters. Based on characteristics of image, we first modify input luminance values for reproducing perceptually tuned images and then displayable output values are obtained directly. The experimental results show that the proposed algorithm achieves good subjective results while preserving details of image, furthermore proposed algorithm has fast simple and practical structure for implementation.

  • PDF

조명 조건에 강건한 스마트폰 카메라 맥박 측정을 위한 다이내믹 레인지 재구성 알고리즘 (Dynamic Range Reconstruction Algorithm for Smart Phone Camera Pulse Measurement Robust to Light Condition)

  • 박상욱;차경래
    • 대한임베디드공학회논문지
    • /
    • 제10권1호
    • /
    • pp.1-6
    • /
    • 2015
  • Recently, handy pulse measurement method was introduced by using smart phone camera. However, measured values are not consistent with the variations of external light conditions, because the external light interfere with dynamic range of captured pulse image. Thus, adaptive dynamic range reconstruction algorithm is proposed to conduct pulse measurement robust to light condition. The minimum and maximum values for dynamic ranges of green and blue channels are adjusted to appropriate values for pulse measurement. In addition, sigmoid function based curve is applied to adjusted dynamic range. Experimental results show that the proposed algorithm conducts suitably dynamic range reconstruction of pulse image for the interference of external light sources.

Adaptive local histogram modification method for dynamic range compression of infrared images

  • Joung, Jihye
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권6호
    • /
    • pp.73-80
    • /
    • 2019
  • In this paper, we propose an effective dynamic range compression (DRC) method of infrared images. A histogram of infrared images has narrow dynamic range compared to visible images. Hence, it is important to apply the effective DRC algorithm for high performance of an infrared image analysis. The proposed algorithm for high dynamic range divides an infrared image into the overlapped blocks and calculates Shannon's entropy of overlapped blocks. After that, we classify each block according to the value of entropy and apply adaptive histogram modification method each overlapped block. We make an intensity mapping function through result of the adaptive histogram modification method which is using standard-deviation and maximum value of histogram of classified blocks. Lastly, in order to reduce block artifact, we apply hanning window to the overlapped blocks. In experimental result, the proposed method showed better performance of dynamic range compression compared to previous algorithms.

An Optimal Combination of Illumination Intensity and Lens Aperture for Color Image Analysis

  • Chang, Y. C.
    • Agricultural and Biosystems Engineering
    • /
    • 제3권1호
    • /
    • pp.35-43
    • /
    • 2002
  • The spectral color resolution of an image is very important in color image analysis. Two factors influencing the spectral color resolution of an image are illumination intensity and lens aperture for a selected vision system. An optimal combination of illumination intensity and lens aperture for color image analysis was determined in the study. The method was based on a model of dynamic range defined as the absolute difference between digital values of selected foreground and background color in the image. The role of illumination intensity in machine vision was also described and a computer program for simulating the optimal combination of two factors was implemented for verifying the related algorithm. It was possible to estimate the non-saturating range of the illumination intensity (input voltage in the study) and the lens aperture by using a model of dynamic range. The method provided an optimal combination of the illumination intensity and the lens aperture, maximizing the color resolution between colors of interest in color analysis, and the estimated color resolution at the combination for a given vision system configuration.

  • PDF

동적 프로그래밍을 이용한 특징점 정합 (Matching Of Feature Points using Dynamic Programming)

  • 김동근
    • 정보처리학회논문지B
    • /
    • 제10B권1호
    • /
    • pp.73-80
    • /
    • 2003
  • 본 논문에서는 기준영상과 탐색영상 사이의 대응되는 특징 점을 정합 하는 알고리즘을 제안한다. 두 영상에서 특징 점을 찾기 위하여 Harris의 코너 점 검출기를 사용하였다. 기준영상의 각 특징 점에 대해, 정규상관계수가 임계치 이상인 탐색영상의 특징 점들로 후보 정합 점을 구한다. 최종적으로 동적 프로그래밍을 사용하여 후보 정합 점들 중에서 대응되는 특징 점을 구한다. 실험으로 인위적인 영상과 실제 영상에서 특징 점을 정합 하는 결과를 보였다.

Evaluation of Various Tone Mapping Operators for Backward Compatible JPEG Image Coding

  • Choi, Seungcheol;Kwon, Oh-Jin;Jang, Dukhyun;Choi, Seokrim
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권9호
    • /
    • pp.3672-3684
    • /
    • 2015
  • Recently, the standardization of backward compatible JPEG image coding for high dynamic range (HDR) image has been undertaken to establish an international standard called "JPEG XT." The JPEG XT consists of two layers: the base layer and the residual layer. The base layer contains tone mapped low dynamic range (LDR) image data and the residual layer contains the error signal used to reconstruct the HDR image. This paper gives the result of a study to evaluate the overall performance of tone mapping operators (TMOs) for this standard. The evaluation is performed using five HDR image datasets and six TMOs for profiles A, B, and C of the proposed JPEG XT standard. The Tone Mapped image Quality Index (TMQI) and no reference image quality assessment (NR IQA) are used for measuring the LDR image quality. The peak signal to noise ratio (PSNR) is used to evaluate the overall compression performance of JPEG XT profiles A, B, and C. In TMQI and NR IQA measurements, TMOs using display adaptive tone mapping and adaptive logarithmic mapping each gave good results. A TMO using adaptive logarithmic mapping gave good PSNRs.

동적 계획법을 이용한 스테레오 대응 알고리즘 (Stereo Correspondence Algorithm Using Dynamic programming)

  • 이충환;홍석교
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.310-310
    • /
    • 2000
  • The main problem in stereo vision is to find corresponding points in left and right image known as correspondence problem. Once correspondences determined, the depth information of those points are easily computed form the pairs of points in both image. In this paper, dynamic programming considering half-occluded region is used fer solving correspondence problem.

  • PDF

임상적용을 위한 핵의학 동적 심장팬텀의 구현 (Implementation of Nuclear Medicine Dynamic Cardiac Phantom for Clinical Application)

  • 이주영;박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권1호
    • /
    • pp.53-59
    • /
    • 2019
  • In the field of nuclear medicine, the various static phantoms of international standards are used to assess the performance of the nuclear medicine equipment. However, we only reproduced a fixed situation in spite of the movement of the cardiac, and the demands for dynamic situations have been continuously raised. More research is necessary to address these challenges. This study used flexible materials to design the dynamic cardiac phantom, taking into account the various clinical situations. It also intended to reproduce the images through dynamic cardiac flow to confirm the usefulness of the proposed technique. The frame of dynamic cardiac phantom was produced based on the international standard phantom. A nuclear medicine dynamic cardiac phantom was produced rubber material and silicone implemented by 3D printing technique to reproduce endocardium and epicardium movement. Therefore we compared and evaluated the image of a cardiac phantom made of rubber material and a cardiac phantom made of silicone material by 3D printing technique. According to the results of this study, the analysis of the Summed Rest Score(SRS) showed abnormalities in the image of a cardiac phantom made of rubber material at 10, 20, and 30 stroke rates, but the image of a cardiac phantom made of silicone material by 3D printing technique showed normal levels. And the analysis of the Total Perfusion Deficit(TPD) showed that TPD in the image of a cardiac phantom made of rubber material was higher than that of the image of a cardiac phantom made of silicone material by 3D printing technique at 10, 20, and 30 stroke rates. The potential for clinical application of the proposed method was confirmed in the dynamic cardiac phantom implemented with 3D printing technique. It is believed that the objective information secures the reliability of inspection equipment and it contributes to improve the diagnostic value of nuclear medicine.