• 제목/요약/키워드: Dynamic diagnosis

검색결과 362건 처리시간 0.029초

Dynamic Susceptibility Contrast (DSC) Perfusion MR in the Prediction of Long-Term Survival of Glioblastomas (GBM): Correlation with MGMT Promoter Methylation and 1p/19q Deletions

  • Kwon, Yong Wonn;Moon, Won-Jin;Park, Mina;Roh, Hong Gee;Koh, Young Cho;Song, Sang Woo;Choi, Jin Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권3호
    • /
    • pp.158-167
    • /
    • 2018
  • Purpose: To investigate the surgical, perfusion, and molecular characteristics of glioblastomas which influence long-term survival after treatment, and to explore the association between MR perfusion parameters and the presence of MGMT methylation and 1p/19q deletions. Materials and Methods: This retrospective study was approved by our institutional review board. A total 43 patients were included, all with pathologic diagnosis of glioblastoma with known MGMT methylation and 1p/19q deletion statuses. We divided these patients into long-term (${\geq}60\;months$, n = 7) and short-term (< 60 months, n = 36) survivors, then compared surgical extent, molecular status, and rCBV parameters between the two groups using Fisher's exact test or Mann-Whitney test. The rCBV parameters were analyzed according to the presence of MGMT methylation and 1p/19q deletions. We investigated the relationship between the mean rCBV and overall survival using linear correlation. Multivariable linear regression was performed in order to find the variables related to overall survival. Results: Long-term survivors (100% [7 of 7]) demonstrated a greater percentage of gross total or near total resection than short-term survivors (54.5% [18 of 33]). A higher prevalence of 1p/19q deletions was also noted among the long-term survivors (42.9% [3 of 7]) than the short-term survivors (0.0% [0 of 36]). The rCBV parameters did not differ between the long-term and short-term survivors. The rCBV values were marginally lower in patients with MGMT methylation and 1p/19q deletions. Despite no correlation found between overall survival and rCBV in the whole group, the short-term survivor group showed negative correlation ($R^2=0.181$, P = 0.025). Multivariable linear regression revealed that surgical extent and 1p/19q deletions, but not rCBV values, were associated with prolonged overall survival. Conclusion: While preoperative rCBV and 1p/19q deletion status are related to each other, only surgical extent and the presence of 1p/19q deletion in GBM patients may predict long-term survival.

Imaging Plate를 이용한 극저준위 방사능 측정에 관한 연구 (Development of the Measurement Method of Extremely Low Level Activity with Imaging Plate)

  • 곽지연;이경범;이종만;박태순;오필제;이민기;서지숙;황한열
    • Journal of Radiation Protection and Research
    • /
    • 제29권4호
    • /
    • pp.231-236
    • /
    • 2004
  • 시료중의 방사능 분포를 영상으로 획득할 수 있는 2차원 디지털 방사선 검출기인 Imaging Plate(IP) 검출기는 주로 산업용 라디오그라피, 의료진단, X-선 회절실험 등에서도 광범위하게 사용되고 있다. 본 연구에서는 IP 검출기의 여러 종류의 방사선에 대한 높은 감도 우수한 공간 분해능, 넓은 선형범위와 스크린의 높은 균질성을 이용하여 시료중의 방사능을 측정할 수 있는 가능성에 대해 조사하였다. 먼저 IP 검출기를 이용하여 면적선원의 표면균질도 측정에 적용하였다. 상용 기준 면적선원$(^{241}Am)$의 방사능 분포에 대한 영상을 얻어서 표면 균질도를 비 파괴적이고 신속하게 측정하였다. 다음으로 IP 검출기를 극저준위 방사능 측정에 적용하여 방사능 측정가능성에 대해 연구하였다. 이를 위해 IP 검출기의 스크린 균질도, 배경방사선 차폐효과, 선형범위 조사, fading 시간을 조사하였다. 극저준위 방사능 측정을 위해 감자 바나나 무 당근에 포함되어 있는 $^{40}K$ 자연방사능을 선택하여 측정하였다. 기준선원을 사용하여 IP 효율교정을 수행하였다.

측두하악관절의 활액성 연골종증 4예 (The synovial chondromatosis of the temporomandibular joints: review of the 4 cases)

  • 이동현;신정섭;곽주희;김진우;김선종;김명래
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권2호
    • /
    • pp.134-140
    • /
    • 2010
  • Synovial condromatosis of the temporomandibular joint (TMJ) is characterized by the presence of loose bodies (joint mices). It can be confused with temporomandibular disorder clinically, and be with chondrosarcoma histologically. The purpose of this clinical report was to review the clinical, radiological, arthroscopic findings, histological feature and the results of surgical treatment of TMJ synovial chondromatosis. Four patients presented with pain of TMJ and limited mouth opening. The dynamic magnetic resonance imaging (MRI) disclosed a characteristic morphologic changes and displacement of the meniscus with limited translation of the condyle head. Bone scans showed progressive resorptive changes with hot-uptake of the radioisotope. The synovial loose bodies in the joint spaces were removed and sent to pathology for diagnosis as the synovial chondromatosis. The follow-up examination with computed tomography (CT) and MRI revealed no evidence of recurrence and good in function until postoperative 18 months. Diagnostically, the distension of the lateral capsule and fluid findings in the joint on the MRI are very suggestive tool for this synovial chondromatosis, but they are not always detected on the preoperative MRI. Arthroscopic approaches are very useful to inspect the joint spaces and to remove the loose bodies without interruption of the whole synovial membranes.

The development of a learning management system for dental radiology education: A technical report

  • Chang, Hee-Jin;Symkhampha, Khanthaly;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제47권1호
    • /
    • pp.51-55
    • /
    • 2017
  • Purpose: This study was conducted to suggest the development of a learning management system for dental radiology education using the Modular Object-Oriented Dynamic Learning Environment(Moodle). Materials and Methods: Moodle is a well-known and verified open-source software-learning management system (OSS-LMS). The Moodle software was installed on a server computer and customized for dental radiology education. The system was implemented for teaching undergraduate students to diagnose dental caries in panoramic images. Questions were chosen that could assess students' diagnosis ability. Students were given several questions corresponding to each of 100 panoramic images. Results: The installation and customization of Moodle was feasible, cost-effective, and time-saving. By having students answer questions repeatedly, it was possible to train them to examine panoramic images sequentially and thoroughly. Conclusion: Based on its educational efficiency and efficacy, the adaptation of an OSS-LMS in dental school may be highly recommended. The system could be extended to continuing education for dentists. Further studies on the objective evaluation of knowledge acquisition and retention are needed.

메소스케일 유연 외팔보 센서를 이용한 진동유동의 무선 계측 (Wireless Telemetry of an Oscillating Flow using Mesoscale Flexible Cantilever Sensor)

  • 박병규;이준식
    • 대한기계학회논문집B
    • /
    • 제37권5호
    • /
    • pp.495-501
    • /
    • 2013
  • 곤충을 비롯한 많은 생물은 매질의 진동을 감지할 수 있는 다양한 감각기관을 이용하여 외부 교란을 감지하고 서로 통신하며 생명 유지활동을 하고 있다. 가장 가까이 접하는 진동유동의 대표적인 예로는 인체의 호흡을 들 수 있다. 본 연구에서는 마이크로제조 공정을 통해 메소스케일 저항식 감지소자, 특히 외팔보 형상의 유연 감지소자를 이용한 유량측정법을 제안하고, 무선통신을 이용한 유동측정 시스템화 및 휴대화의 가능성을 고찰하였다. 탄성계수가 낮은 기질재료를 사용함으로써 온 습도에 영향을 받지 않는 건강 진단용 호흡센서로서의 가능성 및 확장성을 확인하였다. 또한 유동감지 센서의 측정 데이터를 분석한 결과, 정밀성과 신뢰성은 마이크로 컨트롤러의 분해능, 노이즈 제거기술에도 의존하는 것으로 나타났다. 이 시스템에서 패킷 간의 최소 전송소요 시간은 약 16 ms로 나타났다.

CRT 부품용 탈가스 및 Thermal Desorption 측정장치 개발 (Outgassing and thermal desorption measurement system for parts of CRT)

  • 신용현;홍승수;문성주;서일환;정광화
    • 한국진공학회지
    • /
    • 제6권4호
    • /
    • pp.298-307
    • /
    • 1997
  • CRT부품 탈가스(outgassing)를 온도를 변화 시켜가며 측정할 수 있고 시료의 열탈착 특성을 측정할 수 있는 TDS(Thermal Desorption Spectroscopy) 측정 장치를 설계 제작하였다. 제작된 시스템은 유효 배기속도를 조절할 수 있는 진공 장치와 시료의 온도조절 장치, 탈가스 측정 가치로 구성되어 있다. 제작된 시스템의 최저 도달 진공도는 $1{\times}10^{-7}$Pa 이하였고 가변 콘덕탄스(conductance)를 채택하여 유효 배기 속도를 조절 할 수 있도록 제작되었다. 가변 콘덕탄스 조절에 따른 시료위치에서의 유효 배기 속도 변화를 측정하였다. 텅스텐 히터와 온도조절기를 이용하여 시료의 온도는 600℃까지 ±1℃ 이내 오차로 조절 할 수 있었으며 온도 상승률도 조절할 수 있었다. 측정계기로 사용한 이온 진공계(ion gauge)와 사중극 질량분석기(quadrupole mass spectrometer)의 감도를 측정하여 정량적인 측정을 할 수 있도록 하였다. 제작된 시스템을 이용하여 CRT 공정에서의 부품별 온도별 측정 예와 공정분석에의 적용 예를 보였다.

  • PDF

진공표준의 국제비교 연구 (Intercomparison of vacuum standards of Korea, United Kingdom, and Japan)

  • 홍승수;신용현;임종연;이상균;정광화
    • 한국진공학회지
    • /
    • 제6권4호
    • /
    • pp.308-313
    • /
    • 1997
  • Capacitance Diaphragm Gauge(CDG)를 전달표준기로 사용하여 한국과 영국의 저진 공표준의 국제비교를 수행한 결과 양국 표준기에서 교정한 CDG의 압력비의 차이는 0.05% 이었다. 또한 두 개의 Spinning Rotor Gauge(SRG)를 이용하여 한국과 일본이 고진공표준의 국제비교를 수행한 결과 양국 표준기에서 교정한 SRG의 accommodation coefficient($sigma$)의 차이가 0.4% 이내이었다. CDG와 SRG를 이용한 한국과 영국의 저진공표준기 및 한국과 일 본의 고진공표준기의 국제비교 결과 CDG 및 SRG 자체의 고유오차범위 이내에서 결과가 일치함을 확인할 수 있었다.

  • PDF

고관절 초음파의 정상 소견 및 고관절 주위 질환의 초음파 소견 (Ultrasonographic Findings of Normal Hip Joint and Painful Hip due to Soft Tissue Problem)

  • 남우동;남신우;한계영
    • 대한정형외과 초음파학회지
    • /
    • 제3권1호
    • /
    • pp.38-46
    • /
    • 2010
  • 고관절에 위치한 골, 관절 및 주위 연부 조직의 병변은 고관절의 통증을 유발할 수 있다. 이를 진단하기 위해 기초적인 이학적 검사와 단순 방사선 검사를 시행하고, 경우에 따라 CT, MRI 등을 이용하였다. 그러나 건과 점액낭 등의 연부조직 병변 대해서는 초음파 검사가 비침습적이고 역동적인 검사가 가능하고, 고관절에 대한 수술 후 추시 검사 수단으로도 사용할 수 있다. 그러나 성인의 고관절은 심부에 위치하여 그 검사가 힘들고 비만인 환자에게는 적용하기 힘든 경우도 있다. 이에 고관절 주위의 구조물들의 정상적 초음파 소견과 고관절 질환의 병적 소견을 알아보고 또한 기타 활용 방안에 대해 설명하였다.

  • PDF

환경적 요인과 연관된 진동 파라메터를 진단하기 위한 이동평균 예측 진단 모듈 개발 (Development of Moving Average Prediction Diagnostic Module for Vibration Parameter Influenced by Environmental Factors)

  • 오세도;김영진;이태휘
    • 대한기계학회논문집A
    • /
    • 제37권6호
    • /
    • pp.797-804
    • /
    • 2013
  • 본 논문에서는 환경 요인에 영향을 받아 평균이동이 발생하는 진동 파라메터에 대한 진단 방법을 연구하였다. 양산라인에서는 측정 시점에 따라 변화되는 환경요인에 대응되어 측정된 진동 파라메터의 평균이 변화될 수 있다. 이러한 경우 기존에 널리 사용되는 고정된 관리한계선을 사용하는 진단 기법을 사용할 경우 시간이 흐름에 따라 오분류가 발생한다. 이 한계점을 극복하기 위해 저자들은 회귀분석을 활용해 평균 변화의 주요 원인이 되는 환경요인간의 함수관계를 규명하고, 이를 평균이동의 예측에 활용해 각 진단 시점별로 경계 상한과 하한을 유연하게 변경하는 방법론을 제안한다. 제안된 방법론은 적용 과정에서 필요한 모수의 설정 시 레퍼런스 데이터 평가를 통해 합리적인 모수를 추정하는 것이 가능하고, 환경이 변화되는 각 시점에서 데이터에 대해 유연한 진단을 보장한다. H사의 디젤엔진 생산라인의 엔진 진동 검사 데이터를 활용하여 본 논문의 방법론에 대한 검증을 실시하였으며 만족스러운 결과를 도출하였다.

조영증강 의료 초음파 진단에서 파라미터 영상의 개선 기법 (A Parametric Image Enhancement Technique for Contrast-Enhanced Ultrasonography)

  • 김호준;곽성훈
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제3권6호
    • /
    • pp.231-236
    • /
    • 2014
  • 의료 초음파 영상에서 조영제의 전이시간과 조영효과 변화 곡선 특성에 대한 파라미터는 각종 소화기 질환을 진단하는 중요한 인자가 된다. 이러한 진단인자들에 대한 육안판별의 어려움을 극복하기 위하여 파라미터 영상의 자동 생성 기법을 구현할 수 있는데 이 과정에서 마이크로 버블형태의 노이즈와 호흡에 의한 흔들림 현상은 추출된 영상의 신뢰도를 저하 시킨다. 이에 본 연구에서는 MRF(Markov Random Field) 모델을 기반으로 하는 최적화 기법을 적용하여 파라미터 영상을 개선하는 방법을 고찰하며, 호흡에 의한 영상의 흔들림을 보정하기 위한 영상추적 기법을 제시한다. 세부적으로 초음파 동영상 원시 데이터로부터 호흡주기 추출 기법을 구현하였으며, 추출된 주기를 기반으로 모멘텀 요소와 동적 가중치를 반영하는 ROI(Region of Interest) 추적 알고리즘을 적용하였다. 또한 영상 개선 기법에 적용되는 Gibbs 샘플러의 에너지 함수를 정의하고 실제 간질환 진단 데이터를 대상으로 영상 개선 효과를 실험적으로 평가하였다.