• Title/Summary/Keyword: Dynamic contraction

Search Result 105, Processing Time 0.025 seconds

Clinical Application of Combination of Isotonic in Proprioceptive Neuromuscular Facilitation (고유수용성 신경근 촉진법중 등장성수축 결합의 임상적용)

  • Bae Sung-soo;Hwang-bo Gak;Kim Mi-hyun;Kim Jae-Hun;Choi Jae-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.3
    • /
    • pp.205-216
    • /
    • 2004
  • The purpose of this study is to find application of combination of insotonic(CI) in clinical approach. This is a literature study with books and clinical experience. CI was developed after Margaret Knott that is very useful in clinically. CI has two lever system. It has class II lever system for eccentric contraction and class III lever system for concentric contraction. Therefore it make two different contraction that is not only magnitude of motion and speed increase of motion but also biomechanical advantage. Application of CI has much variety by patient position and treatment position. Especially, it is very effectable on mat activities and training for mid stance period. CI apply in supine position on treatment table, mat or high mat activities, bridging activities, all fourth activities and sit on chair activities. CI apply serially with different techniques. These are rhythmic initiation, dynamic reversal, approximation, rhythmic stabilization and replication.

  • PDF

In vivo visualization of liquid-feeding phenomena of a butterfly (나비 펌프의 구조와 동적 거동의 in vivo 가시화)

  • Lee, Seung-Chul;Kim, Bo-Heum;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.4
    • /
    • pp.69-73
    • /
    • 2011
  • Butterflies have been known to suck viscous liquids through a long, cylindrical proboscis using the large pressure difference formulated by the cyclic expansion and contraction of a muscular pump located inside their head. However, there are few studies on the liquid-feeding phenomena in a live butterfly, because it is hard to observe the internal morphological structures under in vivo condition. In this study, the dynamic motion of the pump system in a butterfly was in vivo visualized using synchrotron X-ray micro-imaging technique to analyze the liquid-feeding mechanism. The period of the liquid-feeding process is about 0.3sec. The expansion stage is about two times larger than the contraction stage in one cycle. The cyclic variation of pump volume generate large negative suction pressure and the pressure difference inside the long proboscis of a butterfly is estimated to be larger than 1atm.

Analytical Study on Compressible Plow through Abrupt Enlargement and Contraction (급축소/확대관을 지나는 압축성 유동의 해석적 연구)

  • 김희동;김태호;서태원
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.1 no.1
    • /
    • pp.55-63
    • /
    • 1997
  • The empirical factor and reaction force based on published data were involved to investigate compressible flows through sudden enlargement and sudden contraction passages. Analytical solutions of engineering interest were obtained from one-dimensional steady compressible gas dynamic equations. The effects of com- pressibility, cross-sectional area ratio, and inlet Mach number on the air flows were discussed with regards to the total pressure loss and flow choking. The present results provide available information necessary to design the compressible pipe flow systems.

  • PDF

Changes of abdominal muscle thickness during stable and unstable surface bridging exercise in young people

  • Kim, Tae Hoon;Hahn, Joohee;Jeong, Ju-Ri;Lee, Changjoo;Kim, You Jin;Choi, Sung Min;Jeon, Da Young;Lee, Jin Hwa;Lim, In-Hyuk;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.4
    • /
    • pp.210-214
    • /
    • 2016
  • Objective: The aim of this study was to measure the muscle architectural parameters of abdominal muscles in healthy individuals by rehabilitative ultrasound imaging (RUSI) and to investigate their changes after bridging exercise in various environments. Design: Cross-sectional study. Methods: The study included 40 healthy participants (19 men, 21 women). Subjects were randomly allocated to a stable surface group (SG, n=20) or an unstable surface group (UG, n=20). The participants assumed three positions in rest, bridging exercise with knee flexion $60^{\circ}$, and bridging exercise with knee flexion $90^{\circ}$ for the measurement of abdominal muscle thickness by RUSI. For the resting position, the participants held the head neutral in a hook-lying position and the dominant side was measured. For contraction, the participants performed the bridging exercise with the knee joint in $60^{\circ}$ and $90^{\circ}$ of flexion for 10 seconds each. Results: For transversus abdominis, external oblique muscle thickness, within the stable surface group and the unstable surface group, no significant contraction difference was observed in both the $60^{\circ}$ and $90^{\circ}$ bridge exercise conditions. Contraction difference of internal oblique muscle was significantly larger at $90^{\circ}$ than at $60^{\circ}$ within the SG (p<0.05). But within the UG, no significant contraction difference was shown. There was no significant contraction difference between the surface group and the unstable SG at $60^{\circ}$ condition and at $90^{\circ}$ condition in all measured muscles. Conclusions: The contraction difference is different for each muscle during bridge exercise with knee flexion $60^{\circ}$ and bridging exercise with knee flexion $90^{\circ}$. Muscle contraction difference is generally large when exercised on an unstable surface than a stable surface, but these are not statistically significant when bridging exercise is performed using dynamic air cushion for unstable surface.

The Effect of Abdominal Muscle Contraction Using Waist Circumference Change Sensors on Trunk Muscle Endurance and Postural Control in Healthcare Workers (허리둘레 변화 감지기를 이용한 복부수축이 보건의료 종사자의 몸통 근지구력과 자세조절에 미치는 효과)

  • Yu, Geun-Soo;Kim, Chang-Beom;Cho, In-Ho
    • PNF and Movement
    • /
    • v.17 no.3
    • /
    • pp.451-461
    • /
    • 2019
  • Purpose: This study identified the effect of abdominal muscle contraction using changes in waist circumference for healthcare workers with back pain due to inadequate posture during working hours. Methods: In this study, we provided educational training focused on posture alignment and utilized waist circumference change sensors to induce the contraction of abdominal muscles as a method to address low back pain in healthcare workers. All 32 participants received the same training and then were assigned to two groups: wearing the keeping core band (CB) and not wearing the keeping core band (NCB). For the CB group, the waist circumference change sensor was applied for 6 weeks during working hours. Wilcoxon's signed-ranks test and paired t-tests were used to compare the differences between the groups. All statistical significance levels were set to α=0.05. Results: Trunk muscle endurance increased significantly in the CB group. There was no significant difference in stability index to evaluate static postural control, but active hip abduction tests, which evaluate dynamic postural control, showed significant decrease in the CB group. Conclusion: These results suggest that the induction of abdominal contraction using the waist circumference change sensor may improve the trunk muscle endurance and the postural control ability of the hip and pelvis of healthcare workers.

Development and evaluation of estimation model of ankle joint moment from optimization of muscle parameters (근육 파라미터 최적화를 통한 발목관절 모멘트 추정 모델 개발 및 평가)

  • Son, J.;Hwang, S.;Lee, J.;Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.310-315
    • /
    • 2010
  • Estimation of muscle forces is important in biomechanics, therefore many researchers have tried to build a muscle model. Recently, optimization techniques for adjusting muscle parameters, i.e. EMG-driven model, have been used to estimate muscle forces and predict joint moments. In this study, an EMG-driven model based on the previous studies has been developed and isometric and isokinetic contraction movements were evaluated to validate the developed model. One healthy male participated in this study. The dynamometer tasks were performed for maximum voluntary isometric contractions (MVIC) for ankle dorsi/plantarflexors, isokinetic contraction at both $30^{\circ}/s$ and $60^{\circ}/s$. EMGs were recorded from the tibialis anterior, gastrocnemius medialis, gastrocnemius lateralis and soleus muscles at the sampling rate of 1000 Hz. The MVIC trial was used to customize the EMG-driven model to the specific subject. Once the subject's own model was developed, the model was used to predict the ankle joint moment for the other two dynamic movements. When no optimization was applied to characterize the muscle parameters, weak correlations were observed between the model prediction and the measured joint moment with large RMS error over 100% (r = 0.468 (123%) and r = 0.060 (159%) in $30^{\circ}/s$ and $60^{\circ}/s$ dynamic movements, respectively). However, once optimization was applied to adjust the muscle parameters, the predicted joint moment was highly similar to the measured joint moment with relatively small RMS error below 40% (r = 0.955 (21%) and r = 0.819 (36%) and in $30^{\circ}/s$ and $60^{\circ}/s$ dynamic movements, respectively). We expect that our EMG-driven model will be employed in our future efforts to estimate muscle forces of the elderly.

Effects of Muscle Activation Pattern and Stability of the Lower Extremity's Joint on Falls in the Elderly Walking -Half a Year Prospective Study- (노인 보행 시 하지 근 활동 양상과 관절의 안정성이 낙상에 미치는 영향 -전향적 연구(Prospective Study)-)

  • Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.2
    • /
    • pp.79-88
    • /
    • 2019
  • Objective: The aim of this study was to determine the peak torques of the knee and ankle joint and local stability of the lower extremity's joints, and muscle activation patterns of the lower extremity's muscles between fallers and non-fallers in the elderly women during walking. Method: Four elderly women (age: $74.5{\pm}5.2yrs.$; height: $152.1{\pm}5.6cm$; mass: $55.3{\pm}5.4kg$; preference walking speed: $1.19{\pm}0.06m/s$) who experienced falls within six months since experiment had been conducted (falls group) and thirty-six subjects ($74.2{\pm}3.09yrs.$; height: $153.6{\pm}4.9cm$; mass: $56.7{\pm}6.4kg$; preference walking speed: $1.24{\pm}0.10m/s$) who had no experience in falls (non-falls group) within this periods participated in this study. They were measured torque peaks of the knee and ankle joint using a Human Norm and while they were walking on a treadmill at their natural pace, kinematic variables and EMG signals were collected with using a 3-D motion capture system and a wireless EMG system, respectively. Lyapunov Exponent (LyE) was determined to observe the dynamic local stability of the lower extremity's joints, and muscles activation and their co-contraction index were also analysed from EMG signals. Hypotheses between falls and non-falls group were tested using paired t-test and Mann-Whitey. Level of significance was set at p<.05. Results: Local dynamic stability in the adduction-abduction movement of the knee joint was significantly lower in falling group than non-falling group (p<.05). Conclusion: In conclusion, muscles which act on the abduction-adduction movement of the knee joint need to be strengthened to prevent from potential falls during walking. However, a small number of samples for fallers make it difficult to generalize the results of this study.

Effects of EMG-Biofeedback based Closed Kinetic Chain Exercise on Quadriceps Muscle Activity and Dynamic Balance in Patellofemoral Pain Syndrome (근전도 생체되먹임 기반 닫힌사슬운동이 무릎넙다리통증증후군의 넙다리네갈래근 근활성도와 동적 균형에 미치는 영향)

  • Kang, Joo-hyun;Kim, Je-ho
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.89-98
    • /
    • 2021
  • Purpose: The purpose of this study was to determine the effects of electromyography (EMG)-biofeedback based closed kinetic chain exercise (CKCE) on quadriceps muscle activity and dynamic balance ability in patellofemoral pain syndrome (PFPS). Methods: Thirty subjects with PFPS were included and they were divided into EMG-biofeedback using CKCE (Group I) and squat exercise using CKCE (Group II), each group consisted of 15 patients. Group I and Group II was performed by the patients for three times a week, for six weeks. sEMG was used to measure quadriceps muscle activity and star excursion balance test (SEBT) was used to measure dynamic balance ability. Results: According to the results of the comparisons between the groups, after intervention, quadriceps muscle activity and dynamic balance ability were significantly higher in Group I than in the Group II. Conclusion: Findings of this study suggest that EMG-biofeedback using CKCE that provides real-time biofeedback information on muscle contraction may have a beneficial effect on selective muscle strength of vastus medialis oblique muscle and dynamic balance ability in PFPS.

Muscles Activation of Trunk and Lower-limb during Integrating Bridge Exercise Using Gym Ball in Healthy Individuals

  • Lee, Sue-Min;Oh, Duck-won;Son, Sung-Min
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.4
    • /
    • pp.187-191
    • /
    • 2022
  • Purpose: The purpose of our study aimed to identify the effect of static and dynamic bridge exercise with gym ball using gym ball on muscle activation of trunk and lower-limb in healthy individuals. Methods: A total of 20 healthy adults participated in this study. The individuals performed general bridge exercise, static and dynamic bridge exercise using gym ball. During the three methods of bridge exercises, electromyography (EMG) data (% maximum voluntary isometric contraction) of the rectus abdominis, erector spinae, biceps femoris, and gastrocnemius were recorded using a wireless surface EMG system. Results: Rectus abdominis activation showed significantly greater during dynamic bridge exercise compared with general bridge exercise and dynamic bridge exercise. Erector spinae, biceps femoris, and gastrocnemius were greater during static and dynamic bridge exercise compared with general bridge exercise. Conclusion: Based on our results, bridge exercise using gym ball, particularly integrating lower-limb movement, could be a useful method to enhance muscle activation of trunk and lower-limb (rectus abdominis, erector spinae, biceps femoris, and gastrocnemius).

A study on Identification of EMG Patterns and Analysis of Dynamic Characteristics of Human Arm Movements (팔 운동 근전신호의 식별과 동특성 해석에 관한 연구)

  • Son, Jae-Hyun;Hong, Sung-Woo;Lee, Kwang-Suk;Nam, Moon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.799-804
    • /
    • 1991
  • This paper is concerned with the artificial control of prosthetic devices using the electromyographic(EMG) activities of biceps and triceps in human subject during isometric contraction adjustments at the elbow. And it was analysised about recognition of EMG signals and dynamic characteristics at arm movements of human. For this study the error signal of autoregressive(AR) model were used to discriminate arm movement patterns of human. Interaction of dynamic characteristics (Position, Velocity, Acceleration) and EMG of biceps and triceps at arm movements of human was measured.

  • PDF