• 제목/요약/키워드: Dynamic Strength

검색결과 1,738건 처리시간 0.028초

진동구조물 슬래브 보호층으로서 라텍스 콘크리트의 수밀특성 분석 (Investigation on Watertight Properties of the Latex Concrete for Protection Layers of the Slab on Vibrating Strucutres)

  • 이선규;이정훈;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.247-252
    • /
    • 2009
  • The LMC method of construction which have application to the road bridge is being considered the least relative importance about the watertight performance, because it focused on the durability of concrete. However, The LMC which is being expanded scope of application to the method of construction has grown importance about the watertight performance on the usability and maintenance side as well as durability. In this study, The latex concrete of two types which are different from mingled-ratio of the latex made a comparison to the compressive strength, watertight performance, dynamic wheel load resistance performance and confirmed what it has resistibility about chemical action through the chemical resistance test. The initial strength and watertight performance showed that were tendency the downward at 14 days. However, The long-term strength after 28 days showed that it has firm performance. In consequence, The initial curing of latex concrete is required to scrupulous care and attention at the site application. As a chemical resistance test result, The specimen that is steeped in sulphuric acid solution of 2% discovered the delamination phenomenon. However, it was confirmed that delamination phenomenon don't have an effect on the compressive strength. Moreover, As a dynamic wheel load resistance test result, The latex concrete was concluded to confirming the durability and running stability, because it had hardly any thickness reduction of latex concrete surface about dynamic wheel load and rarely found crack and delamination.

  • PDF

개질재 첨가에 따른 SMA 혼합물의 소성변형 및 변형강도 특성 연구 (Evaluation of Rutting and Deformation Strength Properties of Polymer Modified SMA Mixtures)

  • 김현환;최영렬;김광우;도영수
    • 한국도로학회논문집
    • /
    • 제11권4호
    • /
    • pp.25-31
    • /
    • 2009
  • SMA 혼합물은 소성변형 저항성이 매우 큰 혼합물로 알려져있다. 하지만 실내 시험에서는 이를 측정할 수 있는 시험법이 아직 미흡한 실정이다. 따라서 본 연구의 목적은 소성변형에 대하여 높은 저항성을 가지는 SMA 혼합물의 변형강도치와 반복주행시험과의 상관성 분석을 통하여 SMA에 변형강도의 적용성을 고찰하는 것이다. 이를 위해 SMA 혼합물의 배합설계를 거쳐 최적 아스팔트함량의 혼합물에 대하여 변형강도 시험과 반복주행 시험을 수행하였다. 연구결과, 변형강도는 SMA 혼합물의 소성변형 특성을 보이기에는 매우 낮은 수준을 나타냈다. 따라서 김테스트에 의한 변형강도는 간접인장강도나 마샬 안정도와 마찬가지로 SMA 혼합물의 소성변형 저항성을 제대로 반영되지 못하는 것을 확인하였다. 또한 반복주행시험의 결과인 동적안정도나 최종침하깊이도 역시 SMA 혼합물의 소성변형 저항성을 평가하는데 문제가 있는 것으로 나타났다.

  • PDF

시간영역패널법을 사용한 3차원 날개의 동적지면효과 연구 (A Study on the Dynamic Ground Effect on Three-Dimensional Wings Using a Time Domain Panel Method)

  • 한철희;조진수
    • 한국항공우주학회지
    • /
    • 제30권4호
    • /
    • pp.10-17
    • /
    • 2002
  • 간접 경계요소법 (비정상패널법)을 사용하여 3차원 날개의 동적 지면효과에 대한 연구를 수행하였다. Green 정리를 사용하여 경계표면에 대한 적분방정식을 얻었다. 일정강도의 용출 및 용흡중첩을 날개표면에 분포시켰고 후류는 일정강도의 용흡중첩으로 나타내었다. 매 시간간격마다 한 행의 후류 패널들이 날개의 후연에서 하류로 대류한다고 가정하였다. 지면효과를 받는 날개의 익단 와류가 날개길이방향으로 이동하였다. 동적 지면효과를 받는 날개가 가지는 공력계수의 진폭 값이 정적 지면효과를 받는 날개의 경우보다 더욱 증가하였다.

Seismic performance and optimal design of framed underground structures with lead-rubber bearings

  • Chen, Zhi-Yi;Zhao, Hu;Lou, Meng-Lin
    • Structural Engineering and Mechanics
    • /
    • 제58권2호
    • /
    • pp.259-276
    • /
    • 2016
  • Lead-rubber bearings (LRBs) have been used worldwide in seismic design of buildings and bridges owing to their stable mechanical properties and good isolation effect. We have investigated the effectiveness of LRBs in framed underground structures on controlling structural seismic responses. Nonlinear dynamic time history analyses were carried out on the well-documented Daikai Station, which collapsed during the 1995 Hyogoken-Nanbu earthquake. Influences of strength ratio (ratio of yield strength of LRBs to yield strength of central column) and shear modulus of rubber on structural seismic responses were studied. As a displacement-based passive energy dissipation device, LRBs reduce dynamic internal forces of framed underground structures and improve their seismic performance. An optimal range of strength ratios was proposed for the case presented. Within this range, LRBs can dissipate maximum input earthquake energy. The maximum shear and moment of the central column can achieve more than 50% reduction, whereas the maximum shear displacement of LRBs is acceptable.

Immediate Effect of Postural Control of the Contra-Lateral Side on Exercise-Induced Fatigue of the Ipsi-Lateral Plantar Flexor Muscle

  • Son, Sung Min
    • The Journal of Korean Physical Therapy
    • /
    • 제30권2호
    • /
    • pp.63-66
    • /
    • 2018
  • Purpose: The purpose of the current study was to examine the effects of exercise-induced fatigue of the plantar flexor muscle in the dominant ankle on the plantar flexor strength and postural control function of the contra-lateral side. Methods: Twenty-one young adults (male: 10, female: 11) volunteered to participate in this study. An exercise-induced fatigue protocol to induce fatigue was performed in the plantar flexor of the dominant ankle. For the fatigue protocol, the participants were instructed to raise their heels as high as possible in the position with one leg stance of the dominant lower limb, and the heel was then downed after holding for 1 second. The muscle strength of the contra-lateral plantar flexor was measured using a digital muscle strength test device, and the static and dynamic postural control were tested by acquiring the center of gravity velocity while performing one leg standing. A paired t-test was used to identify the differences between the pre- and post, and the data were analyzed using SPSS 12.0 software. Results: Comparison of the pre- and post-test data revealed a significant difference in the plantar flexor strength and dynamic postural control after exercise-induced muscle fatigue in the dominant side. On the other hand, there was no significant difference in the static postural control. Conclusion: These findings have practical implications, suggesting that unilateral muscle fatigue affects the ankle muscle strength and postural ability of the contralateral side.

Seismic performance of gravity-load designed concrete frames infilled with low-strength masonry

  • Siddiqui, Umair A.;Sucuoglu, Haluk;Yakut, Ahmet
    • Earthquakes and Structures
    • /
    • 제8권1호
    • /
    • pp.19-35
    • /
    • 2015
  • This study compares the seismic performances of two reinforced concrete frame specimens tested by the pseudo-dynamic procedure. The pair of 3-storey, 3-bay frames specimens are constructed with typical characteristics of older construction which is lacking seismic design. One of the specimens is a bare frame while the other is infilled with low-strength autoclave aerated concrete (AAC) block masonry. The focus of this study is to investigate the influence of low strength masonry infill walls on the seismic response of older RC frames designed for gravity loads. It is found that the presence of weak infill walls considerably reduce deformations and damage in the upper stories while their influence at the critical ground story is not all that positive. Infill walls tend to localize damage at the critical story due to a peculiar frame-infill interaction, and impose larger internal force and deformation demands on the columns and beams bounding the infills. Therefore the general belief in earthquake engineering that infills develop a second line of defence against lateral forces in seismically deficient frames is nullified in case of low-strength infill walls in the presented experimental research.

Seismic response assessment of high-strength concrete frames strengthened with carbon fiber reinforced polymers

  • Rahmdel, Javad Mokari;Vahid-Vahdattalab, Farzin;Shafei, Erfan;Zirakian, Tadeh
    • Structural Engineering and Mechanics
    • /
    • 제77권6호
    • /
    • pp.735-744
    • /
    • 2021
  • In recent years, the use of new materials and technologies with the aim of developing high-performing and cost-effective structures has greatly increased. Application of high-strength concrete (HSC) has been found effective in reducing the dimensions of frame members; nonetheless, such reduction in dimensions of structural elements in the most cases may result in the lack of accountability in the tolerable drift capacity. On this basis, strengthening of frame members using fiber reinforced polymers (FRPs) may be deemed as an appropriate remedy to address this issue, which albeit requires comprehensive and systematic investigations. In this paper, the performance of properly-designed, two-dimensional frames made of high-strength concrete and strengthened with Carbon Fiber Reinforced Polymers (CFRPs) is investigated through detailed numerical simulation. To this end, nonlinear dynamic time history analyses have been performed using the Seismosoft software through application of five scaled earthquake ground motion records. Unstrengthened (bare) and strengthened frames have been analyzed under seismic loading for performance assessment and comparison purposes. The results and findings of this study show that use of CFRP can be quite effective in seismic response improvement of high-strength-concrete structures.

녹차-목재섬유복합보드의 동적탄성률에 미치는 녹차배합비율의 영향 및 휨 진동법에 의한 정적 휨 강도성능 예측 (Effect of Green Tea Content on Dynamic Modulus of Elasticity of Hybrid Boards Composed of Green Tea and Wood Fibers, and Prediction of Static Bending Strength Performances by Flexural Vibration Test)

  • 박한민;이수경;석지훈;최남경;권창배;허황선;변희섭;양재경;김종철
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권6호
    • /
    • pp.538-547
    • /
    • 2011
  • 이 연구에서는 녹차와 목재섬유를 복합한 친환경 복합보드를 건축내장재로 활용하기 위하여, 목재섬유에 대한 녹차의 배합비율을 달리한 녹차-목재섬유 복합보드를 제작하였고, 복합보드의 동적탄성률에 미치는 녹차의 배합비율 및 바인더로 사용한 접착제의 영향을 조사하였다. 녹차-목재섬유복합보드의 동적탄성률은 녹차를 넣지 않은 대조보드(control boards)의 그것보다 적었고, 녹차배합비율이 증가할수록 커지는 경향을 나타내었다. 또한, 보드제조에 사용된 바인더의 종류에 따라 동적탄성률의 차이가 나타났는데, $E_1$급의 요소수지가 $E_0$급의 요소수지보다 1.06~1.54배의 높은 값을 나타내었으며, 녹차의 배합비율이 커질수록 양자의 차이는 커지는 것이 확인되었다. 한편, 녹차-목재섬유복합보드의 동적탄성률과 휨 강도성능과는 비교적 높은 상관관계가 확인되어 일부 편차가 큰 조건을 제외하고 동적탄성률로부터 정적 휨 강도성능의 예측이 가능할 것으로 확인되었다.

스플릿 홉킨슨 압력봉 실험장비를 이용한 암석의 동적 압열인장강도 평가에 관한 연구 (Estimation of Dynamic Brazilian Tensile Strengths of Rocks Using Split Hopkinson Pressure Bar (SHPB) System)

  • 양정훈;안중량;김승곤;송영수;성낙훈;이연규;조상호
    • 터널과지하공간
    • /
    • 제21권2호
    • /
    • pp.109-116
    • /
    • 2011
  • 본 연구에서는 스플릿 홉킨슨 압력봉 실험장비를 적용한 압열인장 실험을 수행하여, 암석의 동적인장강도 및 변형률 속도를 평가하였다. 시료가 파괴되기 전에 시료 내 동적 응력평형상태를 확보하기 위하여 펄스쉐이핑 기법으로 입사파의 증가시간을 제어하였다. 압열인장 실험시료는 Inada 화강암, Kimachi 사암, Tage응회암을 정밀하게 가공하여 제작되었다. 결과로서, Inada 화강암의 동적인장강도는 정적인장강도의 11.9배 이였으며, Kimachi 사암과 Tage 응회암은 각각 8.5배, 9.2배로 평가되었다. 고속카메라를 이용하여 시료 내 축 하중 방향으로 발생하는 인장균열의 발생양상을 관찰하였다.

택코트 첨가 가열아스팔트 혼합물의 고주파 동적저항 특성 및 접착성능 평가에 대한 연구 (A Study for Evaluation of Hot Mixed Asphalt Mixtures with Tack-Coat Regarding High-Frequency Dynamic Resistance Performance and Bonding Property)

  • 김도완;문성호
    • 한국도로학회논문집
    • /
    • 제17권3호
    • /
    • pp.35-47
    • /
    • 2015
  • PURPOSES : A tack coat has been utilized to increase the bond performance between the surface layer and base course (intermediate course) at various road pavement sites. This is similarly true in other nations. Based on this connection, the objective of the present study is to evaluate the properties of hot mix asphalt (HMA) mixtures with an RSC-4 or BD-Coat and determine the application rate of the tack coat. METHODS : The HMA specimens were manufactured using superpave gyratory compaction. The HMA mixtures were composed of a 5-cm thick surface layer and a 10-cm thick base course. An impact hammer resonance test (IHRT) and a static load shear test were conducted to evaluate the performance of the HMA mixtures with a tack coat. From these tests, the dynamic moduli related to the high-frequency resistance and interlayer shear strength (ISS) of HMA could be obtained. RESULTS : The results of the dynamic moduli of HMA are discussed based on the resonance frequency (RF). To check the accuracy of the IHRT, we conducted a coherence analysis. A direct shear test using the application of a static load test was carried out to evaluate the interlayer shear strength (ISS) of HMA. CONCLUSIONS : The maximum ISS was demonstrated at an RSC-4 application rate of 462 gsm, and the maximum dynamic modulus was demonstrated at an RSC-4 application rate of 306 gsm. By averaging the results of the ISS, the maximum ISS values were obtained when a BD-Coat application rate of 602 gsm was applied.