• 제목/요약/키워드: Dynamic Response Signal

검색결과 223건 처리시간 0.026초

모드분해기법을 이용한 동적 변형률신호로부터 변위응답추정 (Estimation of Displacement Responses from the Measured Dynamic Strain Signals Using Mode Decomposition Technique)

  • 김성완;장성진;김남식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.109-117
    • /
    • 2008
  • In this study, a method predicting the displacement responseof structures from the measured dynamic strain signal is proposed by using a mode decomposition technique. Dynamic loadings including wind and seismic loadings could be exerted to the bridge. In order to examine the bridge stability against these dynamic loadings, the prediction of displacement response is very important to evaluate bridge stability. Because it may be not easy for the displacement response to be acquired directly on site, an indirect method to predict the displacement response is needed. Thus, as an alternative for predicting the displacement response indirectly, the conversion of the measured strain signal into the displacement response is suggested, while the measured strain signal can be obtained using fiber optic Bragg-grating (FBG) sensors. To overcome such a problem, a mode decomposition technique was used in this study. The measured strain signal is decomposed into each modal component by using the empirical mode decomposition(EMD) as one of mode decomposition techniques. Then, the decomposed strain signals on each modal component are transformed into the modal displacement components. And the corresponding mode shapes can be also estimated by using the proper orthogonal decomposition(POD) from the measured strain signal. Thus, total displacement response could be predicted from combining the modal displacement components.

  • PDF

전압 이중 검출법에 의한 독립형 엔진-발전기 시스템 응답특성 개선 (Dynamic Response Improvement of Stand Alone Engine-Generator System using Double Voltage Detection Method)

  • 이동희;안진우
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1195-1199
    • /
    • 2008
  • In this paper, peak detector of generator's output voltage and variable gain controller are introduced for a fast dynamic response. The conventional r,m.s, signal detected has inherent time delay, and the dynamic response of generator using conventional PID controller has some problem in sudden load change. In this paper, the peak detector and signal selector with variable gain controller is used to overcome this problem. The main controller can check the voltage state from the peak detector. When a sudden load change, the over-voltage and under-voltage signal from peak detector change the controller's gain and exciter's current reference. The proposed scheme can improve the dynamic response, which is verified from experimental test of 200kW diesel engine-generator.

공압밸브의 동적응답 특성측정 자동화 시스템 개발 (Development of automatic measurement system for dynamic respose time of pneumatic solenoid valve)

  • 강보식;김형의
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.974-978
    • /
    • 1991
  • Electro-pneumatic valve is an electro-mechanical device which converts electric signal into pneumatic flow mu or pressure. A measurement of dynamic response time is very important to evaluate valve performance. Dynamic response time of electro-pneumatic valve has a variation accordance with valve types, operating way and test standard. In this study, automatic measurement system of dynamic response time is composed based on test condition of dynamic response time test standard(CETOP, JIS). Also, in this study test pressure variation characteristics accordance with variation of solenoid excitation power, and we developed dynamic response measurement system enable to compare of and analyze these two characteristics.

  • PDF

모드분해기법을 이용한 동적 변형률신호로부터 변위응답추정 (Estimation of Displacement Response from the Measured Dynamic Strain Signals Using Mode Decomposition Technique)

  • 장성진;김남식
    • 대한토목학회논문집
    • /
    • 제28권4A호
    • /
    • pp.507-515
    • /
    • 2008
  • 본 연구에서는 모드분해기법을 이용한 변형률신호로부터 변위응답추정 방법을 개발하였다. 일반적으로 교량의 안정성평가는 완공 후에 초점이 맞추어져 있다. 하지만 가설 중에도 풍하중과 지진하중과 같은 동적하중에 노출되어 있으며, 이런 동적하중에 대한 안정성을 검토하기 위해 교량의 안정성 평가에 있어 중요한 인자인 변위를 추정하는 것이 중요하다. 그러나 건설현장에서의 적절한 변위측정 방법의 부재로 인하여 대형구조물의 전체적인 변위를 측정할 수 없는 것이 현실이다. 본 연구에서는 간접적으로 변위를 추정하는 방법인 변형률로 변위를 추정하는 방법을 제시하였으며, 광섬유 브래그 격자 센서(fiber optic Bragg-grating sensor)를 사용하여 변형률을 계측하였다. 기존에도 FBG센서를 이용한 변위추정 방법이 있었으며 기존의 방법으로는 정적하중에 대한 변위추정은 가능하였으나 고차 모드의 변형률신호와 노이즈의 영향 때문에 동적하중에 대한 변위추정은 많은 오차가 발생하여 정확한 변위추정이 어려웠다. 이런 오차를 줄이는 방법으로 모드분해기법을 사용하였다. 모드분해기법은 변형률신호로부터 proper orthogonal decomposition(POD)을 이용하여 추정한 모드형상과 empirical mode decomposition(EMD)을 이용하여 모드 분해한 변형률신호로 모드별 변위응답을 추정하고, 구조물의 주요 모드에 대한 변위응답을 합하여 전체변위응답을 추정하는 방법이다. 제안한 모드분해기법을 검증하기 위해 실내모형실험을 수행하였다.

멀티레이트 신호처리와 동적 래이턴스 보정에 의한 단일 응답 유발전위 뇌파 추출 (Estimation of single-trial event-related potentials using multirate signal processing latency compensation)

  • 이용희;이두수
    • 전자공학회논문지S
    • /
    • 제34S권12호
    • /
    • pp.60-69
    • /
    • 1997
  • We present an average method based on the multirate signal processing and dynamic allocation average for the purpose of monitoring event-related potentials(ERP) and continuously and dynamically. In the proposed method, first, latency shifts are detected through the cross correlation between a current response and the reference response. Then, the multirate signal processing which is composed of up-sampler, lowpass filter, and down sampler is performed to compensate the latency shifts of the reference response, therefore we obtain the reference response with a peak latencies compenated by those of a current response. Finally, the single response is obtained by averaging the compensated reference response and a current response. In the simulation, the results of quantitative evaluation by simulation and the results using linical data are presented. From the result, the proposed method reflects dynamic time-varying ERP more exactly than previous methods and is also effective in consecutive monitoring of ERP.

  • PDF

Fundamental Small-signal Modeling of Li-ion Batteries and a Parameter Evaluation Using Levy's Method

  • Zhang, Xiaoqiang;Zhang, Mao;Zhang, Weiping
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.501-513
    • /
    • 2017
  • The fundamental small-signal modeling of lithium-ion (Li-ion) batteries and a parameter evaluation approach are investigated in this study to describe the dynamic behaviors of small signals accurately. The main contributions of the study are as follows. 1) The operational principle of the small signals of Li-ion batteries is revealed to prove that the sinusoidal voltage response of a Li-ion battery is a result of a sinusoidal current stimulation of an AC small signals. 2) Three small-signal measurement conditions, namely stability, causality, and linearity, are proved mathematically proven to ensure the validity of the frequency response of the experimental data. 3) Based on the internal structure and electrochemical operational mechanism of the battery, an AC small-signal model is established to depict its dynamic behaviors. 4) A classical least-squares curve fitting for experimental data, referred as Levy's method, are introduced and developed to identify small-signal model parameters. Experimental and simulation results show that the measured frequency response data fit well within reading accuracy of the simulated results; moreover, the small-signal parameters identified by Levy's method are remarkably close to the measured parameters. Although the fundamental and parameter evaluation approaches are discussed for Li-ion batteries, they are expected to be applicable for other batteries.

상관관계법에 의한 제어계통의 동 특성연구 ( 1 )-의 불규칙 2진신호에 의한 푸로쎄스의 동특성 상관측정 (Correlation Measurement of Process Dynamic Characteristics by Pseudo-Random Binary Singnals)

  • 한만춘;최경삼;박장춘
    • 전기의세계
    • /
    • 제19권6호
    • /
    • pp.1-7
    • /
    • 1970
  • In this paper, to determine process dynamic characteristics, the correlation method for measuring the impulse response of process using a pseudo-random binary signal as the test signal instead of white noise was studied. The error caused by using the signal of Mesquence signal generator which was built up by the authors was analysed. Experments were performed on the 1st and 2nd order lag systems and the results were in good coincidence with theoretical values. It is expected that applying these results, it may be possible to develop a continuous measuring method adaptable to modern control systems.

  • PDF

서보밸브의 주파수 응답 신호에 관한 연구 (A Study on the Frequency Response Signals of a Servo Valve)

  • 윤홍식;김성동
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권1호
    • /
    • pp.17-23
    • /
    • 2021
  • The flow signal or spool position signal is used to determine the dynamic characteristics of directional control valves. Alternatively, the signal of spool position or flow can be replaced with the velocity of a low friction, low inertia actuator. In this study, the frequency response of the servo valve equipped with a spool position transducer is measured with a metering cylinder. The input signal, spool displacement, load pressure, and velocity of the metering cylinder are measured, and the theoretical results from the transfer function analysis are verified. The superposition rule for magnitude ratio and phase angle was found to be always applicable among any signal type, and it was found that the load pressure signal is not appropriate for use as the signal for measuring the frequency response of a servo valve. It was confirmed that the frequency response of a servo valve using metering cylinder was similar to the results from a spool displacement signal. The metering cylinder used for measuring the frequency response of a servo valve should be designed to have sufficiently greater bandwidth frequency than the bandwidth frequency of the servo valve.

Holder exponent analysis for discontinuity detection

  • Sohn, Hoon;Robertson, Amy N.;Farrar, Charles R.
    • Structural Engineering and Mechanics
    • /
    • 제17권3_4호
    • /
    • pp.409-428
    • /
    • 2004
  • In this paper, a Holder exponent, a measure of the degree to which a signal is differentiable, is presented to detect the presence of a discontinuity and when the discontinuity occurs in a dynamic signal. This discontinuity detection has potential applications to structural health monitoring because discontinuities are often introduced into dynamic response data as a result of certain types of damage. Wavelet transforms are incorporated with the Holder exponent to capture the time varying nature of discontinuities, and a classification procedure is developed to quantify when changes in the Holder exponent are significant. The proposed Holder exponent analysis is applied to various experimental signals to reveal underlying damage causing events from the signals. Signals being analyzed include acceleration response of a mechanical system with a rattling internal part, acceleration signals of a three-story building model with a loosing bolt, and strain records of an in-situ bridge during construction. The experimental results presented in this paper demonstrate that the Holder exponent can be an effective tool for identifying certain types of events that introduce discontinuities into the measured dynamic response data.

Dynamic Synchronous Phasor Measurement Algorithm Based on Compressed Sensing

  • Yu, Huanan;Li, Yongxin;Du, Yao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권1호
    • /
    • pp.53-76
    • /
    • 2020
  • The synchronous phasor measurement algorithm is the core content of the phasor measurement unit. This manuscript proposes a dynamic synchronous phasor measurement algorithm based on compressed sensing theory. First, a dynamic signal model based on the Taylor series was established. The dynamic power signal was preprocessed using a least mean square error adaptive filter to eliminate interference from noise and harmonic components. A Chirplet overcomplete dictionary was then designed to realize a sparse representation. A reduction of the signal dimension was next achieved using a Gaussian observation matrix. Finally, the improved orthogonal matching pursuit algorithm was used to realize the sparse decomposition of the signal to be detected, the amplitude and phase of the original power signal were estimated according to the best matching atomic parameters, and the total vector error index was used for an error evaluation. Chroma 61511 was used for the output of various signals, the simulation results of which show that the proposed algorithm cannot only effectively filter out interference signals, it also achieves a better dynamic response performance and stability compared with a traditional DFT algorithm and the improved DFT synchronous phasor measurement algorithm, and the phasor measurement accuracy of the signal is greatly improved. In practical applications, the hardware costs of the system can be further reduced.