• 제목/요약/키워드: Dynamic Pressure Sensor

검색결과 85건 처리시간 0.03초

가간섭성이 낮은 광원을 이용한 광섬유 온도 센서 (A Fiberoptic Temperature Sensor Using Low-Coherence Light Source)

  • 김광수;이홍식;임근희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권12호
    • /
    • pp.691-697
    • /
    • 2000
  • A fiberoptic sensor using a low-coherence SLD as a light source has been studied. The sensor system employing an intrinsic fiber Fabry-Peort interferometer as a sensing tip and a fiber Mach-Zehnder interferometer as a processing one, overcomes the ambiguous reading caused by the highly periodic natrue of conventional high-precision interferometric sensors and provides unambiguous identification of the desired phase among several candidates on the transfer function of an interferometric signal. A tentative application to the temperature sensor shows the potential that the fiberoptic sensor has a side-dynamic range of $0-900^{\circ}C$ as well as reasonable resolution higher than $0.1^{\circ}C$ without ambiguity. Due to the inherent property of the optical fiber itself and the intrinsic fiber Fabry-Perot interferometer, the proposed fiberoptic sensor will give obvious benefits when it is applied to harsh environments to monitor some physical parameters such as temperature, strain, pressure and vibration.

  • PDF

압력센서를 이용한 수중항만공사 로봇의 실린더 길이 측정에 관한 연구 (Study on the measurement of the cylinder lengths of an underwater robot for harbour construction using a pressure sensor)

  • 김치효;김태성;이민기
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2012년도 춘계학술대회
    • /
    • pp.9-10
    • /
    • 2012
  • 수중 방파제 피복작업은 사석의 유실을 방지하기 위해 방파제 겉면에 2-3ton의 돌을 쌓는 작업으로 현재 잠수부에 의해 수작업으로 시공을 하고 있다. 수중에서의 사야문제와 작업의 특성상 잠수부의 육감에 의해 공사가 시행되며 작업 과정에서 산업재해가 빈번히 발생한다. 우리는 이러한 문제점을 해결하기 위해 수중 방파제 피복작업을 위한 수중항만공사 로봇을 개발하였다. 로봇의 유압 실린더 제어를 위한 위치 센서가 필요하며 기존 센서는 구동축에 부착되어 방수가 어렵고 건설현장에서 사용하기에는 내구성이 좋지 못하다. 하지만 압력센서는 유압라인상의 임의의 위치에 부착이 가능하므로 방수박스 내부에 설치할 수 있어 방수가 용이하고 내구성을 높일 수 있다. 따라서 본 논문에서는 압력센서를 이용하여 수중항만공사 로봇의 유압 실린더 길이를 간접적으로 측정하는 실린더 길이 옵서버를 설명한다.

  • PDF

Digital Recording Device를 ol용한 회전중인 블레이드 표면의 압력섭동 측정 (Measurement of Surface Pressure Fluctuations on a Rotating Blade Using a Digital Recording Device)

  • 윤정식;강웅;성형진
    • 대한기계학회논문집B
    • /
    • 제29권10호
    • /
    • pp.1119-1129
    • /
    • 2005
  • A new measurement system of wall pressure fluctuations on a rotating machinery, composed of digital recording device, was developed and evaluated. The small-sized digital recording device was attached on the rotating machinery and then was detached for data reduction. In order to obtain the system transfer function of the digital recording system, a dynamic calibration was performed utilizing the signal from a 1/8 inch B&K microphone as input. The time history of the unsteady pressure was then reconstructed from the output of the sensor by using this transfer function. The reconstructed pressure signals showed good agreement with the reference signal in both temporal and spectral sense. This sensor was then used to measure the wall pressure fluctuations on a rotating blade. An array of microphones were installed on the blade in the circumferential and radial directions. Various statistical moments were obtained from the measurement data set. Comparison of these quantities with the existing studies demonstrated satisfactory agreement. These tests give credence to the relevance and reliability of this device for applications in more complicated turbulent rotating machineries.

압력센서를 이용한 수중항만공사 로봇의 실린더 변위 추정에 관한 연구 (Study on the estimation of the cylinder displacement of an underwater robot for harbor construction using a pressure sensor)

  • 김치효;김태성;이민기
    • 한국항해항만학회지
    • /
    • 제36권10호
    • /
    • pp.865-871
    • /
    • 2012
  • 수중 방파제 피복작업은 사석의 유실을 방지하기 위해 방파제 겉면에 2-3ton의 돌을 쌓는 작업으로 현재 잠수부에 의해 수작업으로 시공을 하고 있다. 수중에서의 사야문제와 작업의 특성상 잠수부의 육감에 의해 공사가 시행되며 작업 과정에서 산업재해가 빈번히 발생한다. 이러한 문제점을 해결하기 위해 본 논문에서는 수중 방파제 피복작업을 위한 수중항만공사 로봇을 개발하였다. 로봇의 유압 실린더 제어를 위해 위치 센서가 필요한데 기존 센서는 구동축에 부착되어 방수가 어렵고 건설현장에서 사용하기에는 내구성이 좋지 못하다. 하지만 압력센서는 유압라인상의 임의의 위치에 부착이 가능하므로 방수박스 내부에 설치할 수 있어 방수가 용이하고 내구성을 높일 수 있다. 따라서 본 논문에서는 압력센서를 이용하여 수중항만공사 로봇의 유압 실린더 변위를 간접적으로 측정하는 관측기를 설명한다.

SLD 광원을 이용한 광섬유 패브리페로 센서 (Fiber Fabry-Perot Sensor using SLD Light Source)

  • 김광수;이병윤;이홍식;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2186-2188
    • /
    • 2000
  • A fiberoptic sensor using an SLD as a light source has been studied. The sensor system employs an intrinsic fiber Fabry-Perot interferometer as a sensing tip and a fiber Mach-Zehnder interferometer as a processing one. A free loading test for temperature application shows that the fiberoptic sensor has a wide-dynamic range as well as high resolution. Due to the inherent property of the optical fiber itself and the intrinsic Fabry-Perot interferometer. the fiberoptic sensor gives obvious benefits when it is applied to harsh environments to monitor some physical parameters such as temperature, strain, pressure and vibration.

  • PDF

SpO2 기반 휴대형 생체 신호 모니터링 시스템 개발 (Development of a Portable SpO2-based Biosignal Monitoring System)

  • 이형봉;박성욱;정태윤
    • 대한임베디드공학회논문지
    • /
    • 제8권5호
    • /
    • pp.273-283
    • /
    • 2013
  • The traditional medical equipments are devices used by medical professionals but not used in public environment. Common people, however, require light-weight medical devices to make healthcare for themselves nowadays. Those medical devices are used to monitor personal health status such as blood pulse, blood pressure, diabetes. Also, some of them are operated in mobile environment called u-healthcare. This paper implements a portable healthcare system composed of $SpO_2$(Saturation of Partial Pressure Oxygen) sensors and a gateway for detecting hypoxemia during people's leasure activity such as climbing or hiking. The $SpO_2$ sensor is designed as watch style to support dynamic exercise and the gateway is designed as necklace style to support the elderly. The result of a performance evaluation shows that the performance of the $SpO_2$ sensor using reflection technology is not lower than that of a clairvoyant styled $SpO_2$ sensor.

초유동 충격파관관 장치 및 측정수단 (Superfluid Shock Tube Facility and Measurement Methods)

  • 양형석
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.202-204
    • /
    • 2002
  • The supurfluid shock tube facility has been developed as a versatile tool for experimental research of low-temperature thermo-fluid dynamic phenomena The shock tube is designed to operate with the He II filled test section which is immersed in superfluid helium. The thermo-dynamic phenomena occurred in this facility are measured using pressure transducers, superconductive temperature sensor and visualization method. In this paper, the design and performance of the superfluid shock tube facility and the superconductive temperature sensor is presented.

  • PDF

집진기의 공기소모량과 백 필터내의 압력전파에 대한 실험적 연구 (Experimental Investigation on Air Consumption and Pressure Wave Propagation inside A Filter Bag of A Dust Collector)

  • 정원락;홍성철
    • 한국산학기술학회논문지
    • /
    • 제9권4호
    • /
    • pp.886-891
    • /
    • 2008
  • 이 연구는 필터 백을 사용하는 집진기에서 펄스밸브에 부착된 솔레노이드 밸브의 통전 시간과 공기소모량 사이의 관계를 실험적으로 규명하였으며 이 때 필터 백에 작용하는 압력파의 전달과정을 고찰하였다. 펄스당 공기소 모량이 집진기 운전비용의 주요 요소이므로 펄스제트의 전파과정을 관찰하고 압력파형과 공기소모량을 측정하였다. 또 주어진 조건하에서 필터 백의 길이의 영향을 고찰하고 효율적인 탈진작용을 할 수 있는 통전시간과 충격량 사이의 관계를 규명하였다 주어진 실험조건 범위에서는 통전시간이 짧을수록 더 큰 충격량을 얻을 수 있으며 동일한 통전 시간에 대하여는 여러 번의 짧은 펄스를 발생시키는 것이 더 효율적인 것으로 나타났다.

Simulator를 이용한 인공무릎관절 접촉면의 압력분포 및 운동성 분석 (Analysis of the Contact Pressure Distribution and Kinetics of Knee Implant Using the Simulator)

  • 이문규;김종민;김동민;최귀원
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권4호
    • /
    • pp.363-367
    • /
    • 2003
  • 인공무릎관절의 수명에 직접적인 영향을 주는 인자는 접촉면에 대한 접촉면적과 압력분포이다 따라서. 이에 대한 실험적인 평가가 필요하였고 knee simulator 혹은 K-scan sensor를 포함한 시스템과 같은 많은 연구가 진행되어 왔다. 그러나 지금까지 보행주기에 따른 연속적인 인공관절 운동에 대한 접촉면의 압력분포를 실시간으로 분석한 연구는 미흡하다 따라서 본 연구의 목적은 보행주기를 모사하는 simulator와 I-scan을 이용하여 연속적인 동작에 따른 접촉면의 압력분포를 분석함에 있다. 본 연구의 목적을 이루기 위해서 생체내 인공관절 환경을 정확히 표현할 수 있는 knee simulator를 제작하였다. 네 방향의 자유도를 갖고 있는 본 simulator는 soft tissue의 기능을 포함하고 있고 PC Program을 통하여 압축하중과 femoral component의 굴곡각을 조절할 수 있다. 본 시스템의 I-scan sensor는 보행주기에 따른 압력분포를 분석할 수 있다. 보행주기에 대한 압력분포는 압축하중곡선에 따라 주요하게 변화함을 알 수 있고 운동성에 영향을 쿠는 압력중심의 위치도 변한다는 것을 알 수 있다. 따라서 본 연구에서 제작한 knee simulator는 보행주기 같은 특정의 운동정보를 이용하여 접촉면의 압력분포 및 운동성 같은 기계적 성능을 평가할 수 있고 형상 설계를 위한 기초 자료를 제공할 수 있다.

Feasibility study on corrosion monitoring of a concrete column with central rebar using BOTDR

  • Sun, Yijie;Shi, Bin;Chen, Shen-En;Zhu, Honghu;Zhang, Dan;Lu, Yi
    • Smart Structures and Systems
    • /
    • 제13권1호
    • /
    • pp.41-53
    • /
    • 2014
  • Optical fiber Brillouin sensor in a coil winding setup is proposed in this paper to measure the expansion deformation of a concrete column with a central rebar subjected to accelerated corrosion. The optical sensor monitored the whole dynamic corrosion process from initial deformation to final cracking. Experimental results show that Brillouin Optical Time Domain Reflectometer (BOTDR) can accurately measure the strain values and identify the crack locations of the simulated reinforced concrete (RC) column. A theoretical model is used to calculate the RC corrosion expansive pressure and crack length. The results indicate that the measured strain and cracking history revealed the development of the steel bar corrosion inside the simulated RC column.