• Title/Summary/Keyword: Dynamic Magnetic Resonance Imaging

Search Result 126, Processing Time 0.036 seconds

Advanced Methods in Dynamic Contrast Enhanced Arterial Phase Imaging of the Liver

  • Kim, Yoon-Chul
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.1
    • /
    • pp.1-16
    • /
    • 2019
  • Dynamic contrast enhanced (DCE) magnetic resonance (MR) imaging plays an important role in non-invasive detection and characterization of primary and metastatic lesions in the liver. Recently, efforts have been made to improve spatial and temporal resolution of DCE liver MRI for arterial phase imaging. Review of recent publications related to arterial phase imaging of the liver indicates that there exist primarily two approaches: breath-hold and free-breathing. For breath-hold imaging, acquiring multiple arterial phase images in a breath-hold is the preferred approach over conventional single-phase imaging. For free-breathing imaging, a combination of three-dimensional (3D) stack-of-stars golden-angle sampling and compressed sensing parallel imaging reconstruction is one of emerging techniques. Self-gating can be used to decrease respiratory motion artifact. This article introduces recent MRI technologies relevant to hepatic arterial phase imaging, including differential subsampling with Cartesian ordering (DISCO), golden-angle radial sparse parallel (GRASP), and X-D GRASP. This article also describes techniques related to dynamic 3D image reconstruction of the liver from golden-angle stack-of-stars data.

Dynamic Contrast-Enhanced MR Imaging of Tietze's Syndrome: a Case Report

  • Kim, Dong Chan;Kim, Sang Yoon;Kim, Bong Man
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.1
    • /
    • pp.55-60
    • /
    • 2020
  • Tietze's syndrome is an inflammatory condition associated with painful swelling of the costochondral, costosternal, and sternoclavicular joints. Tietze's syndrome has been mostly attributed to microtrauma until now; however, this etiology is currently disputed. The diagnosis is based on clinical findings, although a few studies suggest the advantages of imaging. We report a case of Tietze's syndrome with a review of radiological findings, especially magnetic resonance imaging (MRI) with dynamic contrast enhancement.

Current Status of Magnetic Resonance Imaging in Patients with Malignant Uterine Neoplasms: A Review

  • Yu-Ting Huang;Yen-Ling Huang;Koon-Kwan Ng;Gigin Lin
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.18-33
    • /
    • 2019
  • In this study, we summarize the clinical role of magnetic resonance imaging (MRI) in the diagnosis of patients with malignant uterine neoplasms, including leiomyosarcoma, endometrial stromal sarcoma, adenosarcoma, uterine carcinosarcoma, and endometrial cancer, with emphasis on the challenges and disadvantages. MRI plays an essential role in patients with uterine malignancy, for the purpose of tumor detection, primary staging, and treatment planning. MRI has advanced in scope beyond the visualization of the many aspects of anatomical structures, including diffusion-weighted imaging, dynamic contrast enhancement-MRI, and magnetic resonance spectroscopy. Emerging technologies coupled with the use of artificial intelligence in MRI are expected to lead to progressive improvement in case management of malignant uterine neoplasms.

Lymphoepithelial Cyst in Pancreas: a Case Report with Magnetic Resonance Imaging Findings

  • Kim, Hee Jeong;Park, Mi-hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.61-64
    • /
    • 2018
  • Pancreatic lymphoepithelial cysts (LECs) are rare pancreatic cysts with squamous epithelial lining surrounded by dense lymphoid tissue. A preoperative diagnosis of LECs is difficult due to imaging diversity and inadequate documentation because of their rarity. We present a case of surgically confirmed pancreatic LEC with magnetic resonance imaging (MRI) findings as heterogeneous signal intensity on T2-weighted images with multiple septa-like structures, slightly hypo-signal intensity on T1-weighted images, and thin-wall enhancement on dynamic contrast images. LECs are benign lesions without any malignant potential. Therefore, the inclusion of LEC in the differential diagnosis of cystic pancreatic lesions may reduce unnecessary surgical procedures.

Postoperative Chylothorax: the Use of Dynamic Magnetic Resonance Lymphangiography and Thoracic Duct Embolization

  • Lee, Chae Woon;Koo, Hyun Jung;Shin, Ji Hoon;Kim, Mi young;Yang, Dong Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.3
    • /
    • pp.182-186
    • /
    • 2018
  • Dynamic enhanced magnetic resonance lymphangiography can be used to provide anatomic and dynamic information for various lymphatic diseases, including thoracic duct injury, and can also help to guide the thoracic duct embolization procedure. We present a case of postoperative chylothorax demonstrated by dynamic enhanced MR lymphangiography. In this case, the chyle leakage site and location of cisterna chyli were clearly visualized by dynamic enhanced MR lymphangiography, thus allowing for management with thoracic duct embolization.

Hyperpolarization: Sensitivity Boost in Magnetic Resonance Spectroscopy and Imaging

  • Ko, Hyeji;Gong, Gyeonghyeon;Jeong, Gijin;Choi, Ikjang;Seo, Hyeonglim;Lee, Youngbok
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.19 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • Hyperpolarization methods are the most emerging techniques in the field of magnetic resonance (MR) researches since they make a contribution to overcoming sensitivity limitation of MR spectroscopy and imaging, leading to new fields of researches, real-time in vivo metabolic/molecular imaging and MR analysis of chemical/biological reactions in non-equilibrium conditions. Make use of enormous signal enrichments, it becomes feasible to investigate various chemical and biochemical systems with low ${\gamma}$ nuclei in real-time. This review deals with the theoretical principals of common hyperpolarization methods and their experimental features. In addition, more detailed theories, mechanisms, and applications of dissolution dynamic nuclear polarization (D-DNP) are discussed.

Ductal Carcinoma in situ with Multicystic Changes in a Patient with Interstitial Mammoplasty via Paraffin Injection: MRI and Pathological Findings

  • Park, Jiyoon;Woo, Ok Hee;Kim, Chungyeul;Cho, Kyu Ran;Seo, Bo Kyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.2
    • /
    • pp.127-130
    • /
    • 2015
  • Direct injection of foreign material, such as liquid paraffin and silicone, into the breast can induce a foreign body granulomatous reaction and fibrosis, resulting in hard, nodular breast masses and architectural distortion that can mimic neoplasm. Conventional methods, including physical examination, mammography, and ultrasonography are of little use to differentiate between foreign body-induced mastopathy and breast cancer. In patients with foreign body injection such as breast augmentation, dynamic contrast enhanced MR imaging is an excellent imaging modality. Here, the authors report the MR imaging and pathological findings of ductal carcinoma in situ (DCIS) with multicystic changes in a 41-year-old woman with a previous history of interstitial mammoplasty by paraffin injection.

Primary Diffuse Large B-Cell Lymphoma of the Seminal Vesicle: a Case Report

  • Kwag, Kyung Su;Jang, Suk Ki;Yeon, Jae Woo;Kwon, Kye-Won;Son, Jeong Hwan;Kim, Hyuk Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.259-263
    • /
    • 2016
  • Primary diffuse large B-cell lymphoma of the seminal vesicle is an extremely rare disorder, with only two cases reported in the English literature. Here, we present imaging findings of a case of primary diffuse large B-cell lymphoma of the seminal vesicle. On transrectal ultrasonography, the mass presented as a 3.0-cm-sized heterogeneous, hypoechoic lesion in the right seminal vesicle. Computed tomography (CT) revealed a mass with rim-like enhancement in the right seminal vesicle. On magnetic resonance imaging (MRI), the tumor showed iso-signal intensity on T1-weighted images and heterogeneously intermediate-high signal intensity on T2-weighted images. The tumor showed rim-like and progressive enhancement with non-enhancing portion on dynamic scanning. Diffusion restriction was observed in the mass. On fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) imaging, a high standardized uptake value (maxSUV, 23.5) by the tumor was noted exclusively in the right seminal vesicle.

Dynamic Contrast-Enhanced MRI of the Prostate: Can Auto-Generated Wash-in Color Map Be Useful in Detecting Focal Lesion Enhancement?

  • Yoon, Ji Min;Choi, Moon Hyung;Lee, Young Joon;Jung, Seung Eun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.220-227
    • /
    • 2019
  • Purpose: To evaluate the usefulness of wash-in color map in detecting early enhancement of prostate focal lesion compared to whole dynamic contrast-enhanced MRI (DEC MRI) images. Materials and Methods: This study engaged 50 prostate cancer patients who underwent multiparametric MRI and radical prostatectomy as subjects. An expert [R1] and a trainee [R2] independently evaluated early enhancement and recorded the time needed to review 1) a wash-in color map and 2) whole DCE MRI images. Results: The review of whole DCE images by R1 showed fair agreement with color map by R1, whole images by R2, and color map by R2 (weighted kappa values = 0.59, 0.44, and 0.58, respectively). Both readers took a significantly shorter time to review the color maps as compared to whole images (P < 0.001). Conclusion: A trainee could achieve better agreement with an expert when using wash-in color maps than when using whole DCE MRI images. Also, color maps took a significantly shorter evaluation time than whole images.

Quantitative Evaluation of the First Order Creatine-Kinase Reaction Rate Constant in in vivo Shunted Ovine Heart Treated with Oxandrolone Using Magnetization Transfer 31P Magnetic Resonance Spectroscopy (MT-31P-MRS) and 1 H/31P Double-Tuned Surface Coil: a Preliminary Study

  • Thapa, Bijaya;Dahl, Marjanna;Kholmovski, Eugene;Burch, Phillip;Frank, Deborah;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.26-36
    • /
    • 2018
  • Purpose: Children born with single ventricle physiology demonstrate poor growth rate and suffer from malnutrition, which lead to increased morbidity and mortality in this population. We assume that an anabolic steroid, oxandrolone, will promote growth in these infants by improving myocardial energy utilization. The purpose of this paper is to study the efficacy of oxandrolone on myocardial energy consumption in these infants. Materials and Methods: We modeled single ventricle physiology in a lamb by prenatally shunting the aorta to the pulmonary artery and then postnatally, we monitored cardiac energy utilization by quantitatively measuring the first order reaction rate constant, $k_f$ of the creatine-kinase reaction in the heart using magnetization transfer $^{31}P$ magnetic resonance spectroscopy, home built $^1H/^{31}P$ transmit/receive double tuned coil, and transmit/receive switch. We also performed cine MRI to study the structure and dynamic function of the myocardium and the left ventricular chamber. The spectroscopy data were processed using home-developed python software, while cine data were analyzed using Argus software. Results: We quantitatively measured both the first order reaction rate constant and ejection fraction in the control, shunted, and the oxandrolone-treated lambs. Both $k_f$ and ejection fraction were found to be more significantly reduced in the shunted lambs compared to the control lambs, and they are increased in oxandrolone-treated lambs. Conclusion: Some improvement was observed in both the first order reaction rate constant and ejection fraction for the lamb treated with oxandrolone in our preliminary study.