• 제목/요약/키워드: Dynamic Load Factor

검색결과 385건 처리시간 0.03초

고속철도교량의 동적응답에 의한 충격계수 산정 (Impact Factor of High-Speed Railway Bridges from Dynamic Response under KTX Running)

  • 윤혜진;진원종;곽종원;황의승;김병석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1631-1635
    • /
    • 2011
  • To consider dynamic magnification effect at the static design stage, impact load factor is applied to design load. Current impact load factor adopted EUROCODE without verification while Japan suggested impact load factor including velocity of high-speed train throughout theoretical and experimental studies. On the purpose of evaluate current impact load factor, this study investigated the calculation of impact load factor from dynamic response of running train.

  • PDF

고속철도교량의 동적안정성 평가연구 (An Evaluation Study on the Dynamic Stability of High Speed Railway Bridges)

  • 방명석;정광모
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.43-49
    • /
    • 2012
  • In the design of high speed railway bridges is important a impact factor as a tool of assessing the dynamic capacitys of bridges. However, the impact factor(or dynamic amplification factor, DAF) of high speed railway bridges may essentially be changeable because the dynamic response is affected by the long train length(380 m), number of axles and high speed velocity(300 km/h)(Korea Train eXpress: KTX). Therefore, on this study will be examined the dynamic capacity and stability of the typical PSC Box Girder of high speed railway bridge. At first, the static/dynamic analysis is performed considering the axle load line of KTX based upon existing references. Additionally, the KTX moving load is transformed into the dynamic time series load for conducting various parameter studies like axle length, analytical time increment, velocity of KTX. The time history analysis is repeatedly performed to get maximum dynamic responce by varying axle load length, analytical time increment, velocity of KTX. The study shows that dynamic analysis has resonable results with optimal axle load length(0.6 m) and time increment(0.01 sec.) and maximum DAF and dynamic resonance happens at 270 km/h velocity of KTX.

동적하중과 정적하중을 이용한 막구조의 거스트 계수 산출 방법 (The method using dynamic load and static load figures out gust factor of the membrane structure)

  • 왕본강;정재용;유기표;김영문
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.19-24
    • /
    • 2008
  • 본 논문은 풍동실험과 정적하중 실험을 실시하여 강풍 설계시 대공간 구조물의 막구조 동적응답을 확인하여 거스트 계수(gust factor)를 산출해 보고자한다. 이를 위해 섬유재료의 변형률에 따라 하중을 구할 수 있는 막재료 성능실험과 4가지(saddle형, wave형, arch형, point형) 막구조 모형에 따른 횡방향 동적하중과 동적변형응답을 측정할 수 있는 풍동실험, 동적변형응답에 따라 정적하중을 구할 수 있는 정적하중실험을 실시함으로써 거스트 계수(gust factor)를 산출하였다.

  • PDF

직선베벨기어의 동특성해석에 관한 연구 (A Study on Dynamic Characteristic Analysis of Straight Bevel Gear)

  • 류성기;신귀수
    • 한국정밀공학회지
    • /
    • 제12권12호
    • /
    • pp.157-164
    • /
    • 1995
  • Straight belvel gear is used mainly for steering system, final reduction and differential gear in the automobile. The more high load, high velocity driving bevel gear, the more unsafe and unpleasant. In thid study, we get a kinematic equation by modelling straight bevel gear pair with simple elastic system, the dynamic characteristic analysis about this system, we got the dynamic load factor of tooth surface. Comparing the value of dynamic load factor by calculation with the measured value of Terauchi's experimental results is similar. We think it useful to analysis the vibration and the noise of straight bevel gear in operation with the analytic method of dynamic load of straight bevel gear using in this study.

  • PDF

현장재하시험을 통한 강관 매입말뚝의 지지력 안전율 제안 (Analysis of Bearing Capacity and Safety Factor of Dynamic Load Test of Prebored and Precast Steel Pile)

  • 박종전;정상섬;박정식
    • 한국지반공학회논문집
    • /
    • 제34권5호
    • /
    • pp.5-17
    • /
    • 2018
  • 본 연구에서는 풍화암에 근입된 강관 매입말뚝의 안전율 제안을 위하여 정재하시험과 동재하시험을 수행하였다. 현장재하시험은 직경이 0.508, 0.457m 인 시험말뚝을 제작하여 정재하시험(14회)과 동재하시험(EOID 14회, Restrike 14회)을 실시하였다. 이때, 재하시험은 시험말뚝 시공완료 후 (1)초기동재하시험(EOID)을 수행하였으며, (2)시공완료 28일 후 정재하시험을 시행하였으며, (3)정재하시험 완료 후 15일 후에 재항타동재하시험(Restrike)을 실시하였다. 본 연구 결과 Davisson 판정법의 동재하시험을 이용한 지지력 산정 결과 정재하시험 대비 재항타동재하시험은 약 15% 낮게 나타났다. 정재하시험과 동재하시험의 지지력 분석을 통하여 안전율을 비교하였고, 최종적으로 동재하시험 안전율을 기존 2.0에서 1.75로 수정 제안하였다.

Dynamic load concentration caused by a break in a Lamina with viscoelastic matrix

  • Reza, Arash;Sedighi, Hamid M.;Soleimani, Mahdi
    • Steel and Composite Structures
    • /
    • 제18권6호
    • /
    • pp.1465-1478
    • /
    • 2015
  • The effect of cutting off fibers on transient load in a polymeric matrix composite lamina was studied in this paper. The behavior of fibers was considered to be linear elastic and the matrix behavior was considered to be linear viscoelastic. To model the viscoelastic behavior of matrix, a three parameter solid model was employed. To conduct this research, finite difference method was used. The governing equations were obtained using Shear-lag theory and were solved using boundary and initial conditions before and after the development of break. Using finite difference method, the governing integro-differential equations were developed and normal stress in the fibers is obtained. Particular attention is paid the dynamic overshoot resulting when the fibers are suddenly broken. Results show that considering viscoelastic properties of matrix causes a decrease in dynamic load concentration factor and an increase in static load concentration factor. Also with increases the number of broken fibers, trend of increasing load concentration factor decreases gradually. Furthermore, the overshoot of load in fibers adjacent to the break in a polymeric matrix with high transient time is lower than a matrix with lower transient time, but the load concentration factor in the matrix with high transient time is lower.

기존선 궤도의 충격계수 산정에 관한 연구 (Evaluation of Track Impact Factor in the Conventional Line)

  • 엄주환;유영화;엄기영
    • 한국철도학회논문집
    • /
    • 제6권4호
    • /
    • pp.239-245
    • /
    • 2003
  • In this paper, the track impact factor of conventional line was evaluated using the data for wheel load measured in field and the properties of current operating trains. The equation for track impact factor was presented through the statistical analysis of variational ratio in wheel load and compared with other design equations in domestic and foreign countries. A review on the safety of track system in conventional line was made from the relationship between the velocity and the corresponding impact factor. It was found that the impact factor from the proposed equation is a little less than the values from the equations adopted in both AREA and domestic railway, while it is same as the equation for continuous welded rail(CWR) in Japan. Therefore it could be said that the track satisfies a criteria for dynamic load caused by the train and the corresponding level of safety is guaranteed for dynamic load of the train

등방성체용 동적 광탄성 하이브리드 법 개발에 관한 연구 (A Study on the Development of the Dynamic Photoelastic Hybrid Method for Isotropic Material)

  • 신동철;황재석
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2220-2227
    • /
    • 2000
  • In this paper, dynamic photoelastic hybrid method is developed and its validity is certified. The dynamic photoelastic hybrid method can be used on the obtaining of dynamic stress intensity factors and dynamic stress components. The effect of crack length on the dynamic stress intensity factors is less than those on the static stress intensity factors. When structures are under the dynamic mixed mode load, dynamic stress intensity factor of mode I is almost produced. Dynamic loading device manufactured in this research can be used on the research of dynamic behavior when mechanical resonance is produced and when crack is propagated with the constant velocity.

Wind-induced dynamic response and its load estimation for structural frames of single-layer latticed domes with long spans

  • Uematsu, Yasushi;Sone, Takayuki;Yamada, Motohiko;Hongo, Takeshi
    • Wind and Structures
    • /
    • 제5권6호
    • /
    • pp.543-562
    • /
    • 2002
  • The main purpose of this study is to discuss the design wind loads for the structural frames of single-layer latticed domes with long spans. First, wind pressures are measured simultaneously at many points on dome models in a wind tunnel. Then, the dynamic response of several models is analyzed in the time domain, using the pressure data obtained from the wind tunnel experiment. The nodal displacements and the resultant member stresses are computed at each time step. The results indicate that the dome's dynamic response is generally dominated by such vibration modes that contribute to the static response significantly. Furthermore, the dynamic response is found to be almost quasi-static. Then, a series of quasi-static analyses, in which the inertia and damping terms are neglected, is made for a wide range of the dome's geometry. Based on the results, a discussion is made of the design wind load. It is found that a gust effect factor approach can be used for the load estimation. Finally, an empirical formula for the gust effect factor and a simple model of the pressure coefficient distribution are provided.

연속 차량하중에 의한 충격하중의 영향에 관한 연구 (A Study on the Effect of a Series of Trucks on Dynamic load Factor)

  • 황의성
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 봄 학술발표회 논문집
    • /
    • pp.105-110
    • /
    • 1992
  • This study deals with the effect of a series of moving trucks on the Dynamic Load Factor (DLF). The DLF is calculated by investigating the load effect of moving trucks. Therefore, analytical models for frocks, bridge, and road profiles were developed and dynamic structural analysis computer program were developed. Then the DLFs are calculated as a ratio of maximum dynamic load effect and maximum static load effect. Trucks used in this study are 5 axle semi tractor-trailer with the weight of 36 and 54 ton. Simply supported prestressed concrete box girder bridges with 20 and 40m span length are selected. From the results of the DLF for various headway distances, they show a very scattered and relatively high values of the DLF in case of a 20m span length bridge. For a 40m span length bridge, the results show less scattered and small increase of the DLF compared to a 20m span length bridge.

  • PDF