• Title/Summary/Keyword: Dynamic Load Device

Search Result 149, Processing Time 0.026 seconds

Characteristic of Human Dynamic load Acting on the Lightweight Wall (경량벽체에 작용하는 인간의 동적하중 특성)

  • Roh, Yong-Woon;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.188-189
    • /
    • 2013
  • The purpose of this research is to comprehend experimentally the characteristic of human dynamic load and provide the result as basic data to suggest a valid impact-resistance evaluation method. Human motions exerting dynamic load are classified to 3 types. Selecting 3 ranks of motion strength, 3 ranks of load plane stiffness (A:20kN/cm, B:4.7kN/cm, C:2.2kN/cm), and 30 male grownup inspectors in their twenties, load was measured when they applied force on load plane. Result of this research is as follows: (1) Human dynamic load has different nature from object collision in the highest load ratio depending on the load plane stiffness and action time (2) The highest load ratio for each motion was 10.06 for kicking, 4.44 for hitting with shoulder, and 5.58 for fist blow.

  • PDF

A Study on Optimal Electric Load distribution of Generators on board using a Dynamic Programming (동적계획법을 이용한 선내 발전시스템의 최적부하분담 방법에 관한 연구)

  • 유희한
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.106-112
    • /
    • 2000
  • Since the oil crisis, we have been concerned about the energy saving techniques of electric generating systems. As a part of the effort to save energy, automatic electric load sharing device was developed. Usually, ship's electric generating system consists of two or three sets of generator. And, electric generating system is operated as single or parallel operation mode according to the demanded electric power. Therefore, it is important to investigate generators operating mode for the supply of required electric power in the ship in order to decrease the operating cost. So, this paper suggests the method to solve the optimal electric load distribution problem by dynamic programming. And, this thesis indicates that the proposed method is superior to the lagrange multiplier's method in obtaining optimal load distribution solution in the ship's electric generating system.

  • PDF

A Study on the Development of the Dynamic Photoelastic Hybrid Method for Isotropic Material (등방성체용 동적 광탄성 하이브리드 법 개발에 관한 연구)

  • Sin, Dong-Cheol;Hwang, Jae-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2220-2227
    • /
    • 2000
  • In this paper, dynamic photoelastic hybrid method is developed and its validity is certified. The dynamic photoelastic hybrid method can be used on the obtaining of dynamic stress intensity factors and dynamic stress components. The effect of crack length on the dynamic stress intensity factors is less than those on the static stress intensity factors. When structures are under the dynamic mixed mode load, dynamic stress intensity factor of mode I is almost produced. Dynamic loading device manufactured in this research can be used on the research of dynamic behavior when mechanical resonance is produced and when crack is propagated with the constant velocity.

Study on the Fatigue Test and the Accelerated Life Test for Dental Implant using Universal-Joint Test Type (유니버설조인트 시험방식을 이용한 치과용 임플란트의 피로시험 및 가속수명시험에 관한 연구)

  • Do, Gyeong Hun;Lee, Seok Jin;Kim, Jong Mi;Kim, Sung Min
    • Journal of Applied Reliability
    • /
    • v.17 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • Purpose : This paper is a comparative analysis results of the fatigue test for dental implants and accelerated life test by using a static type loading device commonly used in Korea and a dynamic type loading device (universal-joint) recommended by FDA. Methods : Fatigue tests of dental implant is based on ISO 14801 and classified into static load test and dynamic load test. The tests were carried out on three test specimens by four load stress steps under each loading device. For analysis on failure mode such as crack, fracture and permanent deformation of test specimens, we used X-ray three-dimensional computed tomography on test specimens before and after the fatigue tests. The design of the accelerated life test was based on the analysis results of the fatigue life data obtained from the dynamic load test and the statistical analysis software (Minitab ver.15) was used to analyze the appropriate life distribution. Results : As a result of the fatigue tests and the accelerated life tests at same acceleration condition under each test method, the fatigue life under the dynamic type loading device (universal-joint) was shorter than when static type loading device was applied. Conclusion : This paper can be used as a reference when the universal-joint type loading device for implants fatigue test is applied as ISO 14801.

An Experimental Study on the Dynamic Load Characteristics of Surface Mount Device(SMD) (칩마운트 (SMD) 장비의 동하중(動荷重) 발생특성에 관한 실험적 연구)

  • Baek, Jae-Ho;Lee, Hong-Ki;Kim, Kang-Boo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1913-1917
    • /
    • 2000
  • SMD Equipment convey an electronic parts at high speed, then assemble parts into a circuit board, and it develop a long time-duration dynamic force to be caused by moving mass. Vibration problem to be caused by SMD Equipment have an effect on micro-meter level's precision production process, directly, and dynamic stability of building. In the cause of quantitatively access about its vibration problem, input information(or data) of structure dynamic analysis need accuracy information of dynamic load. Determination of Dynamic load is various kinds of method using experimental and theory. In this paper, we got dynamic load using direct measurement method. We expect that an study on the dynamic load characteristic of SMD can be used to Equipment development of low level vibration and basis information of structure dynamic analysis.

  • PDF

Development of Power Supply Device for Load Characteristic Experimentation (부하특성실험을 위한 전원공급장치 개발)

  • Lee, Jong-Pil;Ji, Pyeong-Shik;Lim, Jae-Yoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.2
    • /
    • pp.101-107
    • /
    • 2005
  • The reduced power quality due to some of disturbances on power system has great influence on the efficient and life of load for bad with serious economic loss. The response of load about disturbance needs to analysis quantitatively in detail to improve load characteristics. In this research, a power supply device is developed to supply disturbed power similar to that of power system. The developed device can output a voltage and frequency from 180[V] to 240[V], 55[Hz] to 65[Hz] respectively. The most outstanding feature of this device is a function to be performed steady and dynamic state characteristic experiment on load or appliances. Also, this device is designed to include high accuracy ouput and simple measurement.

A Parametric Study on the Characteristics of the Oil-Lubricated Wave Journal Bearing

  • Suh, Hyun-Seung;Rhim, Yoon-Chul
    • KSTLE International Journal
    • /
    • v.2 no.1
    • /
    • pp.59-64
    • /
    • 2001
  • A new bearing concept, the wave journal bearing, has been developed to improve the static and dynamic performance of a hydrodynamic journal bearing. This concept features a wave in bearing surface. Not only straight but also twisted wave journal bearings are investigated numerically. The performances of straight and twisted bearings are compared to a plain journal bearing over a wide range of eccentricity. The bearing load and stability characteristics are dependent on the geometric parameters such as the number of waves, the amplitude and the starting point of the wave relative to the applied load direction. The bearing performance is analyzed for various configurations and for both cases of smooth and wave member notation. The wave journal bearing, especially for the twisted one, offers better stability than the plain journal bearing under all eccentricity ratios and load orientation.

  • PDF

An Application of Dynamic Loading Test of Precast Module Concrete Decks (프리캐스트 모듈 바닥의 동하중 재하시험)

  • Sung, Ikhyun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.1
    • /
    • pp.73-80
    • /
    • 2017
  • In this study, the panel joint behavior by the vehicle load moving on precast panel is analyzed. The frame was made for loading and the behavior was determined by using each measuring device. The static response of the panel was examined and compared with the theoretical value, and it was found that the characteristics were very reasonable. In addition, acceleration, velocity, and displacement were measured for dynamic impact evaluation, and the characteristics of moving load were analyzed in the test. The vibration frequency of the panel was measured for the dynamic response by the moving load, and the vibration characteristic was considered to be sensitive to the range of the load. As a result, it is considered that the dynamic response of the connection part should be careful in design because the characteristics are different according to the connection method.

Sensor Device Plug & Play for Ubiquitous Computing (유비쿼터스 컴퓨팅을 위한 센서 디바이스 Plug & Play)

  • Park, Jung-Sun;Eun, SeongBae;Yoon, Hyeon-Ju
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.3
    • /
    • pp.151-156
    • /
    • 2012
  • When mounting the sensor device in the way of Plug&Play, sensor device drivers need to be loaded and linked dynamically. Since a sensor node platform is based on small 8 bit MCU, dynamic loading and linking technique used in Windows and Linux can not be applied. In this paper, we present how to link and load dynamically sensor device drivers for sensor device Plug&Play. We implement a prototype and evaluate it to make sure that there is no performance degradation like sensor device driver connection speed and memory usage. Connection speed overhead increases to 0.2ms. Memory usage overhead increases to hundreds byte. It shows that there is no heavy influence in running the actual program.

A Study on Optimal Electric Load Distribution and Generator Operating Mode Using Dynamic Programming (동적계획법을 이용한 발전기의 운전모드 및 최적부하 배분에 관한 연구)

  • H-H Yoo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.313-319
    • /
    • 2002
  • Since the oil crisis in 1970, a great deal of effort has been made to develop automatic electric load sharing systems as a part of the efforts to save energy. A large scale electric generating system composes more than two generators whose characteristics may be different. When such a system is operated individually or in parallel, the lagrange multiplier's method has difficulty in achieving optimal load distribution because generators usually have the limitations of the operating range with inequality constraints. Therefore, a suitable operating mode of generators has to be decided according to the selection of the generators to meet electric power requirements at the minimum cost. In this study, a method which solves the optimal electric load distribution problem using the dynamic programming technique is proposed. This study also shows that the dynamic programming method has an advantage in dealing with the optimal load distribution problem under the limitations of the operating range with inequality constraints including generator operation mode. In this study, generator operating cost curve of second order equation by shop trial test results of diesel generators are used. The results indicate that the proposed method can be applied to the ship's electric generating system.