• Title/Summary/Keyword: Dynamic Fitting

Search Result 176, Processing Time 0.029 seconds

Development of 3D Mapping Algorithm with Non Linear Curve Fitting Method in Dynamic Contrast Enhanced MRI

  • Yoon Seong-Ik;Jahng Geon-Ho;Khang Hyun-Soo;Kim Young-Joo;Choe Bo-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.9 no.2
    • /
    • pp.93-102
    • /
    • 2005
  • Purpose: To develop an advanced non-linear curve fitting (NLCF) algorithm for dynamic susceptibility contrast study of brain. Materials and Methods: The first pass effects give rise to spuriously high estimates of $K^{trans}$ in voxels with large vascular components. An explicit threshold value has been used to reject voxels. Results: By using this non-linear curve fitting algorithm, the blood perfusion and the volume estimation were accurately evaluated in T2*-weighted dynamic contrast enhanced (DCE)-MR images. From the recalculated each parameters, perfusion weighted image were outlined by using modified non-linear curve fitting algorithm. This results were improved estimation of T2*-weighted dynamic series. Conclusion: The present study demonstrated an improvement of an estimation of kinetic parameters from dynamic contrast-enhanced (DCE) T2*-weighted magnetic resonance imaging data, using contrast agents. The advanced kinetic models include the relation of volume transfer constant $K^{trans}\;(min^{-1})$ and the volume of extravascular extracellular space (EES) per unit volume of tissue $\nu_e$.

  • PDF

A Need of Buffering Function for Full-Off Fitting on Movable Bracket using Conventional Line (기존선 가동브래킷 곡선 당김 금구의 완충기능 필요성)

  • Ahn, Young-Hoon;Kim, Chul-Su;Lee, Seung-Il
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.219-222
    • /
    • 2007
  • The Full-Off Fitting of Movable Bracket using conventional line have received a dynamic contact impact between contact wire and pantograph of electric rolling stock, so this impact cause a rapid vibration of foreword and back near the supporting point of movable bracket. The Full-Off Fitting on Movable Bracket in conventional line differs from that in high speed line. Now conventional line have required a speed up for new electric locomotive and electric car. In speed-up track and big impact place, the Full-Off Fitting and the dropper often get demage. We have done a study of buffering function to solve that problem in conventional line. We have find a need adopting buffer fitting. It is decrease a dynamic impact between contact wire and pantograph of electric rolling stock.

  • PDF

Dynamic Characteristic and Fault Analysis of the CANDU Nuclear Fuel Channel (CANDU 핵연료 채널에 대한 동특성 및 결함증상 해석)

  • 박진호;이정한;김봉수;박기용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.345-349
    • /
    • 2003
  • The dynamic behavior of CANDU nuclear fuel channel was analyzed by the use of 3-dimensional finite element method, under the various fault conditions such as a fault in the end fitting support and the removal/migration of the garter spring in the fuel channel, in order to predict the dynamic behavior for a degraded symptoms of CANDU nuclear fuel channel. Moreover, the frequency response analysis for possible fault conditions was also peformed considering the effects of the pressure tube vibration and flow-induced vibration by the coolant flow. From the analysis of the frequency responses, defects in the garter spring have influenced the changes of 2nd and 3rd modes and all the important modes are varied for the failure in the journal bearing in the end fitting body.

  • PDF

Assessment of Non-permeability of Gd-DTPA for Dynamic Susceptibility Contrast in Human Brain: A Preliminary Study Using Non-linear Curve Fitting (뇌영역의 동적 자화율 대조도 영상에서 Gd-DTPA 조영제의 비투과성 조사: 새로운 비선형 곡선조화 알고리즘 개발의 예비연구)

  • Yoon, Seong-Ik;Jahng, Geon-Ho;Khang, Hyun-Soo;Kim, Young-Joo;Choel, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.103-109
    • /
    • 2007
  • To develop an advanced non-linear curve fitting (NLCF) algorithm for performing dynamic susceptibility contrast study of the brain. The first pass effects give rise to spuriously high estimates of $K^{trans}$ for the voxels that represent the large vascular components. An explicit threshold value was used to reject voxels. The blood perfusion and volume estimation were accurately evaluated in the $T2^*$-weighted dynamic contrast enhanced (DCE)-MR images. From each of the recalculated parameters, a perfusion weighted image was outlined by using the modified non-linear curve fitting algorithm. The present study demonstrated an improvement of an estimation of the kinetic parameters from the DCE $T2^*$-weighted magnetic resonance imaging data with using contrast agents.

  • PDF

Application of Modified Ramberg-Osgood Model for Master Curve of Asphalt Concrete (아스팔트 콘크리트 메스터 극선에 대한 수정 Ramberg-Osgood 모델 적용)

  • Kweon, Gi-Chul
    • International Journal of Highway Engineering
    • /
    • v.10 no.4
    • /
    • pp.31-40
    • /
    • 2008
  • The dynamic moduli of asphalt concrete are very important for the analysis and the design of asphalt pavement systems. The dynamic modulus master curve is usually represented by a sigmoidal function. The Ramberg-Osgood model was widely used for fitting of normalized modulus reduction curves with strain of soils in soil dynamic fields. The master curves were obtained by both sigmoidal functions and modified Ramberg-Osgood model for the same dynamic modulus data set, the fitting abilities of both methods were excellent. The coefficients in sigmoidal function are coupled. Therefore, it is not possible to separate the characteristics of the master curve with absolute value and shape. However, the each fitting coefficient in the Ramberg-Osgood model has a unique effect on the master curve, and the coefficients are not coupled with each other.

  • PDF

The Correlation Between Corneal Eccentricity and Radius Curvature by Fitting Status of Soft Contact Lens Wearer (소프트 콘택트렌즈 착용자의 피팅 상태에 따른 각막 이심률과 곡률반경과의 상관관계)

  • Han, Sun-Hee;Kim, Bong-hwan;Park, Jun-Sung;Baek, Su-won;Kwon, Sung Jin;Kim, Eun Kyoung;Yoon, Jung Na;Choi, So Min;Heo, A Jeong;Park, Eun Hye
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.4
    • /
    • pp.662-670
    • /
    • 2016
  • Purpose. Because of a recent increase in use of soft contact lens at younger ages, in the present study, the correlation between corneal eccentricity and radius of curvature and fitting types of contact lens was investigated. Methods. The study evaluated the fitting status of targets through lens centration, push-up test, dynamic lag test and static lag test of lenses usually worn by 49 men and women (98eyes) in their 20s to 30s who put on soft contact lenses. After evaluation, the subjects were classified into 3 categories by fitting status(steep, aligment and flat). The radius of corneal curvature in the naked eyes was measured by using keratometer. Moreover the corneal eccentricity in the nasal side, temporal side, superior side and inferior side was measured by using the device capable of measuring the corneal eccentricity. Results. The radius of corneal curvature and corneal eccentricity of soft lenses worn by subjects were higher in the order of steep fitting and flat fitting, and the higher average corneal curvature radius and corneal eccentricity is intend to be more steep fitting(p=0.051, p=0.052). The corneal eccentricity showed a tendency to nasal fitting type at the higher eccentricity and temporal fitting type at the smaller eccentricity, statistically significant difference was observed(p<0.05). The study showed there were low correlation that nasal and temporal side at steep fitting, superior side at normal fitting and 4side(nasal, temporal, superior, inferior) at flat fitting, therefore when the corneal eccentricity changed the radius of corneal curvature also changed. The corneal eccentricity and the radius of corneal curvature showed statistically significant difference at 4side and each fitting types(p<0.05). Conclusions. The results of this study, the fitting status, of wearer are based on radius of corneal curvature and corneal eccentricity, and if lens fitting would be done considering that, it seems to be useful in a soft contact lens prescription.

Development of Curve Fitted Equations for Dynamic Behavior of Various Buried Pipelines (각종 매설관의 동적거동에 대한 곡선적합식의 개발)

  • Kim, Sung-Ban;Jeong, Jin-Ho;Joeng, Du-Hwoe;Lee, Kwang-Yeol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.4 s.50
    • /
    • pp.25-33
    • /
    • 2006
  • The purpose of this study is to develop the curve fitted equations for practicality and actual calculation during seismic performance evaluation of buried pipelines. Curve fitting for strain curve according to the wavelength of the seismic wave was produced using the non-linear least square method and the equations with the best results was suggested. In addition, a degree and coefficient of polynomial fitting equation needed to use curve fitted equation were identified. Interpreting process during the test of resistance of earthquake of buried pipelines with various end boundary conditions were provided through example questions. The results of this study were used to conduct a dynamic response analysis and a seismic performance evaluation of concrete, steel, and FRP pipes with various end boundary conditions.

Development of Simple Articulated Human Models using Superquadrics for Dynamic Analysis

  • Lee, Hyun-Min;Kim, Jay-Jung;Chae, Je-Wook
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.715-725
    • /
    • 2011
  • Objective: This study is aimed at developing Articulated Human Models(AHM) using superquadrics to improve the geometric accuracy of the body shape. Background: The previous work presents the AHM with geometrical simplification such as ellipsoids to improve analysis efficiency. However, because of the simplicity, their physical properties such as a center of mass and moment of inertia are computed with errors compared to their actual values. Method: This paper introduces a three steps method to present the AHM with superquadrics. First, a 3D whole body scan data are divided into 17 body segments according to body joints. Second, superquadric fitting is employed to minimize the Euclidean distance between body segments and superquadrics. Finally, Fee-Form Deformation is used to improve accuracy over superquadric fitting. Results: Our computational experiment shows that the superquadric models give better accuracy of dynamic analysis than that of ellipsoid ones. Conclusion: We generate the AHM composed of 17 superquadrics and 16 joints using superquadric fitting. Application: The AHM using superquadrics can be used as the base model for dynamics and ergonomics applications with better accuracy because it presents the human motion effectively.

Shock-Fitting in Kinematic Wave Modeling (운동파 이론의 충격파 처리기법)

  • Park, Mun-Hyeong;Choe, Seong-Uk;Heo, Jun-Haeng;Jo, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.2
    • /
    • pp.185-195
    • /
    • 1999
  • The finite difference method and the method of characteristics are frequently used for the numerical analysis of kinematic wave model. Truncation errors cause the peak discharge dissipated in the solution from the finite difference method. The peak discharge is conserved in the solution from the finite difference method. The peak discharge is conserved in the solution from the method of characteristics, however, the shock may deteriorates the numerical solution. In this paper, distinctive features of each scheme are investigated for the numerical analysis of kinematic wave model, and applicability of shock fitting algorithm such as Propagating Shock Fitting and Approximated Shock Fitting methods are studied. Propagating Shock Fitting method appears to treat shock properly, however, it failed to fit the shock appropriately when applied to a sudden inflow change in a long river. Approximate Shock Sitting method, which uses finer elements, is found to be more proper shock-fitting than the Propagating Shock Fitting method. Comparisons are made between two solution from the kinematic wave theory with shock fitting and full dynamic wave theory, and the results are discussed.

  • PDF

The Determination of Take-Off Time in Iteration on Dynamic Susceptibility Contrast Agent MR Perfusion Imaging

  • 김대원;류완석;정성택
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.79-80
    • /
    • 2003
  • In existing method, the threshold has determined the points to be used in extrapolation and only pre-peak points were used to find t0. However, to reduce error in using this fitting method, in this study, finding t0is considered the correlation between fitting result and each profile in using iteration method. And the proposed method is compared with the existing method.

  • PDF