• Title/Summary/Keyword: Dynamic ECG

Search Result 26, Processing Time 0.027 seconds

Minimizing MR Gradient Artefacts on ECG Signals for Cardiac Gating based on an Adaptive Digital Filter (적응 디지털 필터 기반의 MRI Cardiac Gating을 위한 심전도 신호의 MR Gradient 잡음 최소화 방법)

  • Park, Ho-Dong;Jang, Bong-Ryeol;Lee, Kyoung-Joung
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.817-818
    • /
    • 2006
  • In Magnetic Resonance Imaging(MRI), the QRS complex of ECG is used as a trigger signal for MRI scan. But, gradient and RF(radio frequency) artifacts which are caused to static and dynamic field in MRI scanner cause interference in the ECG. Also, the signal shape of theses artifacts can be similar to the QRS-complex, causing possible misinterpretation during patient monitoring and false gating of the MRI. In case of using general FIR or IIR band-pass filters for minimizing the artifacts, artifact-reduction-ratio is not excellent. So, an adaptive real-time digital filter is proposed for reduction of noise by gradient and RF(radio frequency) artifacts. The proposed filter for MRI-Gating is based on the noise-canceller with NLMS(Normalized Least Mean Square) algorithm. The reference signals of the adaptive noise canceller are a combination of the noisy three channel ECG signals. In conclusions, the proposed method showed the acceptable quality of ECG signal with sufficient SNR for gating the MRI and possibility of real time implementation.

  • PDF

Enhancement of ST-segment Features in ECG Signals by Warping Transformation (워핑 변환을 이용한 심전도 신호의 ST 분절 특징 값 강화)

  • Shin, Seung-Won;Kim, Kyeong-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1143-1149
    • /
    • 2010
  • In this study, we propose a novel method to detect and enhance the feature of ST-segment which offers the crucial information for the diagnosis of myocardial infarction and ischemia. With this aim, PQRST features of Electrocardiogram initially are detected and subsequently ST-segment are estimated. And Dynamic Time Warping(DTW) transformation is applied recursively to minimize the difference in time between ST-segments and calculate the minimum cumulative distance that decides the degree of similarity among ST-segments. As of the results, the inherent characteristic of ST-segment can be emphasized in terms of time parameter and thus the diagnostic features of a ST-segment can be revealed further.

Design of an Adaptive Filter with a Dynamic Structure for ECG Signal Processing

  • Lee Ju-Won;Lee Gun-Ki
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.1
    • /
    • pp.137-142
    • /
    • 2005
  • Biomedical signals such as ECG, EMG, and EEG are extremely important in the diagnosis of patients. It is difficult to filter noise from these signals, and errors resulting from filtering can distort a biomedical signal. Existing systems have shown poor performance when complicated noise appears. Adaptive filtering is selected to contend with these defects. Existing adaptive filters can adjust the filter coefficient with the given filter order, but they can produce an unsuitable order in different environments. In order to solve this problem, an optimal adaptive filter with a dynamic structure was designed. Positive experimental results were obtained.

QP-DTW: Upgrading Dynamic Time Warping to Handle Quasi Periodic Time Series Alignment

  • Boulnemour, Imen;Boucheham, Bachir
    • Journal of Information Processing Systems
    • /
    • v.14 no.4
    • /
    • pp.851-876
    • /
    • 2018
  • Dynamic time warping (DTW) is the main algorithms for time series alignment. However, it is unsuitable for quasi-periodic time series. In the current situation, except the recently published the shape exchange algorithm (SEA) method and its derivatives, no other technique is able to handle alignment of this type of very complex time series. In this work, we propose a novel algorithm that combines the advantages of the SEA and the DTW methods. Our main contribution consists in the elevation of the DTW power of alignment from the lowest level (Class A, non-periodic time series) to the highest level (Class C, multiple-periods time series containing different number of periods each), according to the recent classification of time series alignment methods proposed by Boucheham (Int J Mach Learn Cybern, vol. 4, no. 5, pp. 537-550, 2013). The new method (quasi-periodic dynamic time warping [QP-DTW]) was compared to both SEA and DTW methods on electrocardiogram (ECG) time series, selected from the Massachusetts Institute of Technology - Beth Israel Hospital (MIT-BIH) public database and from the PTB Diagnostic ECG Database. Results show that the proposed algorithm is more effective than DTW and SEA in terms of alignment accuracy on both qualitative and quantitative levels. Therefore, QP-DTW would potentially be more suitable for many applications related to time series (e.g., data mining, pattern recognition, search/retrieval, motif discovery, classification, etc.).

Communication-Power Overhead Reduction Method Using Template-Based Linear Approximation in Lightweight ECG Measurement Embedded Device (경량화된 심전도 측정 임베디드 장비에서 템플릿 기반 직선근사화를 이용한 통신오버헤드 감소 기법)

  • Lee, Seungmin;Park, Kil-Houm;Park, Daejin
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.15 no.5
    • /
    • pp.205-214
    • /
    • 2020
  • With the recent development of hardware and software technology, interest in the development of wearable devices is increasing. In particular, wearable devices require algorithms suitable for low-power and low-capacity embedded devices. Among them, there is an increasing demand for a signal compression algorithm that reduces communication overhead, in order to increase the efficiency of storage and transmission of electrocardiogram (ECG) signals requiring long-time measurement. Because normal beats occupy most of the signal with similar shapes, a high rate of signal compression is possible if normal beats are represented by a template. In this paper, we propose an algorithm for determining the normal beat template using the template cluster and Pearson similarity. Also, the template is expressed effectively as a few vertices through linear approximation algorithm. In experiment of Datum 234 of MIT-BIH arrhythmia database (MIT-BIH ADB) provided by Physionet, a compression ratio was 33.44:1, and an average distribution of root mean square error (RMSE) was 1.55%.

A Real Time Heartbeat Rate Estimation Algorithm Using PPG Signals (광용적맥파를 이용한 실시간 맥박 검출 알고리듬)

  • Kim, Chisung;Han, Dong Seog
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.82-87
    • /
    • 2016
  • The photoplethysmogram (PPG) signal is one of the mainly considered bio signals along with the electrocardiogram (ECG) signal. PPG signals can be used to estimate the speed of flow of blood in vein, saturation of peripheral oxygen and etc. The heartbeat rate is a common feature in order to evaluate those checkup lists. To estimate the correct heartbeat rate, dynamic noises must be removed in the PPG signal. Conventionally, the acceleration signal is used to remove dynamic noises. This method, however, increases the computational complexity. In this paper, we proposes a solution that uses only PPG signals to calculate the heartbeat rate, and which can be used as a basement in real-time healthcare solution.

Design of the Adaptive Filter with Dynamic Structure for the Biomedical Signal Processing (생체신호처리를 위한 동적 구조 적응필터 설계)

  • 이주원;김광열;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.5
    • /
    • pp.848-852
    • /
    • 2001
  • The biomedical signals such as ECG, EMG, EEG, and etc are very Important information to diagnose patients The signal is hard to filter the noise because that is mixed with a lot of noise and biomedical signal has the properties of nonlinear and time-variance. So, we will filter under the measure environment for system or patient. But the general adaptive fillet has brought on the distortion of signal because the adaptive filter adjust the filter coefficient with the fixed order of filter, that filter has the unsuitable order in each other environment. So we propose the dynamic structure adaptive filter that is used for improving that disadvantage. In experiment, we obtain the optimal order of adaptive filter and have food results.

  • PDF

Adaptable Noise Reduction of ECG Signals in Dynamic Environment For ECG Feature Extraction (동적인 환경에서의 심전도 특징 추출을 위한 잡음 제거 기술)

  • Kim, Hyun-Dong;Min, Chul-Hong;Kim, Tae-Seon
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.465-468
    • /
    • 2005
  • 심전도 신호의 잡음 신호는 일정한 주파수대역에 존재하지 않고 측정자의 신체 및 환경조건에 따라서 잡음의 종류와 정도가 다르다. 따라서 기존의 고정 주파수 특성을 갖고 있는 필터로는 효율적인 잡음 제거가 불가능하다. 그래서 본 논문에서는 상황인식을 통해 잡음의 형태를 파악하여 적응적으로 필터를 재구성하는 적응적 잡음제거기술을 제안한다.

  • PDF

A Study on the Design of Functional Clothing for Vital sign Monitoring -Based on ECG Sensing Clothing- (생체신호 측정을 위한 기능성 의류의 디자인 연구 -심전도 센싱 의류를 중심으로-)

  • Cho, Ha-Kyung;Song, Ha-Young;Cho, Hyeon-Seong;Goo, Su-Min;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.13 no.3
    • /
    • pp.467-474
    • /
    • 2010
  • Recently, Study of functional clothing for Vital sensing is focused on reducing artifact by human motions, in order to enhance the electrocardiogram(ECG) sensing accuracy. In this study, considering the factors for each element found from the analysis, a 3-lead electrode inside textile embroidered with silver yarn was developed, and draft designs off our types of vital-signal sensing garments, which are 'chest-belt typed' garment, 'cross-typed' garment 'x-typed' garment and 'curved x-typed' garment, were prepared. The draft designs were implemented on a sleeveless male shirt made of an elastic material so that the garment and the electrodes can remain closely attached along the contour of the human body, and the acquired data was sent to the main computer over a wireless network. In order to evaluate the effects caused by body movements and the ECG-sensing capability for each type in static and dynamic states, displacements were measured from one and two dimensional perspectives. ECG measurement evaluation was also performed for Signal-to-noise ratio(SNR) analysis. Applying the experimental results, the draft garment designs were modified and complemented to produce two types of modular approaches 'continuous-attached' and 'insertion-detached' for the ECG-sensing smart clothing.

  • PDF

Policy Adjuster-driven Grid Workflow Management for Collaborative Heart Disease Identification System

  • Deng, Shengzhong;Youn, Chan-Hyun;Liu, Qi;Kim, Hoe-Young;Yu, Taoran;Kim, Young-Hun
    • Journal of Information Processing Systems
    • /
    • v.4 no.3
    • /
    • pp.103-112
    • /
    • 2008
  • This paper proposes a policy adjuster-driven Grid workflow management system for collaborative healthcare platform, which supports collaborative heart disease diagnosis applications. To select policies according to service level agreement of users and dynamic resource status, we devised a policy adjuster to handle workflow management polices and resource management policies using policy decision scheme. We implemented this new architecture with workflow management functions based on policy quorum based resource management system for providing poincare geometrycharacterized ECG analysis and virtual heart simulation service. To evaluate our proposed system, we executed a heart disease identification application in our system and compared the performance to that of the general workflow system and PQRM system under different types of SLA.