구조물의 내진성능 보강을 위한 보-기둥 접합형 감쇠장치 (Beam-Column Junction Type Damper of Seismic Performance Enhancement for Structures)

  • 노정태;우성식;이상현;정란
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.855-863
    • /
    • 2009
  • In this study, a beam-column junction type damper is proposed which saves the inner and outer space for the installation of damping devices and allows easy adjustment of control performance The result of the numerical analysis indicated that the displacement response and base shear of a single degree of freedom system by seismic load, El Centro 1940 was reduced with yield moment of the joint hinge and the specific yield moment ratio $\delta$ of the joint hinge existed for the optimal seismic performance. In addition, the dynamic nonlinear characteristics, effects of yielding and dependence of natural period of bi-linear system with the junction type damper is identified. The analysis of multi-degree of freedom system showed that responses of the controlled structures was reduced significantly as the number of a story increases and yield moment ratio decreases when the system is excited by seismic load and sine wave. On top of that, it was also observed that energy dissipation at the joint connected with the dampers was remarkable during excitation.

  • PDF

Ni계 초내열합금 NIMONIC 80A의 고온변형거동 (High Temperature Deformation Behavior of a NIMONIC 80A Ni-based Superalloy)

  • 하민철;황시우;김종수;김철유;박경태
    • 소성∙가공
    • /
    • 제22권5호
    • /
    • pp.258-263
    • /
    • 2013
  • The deformation behavior of NIMONIC 80A was studied in the high temperature range of $900{\sim}1200^{\circ}C$ and for strain rates varying between 0.02 and $20s^{-1}$ via the hot compression test. Processing maps for hot working were constructed on the basis of the power dissipation efficiency using a dynamic material model. The results showed that the strength during hot compression increased with increasing strain rate and decreasing temperature. At low strains, the processing map of NIMONIC 80A did not reveal any instability domain regardless of the strain rate and temperature. However, at high strains, the processing map exhibited an instability domain at a low strain rate of $0.2s^{-1}$ and within a temperature range of $900{\sim}960^{\circ}C$. In the instability domain, the deformed microstructure exhibited shear bands and carbide precipitation while, in the safe domain, full recrystallization occurred.

A Low-power High-resolution Band-pass Sigma-delta ADC for Accelerometer Applications

  • Cao, Tianlin;Han, Yan;Zhang, Shifeng;Cheung, Ray C.C.;Chen, Yaya
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권3호
    • /
    • pp.438-445
    • /
    • 2017
  • This paper presents a low-power high-resolution band-pass ${\Sigma}{\Delta}$ ADC for accelerometer applications. The proposed band-pass ${\Sigma}{\Delta}$ ADC consists of a high-performance 6-th order feed-forward ${\Sigma}{\Delta}$ modulator with 1-bit quantization and a low-power, area-efficient digital filter. The ADC is fabricated in 180 nm 1P6M mixed-signal CMOS process with a die area of $5mm^2$. This high-resolution ADC got 90 dB peak signal to noise plus distortion ratio (SNDR) and 96 dB dynamic range (DR) over 4 kHz bandwidth, while the intermediate frequency (IF) is shifting from 100 KHz to 200 KHz. The power dissipation of the chip is 5.6 mW under 1.8 V (digital)/3.3 V (analog) power supply.

Extracting parameters of TMD and primary structure from the combined system responses

  • Wang, Jer-Fu;Lin, Chi-Chang
    • Smart Structures and Systems
    • /
    • 제16권5호
    • /
    • pp.937-960
    • /
    • 2015
  • Tuned mass dampers (TMDs) have been a prevalent vibration control device for suppressing excessive vibration because of environmental loadings in contemporary tall buildings since the mid-1970s. A TMD must be tuned to the natural frequency of the primary structure to be effective. In practice, a TMD may be assembled in situ, simultaneously with the building construction. In such a situation, the respective dynamic properties of the TMD device and building cannot be identified to determine the tuning status of the TMD. For this purpose, a methodology was developed to obtain the parameters of the TMD and primary building on the basis of the eigenparameters of any two complex modes of the combined building-TMD system. The theory was derived in state-space to characterize the nonclassical damping feature of the system, and combined with a system identification technique to obtain the system eigenparameters using the acceleration measurements. The proposed procedure was first demonstrated using a numerical verification and then applied to real, experimental data of a large-scale building-TMD system. The results showed that the procedure is capable of identifying the respective parameters of the TMD and primary structure and is applicable in real implementations by using only the acceleration response measurements of the TMD and its located floor.

1/3축소 3층 삼환까뮤 P.C 모델의 진동대 실험 (Shaking Table Test of 1/3-Scale 3-Story Sam-Hwan Camus Precast Concrete Model)

  • 이한선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.140-154
    • /
    • 1992
  • The objective of the research stated here was aimed at providing the information needed to establish the Korean Seismic Design Code Recommendations and Guides for precast concrete (P.C) large panel apartment buildings. This was accomplished by investigation and analysis of the response of P.C large panel structures subjected to shaking table excitation simulating earthquake ground motion. one of the test specimens used was 1/3-scaled 3-story box P.C model provided by Sam-Hwan Camus Corporation. The 4m $\times$4m shaking table was used to simulate the earthquake ground motion. the employed input accelerogram was the one recorded as Taft N21E component and the peak ground acceleration(PGA) was scaled depending on the desired level of seismic severity and the time according to dynamic similitude rule. Based on results obtained from shaking table test of this P.C model, the following conclusions were drawn . (1) As far as test specimen is concerned, the seismic safety factors turns out to be 7~8. (2)P.C model has damping ratio of about8% which is twice larger than in-situ R.C. structure. And (3)this model has global displacement ductility ratio of 2~3 through the energy dissipation by opening and sliding of joints.

  • PDF

Quantifying Architectural Impact of Liquid Cooling for 3D Multi-Core Processors

  • Jang, Hyung-Beom;Yoon, Ik-Roh;Kim, Cheol-Hong;Shin, Seung-Won;Chung, Sung-Woo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권3호
    • /
    • pp.297-312
    • /
    • 2012
  • For future multi-core processors, 3D integration is regarded as one of the most promising techniques since it improves performance and reduces power consumption by decreasing global wire length. However, 3D integration causes serious thermal problems since the closer proximity of heat generating dies makes existing thermal hotspots more severe. Conventional air cooling schemes are not enough for 3D multi-core processors due to the limit of the heat dissipation capability. Without more efficient cooling methods such as liquid cooling, the performance of 3D multi-core processors should be degraded by dynamic thermal management. In this paper, we examine the architectural impact of cooling methods on the 3D multi-core processor to find potential benefits of liquid cooling. We first investigate the thermal behavior and compare the performance of two different cooling schemes. We also evaluate the leakage power consumption and lifetime reliability depending on the temperature in the 3D multi-core processor.

발파하중이 인접 댐에 미치는 진동영향에 대한 연계해석적 검토 (Coupled analysis for the influence of blasting-induced vibration on adjacent dam)

  • 박인준;김성인;남기천;곽창원
    • 한국터널지하공간학회 논문집
    • /
    • 제6권1호
    • /
    • pp.41-50
    • /
    • 2004
  • 본 논문에서는 기존댐 인접지에 터널구조물을 건설하기 위한 발파시, 폭괴하중으로 인한 지반진통이 댐 제체와 간극수암에 마치는 영향을 고찰하였다. 댐의 안정성 검토는 발파시 발생하는 코어부의 최대입자속도 (Peak Particle Velocity)를 계산하여 수행하였다. 간극수와 지반진동간의 상호 연계해석을 위하여 댐 제체에 대한 정상상태 흐름해석을 수행하여 간극수압 분포를 파악하고, 유발된 과잉간극수암 및 유효응력분포로 발파하중이 인접지반에 미치는 영향을 분석하였다. 또한 발파와 같은 급속하중 재하 후 과잉간극수압의 증가 및 소산현상 해석을 위하여 Finn & Byrne Model을 적용하여 하중재하 전후의 유효응력 변화양상을 검토하였다.

  • PDF

Probabilistic seismic assessment of mega buckling-restrained braced frames under near-fault ground motions

  • Veismoradi, Sajad;Darvishan, Ehsan
    • Earthquakes and Structures
    • /
    • 제15권5호
    • /
    • pp.487-498
    • /
    • 2018
  • Buckling-restrained braces are passive control devices with high level of energy dissipation ability. However, they suffer from low post-yield stiffness which makes them vulnerable to severe ground motions, especially near-field earthquakes. Among the several methods proposed to improve resistance of BRB frames, mega-brace configuration can be a solution to increase frame lateral strength and stiffness and improve distribution of forces to prevent large displacement in braces. Due to the limited number of research regarding the performance of such systems, the current paper aims to assess seismic performance of BRB frames with mega-bracing arrangement under near-field earthquakes via a detailed probabilistic framework. For this purpose, a group of multi-story mega-BRB frames were modelled by OpenSEES software platform. In the first part of the paper, simplified procedures including nonlinear pushover and Incremental Dynamic Analysis were conducted for performance evaluation. Two groups of near-fault seismic ground motions (Non-pulse and Pulse-like records) were considered for analyses to take into account the effects of record-to-record uncertainties, as well as forward directivity on the results. In the second part, seismic reliability analyses are conducted in the context of performance based earthquake engineering. Two widely-known EDP-based and IM-based probabilistic frameworks are employed to estimate collapse potential of the structures. Results show that all the structures can successfully tolerate near-field earthquakes with a high level of confidence level. Therefore, mega-bracing configuration can be an effective alternative to conventional BRB bracing to withstand near-field earthquakes.

Study of stability and evolution indexes of gobs under unloading effect in the deep mines

  • Fu, Jianxin;Song, Wei-Dong;Tan, Yu-Ye
    • Geomechanics and Engineering
    • /
    • 제14권5호
    • /
    • pp.439-451
    • /
    • 2018
  • The stress path characteristics of surrounding rock in the formation of gob were analysed and the unloading was solved. Taking Chengchao Iron Mine as the engineering background, the model for analysing the instability of deep gob was established based on the mechanism of stress relief in deep mining. The energy evolution law was investigated by introducing the local energy release rate index (LERR), and the energy criterion of instability of surrounding rock was established based on the cusp catastrophe theory. The results showed that the evolution equation of the local energy release energy of the surrounding rock was quartic function with one unknown and the release rate increased gradually during the mining. The calculation results showed that the gob was stable. The LERR per unit volume of the bottom structure was relatively smaller, which mean the stability was better. The LERR distribution showed that there was main energy release in the horizontal direction and energy concentration in the vertical direction which meet the characteristics of deep mining. In summary, this model could effectively calculate the stability of surrounding rock in the formation of gob. The LERR could reflect the dynamic process of energy release, transfer and dissipation which provided an important reference for the study of the stability of deep mined out area.

Evaluation of the seismic performance of off-centre bracing system with ductile element in steel frames

  • Bazzaz, Mohammad;Kheyroddin, Ali;Kafi, Mohammad Ali;Andalib, Zahra
    • Steel and Composite Structures
    • /
    • 제12권5호
    • /
    • pp.445-464
    • /
    • 2012
  • In order to evaluate the dynamic behavior of passive energy dissipation system, two steps need to be considered for prediction of structural response in the presence of ductile element in an off-centre bracing system. The first is a detailed analysis of the proposed ductile element and the second is the effect of this ductile element on an off-centre bracing system. The use of ductile bracing system is expanding in steel structures in order to increase the force reduction factor. Therefore, regarding the nonlinear behavior of steel material used in an off-centre bracing systems and using ductile element in OBS bracing systems, the seismic evaluation of the mentioned systems seems to be necessary. This paper aims to study linear and nonlinear behavior of steel frames with off-centre bracing system and ductile element, in order to get the best position of these bracing elements. To achieve this purpose, the modeling has been done with ANSYS software. The optimum eccentricity has been obtained by modeling three steel frames with different eccentricities and evaluating the results of them. The analytical results showed that the model OBS-C with 0.3 eccentricities has higher performance among the models.