• Title/Summary/Keyword: Dynamic Analyzer

Search Result 213, Processing Time 0.032 seconds

Test Method for Composites Material Properties under High Temperature(I) (복합재의 고온 특성 평가를 위한 시험 기법연구(I))

  • Kil, Hyung-Bae;Yoon, Sung-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.259-261
    • /
    • 2012
  • The effect of high-temperature on the flexural modulus of epoxy resin were evaluated using universal testing machine with 3-point bending and dynamic mechanical analyzer. Temperatures of $30^{\circ}C$, $100^{\circ}C$, and $140^{\circ}C$ were considered for flexural test. The specimens having aspect ratio of 16, 32, and 40 were used. The results of storage modulus from DMA were similar to those from flexural test along with given temperatures. It is found that the flexural modulus increased with increasing aspect ratio and the specimen having aspect ratio of above 32 would be suitable for the evaluation of composite material properties under high temperature condition.

  • PDF

Evaluation of dynamic behavior of coagulation-flocculation using hydrous ferric oxide for removal of radioactive nuclides in wastewater

  • Kim, Kwang-Wook;Shon, Woo-Jung;Oh, Maeng-Kyo;Yang, Dasom;Foster, Richard I.;Lee, Keun-Young
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.738-745
    • /
    • 2019
  • Coprecipitation using hydrous ferric oxide (HFO) has been effectively used for the removal of radionuclides from radioactive wastewater. This work studied the dynamic behavior of HFO floc formation during the neutralization of acidic ferric iron in the presence of several radionuclides by using a photometric dispersion analyzer (PDA). Then the coagulation-flocculation system using HFO-anionic poly acrylamide (PAM) composite floc system was evaluated and compared in seawater and distilled water to find the effective condition to remove the target nuclides (Co-60, Mn-54, Sb-125, and Ru-106) present in wastewater generated in the severe accident of nuclear power plant like Fukushima Daiichi case. A ferric iron dosage of 10 ppm for the formation of HFO was suitable in terms of fast formation of HFO flocs without induction time, and maximum total removal yield of radioactivity from the wastewater. The settling time of HFO flocs was reduced by changing them to HFO-PAM composite floc. The optimal dosage of anionic PAM for HFO-anionic PAM floc system was approximately 1-10 ppm. The total removal yield of Mn-54, Co-60, Sb-125, Ru-106 radionuclides by the HFO-anionic PAM coagulation-flocculation system was higher in distilled water than in seawater and was more than 99%.

Synthesis and Properties of Bio-Thermoplastic Polyurethanes with Different Isocyanate Contents

  • Li, Xiang Xu;Sohn, Mi Hyun;Cho, Ur Ryong
    • Elastomers and Composites
    • /
    • v.54 no.3
    • /
    • pp.225-231
    • /
    • 2019
  • Bio-based polyester polyol was synthesized via esterification between azelaic acid and isosorbide. After esterification, bio-based polyurethanes were synthesized using polyester polyol, 1,3-propanediol as the chain extender, and 4,4'-diphenylmethane diisocyanate, in mixing ratios of 1:1:1.5, 1:1:1.8, 1:1:2, and 1:1:2.3. The bio TPU (Thermoplastic Polyurethane) samples were characterized by using FT-IR (Fourier Transform Infrared Spectroscopy), TGA (Thermal Gravimetric Analysis), DSC (Differential Scanning Calorimetry), and GPC (Gel Permeation Chromatography). The mechanical properties (tensile stress and hardness) were obtained by using UTM, a Shore A tester, and a Taber abrasion tester. The viscoelastic properties were tested by an Rubber Processing Analyzer in dynamic strain sweep and dynamic frequency test modes. The chemical resistance was tested with methanol by using the swelling test method. Based on these results, the bio TPU synthesized with the ratio of 1:1:2.3, referred to as TPU 4, showed the highest thermal decomposition temperature, the largest molecular weight, and most compact matrix structure due to the highest ratio of the hard segment in the molecular structure. It also presented the highest tensile strength, the largest elongation, and the best viscoelastic properties among the different bio TPUs synthesized herein.

Studies on The Free Vibrational Properties of Traditional and Replaceable Species for Sounding Board (향판용(響板用) 관행수종(慣行樹種)과 대체가능수종(代替可能樹種)의 자유진동적(自由振動的) 성질(性質)에 관한 연구(硏究))

  • Kang, Wook;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.48-64
    • /
    • 1988
  • This study was carried out to investigate the free vibrational properties of traditional and replaceable species for sounding board, using piezoelectrical accelerometer and signal analyzer. In the study, the frequency equations of free-free beam carrying a concentrated mass in the transverse vibration and of free-mass beam in the longitudinal vibration were used. The results obtained were as follows. 1. Average values of dynamic modulus of rigidity of Korean commercial species measured were as follows. Paulownia tomatosa (Thunb.) Steudel: $5.590\times10^9\;dyne/cm^2$ Tilia amurensis Rupr.: $5.414\times10^9\;dyne/cm^2$ Macckia amurensis Rupr.: $10.044\times10^9\;dyne/cm^2$ Fraxinus mandshurica Rupr.: $8.876\times10^9\;dyne/cm^2$ Ulmus davidiana var.japonica Nakai: $8.677\times10^9\;dyne/cm^2$ Pinus rigida Miller: $6.33\times10^9\;dyne/cm^2$ Fraxinus rhynchophylla Hance: $4.666\times10^9\;dyne/cm^2$ 2. The ratio of dynamic transverse Young's modulus to dynamic modulus of rigidity, $E_T/G_{LT}$, was 24.922 for Fraxinus rhynchophylla Hance, which was the highest, 7.317 for Paulownia tomentosa (Thunb.) Steudel, which was the lowest among Korean commercial species measured. 3. The value of longitudinal dynamic Young's modulus was about 3.7% and 19.8%, respectively, higher than those of transverse dynamic and static Young's modulus. The value of transverse dynamic Young's modulus was about 15.5% higher than that of static Young's modulus. 4. Predicted value of MOR in terms of correlation coefficient by transverse dynamic Young's modulus was slightly higher than that of static Young's modulus, but no significance was found out. 5. Transverse dynamic Youne's modulus was $(2.002\pm0.288)\times10^{11}\;dyne/cm^2$ for Fraxinus mandshurlca Rupr., which was the highest, $(0.601\pm0.100)\times10^{11}\;dyne/cm^2$ for Paulownia tomentosa (Thunb.) Steudel, which was the lowest among Korean commercial species measured. The sound velocity of sitka spruce was 5,685 m/sec, which was the highest. 6. Internal friction of Paulownia tomentosa (Thunb.) Steudel was shown the lowest value among Korean commercial species, $(8.795\pm1.795)\times10^{-3}$, but was higher than that of sitka spruce, $(7.331\pm0.991)\times10^{-3}$. Internal friction was shown negative correlation with density and dynamic Young's modulus, respectively. 7. K value was affected largely by internal friction and was the highest, $2.225\times10^8$ for Paulownia tomentosa (Thunb.) Steudel and was the lowest, $0.550\times10^8$ for Fraxinus rhynchophylla Hance. K value of Paulownia tomentosa (Thunb.) Steudel was higher than that of sitka spruce and K values of melapi and cottonwood, which have been considered to be replaceable species with sitka spruce in the piano industry, were lower than those of Paulownia tomentosa (Thunb.) Steudel and mill amurensis Rupr.

  • PDF

Low Frequency Noise Characteristics of the 180nm MOSFETs

  • Yoon, Young-Chang;Lee, Ho-Cheol;Kang, In-Man;Shin, Hyung-Cheol
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.861-864
    • /
    • 2005
  • Performing accurate and repeatable low frequency noise measurement is critical for modeling and simulation of flicker noise. Through the accurate and repeatable on-wafer measurement, low frequency noise characteristics of the 0.18 ${\mu}m$ n-MOSFETs are discussed. And on-wafer flicker noise measurement system is presented. The on-wafer measurement system consists of cascade probe station, low noise current amplifier (SR570), and dynamic signal analyzer (HP35670A).

  • PDF

A Study on the Vibration Reduction and Performance Improvement of the CD/DVD is used from the Vehicle (자동차용 CD/DVD 데크의 진동 저감 및 성능 향상에 관한 연구)

  • Park, Young-Pil;Jung, Du-Han;Chung, Jin-Tal
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.799-804
    • /
    • 2004
  • Dynamic characteristic of CD/DVD deck for vehicle is analyzed in this paper. Generally CD/DVD deck for vehicle is used from inferior environment with the vibration of the vehicle and shock of outside and so on. Therefore it must have the structure which is stabilized from the vibration to prevent read error. For this purpose, vibration characteristic of the deck for vehicle should be identified. To analyze characteristic of the deck system, we perform the signal analysis and modal testing using the FFT analyzer. Also we change the design factor degrading the performance of the deck system and verify the efficiency improvement using the acceleration measurement occurring to the sound discontinuation.

  • PDF

Development of Composite Bipolar Plate for PEMFC (고분자 전해질 연료전지용 복합수지 분리판 개발)

  • Kang, Hyun-Min;Han, In-Su;Lim, Chan
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.3-7
    • /
    • 2007
  • Graphite/polymer composite bipolar plates for PEMFC are successfully developed, and their typical properties are superior to commercially available ones. Thermal property of the developed bipolar plate was evaluated by dynamic mechanical analyzer, and the results were compared to commercial ones. The specimens were immersed into the deionized water bath at $80^{\circ}$... for 1500hrs to evaluate dimensional stability and durability. Dimension, weight of the specimens as well as extraction conductivity was measured as each 500hrs. Fully molded bipolar plates without any machining or milling were also prepared using a specially developed mold, and they were applied to the fuel cell performance test. Results were compared to the machined commercial bipolar plate.

  • PDF

The Development of the Beam Rotating Actuator Based on the Bimorph Piezo Material (Bimorph 피에조 소자를 이용한 빔 회전 구동기의 개발)

  • 이정현;한창수;김수현;곽윤근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.450-453
    • /
    • 1995
  • The beam rotating actuator, which can be utilized to improve the data transfer rate for the optical disk systems, has been developed. It can employ a newly developed laser beam rotating actuator for putting multi-beam spots on more than one track on the optical disk simultaneously. Therefore, It has to maintain up to .+-.0.01 .deg. resolution and high bandwidth performance. In this these, the Dove prism is used for the beam rotating actuator based on bimorph piezo material. The performance of the beam rotating actuator is verified since the dynamics ferquency performance is measured using the dynamic analyzer and the attached stain gage sensor. the beam rotating angle performance is also examined since the long range beam reflection character is utilized.

  • PDF

Measurements of the Mechanical Properties of Electroplated Gold Microstructure (전해 도금된 마이크로 금 구조물의 기계적 특성 측정)

  • Baek, Chang-Wong;Kim, Yong-Kweon;Ahn, Yoo-Min
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.2
    • /
    • pp.86-95
    • /
    • 2001
  • Mechanical properties of electroplated gold microstructures were determined from the micromachined beam structures. Cantilever and bridge beam structures of different length were fabricated by electroplating-surface micromachining technique, which is specially designed to realize an anchor structure close to an ideal fixed-boundary condition. Fabricated beams were electrostatically excited and their resonance frequencies were measured by optical system composed of laser displacement meter with dynamic signal analyzer. Young's modulus and mean residual stress were calculated from the measured frequencies of microbeams. In addtion, stress gradient was measured using deformation of released cantilever beam structure.

  • PDF

Aging Characteristics of Glass Fabric/Phenolic Composites in Train Carbody (철도차량용 유리섬유직물/페놀릭 복합재의 가속노화 특성)

  • Yoon Sung-Ho;Nam Jung-Pyo;Hwang Young-Eun;Shin Kwang-Bok
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.352-357
    • /
    • 2004
  • In this study. the effects of combined environmental factors on mechanical and thermal analysis properties of graphite/epoxy composites were evaluated through a 2.5KW accelerated environmental aging tester. Environmental factors such as temperature. moisture, and ultraviolet were considered. A xenon-arc lamp was utilized for ultraviolet light. and exposure times of up to 3000 hours were applied. Several types of specimens - tensile, bending, and shear specimens those are warp direction and fill direction were used to investigate the effects of environmental factors on mechanical properties of the composites. The glass fabric $\sharp$650/AP300 was used for the fabrication of specimens. Mechanical degradations for tensile, bending and shear properties were evaluated through a UTM. Also. storage shear modulus. loss shear modulus, and tan $\delta$ were measured as a function of exposure times through a dynamic mechanical analyzer. Finally exposed surfaces of the composites were examined using II scanning electron microscope.

  • PDF