• 제목/요약/키워드: Dye penetration test

검색결과 64건 처리시간 0.031초

THE EFFECTS OF SEALING ON THE PLASMA-SPRAYED OXIDE-BASED COATINGS

  • Kim, Hyung-Jun;Sidoine Odoul;Kweon, Young-Gak
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.53-58
    • /
    • 2002
  • Electrical insulation and mechanical properties of the plasma sprayed oxide ceramic coatings were studied before and after the sealing treatment of the ceramic coatings. Plasma sprayed A1$_2$O$_3$-TiO$_2$ coating as the reference coating was sealed using three commercial sealants based on polymer. Penetration depth of the sealants to the ceramic coating was evaluated directly from the optical microscope using a fluorescent dye. It is estimated that the penetration depth of the sealants to the ceramic coating is from 0.2 to 0.5 mm depending on the sealants used. The preliminary test results with a DC puncture tester imply that the dielectric breakdown voltage mechanism of plasma sprayed ceramic coatings has been determined to be a corona mechanism. Dielectric breakdown voltage of the as-sprayed and as-ground samples have shown a linear trend with regard to the thickness showing an average dielectric strength of 20 kV/mm for the thickness scale studied. It is also shown that grinding the coating before sealing and adding fluorescent dye do not agent the penetration depth of sealants. All of the microhardness, two-body abrasive wear resistance, bond strength, and surface roughness of the ceramic coating after the sealing treatment are improved. The extent of improvement is different from the sealants used. However, three-point bending stress of the ceramic coating after the sealing treatment is decreased. This is attributed to the reduced micro-crack toughening effect since the cracks propagate easily through the lamellar of the coating without crack deflection and/or branching after the sealing treatment.

  • PDF

포해태를 이용한 묘염에 대한 연구 (A study on the paint dyeing by Gloiopeltis paste)

  • Sul, Jung Hwa;Go, Pyoung Nyoun;Choi, Suk Chul
    • 한국염색가공학회지
    • /
    • 제9권2호
    • /
    • pp.32-40
    • /
    • 1997
  • This study was carried out to examine the effect of paint dyeing by Gloiopeltis paste in the various painting sizes and concentrations of paste. In the tonality diagram of Lab, surface colors were changed to +a(red), +b(yellow) and -b(blue) by treating of Gloiopelis paste and L value was the tendency of increasing. The penetration decreased with increasing concentration of paste, except for 3% of red and yellow. While it was decreased steadily in the case of Nue. The best penetration of dye was at 3% of concentration of Gloiopeltis paste and it's viscosity was measured 1500cps. As concentration of paste increased, ${\Delta}E_{ab}$increased after 40 hr. irradiation and water fastness and washing fastness test in red and blue. But in the case of ${\Delta}E_{ab}$yellow decreased slightly or not changed.

  • PDF

가변 광도에 따른 복합레진의 기계적 물성 및 변연누출도 변화 (MECHANICAL PROPERTIES AND MICROLEAKAGE OF COMPOSITE RESIN MATERIALS CURED BY VARIABLE LIGHT INTENSITIES)

  • 한승렬;민경산;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제28권2호
    • /
    • pp.134-145
    • /
    • 2003
  • Mechanical properties and microleakage of two composites [conventional hybrid type DenFil (VERICOM Co., Anyang, Korea) / micro matrix hybrid type Esthet X (Dentsply Caulk, Milford, DE, U.S.A.)] were evaluated to assess whether variable light intensity curing is better than conventional curing technique. Curing was done for 40 seconds in two ways of 2 step soft-start technique and 5 step ramping technique. Three kinds of light intensities of 50, 100, $200{\;}mW/\textrm{cm}^2$ were initially used for 10, 20, 30 seconds each and the maximum intensity of $600 {\;}mW/\textrm{cm}^2$ was used for the rest of curing time in a soft-start curing tech nique. In a ramping technique, curing was done with the same initial intensities and the light intensity was increased 5 times with the same rate to the maximum intensity of $600{\;}mW/\textrm{cm}^2$. After determining conditions that showed no different mechanical properties with conventional technique, Esthet X composite was filled in a class V cavity, which dimension was $4{\times}3{\times}1.5{\;}mm$ and cured under those conditions. Microleakage was evaluated in two ways of dye penetration and maximum gap estimation through SEM observation. ANOVA and Spearman's rho test were used to confirm any statistical significance among groups. The results were as follows : 1 Several curing conditions of variable light intensities resulted in the similar mechanical properties with a conventional continuous curing technique, except conditions that start curing with an initial light intensity of $50{\;}mW/\textrm{cm}^2$. 2. Conventional and ramping techniques were better than soft-start technique in mechanical properties of microhardness and compressive strength. 3. Soft-start group that started curing with an initial light intensity of $100{\;}mW/\textrm{cm}^2$ for 10 seconds showed the least dye penetration. Soft-start group that started curing with an initial light intensity of $200{\;}mW/\textrm{cm}^2$ for 10 seconds showed the smallest marginal gap, if there was no difference among groups. 4. Soft-start technique resulted in better dye-proof margin than conventional technique(p=0.014) and ramping technique(p = 0.002). 5. There was a very low relationship(p=0.157) between the methods of dye penetration and marginal gap determination through SEM evaluation. From the results of this study, it was revealed that ramping technique would be better than conventional technique in mechanical properties, however, soft-start technique might be better than conventional one in microleakage. It was concluded that much endeavor should be made to find out the curing conditions, which have advantages of both aspects or to solve these kinds of problems through a novel idea of polymerization.

Thermafil 충전법의 근관폐쇄성에 관한 연구 (A STUDY ON THE SEALING ABILITY OF THE THERMAFIL ENDODONTIC OBTURATION TECHNIQUE)

  • 박찬제;여인호;임성삼
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.517-529
    • /
    • 1996
  • The purpose of this study was to evaluate the apical sealing ability of the Thermafil endodontic obturation technique and to compare it with lateral condensation technique. 42 straight canals from extracted human anterior teeth and 42 curved canals(> $25^{\circ}$) from maxillary and mandibular molar teeth were selected. And 80 of them were divided into four groups, 20 canals respectively. The teeth in prior two groups had straight canals and the other two groups had curved canals. The rest of four canals served as positive and negative controls. After resecting anatomical crowns, all canals were prepared using a standard step-back technique. Lateral condensation was used to obturate two groups, one group of straight ones the other curved. And Thermafil obturators were also used in the same two groups. Obturated teeth were infiltrated by India ink for a week, decalcified and cleared with 5% nitric acid and methyl salicylate. The apical leakage and the frequency of filled lateral and accessory canals were measured with stereomicroscope and also apical extrusion of sealer and gutta-percha and obturation time were checked and the data were analyzed statistically(one-way ANOVA, t-test, Chi-square test). The results were as follows : 1. There was no significant difference in the degree of dye penetration between Thermafil and lateral condensation groups(p>0.05). 2. Apical extrusion of sealer and gutta-percha occurred significantly more often with Thermafil obturators in straight canals(p<0.05), but not significantly different in curved canals(p>0.05). 3. Canal obturation time with Thermafil obturators was significantly faster than lateral condensation (p<0.05). 4. The Thermafil groups showed a higher frequency of filled lateral and accessory canals than in the lateral condensation groups. But the difference was not statistically significant (p>0.05).

  • PDF

각종 근관충전법의 치근단 폐쇄효과에 관한 연구 (AN EXPERIMENTAL STUDY ON THE SEALING ABILITY OF DIFFERENT ROOT CANAL OBTURATION METHODS)

  • 허승면;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.143-154
    • /
    • 1991
  • The purpose of this study was to evaluate the sealing ability of five obturation methods in conjunction with sealer. Fifty extracted upper and lower anterior teeth were selected and the access cavities were prepared lingually with a round bur. The working length was determined with a #15K file, and the root canals were instrumented with a #40K file 1mm short of the apical foramen. The apical third of root canal was flared by step-back technique and the coronal two thirds of root canal using #2 - 3 Gates Glidden drills. And then, the teeth were randomly assigned to five groups of 10 teeth each. A thin coat of Tubliseal was placed into the canal into the canal using the # 35 reamer and the canals were filled by lateral condensation, vertical condensation, ultrasonic activated lateral condensation, ULTRAFIL injecting, and McSpadden compaction methods. All teeth were stored in 100 % relative humidity at 31c for 48 hours. The roots were suspended in 2 % methylene blue solution for 48 hours, left to dry for 24 hours and then, half side of root was removed longitudinally using the fissure bur. A Boley gauge wes used to measure the distance, to the nearest 0.1mm, from the apical foramen to the most coronal level of dye penetration. The measurement of dye penetration was statistically compared by Duncan's multiple range test The results were as follows 1. Ultrasonic group showed the best sealing ability among the all experimental groups, but there were statistically no significant difference in the sealing ability between ultrasonic group and vertical condensation group. 2. There were no statistically significant difference in the sealing ability among the lateral, vertical, and ultrasonic groups. 3. McSpadden group showed the worst sealing ability among the all exprimental groups.

  • PDF

Marginal microleakage of cervical composite resin restorations bonded using etch-and-rinse and self-etch adhesives: two dimensional vs. three dimensional methods

  • Khoroushi, Maryam;Ehteshami, Ailin
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.83-90
    • /
    • 2016
  • Objectives: This study was evaluated the marginal microleakage of two different adhesive systems before and after aging with two different dye penetration techniques. Materials and Methods: Class V cavities were prepared on the buccal and lingual surfaces of 48 human molars. Clearfil SE Bond and Single Bond (self-etching and etchand-rinse systems, respectively) were applied, each to half of the prepared cavities, which were restored with composite resin. Half of the specimens in each group underwent 10,000 cycles of thermocycling. Microleakage was evaluated using two dimensional (2D) and three dimensional (3D) dye penetration techniques separately for each half of each specimen. Data were analyzed with SPSS 11.5 (SPSS Inc.), using the Kruskal-Wallis and Mann-Whitney U tests (${\alpha}=0.05$). Results: The difference between the 2D and 3D microleakage evaluation techniques was significant at the occlusal margins of Single bond groups (p = 0.002). The differences between 2D and 3D microleakage evaluation techniques were significant at both the occlusal and cervical margins of Clearfil SE Bond groups (p = 0.017 and p = 0.002, respectively). The difference between the 2D and 3D techniques was significant at the occlusal margins of non-aged groups (p = 0.003). The difference between these two techniques was significant at the occlusal margins of the aged groups (p = 0.001). The Mann-Whitney test showed significant differences between the two techniques only at the occlusal margins in all specimens. Conclusions: Under the limitations of the present study, it can be concluded that the 3D technique has the capacity to detect occlusal microleakage more precisely than the 2D technique.

Micro-CT를 이용한 복합 레진 수복물 미세 누출도의 정량 분석 (Quantitative Micro-CT Evaluation of Microleakage in Composite Resin Restorations)

  • 이상익;현홍근;김영재;김정욱;이상훈;김종철;한세현;장기택
    • 대한소아치과학회지
    • /
    • 제34권2호
    • /
    • pp.222-233
    • /
    • 2007
  • 치과 수복 재료 검사 시 가장 중요하고 기본적인 것은 치아와 수복물 사이의 미세누출에 대한 평가이다. 미세 누출을 평가하는 방법은 여러 가지가 있지만 이들 대부분은 많은 단점들을 가지고 있다. 최근에 개발된 미세 단층촬영법(micro-CT)을 이용하면 시편을 비파괴적으로 처리하여 특정 밀도에 해당하는 부분의 3차원적 영상을 얻을 수 있으므로, 이를 이용하면 정확하고 정량적인 미세누출 평가도 가능할 것이다. 이 연구의 목적은 micro-CT를 사용하여, 레진 수복물의 미세 누출도를 정량적이고 비파괴적으로 측정할 수 있는 새로운 방법을 찾아내고, 이 새로운 방법을 기존의 색소 침투법과 비교해보는 것이다. 이를 위해, 위의 두 가지 방법을 사용하여 두 종류의 상아질 접착 시스템의 미세누출도가 평가되었다. 사람의 건전 소구치 40개를 임의로 20개씩 두 군으로 나누고 다음과 같이 처리하였다. Group 1 : $Adper^{TM}$ Singe Bond 사용 후 제 V급 와동 레진 수복, Gourp 2 : $Adper^{TM}\;Promp^{TM}$ L-pop 사용 후 제 V급 와동 레진 수복 모든 치아의 5급 와동은 $Filtek^{TM}$ Supreme으로 수복하였다. 그 후 각 군 중 10개의 치아는 micro-CT를 사용하여 미세 누출도를 평가하고, 나머지 10개는 기존의 색소 침투법으로 평가하였다. 이 연구의 결과는 다음과 같았다. 1. Micro-CT를 사용한 경우, 1군은 2군보다 통계적으로 유의성 있게 적은 양의 미세 누출을 보였다(p<0.01). 2. 기존의 색소 침투법을 사용한 경우에서 1군은 2군보다 적은 미세누출을 보였으며 이는 통계적으로 유의성이 있었다. (p<0.01). 3. 두 군간의 미세 누출도는 micro-CT를 사용한 방법에서 더 현저한 차이를 보였다. 4. 두 가지 방법 모두에서 법랑질 변연 부분보다 상아질 변연 부분에서 더 많은 미세 누출을 보였다.

  • PDF

반복하중을 받는 틸팅열차용 복합재 차체구조의 내구성 평가 (Durability Evaluation of a Composite Carbody for Korean Tilting Train under Repeated Loadings)

  • 정종철;서승일;김정석
    • 한국철도학회논문집
    • /
    • 제10권1호
    • /
    • pp.39-44
    • /
    • 2007
  • This rafer explains a durability test of a large train car body made of carbon/epoxy composite material. The composite car body with the length of 23m was manufactured as a sandwich structure composed of an aluminum honeycomb core and CF1263 woven fabric carbon/epoxy faces. In order to evaluate durability of the composite car body, it was excited by two 500kN capacity hydraulic actuators installed underneath the body bolster. The natural frequency of the composite car body under full weight condition was found to be 4.33Hz. Based on this result, the excitation frequency and displacement of 5Hz and ${\pm}1.0mm$, respectively, were used as inputs for the durability test. The test was conducted for $2{\times}10^6$ cycles. During the test, the nondestructive tests using X-ray radiography and dye penetration method was performed to determine the presence of the cracks. Upon completion of the test, no cracks were found.

접착제의 접착변수가 레진계 근관충전제의 근단밀폐효과에 미치는 영향 (The effects of total-etch, wet-bonding, and light-curing of adhesive on the apical seal of a resin-based root canal filling system)

  • 류원일;손원준;백승호;이인한;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제36권5호
    • /
    • pp.385-396
    • /
    • 2011
  • 연구목적: 본 연구는 치근벽의 전처리 개념과 접착제의 중합방법이 레진계 근관충전제의 치근단 밀폐능에 미치는 영향을 평가하였다. 연구 재료 및 방법: 3가지 다른 접착변수를 조합하여 충전한 Resilon-RealSeal 시스템의 근단미세누출을 색소침투법을 이용하여 통상의 가타퍼쳐 충전과 비교하였다. 실험군은 자가부식형 RealSeal primer와 이중중합형 RealSeal sealer를 이용하여 Resilon 충전한 SEDC군, 산부식없이 Scotchbond Multi-Purpose primer를 적용한 후 접착제는 광중합하고 Resilon을 충전한 NELC군, 및 Scotchbond Multi-Purpose의 접착강화제와 접착제를 total etch/wet bonding과 광중합의 술식을 정확하게 지켜서 Resilon을 충전한 TELC군으로 구분하였다. 대조군(GPCS)에서는 통상의 AH26 plus sealer를 사용하여 가타퍼쳐를 충전 하였다. 결과: 치아장축방향의 색소침투는 TELC군에서 GPCS군과 SEDC군에 비해 유의하게 작았다(Kruskal-Wallis test, p < 0.05). 횡단면의 미세누출 점수도 TELC군이 근첨으로부터 2 - 5 mm의 범위에서 다른 군에 비해 유의하게 낮았다(Kruskal-Wallis test, p < 0.05). 결론: 레진계 근관충전제를 사용 시에는, 자가부식형 전처리제와 이중중합형 sealer보다는, total etch/wet bonding 개념과 적절한 광중합을 도모하는 전처리제 및 접착제의 사용이 치근단 미세누출을 감소시키므로 추천된다.

동적하중 하에서 근관치료용 임시충전재의 미세누출의 평가 (Microleakage of Endodontic Temporary Restorative Materials under Dynamic Loading)

  • 정동호;노영신;이해두;장훈상;류현욱;민경산
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2008년도 Spring Scientific Meeting(the 129th) of Korean Academy if Conservative Dentistry
    • /
    • pp.198-203
    • /
    • 2008
  • 본 연구의 목적은 동적하중 하에서 네 종류의 근관치료용 임시충전재의 밀폐효과를 비교하는 것이다. 44개의 건전한 인간 대구치에 표준화된 근관와동을 형성한 후 Caviton, MD-Temp, IRM 및 ZOE를 이용하여 충전하였다. 이 후, 1% 메틸렌블루 용액에 담근 상태에서 반복하중기를 이용하여 1 Hz의 속도로 98 N의 하중을 기능교두에 1,000번 가한 다음 시편을 양분해 미세누출을 평가하고 one-way ANOVA (p = 0.05)와 사후 검정으로 Duncan's multiple range tests로 통계분석 하였다. Caviton 군과 MD-Temp군이 IRM군과 ZOE군보다 통계적으로 적은 미세누출을 보였으며 (p < 0.05), 본 실험결과로 볼 때 Caviton과 MD-Temp가 IRM과 ZOE보다 동적하중 하에서 근관와동 밀폐효과가 우수하다고 사료된다.

  • PDF