Comparison of physical properties and dye photo-degradation effects for $carbon/TiO_2$ complexes

  • Oh, Won-Chun;Lim, Chang-Sung
    • 한국결정성장학회지
    • /
    • 제17권5호
    • /
    • pp.196-203
    • /
    • 2007
  • We have studied a method for the preparation of hybrid $carbon/TiO_2$ complexes involving pitch coating, pitch binding and the penetration of titanium n-butoxide(TNB) solution with porous carbon. The photocatalysts were investigated with surface textural properties and SEM morphology, structural crystallinity and elemental identification between porous carbon and $TiO_2$, and dye decomposition performance. For the all $carbon/TiO_2$ complexes prepared by some kinds of different methods, the excellent photocatalytic effect for dye degradation should be attributed to the both effects between photo-decomposition of the supported $TiO_2$ and adsorptivity of the porous carbons.

Post-Space형성시기가 치근단폐쇄에 미치는 영향에 관한 실험적 연구 (THE EFFECT OF POST-SPACE PREPARATION TIME ON THE APICAL SEAL OF ENDODONTICALLY TREATED TEETH)

  • 문을원;이인숙;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제13권1호
    • /
    • pp.151-158
    • /
    • 1988
  • The purpose of this study was to evaluate the effect of canal filling methods and post-space preparation time on the apical seal of endodontically treated teeth. Seventy-six single-rooted human teeth were divided into 6 groups and each tooth was obturated and prepared post-space according to the purpose of this study. After all specimens were immersed in Indian ink, decalcified and cleared, the degree of dye penetration into the root canals observed by magnifying glass (X20) and measured by caliper. The results were as follows: 1. In the thermatic condensation, no significant difference in ink penetration occured when the post-spaces were created immediately after obturation or when they were made a week later. 2. In the lateral condensation, no significant difference in ink penetration existed between teeth whose post-space were prepared immediately or delayed. 3. In comparison of experimental groups and control groups, no significant difference showed when the groups were obturated with McSpadden compactor but when the teeth were laterally condensed, the experimental groups showed less ink penetration than controls. 4. Thermatic condensed teeth with McSpadden compactor were less ink penetration thn laterally condensed teeth.

  • PDF

Antihistamine Effects of Triprolidine from the Transdermal Administration of the TPX Matrix in Rats

  • Shin Sang-Chul;Choi Jun-Shik
    • Archives of Pharmacal Research
    • /
    • 제28권1호
    • /
    • pp.111-114
    • /
    • 2005
  • The antihistamine effects of the triprolidine were studied in rats to determine the feasibility of their enhanced transdermal delivery from the poly (4-methyl-1-pentene) (TPX) matrix system containing penetration enhancer and plasticizer. The antihistamine effects were determined by the Evans blue dye procedure by comparing the changes in vascular permeability increase following the transdermal administration. The vascular permeability increase was significantly reduced by transdermal administration of the triprolidine-TPX system containing triethyl citrate (TEC) and polyoxyethylene-2-oleyl ether (POE). Both the plasticizer and penetration enhancer played an important role in the skin permeation of triprolidine and increased the antihistamine effects. These results showed that the triprolidine-TPX matrix system containing plasticizer and penetration enhancer could be a transdermal delivery system providing the increased antihistamine effects.

각종 근관충전용 시멘트의 미세누출에 관한 연구 (A STUDY ON THE MICROLEAKAGE OF ROOT CANAL SEALERS)

  • 조지선;황호길;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.202-217
    • /
    • 1996
  • The purpose of this study was to compare the degree of microleakage of Glass-Ionomer root canal sealer possessed several enviable properties with that of the other sealers and to evaluate clinical performance. One hundred twenty single-rooted teeth were used in this experiment. The teeth were cleaned mechanically and immersed for 24 hours in 5.25% sodium hypochlorite and clinical crowns then were removed. After the root canals were instrumented using a step-back technique. one hundred twenty single-rooted teeth were divided into five groups of 24 in each. Group 1 : Tubli-Seal(Kerr Co., MI, U.S.A/ZOE-based), lateral condensation Group 2 : Sealapex(Kerr/Sybron, Romulus, MI/ $Ca(OH)_2$-based), lateral condensation Group 3 : AH 26(De Trey Co., Zurich Switzerland/Resin-based), lateral condensation Group 4 : Ketac-Endo(ESPE GMBH & CO. KG Seefeld:oberbay. Germany/ Glass Ionomer Cement-based), lateral condensation Control group : no sealer. lateral condensation And then. the root canals were obturated by lateral condensation technique with gutta-percha and experimental sealers. The control group were obturated without sealer. The teeth were placed in a vacuum chamber for 15 minutes and immersed 2% methylene blue under vacuum for 15 minutes. The teeth were passively stained for 1 week and 2 weeks and were cleared and evaluated for linear dye leakage using Tool maker's microscope(${\times}200$). The results were as follows: 1. There were statistically significant differences in the degree of dye penetration between the control group and experimental groups(p<0.05). 2. In the experimental groups, Sealapex($1.2871{\pm}0.9180mm$) exhibited the lowest mean value of dye penetration, followed by Ketac-Endo($1.4432{\pm}0.8082mm$), AH 26($1.5030{\pm}0.7752mm$) and Tubli-Seal($1.6458{\pm}1.0292mm$)(p>0.05). 3. There were statistically significant differences in the variation of microleakage between 1 week and 2weeks in Tubli-Seal and Seal apex groups (p<0.05). 4. The degree of dye penetration of all groups were increased as the time elapsed and AH 26 showed the lowest variation(+0.11) and Tubli-Seal(+ 1.03) showed the highest variation (p<0.001).

  • PDF

가변 광도에 따른 복합레진의 기계적 물성 및 변연누출도 변화 (MECHANICAL PROPERTIES AND MICROLEAKAGE OF COMPOSITE RESIN MATERIALS CURED BY VARIABLE LIGHT INTENSITIES)

  • 한승렬;민경산;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제28권2호
    • /
    • pp.134-145
    • /
    • 2003
  • Mechanical properties and microleakage of two composites [conventional hybrid type DenFil (VERICOM Co., Anyang, Korea) / micro matrix hybrid type Esthet X (Dentsply Caulk, Milford, DE, U.S.A.)] were evaluated to assess whether variable light intensity curing is better than conventional curing technique. Curing was done for 40 seconds in two ways of 2 step soft-start technique and 5 step ramping technique. Three kinds of light intensities of 50, 100, $200{\;}mW/\textrm{cm}^2$ were initially used for 10, 20, 30 seconds each and the maximum intensity of $600 {\;}mW/\textrm{cm}^2$ was used for the rest of curing time in a soft-start curing tech nique. In a ramping technique, curing was done with the same initial intensities and the light intensity was increased 5 times with the same rate to the maximum intensity of $600{\;}mW/\textrm{cm}^2$. After determining conditions that showed no different mechanical properties with conventional technique, Esthet X composite was filled in a class V cavity, which dimension was $4{\times}3{\times}1.5{\;}mm$ and cured under those conditions. Microleakage was evaluated in two ways of dye penetration and maximum gap estimation through SEM observation. ANOVA and Spearman's rho test were used to confirm any statistical significance among groups. The results were as follows : 1 Several curing conditions of variable light intensities resulted in the similar mechanical properties with a conventional continuous curing technique, except conditions that start curing with an initial light intensity of $50{\;}mW/\textrm{cm}^2$. 2. Conventional and ramping techniques were better than soft-start technique in mechanical properties of microhardness and compressive strength. 3. Soft-start group that started curing with an initial light intensity of $100{\;}mW/\textrm{cm}^2$ for 10 seconds showed the least dye penetration. Soft-start group that started curing with an initial light intensity of $200{\;}mW/\textrm{cm}^2$ for 10 seconds showed the smallest marginal gap, if there was no difference among groups. 4. Soft-start technique resulted in better dye-proof margin than conventional technique(p=0.014) and ramping technique(p = 0.002). 5. There was a very low relationship(p=0.157) between the methods of dye penetration and marginal gap determination through SEM evaluation. From the results of this study, it was revealed that ramping technique would be better than conventional technique in mechanical properties, however, soft-start technique might be better than conventional one in microleakage. It was concluded that much endeavor should be made to find out the curing conditions, which have advantages of both aspects or to solve these kinds of problems through a novel idea of polymerization.

Resilon을 이용한 근관충전 시 수종의 치면처리제에 따른 미세누출 평가 (MICROLEAKAGE OF RESILON: EFFECTS OF SEVERAL SELF-ETCHING PRIMER)

  • 오종현;박세희;신혜진;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제33권2호
    • /
    • pp.133-140
    • /
    • 2008
  • 이 실험의 목적은 Resilon으로 근관충전된 치아에서 자가산부식전처리제에 따른 치근단 미세누출을 평가하고자 함이다. 70개의 단근치를 사용하였고 .04 Taper ProFile을 사용하여 ISO #40까지 근관성형 하였다. 치아는 근관충전 재료와 자가산부식 전처리제에 따라서 15개씩 4개의 실험군과 5개씩 2개의 대조군으로 나누었다. 실험 치아는 치아 장축에 평행하게 잘라내어 염색액의 최대 침투 길이를 측정하였다. 통계분석은 One-way ANOVA test로 분석하였으며 Scheffe test로 사후검정 하였다. 실험결과 자가산부식전처리제를 사용한 2, 3, 4군 사이에서는 통계적으로 유의한 차이를 나타내지 않았다. 그러나 1군과 4군 사이에서는 통계적으로 유의한 차이가 나타났으며 (p < 0.05), 1군에서 가장 적은 치근단 미세누출을 나타냈다. 이 실험 결과에 따르면 Resilon으로 근관충전을 한 치아는 gutta percha와 $AH26^{(R)}$으로 근관충전한 치아와 비교했을 때 더 좋은 치근단 밀폐를 나타내지 않는다는 결론을 얻었으며, Resilon을 사용하여 근관충전을 한 경우에 자가산부식 전처리제의 차이에 따른 치근단 밀폐효과의 차이를 보이지 않는다는 결론을 얻었다.

광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향 (EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.263-272
    • /
    • 2001
  • 저광도 중합법, 펄스 지연 중합법, 초고광도 중합법 등의 광조사 방식이 광중합형 복합레진 수복물에서의 중합수축 응력에 미치는 영향을 알아보기 위해 in vitro에서 미세 누출 실험을 하였다. 80개의 발거된 소구치의 협측면에 5급 와동을 형성하고, 600mW/$cm^2$로 30초간 광조사하는 보통 광도 중합군, 300mW/$cm^2$로 60초간 광조사하는 저광도 중합군, 400mW/$cm^2$로 2초간 광조사하고 5분간 기다린 후 800mW/$cm^2$로 10초간 최종 중합시키는 펄스-지연 중합군, 그리고 1930mW/$cm^2$의 광도로 3초간 광조사하는 초고광도 중합군 등의 4개의 군으로 나누어 hybrid 형의 광중합복합레진을 충전하고 각 군의 방법대로 중합한 후, 변연의 0.5mm 외부에 nail varnish를 도포하고 37$^{\circ}C$, 2% metylene blue 용액에 24시간 동안 침적시켰다. 시편을 아크릴릭 레진에 매몰한 후 수복물의 중앙에서 종절단하여 입체현미경하에서 그 단면을 관찰한 후 법랑질과 상아질 변연으로 나누어 색소의 침투도를 측정하여 다음과 같은 결과를 얻었다. 1. 펄스 지연 중합군의 색소 침투도는 법랑질과 상아질 변연 모두에서 보통광도, 저광도 및 초고광도 중합군과 유의한 차이를 보이지 않았다(p>0.05). 2. 상아질 변연에서 초고광도 중합군은 보통광도 중합군과 저광도 중합군에 비해 유의하게 높은 색소 침투도를 보였다(p<0.05). 3. 법랑질 변연에서의 4개 군의 색소 침투도는 서로 유의한 차이를 보이지 않았다(p>0.05). 4. 모든 군에서 상아질 변연에서의 색소 침투도는 법랑질군에서의 색소 침투도에 비해 유의하게 높았다(p<0.05).

  • PDF

Evaluation of penetration depth of 2% chlorhexidine digluconate into root dentinal tubules using confocal laser scanning microscope

  • Vadhana, Sekar;Latha, Jothi;Velmurugan, Natanasabapathy
    • Restorative Dentistry and Endodontics
    • /
    • 제40권2호
    • /
    • pp.149-154
    • /
    • 2015
  • Objectives: This study evaluated the penetration depth of 2% chlorhexidine digluconate (CHX) into root dentinal tubules and the influence of passive ultrasonic irrigation (PUI) using a confocal laser scanning microscope (CLSM). Materials and Methods: Twenty freshly extracted anterior teeth were decoronated and instrumented using Mtwo rotary files up to size 40, 4% taper. The samples were randomly divided into two groups (n = 10), that is, conventional syringe irrigation (CSI) and PUI. CHX was mixed with Rhodamine B dye and was used as the final irrigant. The teeth were sectioned at coronal, middle and apical levels and viewed under CLSM to record the penetration depth of CHX. The data were statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests. Results: The mean penetration depths of 2% CHX in coronal, middle and apical thirds were $138{\mu}m$, $80{\mu}m$ and $44{\mu}m$ in CSI group, respectively, whereas the mean penetration depths were $209{\mu}m$, $138{\mu}m$ and $72{\mu}m$ respectively in PUI group. Statistically significant difference was present between CSI group and PUI group at all three levels (p < 0.01 for coronal third and p < 0.001 for middle and apical thirds). On intragroup analysis, both groups showed statistically significant difference among three levels (p < 0.001). Conclusions: Penetration depth of 2% CHX into root dentinal tubules is deeper in coronal third when compared to middle and apical third. PUI aided in deeper penetration of 2% CHX into dentinal tubules when compared to conventional syringe irrigation at all three levels.

THE EFFECTS OF SEALING ON THE PLASMA-SPRAYED OXIDE-BASED COATINGS

  • Kim, Hyung-Jun;Sidoine Odoul;Kweon, Young-Gak
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.53-58
    • /
    • 2002
  • Electrical insulation and mechanical properties of the plasma sprayed oxide ceramic coatings were studied before and after the sealing treatment of the ceramic coatings. Plasma sprayed A1$_2$O$_3$-TiO$_2$ coating as the reference coating was sealed using three commercial sealants based on polymer. Penetration depth of the sealants to the ceramic coating was evaluated directly from the optical microscope using a fluorescent dye. It is estimated that the penetration depth of the sealants to the ceramic coating is from 0.2 to 0.5 mm depending on the sealants used. The preliminary test results with a DC puncture tester imply that the dielectric breakdown voltage mechanism of plasma sprayed ceramic coatings has been determined to be a corona mechanism. Dielectric breakdown voltage of the as-sprayed and as-ground samples have shown a linear trend with regard to the thickness showing an average dielectric strength of 20 kV/mm for the thickness scale studied. It is also shown that grinding the coating before sealing and adding fluorescent dye do not agent the penetration depth of sealants. All of the microhardness, two-body abrasive wear resistance, bond strength, and surface roughness of the ceramic coating after the sealing treatment are improved. The extent of improvement is different from the sealants used. However, three-point bending stress of the ceramic coating after the sealing treatment is decreased. This is attributed to the reduced micro-crack toughening effect since the cracks propagate easily through the lamellar of the coating without crack deflection and/or branching after the sealing treatment.

  • PDF

근관 밀폐도에 미치는 도말층 및 상아질 접착강화제의 영향 (EFFECTS OF SMEAR LAYER AND DENTIN PRIMERS ON THE SEALING ABILITY OF ROOT CANAL)

  • 양진석;황인남;김원재;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제25권4호
    • /
    • pp.527-535
    • /
    • 2000
  • The purpose of this study was to evaluate effects of smear layer and dentin primers on the sealing ability of root canals. 126 extracted human teeth with single, straight canals and mature apices were used. The Samples were first classified into six groups as follows: presence of smear layer; absence of smear layer; Scotchbond Bond Multi-Purpose; All Bond 2; Mac Bond 2; Clearfil Liner Bond 2. A Positive control was also established. All teeth except the control group were then obturated with thermoplasticized gutta-percha and AH26. Electrochemical and dye penetration technique were later used to evaluate the degree of micro leakage through the root canal. Seventy teeth were then immersed in a 1% potassium chloride solution and An external power supply(DC 10 V) was then applied to the circuit for the electrochemical microleakage test. The degree of Microleakage was determined over period of 28 days before being evaluated. In total, 48 teeth were submitted to the dye infiltration technique. All specimen were suspended in 2% methylene blue dye for 1 week before being longitudinally split. The degree of dye infiltration was measured under a stereo microscope at ${\times}10$ magnification and evaluated. The results were as follows: 1. Apical microleakage increased throughout the test period in all group and one group having a smear layer showed a dramatic increase under electrochemical test (p<0.05). In the group having smear layer, the degree of apical microleakage was the highest, and the micro leakage was much higher than in the smear layer removed group in electrochemical test (p<0.05). Scotchbond Multi-Purpose, All Bond 2, Mac Bond 2 and Clearfil Liner Bond 2 showed lower micro leakage than one group having smear layer. The All Bond 2 and Clearfil Liner Bond 2 treated groups showed the lowest microleakage in electrochemical test (p<0.05). 2. There was no significant difference between the experimental groups in dye penetration technique. These results suggested that the removal of the smear layer from root canal and concomitantly the application of dentin primer into root canal could improve the sealing ability of root canal obturation.