Leakage studies have been performed frequently, since a fluid-tight seal provided by various dental fill-ing materials has been considered clinically important. The leakage of the various root-end filling materials has been widely investigated mostly dye penetration method. These dye studies cannot offer any information about the quality of the seal of a test material over a long period of time The purpose of this study was to evaluate the microleakage of root end cavities in blood contamination filed amalgam, intermediate restorative material(IRM), light cured glass ionomer cement(GI) and mineral trioxide aggregate(MTA) by means of a modified fluid transport model. Fifty standard human root sections, each 5mm high and with a central pulp lumen of 3mm in diameter, were and filled with our commonly used or potential root end fill ing materials after they were contaminated with blood. At 24h. 72h, 1, 2, 4, 8, and 12 weeks after filling, leakage along these filling materials was determined under a low pressure of 10KPa(0.1atm) using a fluid transport model. The results were as follows : 1 MTA group showed a tendency of decreasing percent of gross leakage (20m1/day) in process of time, whereas the other materials showed a tendency of increasing in the process time. 2. At the all time interval, GI group leaked significantly less than amalgam group and IRM group (p<0.05). 3. At the 4 weeks, the percentage of gross leakage in MTA group decreased to 0% thereafter, the low per-centage of gross leakage was maintained in MTA group until the end of the experiment, whereas the percentage in IRM group increased to 100% 4. At the 12 weeks, percentage of gross leakage was significantly low in MTA group(0%), comparison with GI group(40%), amalgam group(90%) and IRM group(100%), but there was no significant difference between latter two materials.
This study evaluated the microleakage performance of four self-etcing primer adhesives(Clearfil SE Bond, Clearfil Liner Bond 2, UniFil Bond, and FL Bond) and one self-etching adhesive(Prompt L-Pop). Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of 50 extracted human molar teeth. Prepared teeth were randomly divided into five groups and restored using one of five adhesives and composite resins: Prompt L-Pop/Filtek Z 250(Group 1), Clearfil SE Bond/Clearfil AP-X(Group 2), Clearfil Liner Bond 2/Clearfil AP-X(Group 3), UniFil Bond/UniFil F(Group 4), and FL Bond/Filtek Z 250(Group 5). Following one day storage in room temperature water, the restored teeth were thermocycled for 500 cycles between 5$^{\circ}C$ and 55$^{\circ}C$. Marginal microleakage was assessed by dye penetration using 2% methylene blue dye. After 24 hours, the teeth were sectioned longitudinally and evaluated for microleakage under steromicroscope The data were statistically analysed by Kruskal-Wallis Test, Mann-Whitney and Wilcoxon signed ranked tests. The results of this study were as follows ; 1. The microleakges at both enamel and dentinal mal$.$gins were the lowest in group 4. increasing among groups in the following order: group 2, follwed by group 5, follwed by group 1, and the highest in group 3. 2. At the enamel margins, the microleakage of group 3 was significantly higher than those of groups 2. 4 and 5(p<0.05), and also the microleakage of group 1 was statistically higher than those of groups 2 and 5(p<0.05). 3. At the dentinal margins, microleakage of group 3 was signincantly higher than microleakages of groups 1, 2, 4 and 5(p<0.05). 4. Compared with microleakages between the enamel and dentinal margins of each group, groups 1, 4 and 5 at enamel margin and group 2 and group 3 at dentinal margin were higher microleakage. But there was no significant difference between enamel and dentinal microleakages of each group(p>0.05).
The resin modified glass ionomer cements(RMGICs) have been used for years since 1989. Recently it has been developed for luting of fixed restorations. To evaluate the bond strength and marginal leakage of RMGICs for luting usage, the 80 extracted human molars which had uniform area of exposed dentin were cemented with 3 types of RMGICs(Fuji Duet, Advance, Vitremer), a conventional Glass Ionomer Cement(GIC-Fuji I), and a resin cement (Panavia 21) to base metal alloy(Ni-Cr-Be). After thermocycling the specimens were immersed in basic fuschin dye for measuring marginal leakage. The shear bond strength was measured with Instron and the maximum dye penetration was measured to 0.1mm. The types of fractured patterns were determined with stereoscope(${\times}7.5$). The results are as follows. 1. The difference between 3 RMGICs and a conventional GIC in shear bond strength was not statistically significant. It seemed that RMGICs had lower shear bond strength than resin cement. (p<0.01) 2. The mean scores of marginal leakage had no significant difference between the resin cement and 3 RMGICs but it was much higher in conventional GIC than the RMGICs (p<0.05) 3. It was determined that the manufacturer and the methods of dentin pretreatment determined the pattern of fracture surfaces and the frequency of adhesive failure between teeth and 3 RMGICs standed as in following order - Vitremer, Advance, Fuji Duet. (p<0. 01) When the fracture pattern was analyzed, it could be said that the materials and the method of dentin pretreatment have much effect on bonding states. This means that the dentin bonding agents should be improved. But the limited products in this experiment can not evaluate the physical properties of the entire RMGICs. Therefore a further study which can evaluate various RMGICs should be in progress to develope better cements.
대한치과보존학회 2008년도 Spring Scientific Meeting(the 129th) of Korean Academy if Conservative Dentistry
/
pp.204-212
/
2008
본 연구의 목적은 Resilon을 이용한 근관충전시 methacrylate-based root canal sealer와 자기-접착 레진시멘트의 사용에 따른 치근단 미세누출을 비교해 보는 것이다. 70개 단근치를 ProFile NiTi rotary instrument와 GG drill을 이용해 근관성형 하였다. 치근을 4개의 실험군 (n = 15)과 2개의 대조군 (n = 5)으로 분류하여 측방가압법으로 충전하였다 <1군: GP + AH-26, 2군: Resilon + RealSeal primer&sealant, 3군: Resilon + Rely-X Unicem, 4군: Resilon + Biscem> 7일간 1% 메틸렌블루 용액에 침적 후 수직절단하여 치근첨부터 색소의 침투도를 측정하였다. 1 군에서 가장 적은 미세누출값이 측정되었고, 2, 3, 4군간의 통계적 유의성은 없었다. 이번 연구의 결과에 따르면, 자가-접착 레진시멘트는 Resilon을 이용한 근관충전시 sealer로 사용이 가능하리라 생각된다.
이 연구의 목적은 연화 gutta-percha 주입 근관충전법에서 효과적인 근관폐쇄를 얻기위해 함께 사용하는 sealer의 척절한 조도률 측정하는데 있다. 실험에 사용된 sealer는 $0.5m{\ell}$의 유지놀에 산화아연 분말을 혼화하여 얻은 $0.5m{\ell}$의 혼합물이 두 유리판 사이에서 120gm의 무게에 의하여 퍼지는 정도로써 측정한 조도에 상응하는 분말액비(比) 대로 산화아연 분말과 유지놀을 혼합하여 조도 65.45mm, 46.80mm, 28.95mm 및 22.60mm의 sealer를 제조하였다. 발거된 125개의 하악 대구치에서 원심근을 절취하여 step-back 방법으로 근관형성, 제조된 sealer를 근관벽에 피복하고 $70^{\circ}C$에서 연화된 gutta-percha를 주입, 근관충전하였다. 실험치근은 2% methylene-blue 색소용액에 침적시켜 $37^{\circ}C$의 항온기에서 48시간 경과시킨후 근단공을 통한 색소침투의 정도를 측정하여 다읍의 결과를 얻었다. 연화 gutta-percha 주입 근관충전법에서 sealer를 사용하지 않은 군이 sealer를 사용한 군보다 색소침투는 더 크게 나타났다(p<0.05). 일정한 조도의 범위 65.45mm~22.60mm에서 조도 65.45mm의 sealer는 조도 28.9mm 및 22.60mm보다 폐쇄효과는 더 높게 나타났고(p<0.05) 조도 46.80mm의 sealer 보다도 더 높게 나타났으나 통계학적 유의성은 없었다.
본 연구의 목적은 건전 법랑질과 우식 병소의 형광 차이를 증진시켜 QLF의 영상학적인 진단강도를 높이고, QLF로 촬영한 이미지 상에서 착색과 우식병소를 감별하기 위해 형광 염색제인 플루오레세인나트륨을 접목하여 사람 치아의 법랑질 표면에 유발된 초기 우식병소를 평가하는데 있다. 치아우식증이나 균열이 없는 최근 발거된 소구치 및 제3대구치를 대상으로 하여 치아의 평활면을 $6mm{\times}3mm{\times}3mm$ 크기로 절단한 후 아크릴 주형에 매몰하였고, 시편 표면적의 1/2에 nail varnish를 도포하여 대조군으로 설정하였다. 시편은 무작위로 15개씩 총 6개 탈회그룹(6, 12, 24, 48, 72, 96시간)으로 나누었다. 시편을 각 시간에 맞게 탈회시키고 생리 식염수로 세척한 후 QLF-D를 이용하여 탈회 정도(${\Delta}F$)를 측정하고 0.075% 플루오레세인나트륨을 적용한 후 세척하고 ${\Delta}F$ 값을 측정하여 그 값을 비교하였다. 시편의 중앙 부위를 삭제하고 연마하여 주사전자현미경 상으로 영상을 저장한 후 병소 깊이를 측정하였다. QLF를 이용하여 관찰한 우식병소는 건전 법랑질보다 어둡게, 플루오레세인나트륨을 도포한 후 QLF로 관찰한 우식병소는 건전 법랑질보다 밝게 관찰되었으며 탈회시간이 증가함에 따라 형광염료는 더 많이 침투하였다. 플루오레세인나트륨을 적용한 후 측정한 ${\Delta}F$ 값은 염색 전과 비교하여 모두 증가하였다(p < 0.05). QLF 수치와 병소 깊이는 높은 상관관계를 보였고 회귀분석을 통해 선형 방정식을 추출하였다. 따라서 플루오레세인나트륨을 접목시킨 QLF 측정은 임상적으로 초기우식을 감지하고 분류하는데 기여할 수 있을 것이며, QLF로 촬영한 이미지에서 우식병소와 착색을 감별하는데 도움을 줄 것이다.
The use of flowable composite resins as liners in class II packable composite restoration has been suggested by some manufacturers. However, the contributions of this technique are unproven. The purpose of this study was to compare the gingival microleakage in class II packable composite restorations with or without the use of flowable composite resins as liners. Slot cavities were prepared on both proximals of 80 extracted human molars and randomly assigned to 8 groups of 20 each. The gingival margins were located at 1mm above CEJ in 80 cavities (group1-4) and 1mm below CEJ in 80 cavities (group5-8). The prepared teeth were mounted in the customized tray with adjacent teeth to simulate clinical conditions and metallic matrix band (Sectional matrix) and wooden wedges were applied. After acid etching and application of Single Bond, each group was restored with the following materials using incremental placement technique: Group 1,5 (Filtek P60), group 2, 3, 4 and group 6, 7, 8 (AeliteFlo, TetricFlow, Revolution/ Filtek P60). All specimens were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 1 mimute dwell time, immersed 2% methylene blue dye for 24 hours and then rinsed with tab water. The specimens were embedded in clear resin and sectioned longitudinally through the center of restoration with a low speed diamond saw. Dye penetration at gingival margin was viewed at 20 magnification and analyzed on a scale of 0 to 4. Kruscal-Wallis One way analysis and Mann-Whitney Rank sum test were used to analyze the results. The results of this study were as follows. 1. The leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. On the enamel margin, packable composite resins with flowable liners showed lower leakage than those without flowable liners, but there were no significant differences among the four groups(P>0.05). 3. On the dentin margin, four groups demonstrated moderate to severe leakage, and there were no significant differences in leakage values(P>0.05).
본 연구의 목적은 Resilon을 이용한 근관충전시 methacrylate-based root canal sealer와 자가-접착 레진시멘트의 사용에 따른 치근단 미세누출을 비교해 보는 것이다. 70개 단근치를 ProFile NiTi rotary instrument와 GG drill을 이용해 근관성형 하였다. 치근을 4개의 실험군 (n = 15)과 2개의 대조군 (n = 5)으로 분류하여 측방가압법으로 충전하였다. <1군: GP + AH-26, 2군: Resilon + RealSeal primer&sealant, 3군: Resilon + Rely-X Unicem, 4군: Resilon + Biscem > 7일간 1% 메틸렌블루 용액에 침적 후 수직절단하여 치근첨부터 색소의 침투도를 측정하였다. 1군에서 가장 적은 미세누출값이 측정되었고, 2, 3, 4군 간의 통계적 유의성은 없었다. 이번 연구의 결과에 따르면, 자가-접착 레진시멘트는 Resilon을 이용한 근관충전시 sealer로 사용이 가능하리라 생각된다.
Adhesion of composite resin to tooth structure has been of tremendous signgicance in clinical dentistry. Due to the lack of adhesion between composite restorative resins and enamel and dentin, microleakage occurs at the tooth/restoration interface. This may lead to discoloration, secondary caries, marginal breakdown, postoperative sensitivity, and even pulpal pathology. According to extensive use of composite resin, every effort on improving bonding strength and reducing microleakage between a tooth and composite resin has been continued. This study was conducted to determine the difference in microleakage in enamel and dentin treated with air-abrasion, acid etching and combination when restored with composite resin. Class V cavities were prepared on 30 premolars. The specimens were divided into following groups. group 1:air-abrasion+Scotchbond Multi-purpose group 4 :air-abrasion+All-Bond 2 group 2:acid etching+Scotchbond Multi-purpose group 5 :acid etching+All-Bond 2 group 3:combination+Scotchbond Multi-purpose group 6 :combination+All-Bond 2 #combination:air-abrasion + acid etching The specimens were filled with Z-100 after application of Scotchbond Multi-purpose and All-Bond 2. Thermocycling was conducted by alternately dipping the specimens in $5^{\circ}C$ and $55^{\circ}C$ water for 30 seconds 500 times. 1% methylene blue was applied and the specimens were left for 24 hours at $37^{\circ}C$. After washing out the dye, the tooth was sectioned buccolingually along the axis. The sectioned surface was observed with stereoscope for dye penetration. The author has measured the microleakage in teeth prepared with air-abrasion, acid ethching and combination to study the difference in microleakage following different methods of tooth surface treatment and has come to following results. 1. In comparing microleakage between groups, group 1 and 4 showed statistically significant difference from group 2, 3, 5 and 6(p<0.05). There was no significant difference among group 2, 3, 5, 6(p>0.05) nor between group 1 and 4(p>0.05). 2. In comparing microleakage among tooth surface treatment methods, Air-abrasion group showed significantly more microleakage than acid etching group and combination(airabrasion + acid etching) group(p<0.05). Combination(acid etching+air-abrasion)group tended to show lesser microleakage than acid etching group, but this was not statistically significant(p>0.05). 3. In comparing microleakage between bonding agents, there was no statistically significant difference between Scotch bond Multi-purpose and All-Bond 2(p>0.05).
The purpose of this in vitro study was to evaluate the microleakage of 5 curing methods in class V composite restorations which are composed of two-step light curing, pulse-delay cure, low curing-light intensity, moderate curing-light intensity and high curing-light intensity. In this study, class V cavities were prepared on buccal and lingual surfaces of 50 extracted human upper or lower molars on cementum margin. Single Bond adhesive and Z-100 shade A2 were applied for each group following the manufacture's instruction. The experimental teeth were randomly divided into 5 groups of 10 samples (20 surfaces) each. Group 1: two-step light curing; Group 2: pulse-delay cure; Group 3: low curing-light intensity; Group 4: moderate curing-light intensity; Group 5: high curing-light intensity. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 60 teeth were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimen was then observed with a stereomicroscope at ${\times}20$. The composite resin/tooth interfaces were examined under Scanning Electron Microscopy. The results were statistically analyzed using the Kruskal-Wallis One Way ANOVA and Dunn's Method. The results of this study were as follows. 1. In all groups, the leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. No group in this study showed significant differences in leakage values at both the enamel and the dentin margins(P<0.05). 3. In all groups, the gaps seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 4. The gaps in this study showed significant differences and two-step light-curing and low curing-light intensity produced significant less gap than high curing-light intensity(P<0.05).
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.